Hannes Dillinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hannes Dillinger has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Sebastian Kozerke
Institute for Biomedical Engineering
5 shared publications - Christian Guenthner
Institute for Biomedical Engineering University and ETH Zurich Zurich Switzerland
2 shared publications - Jonas Walheim
Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
2 shared publications - Sebastian Schmitter
Medical Physics in Radiology, German Cancer Research Center (DKFZ) Heidelberg Germany
2 shared publications - Alexander Gotschy
University and ETH Zurich
1 shared publication - Aref Saberi
Soft Tissue Engineering and Mechanobiology, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
1 shared publication
Latest Publications
- Open Access
Functional Performance of Electrospun Tissue-Engineered Heart Valve Scaffolds Across Geometries Under Aortic Conditions
Electrospun, bioresorbable polymer scaffolds are a promising platform for tissue-engineered heart valves (TEHVs) owing to their fibrous microstructure, tunable mechanics and capacity to support host-cell infiltration and remodeling. Recent in-vitro parametric studies of bioprosthetic heart valve (BHV) geometry have used silicone cast valves to link design parameters to hemodynamic performance and leaflet strain, but the functional behavior of electrospun whole-valve TEHV scaffolds across distinct leaflet geometries and clinically relevant aortic conditions remains poorly characterized. Here, we present an end-to-end workflow in which polycaprolactone (PCL) is electrospun directly onto parametrized, 3D-printed mandrels derived from two established analytical leaflet geometry models, yielding 21 whole-valve scaffolds across four geometries without cutting and assembling flat fiber sheets or suturing of flat fiber sheets. Fiber diameter, orientation and pore area were assessed by scanning electron microscopy and found to be consistent across scaffolds and geometries. Two scaffolds of each of four geometries were tested in a pulse duplicator under hypotensive, normotensive and hypertensive aortic conditions. All scaffolds opened and closed physiologically under all conditions, with a mean maximum geometric orifice area (GOA) of 44.5% of the valve area and a mean peak transvalvular pressure gradient of 10mmHg. Leaflet geometry had no apparent systematic effect on flow and pressure waveforms or on GOA. The mean regurgitant fraction was 82%, most likely due to leakage through the porous fiber network rather than incomplete leaflet closure. Electrospun whole-valve scaffolds thus achieve favorable leaflet kinematics at clinically relevant aortic conditions and the presented workflow provides a reproducible, parametric framework for their fabrication and translation toward regenerative heart valve replacement.
Open AccessFunctional Performance of Electrospun Tissue-Engineered Heart Valve Scaffolds Across Geometries Under Aortic Conditions
Electrospun, bioresorbable polymer scaffolds are a promising platform for tissue-engineered heart valves (TEHVs) owing to their fibrous microstructure, tunable mechanics and capacity to support host-cell infiltration and remodeling. Recent in-vitro parametric studies of bioprosthetic heart valve (BHV) geometry have used silicone cast valves to link design parameters to hemodynamic performance and leaflet strain, but the functional behavior of electrospun whole-valve TEHV scaffolds across distinct leaflet geometries and clinically relevant aortic conditions remains poorly characterized. Here, we present an end-to-end workflow in which polycaprolactone (PCL) is electrospun directly onto parametrized, 3D-printed mandrels derived from two established analytical leaflet geometry models, yielding 21 whole-valve scaffolds across four geometries without cutting and assembling flat fiber sheets or suturing of flat fiber sheets. Fiber diameter, orientation and pore area were assessed by scanning electron microscopy and found to be consistent across scaffolds and geometries. Two scaffolds of each of four geometries were tested in a pulse duplicator under hypotensive, normotensive and hypertensive aortic conditions. All scaffolds opened and closed physiologically under all conditions, with a mean maximum geometric orifice area (GOA) of 44.5% of the valve area and a mean peak transvalvular pressure gradient of 10mmHg. Leaflet geometry had no apparent systematic effect on flow and pressure waveforms or on GOA. The mean regurgitant fraction was 82%, most likely due to leakage through the porous fiber network rather than incomplete leaflet closure. Electrospun whole-valve scaffolds thus achieve favorable leaflet kinematics at clinically relevant aortic conditions and the presented workflow provides a reproducible, parametric framework for their fabrication and translation toward regenerative heart valve replacement.
- Open Access
- 5 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
A Physiologic Left Ventricle Flow Phantom for 4D Flow MRI Applications and CFD Verification
Purpose: In vivo verification for the development of cardiac MRI and CFD simulations is limited by scan time and motion artifacts. We developed a subject-specific, MRI-compatible left ventricle (LV) phantom within a closed-loop circulation system driven by an MRI-safe pump to reproduce cardiac motion and provide robust data for high-fidelity model validation. Methods: The LV was fabricated from a PVA-based hydrogel to ensure MRI contrast, mechanical stability, and reusability. The complete setup fulfills key requirements for long-term leakage-free operation, close coil placement, and resembles in vivo soft-tissue contrasts. The setup reproduces healthy end-diastolic and end-systolic geometries, including physiologic contraction and papillary muscles. Integrated aortic and mitral valves approximate physiological opening and closing. High image contrast enabled time-resolved segmentation of the LV geometry. Results: The LV shape matched the target anatomy well, despite minor deviations at the basal transition and in valve orifice, with mild aortic stenosis and mitral regurgitation. 4D flow MRI confirmed physiological flow patterns, including diastolic vortex ring formation and realistic systolic outflow. Velocity estimates confirmed the phantom’s applicability in an in vitro setting without scan time limitations. The acquired time-resolved MRI data enabled CFD simulations incorporating LV and valve motion, although segmentation accuracy remains a primary source of uncertainty. Conclusion: This LV phantom provides a stable, MRI-compatible platform for generating reproducible data to validate modeling of intracardiac hemodynamics. Its realistic anatomy, motion, and flow patterns support both simulation validation and MRI sequence development. Future work will focus on improving valve kinematics and LV motion fidelity.
- 5 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
Open AccessA Physiologic Left Ventricle Flow Phantom for 4D Flow MRI Applications and CFD Verification
Purpose: In vivo verification for the development of cardiac MRI and CFD simulations is limited by scan time and motion artifacts. We developed a subject-specific, MRI-compatible left ventricle (LV) phantom within a closed-loop circulation system driven by an MRI-safe pump to reproduce cardiac motion and provide robust data for high-fidelity model validation. Methods: The LV was fabricated from a PVA-based hydrogel to ensure MRI contrast, mechanical stability, and reusability. The complete setup fulfills key requirements for long-term leakage-free operation, close coil placement, and resembles in vivo soft-tissue contrasts. The setup reproduces healthy end-diastolic and end-systolic geometries, including physiologic contraction and papillary muscles. Integrated aortic and mitral valves approximate physiological opening and closing. High image contrast enabled time-resolved segmentation of the LV geometry. Results: The LV shape matched the target anatomy well, despite minor deviations at the basal transition and in valve orifice, with mild aortic stenosis and mitral regurgitation. 4D flow MRI confirmed physiological flow patterns, including diastolic vortex ring formation and realistic systolic outflow. Velocity estimates confirmed the phantom’s applicability in an in vitro setting without scan time limitations. The acquired time-resolved MRI data enabled CFD simulations incorporating LV and valve motion, although segmentation accuracy remains a primary source of uncertainty. Conclusion: This LV phantom provides a stable, MRI-compatible platform for generating reproducible data to validate modeling of intracardiac hemodynamics. Its realistic anatomy, motion, and flow patterns support both simulation validation and MRI sequence development. Future work will focus on improving valve kinematics and LV motion fidelity.
- Open Access
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2370-2378
Analytical Ground Truth for Phase-Contrast MRI Experiments and Simulations: Open-Source Precision-Controlled Bidirectional Rotational Phantom
We present a fully open-source, air-driven bidirectional, rotational MRI phantom. It enables an accurate and reproducible evaluation of displacement artefacts for any MRI sequence and velocity field and acceleration sensitivity for phase-contrast MRI (PC-MRI) sequences. Its unique feature of analytically defined motion is expected to narrow the gap between simulations and experiments for in-silico and in-vitro experiments using the very same sequence code. A rotational phantom was bidirectionally driven (clockwise (CW) / counterclockwise (CCW)) by an actively controlled airflow. The rotating cylinder filled with a Polyvinylpyrrolidone-water mixture was monitored via an external laser-based tachometer system. Vendor-supplied and custom open-source PC-MRI sequences were evaluated on a 3T MRI system and used as input for Bloch simulations. Resulting magnitude and velocity images were evaluated against the phantom's ground truth data. For physiological angular velocities, displacement errors resulted in a 10% radial stretch while apparent acceleration sensitivity is 5% of venc. The time difference between velocity and spatial encoding time points of 1.9ms determining the severity of the artefacts could be quantified without prior knowledge of details about the MR sequence. Simulation and experiment yielded excellent agreement. The phantom enables an easy, precise and repeatable evaluation of motion sensitivity of MR sequences and may offer a future reference measurement. Additional timing parameters of MR sequences may be reported in future literature to improve comparability. The seamless MRI sequence definition for in-silico and in-vitro experiments narrows a significant gap in MR research. This work establishes a reproducible, standardized validation framework for PC-MRI techniques that can be readily implemented across institutions, facilitating quality assurance procedures and supporting the development of more accurate flow quantification methods in clinical applications.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2370-2378
Open AccessAnalytical Ground Truth for Phase-Contrast MRI Experiments and Simulations: Open-Source Precision-Controlled Bidirectional Rotational Phantom
We present a fully open-source, air-driven bidirectional, rotational MRI phantom. It enables an accurate and reproducible evaluation of displacement artefacts for any MRI sequence and velocity field and acceleration sensitivity for phase-contrast MRI (PC-MRI) sequences. Its unique feature of analytically defined motion is expected to narrow the gap between simulations and experiments for in-silico and in-vitro experiments using the very same sequence code. A rotational phantom was bidirectionally driven (clockwise (CW) / counterclockwise (CCW)) by an actively controlled airflow. The rotating cylinder filled with a Polyvinylpyrrolidone-water mixture was monitored via an external laser-based tachometer system. Vendor-supplied and custom open-source PC-MRI sequences were evaluated on a 3T MRI system and used as input for Bloch simulations. Resulting magnitude and velocity images were evaluated against the phantom's ground truth data. For physiological angular velocities, displacement errors resulted in a 10% radial stretch while apparent acceleration sensitivity is 5% of venc. The time difference between velocity and spatial encoding time points of 1.9ms determining the severity of the artefacts could be quantified without prior knowledge of details about the MR sequence. Simulation and experiment yielded excellent agreement. The phantom enables an easy, precise and repeatable evaluation of motion sensitivity of MR sequences and may offer a future reference measurement. Additional timing parameters of MR sequences may be reported in future literature to improve comparability. The seamless MRI sequence definition for in-silico and in-vitro experiments narrows a significant gap in MR research. This work establishes a reproducible, standardized validation framework for PC-MRI techniques that can be readily implemented across institutions, facilitating quality assurance procedures and supporting the development of more accurate flow quantification methods in clinical applications.
- Open Access
- 25 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1824-1825
A do‐it‐yourself approach to waste‐heat recovery in MRI
- 25 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1824-1825
Open AccessA do‐it‐yourself approach to waste‐heat recovery in MRI
- Open Access
- 3 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (4) , 1498-1511
Beat phenomena of oscillating readouts
Purpose: To demonstrate slowly varying, erroneous magnetic field gradients for oscillating readouts due to the mechanically resonant behavior of gradient systems.Methods: Projections of a static phantom were acquired using a one‐dimensional (1D) EPI sequence with varying EPI frequencies ranging from 1121 to 1580 Hz on clinical 3T systems (30 mT/m, 200 T/m/s). Phase due to static B0 inhomogeneities was eliminated by a complex division of two separate scans with different polarities of the EPI readout. The temporal evolution of phase was evaluated and related to the mechanical resonances of the gradient systems derived from the gradient modulation transfer function. Additionally, the impact of temporally varying mechanical resonance effects on EPI was evaluated using an echo‐planar spectroscopic imaging sequence.Results: A beat phenomenon resulting in a slowly varying phase was observed. Its temporal frequency was given by the difference between the EPI frequency and the mechanical resonance frequency of the activated gradient axis. The maximum erroneous, oscillating phase during phase encoding was ±0.5 rad for an EPI frequency of 1281 Hz. Echo‐planar spectroscopic imaging images showed the resulting time‐dependent stretching/compression of the FOV.Conclusion: Oscillating readouts such as those used in EPI can result in low‐frequency, erroneous phase contributions, which are explained by the beat phenomenon. Therefore, EPI phase‐correction approaches may need to include beat effects for accurate image reconstruction.
- 3 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (4) , 1498-1511
Open AccessBeat phenomena of oscillating readouts
Purpose: To demonstrate slowly varying, erroneous magnetic field gradients for oscillating readouts due to the mechanically resonant behavior of gradient systems.Methods: Projections of a static phantom were acquired using a one‐dimensional (1D) EPI sequence with varying EPI frequencies ranging from 1121 to 1580 Hz on clinical 3T systems (30 mT/m, 200 T/m/s). Phase due to static B0 inhomogeneities was eliminated by a complex division of two separate scans with different polarities of the EPI readout. The temporal evolution of phase was evaluated and related to the mechanical resonances of the gradient systems derived from the gradient modulation transfer function. Additionally, the impact of temporally varying mechanical resonance effects on EPI was evaluated using an echo‐planar spectroscopic imaging sequence.Results: A beat phenomenon resulting in a slowly varying phase was observed. Its temporal frequency was given by the difference between the EPI frequency and the mechanical resonance frequency of the activated gradient axis. The maximum erroneous, oscillating phase during phase encoding was ±0.5 rad for an EPI frequency of 1281 Hz. Echo‐planar spectroscopic imaging images showed the resulting time‐dependent stretching/compression of the FOV.Conclusion: Oscillating readouts such as those used in EPI can result in low‐frequency, erroneous phase contributions, which are explained by the beat phenomenon. Therefore, EPI phase‐correction approaches may need to include beat effects for accurate image reconstruction.
- Open Access
- 1 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1937-1947
Direct comparison of gradient Fidelity and acoustic noise of the same MRI system at 3 T and 0.75 T
Purpose: To analyze the difference between gradient fidelity and acoustic noise of the same MRI scanner operated at product field strength (3 T) and lower field strength (0.75 T).Methods: Gradient modulation transfer functions (GMTFs) were measured using a four‐slice 2D phase‐encoded chirp‐based sequence on the same scanner operated at 3 T and, following ramp‐down, at 0.75 T with identical gradient specifications (40 mT/m, 200 T/m/s). Calibrated audio measurements were performed at both field strengths to correlate audio spectra with GMTFs.Results: While eddy currents were independent of field strength, mechanical resonances were substantially decreased at lower field, resulting in a reduction of GMTF distortions by up to 95% (88% on average) at the mechanical resonances of the gradient system. Audio spectra amplitudes were reduced by up to 87% when comparing 0.75 T versus 3 T.Conclusion: Lower static fields lead to reduced Lorentz forces on the gradient coil and, in turn, to reduced mechanical resonances, thereby improving gradient fidelity. Simultaneously, the reduction of acoustic noise may help to improve patient comfort.
- 1 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1937-1947
Open AccessDirect comparison of gradient Fidelity and acoustic noise of the same MRI system at 3 T and 0.75 T
Purpose: To analyze the difference between gradient fidelity and acoustic noise of the same MRI scanner operated at product field strength (3 T) and lower field strength (0.75 T).Methods: Gradient modulation transfer functions (GMTFs) were measured using a four‐slice 2D phase‐encoded chirp‐based sequence on the same scanner operated at 3 T and, following ramp‐down, at 0.75 T with identical gradient specifications (40 mT/m, 200 T/m/s). Calibrated audio measurements were performed at both field strengths to correlate audio spectra with GMTFs.Results: While eddy currents were independent of field strength, mechanical resonances were substantially decreased at lower field, resulting in a reduction of GMTF distortions by up to 95% (88% on average) at the mechanical resonances of the gradient system. Audio spectra amplitudes were reduced by up to 87% when comparing 0.75 T versus 3 T.Conclusion: Lower static fields lead to reduced Lorentz forces on the gradient coil and, in turn, to reduced mechanical resonances, thereby improving gradient fidelity. Simultaneously, the reduction of acoustic noise may help to improve patient comfort.
- Open Access
- 16 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1231-1249
Fundamentals of turbulent flow spectrum imaging
Purpose: To introduce a mathematical framework and in‐silico validation of turbulent flow spectrum imaging (TFSI) of stenotic flow using phase‐contrast MRI, evaluate systematic errors in quantitative turbulence parameter estimation, and propose a novel method for probing the Lagrangian velocity spectra of turbulent flows.Theory and Methods: The spectral response of velocity‐encoding gradients is derived theoretically and linked to turbulence parameter estimation including the velocity autocorrelation function spectrum. Using a phase‐contrast MRI simulation framework, the encoding properties of bipolar gradient waveforms with identical first gradient moments but different duration are investigated on turbulent flow data of defined characteristics as derived from computational fluid dynamics. Based on theoretical insights, an approach using velocity‐compensated gradient waveforms is proposed to specifically probe desired ranges of the velocity autocorrelation function spectrum with increased accuracy.Results: Practical velocity‐encoding gradients exhibit limited encoding power of typical turbulent flow spectra, resulting in up to 50% systematic underestimation of intravoxel SD values. Depending on the turbulence level in fluids, the error due to a single encoding gradient spectral response can vary by 20%. When using tailored velocity‐compensated gradients, improved quantification of the Lagrangian velocity spectrum on a voxel‐by‐voxel basis is achieved and used for quantitative correction of intravoxel SD values estimated with velocity‐encoding gradients.Conclusion: To address systematic underestimation of turbulence parameters using bipolar velocity‐encoding gradients in phase‐contrast MRI of stenotic flows with short correlation times, tailored velocity‐compensated gradients are proposed to improve quantitative mapping of turbulent blood flow characteristics.
- 16 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1231-1249
Open AccessFundamentals of turbulent flow spectrum imaging
Purpose: To introduce a mathematical framework and in‐silico validation of turbulent flow spectrum imaging (TFSI) of stenotic flow using phase‐contrast MRI, evaluate systematic errors in quantitative turbulence parameter estimation, and propose a novel method for probing the Lagrangian velocity spectra of turbulent flows.Theory and Methods: The spectral response of velocity‐encoding gradients is derived theoretically and linked to turbulence parameter estimation including the velocity autocorrelation function spectrum. Using a phase‐contrast MRI simulation framework, the encoding properties of bipolar gradient waveforms with identical first gradient moments but different duration are investigated on turbulent flow data of defined characteristics as derived from computational fluid dynamics. Based on theoretical insights, an approach using velocity‐compensated gradient waveforms is proposed to specifically probe desired ranges of the velocity autocorrelation function spectrum with increased accuracy.Results: Practical velocity‐encoding gradients exhibit limited encoding power of typical turbulent flow spectra, resulting in up to 50% systematic underestimation of intravoxel SD values. Depending on the turbulence level in fluids, the error due to a single encoding gradient spectral response can vary by 20%. When using tailored velocity‐compensated gradients, improved quantification of the Lagrangian velocity spectrum on a voxel‐by‐voxel basis is achieved and used for quantitative correction of intravoxel SD values estimated with velocity‐encoding gradients.Conclusion: To address systematic underestimation of turbulence parameters using bipolar velocity‐encoding gradients in phase‐contrast MRI of stenotic flows with short correlation times, tailored velocity‐compensated gradients are proposed to improve quantitative mapping of turbulent blood flow characteristics.
- 25 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1806-1816
On the limitations of echo planar 4D flow MRI
Purpose: To compare EPI and GRE readout in high‐flow velocity regimes and evaluate their impact on measurement accuracy in silico and in vitro.Theory and Methods: Phase‐contrast sequences for EPI and GRE were simulated using CFD velocity data to assess displacement artifacts as well as effective spatial resolution. In silico findings were validated experimentally using a steady flow phantom.Results: For EPI factor 5 and simulated stenotic flow with peak velocity of 2.2 m, displacement artifacts resulted in misregistration of 7.3 mm at echo time and the effective resolution was locally reduced by factors 5 and 8 compared to GRE for flow along phase and frequency encoding directions, respectively. In vitro, a maximum velocity difference between EPI factor 5 and GRE of 0.97 m was found.Conclusions: Four‐dimensional flow MRI using EPI readout results not only in considerable velocity misregistration but also in spatially varying degradation of resolution. The proposed work indicates that EPI is inferior to standard GRE for 4D flow MRI.
- 25 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1806-1816
On the limitations of echo planar 4D flow MRI
Purpose: To compare EPI and GRE readout in high‐flow velocity regimes and evaluate their impact on measurement accuracy in silico and in vitro.Theory and Methods: Phase‐contrast sequences for EPI and GRE were simulated using CFD velocity data to assess displacement artifacts as well as effective spatial resolution. In silico findings were validated experimentally using a steady flow phantom.Results: For EPI factor 5 and simulated stenotic flow with peak velocity of 2.2 m, displacement artifacts resulted in misregistration of 7.3 mm at echo time and the effective resolution was locally reduced by factors 5 and 8 compared to GRE for flow along phase and frequency encoding directions, respectively. In vitro, a maximum velocity difference between EPI factor 5 and GRE of 0.97 m was found.Conclusions: Four‐dimensional flow MRI using EPI readout results not only in considerable velocity misregistration but also in spatially varying degradation of resolution. The proposed work indicates that EPI is inferior to standard GRE for 4D flow MRI.
- Open Access
- 11 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
5D Flow Tensor MRI to Efficiently Map Reynolds Stresses of Aortic Blood Flow In-Vivo
Diseased heart valves perturb normal blood flow with a range of hemodynamic and pathologic consequences. In order to better stratify patients with heart valve disease, a comprehensive characterization of blood flow including turbulent contributions is desired. In this work we present a framework to efficiently quantify velocities and Reynolds stresses in the aorta in-vivo. Using a highly undersampled 5D Flow MRI acquisition scheme with locally low-rank image reconstruction, multipoint flow tensor encoding in short and predictable scan times becomes feasible (here, 10 minutes), enabling incorporation of the protocol into clinical workflows. Based on computer simulations, a 19-point 5D Flow Tensor MRI encoding approach is proposed. It is demonstrated that, for in-vivo resolution and signal-to-noise ratios, sufficient accuracy and precision of velocity and turbulent shear stress quantification is achievable. In-vivo proof of concept is demonstrated on patients with a bio-prosthetic heart valve and healthy controls. Results demonstrate that aortic turbulent shear stresses and turbulent kinetic energy are elevated in the patients compared to the healthy subjects. Based on these data, it is concluded that 5D Flow Tensor MRI holds promise to provide comprehensive flow assessment in patients with heart valve diseases.
- 11 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open Access5D Flow Tensor MRI to Efficiently Map Reynolds Stresses of Aortic Blood Flow In-Vivo
Diseased heart valves perturb normal blood flow with a range of hemodynamic and pathologic consequences. In order to better stratify patients with heart valve disease, a comprehensive characterization of blood flow including turbulent contributions is desired. In this work we present a framework to efficiently quantify velocities and Reynolds stresses in the aorta in-vivo. Using a highly undersampled 5D Flow MRI acquisition scheme with locally low-rank image reconstruction, multipoint flow tensor encoding in short and predictable scan times becomes feasible (here, 10 minutes), enabling incorporation of the protocol into clinical workflows. Based on computer simulations, a 19-point 5D Flow Tensor MRI encoding approach is proposed. It is demonstrated that, for in-vivo resolution and signal-to-noise ratios, sufficient accuracy and precision of velocity and turbulent shear stress quantification is achievable. In-vivo proof of concept is demonstrated on patients with a bio-prosthetic heart valve and healthy controls. Results demonstrate that aortic turbulent shear stresses and turbulent kinetic energy are elevated in the patients compared to the healthy subjects. Based on these data, it is concluded that 5D Flow Tensor MRI holds promise to provide comprehensive flow assessment in patients with heart valve diseases.
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 42-13
Multipoint 5D flow cardiovascular magnetic resonance - accelerated cardiac- and respiratory-motion resolved mapping of mean and turbulent velocities
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 42-13
Open AccessMultipoint 5D flow cardiovascular magnetic resonance - accelerated cardiac- and respiratory-motion resolved mapping of mean and turbulent velocities