Charlotte J. Marshall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charlotte J. Marshall has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Doa El-Ansary
Department of Physiotherapy, Royal Melbourne Hospital, Melbourne, Victoria, Australia
3 shared publications - Kim Louise Bennell
The University of Melbourne, Melbourne, Australia
3 shared publications - Rana Shane Hinman
University of Melbourne, Melbourne, Victoria, Australia
3 shared publications Adrian Pranata
School of Health Sciences, Swinburne University of Technology , PO Box 218, Hawthorn, Victoria 3122
2 shared publications- Adrian Pranata
School of Health and Biomedical Science, RMIT University, Bundoora, VIC 3082, Australia
2 shared publications - Amir Takla
Hip Arthroscopy Australia, 21 Erin Street, Richmond 3121, Australia
2 shared publications
Latest Publications
- Open Access
- 22 January 2025
- Published by Oxford University Press (OUP) in Journal of Hip Preservation Surgery
- Vol. 12 (2) , 105-117
Changes in physical impairments in femoroacetabular impingement syndrome following arthroscopic surgery: a systematic review and meta-analysis
Femoroacetabular impingement syndrome (FAIS) is a motion-related condition causing hip pain in young active adults. Physical impairment measures of body function include objective and reproducible measures of hip mobility, muscle power, and movement coordination. Limited data on physical impairments and the effects of arthroscopic surgery exist. The aim of this systematic review was to investigate changes in physical impairments in those with FAIS, pre- and post-arthroscopic surgery. Six databases were searched for English-language studies reporting on pre- and postoperative physical impairments using physical outcome measures. Reporting quality was assessed using the Grading of Recommendations Assessment, Development and Evaluations (GRADE) framework, the Cochrane Risk of Bias tools and Methodological Index for Non-Randomized Studies (MINORS); for pooled data [standardized mean difference (SMD), and 95% confidence intervals (CI)]. Seventeen studies were included (two randomized controlled trials; fifteen pre/postintervention studies), varying from low-critical risk of bias, low-moderate on the MINORS, and very low reporting quality using the GRADE tool. Postoperatively, participants with FAIS walked with a higher peak hip flexion moment [SMD 0.5, 95% CI (0.12–0.88); heterogeneity I2 = 0%, P = .82] and reduced external rotation range [SMD −0.68, 95% CI (−1.34 to −0.01); heterogeneity I2 = 61%, P = .05]. Surgery increased participant hip flexion moment and impulse, hip strength and faster gluteus maximus contraction time. Patients demonstrated reduced hip extension, abduction and adduction angles during walking gait, and peak hip extension moments during gait and squatting. While this review found some physical impairments changed postoperatively, further research into specific subgroups of FAIS would enhance understanding and inform rehabilitation programs and optimize patient outcomes. Level of Evidence: IV (systematic review of III and IV evidence).
- 22 January 2025
- Published by Oxford University Press (OUP) in Journal of Hip Preservation Surgery
- Vol. 12 (2) , 105-117
Open AccessChanges in physical impairments in femoroacetabular impingement syndrome following arthroscopic surgery: a systematic review and meta-analysis
Femoroacetabular impingement syndrome (FAIS) is a motion-related condition causing hip pain in young active adults. Physical impairment measures of body function include objective and reproducible measures of hip mobility, muscle power, and movement coordination. Limited data on physical impairments and the effects of arthroscopic surgery exist. The aim of this systematic review was to investigate changes in physical impairments in those with FAIS, pre- and post-arthroscopic surgery. Six databases were searched for English-language studies reporting on pre- and postoperative physical impairments using physical outcome measures. Reporting quality was assessed using the Grading of Recommendations Assessment, Development and Evaluations (GRADE) framework, the Cochrane Risk of Bias tools and Methodological Index for Non-Randomized Studies (MINORS); for pooled data [standardized mean difference (SMD), and 95% confidence intervals (CI)]. Seventeen studies were included (two randomized controlled trials; fifteen pre/postintervention studies), varying from low-critical risk of bias, low-moderate on the MINORS, and very low reporting quality using the GRADE tool. Postoperatively, participants with FAIS walked with a higher peak hip flexion moment [SMD 0.5, 95% CI (0.12–0.88); heterogeneity I2 = 0%, P = .82] and reduced external rotation range [SMD −0.68, 95% CI (−1.34 to −0.01); heterogeneity I2 = 61%, P = .05]. Surgery increased participant hip flexion moment and impulse, hip strength and faster gluteus maximus contraction time. Patients demonstrated reduced hip extension, abduction and adduction angles during walking gait, and peak hip extension moments during gait and squatting. While this review found some physical impairments changed postoperatively, further research into specific subgroups of FAIS would enhance understanding and inform rehabilitation programs and optimize patient outcomes. Level of Evidence: IV (systematic review of III and IV evidence).
- Open Access
Smartphone Technology to Remotely Measure Postural Sway during Double- and Single-Leg Squats in Adults with Femoroacetabular Impingement and Those with No Hip Pain
Background: The COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test–retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain. Methods: A total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05. Results: The TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62–0.81), 0.85 (95% CI 0.79–0.91), and 0.73 (95% CI 0.62–0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior–posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively). Conclusions: The TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.
Open AccessSmartphone Technology to Remotely Measure Postural Sway during Double- and Single-Leg Squats in Adults with Femoroacetabular Impingement and Those with No Hip Pain
Background: The COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test–retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain. Methods: A total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05. Results: The TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62–0.81), 0.85 (95% CI 0.79–0.91), and 0.73 (95% CI 0.62–0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior–posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively). Conclusions: The TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.
- Open Access
Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory’s 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63–0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85–0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36–0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87–0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
Open AccessValidity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory’s 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63–0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85–0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36–0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87–0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
- 8 December 2021
- Published by SAGE Publications in American Journal of Health Promotion
- Vol. 36 (2) , 367-378
Process Evaluation in Health Communication Media Campaigns: A Systematic Review
Objective . The objective is to examine the scope of health communication media campaign process evaluation methods, findings, and dissemination practices. Data Source . A systematic review of peer-reviewed literature was conducted using database searches. Study Inclusion and Exclusion Criteria . Published studies on process and implementation evaluation of health campaigns with a media component were included. Exclusion criteria included not health, non-empirical, no media campaign, or a focus on other evaluation types. Data Extraction . Articles were assessed for general campaign information, theory use, and details about process evaluation plan and procedures. Data Synthesis . A coding scheme based on 9 process evaluation best practice elements (e.g., fidelity and context) was applied. Process evaluation methods, measures, and reporting themes were synthesized. Results . Among 691 unique records, 46 articles were included. Process evaluation was the main focus for 71.7% of articles, yet only 39.1% reported how process evaluation informed campaign implementation strategy. Articles reported 4.39 elements on average ( SD = 1.99; range 1–9), with reach (87.0%) and recruitment (73.9%) described most frequently, yet reporting was inconsistent. Further, the level of detail in reporting methods, theory, and analysis varied. Conclusions . Process evaluation provides insight about mechanisms and intervening variables that could meaningfully impact interpretations of outcome evaluations; however, process evaluations are less often included in literature. Recommendations for evidence-based process evaluation components to guide evaluation are discussed.
- 8 December 2021
- Published by SAGE Publications in American Journal of Health Promotion
- Vol. 36 (2) , 367-378
Process Evaluation in Health Communication Media Campaigns: A Systematic Review
Objective . The objective is to examine the scope of health communication media campaign process evaluation methods, findings, and dissemination practices. Data Source . A systematic review of peer-reviewed literature was conducted using database searches. Study Inclusion and Exclusion Criteria . Published studies on process and implementation evaluation of health campaigns with a media component were included. Exclusion criteria included not health, non-empirical, no media campaign, or a focus on other evaluation types. Data Extraction . Articles were assessed for general campaign information, theory use, and details about process evaluation plan and procedures. Data Synthesis . A coding scheme based on 9 process evaluation best practice elements (e.g., fidelity and context) was applied. Process evaluation methods, measures, and reporting themes were synthesized. Results . Among 691 unique records, 46 articles were included. Process evaluation was the main focus for 71.7% of articles, yet only 39.1% reported how process evaluation informed campaign implementation strategy. Articles reported 4.39 elements on average ( SD = 1.99; range 1–9), with reach (87.0%) and recruitment (73.9%) described most frequently, yet reporting was inconsistent. Further, the level of detail in reporting methods, theory, and analysis varied. Conclusions . Process evaluation provides insight about mechanisms and intervening variables that could meaningfully impact interpretations of outcome evaluations; however, process evaluations are less often included in literature. Recommendations for evidence-based process evaluation components to guide evaluation are discussed.
- 29 August 2021
- Published by Wiley in Journal of Anatomy
- Vol. 239 (4) , 847-855
Architectural anatomy of the quadriceps and the relationship with muscle strength: An observational study utilising real‐time ultrasound in healthy adults
Quadriceps atrophy and morphological change is a known phenomenon that can impact significantly on strength and functional performance in patients with acute or chronic presentations conditions. Real‐time ultrasound (RTUS) imaging is a noninvasive valid and reliable method of quantifying quadriceps muscle anatomy and architecture. To date, there is a paucity of normative data on the architectural properties of superficial and deep components of the quadriceps muscle group to inform assessment and evaluation of intervention programs. The aims of this study were to (1) quantify the anatomical architectural properties of the quadriceps muscle group (rectus femoris, vastus intermedius, and vastus lateralis) using RTUS in healthy older adults and (2) to determine the relationship between RTUS muscle parameters and measures of quadriceps muscle strength. Thirty middle aged to older males and females (age range 55–79 years; mean age =59.9 ± 7.08 years) were recruited. Quadriceps muscle thickness, cross‐sectional area, pennation angle, and echogenicity were measured using RTUS. Quadriceps strength was measured using hand‐held dynamometry. For the RTUS‐derived quadriceps morphological data, rectus femoris mean results; circumference 9.3 cm; CSA 4.6 cm2; thickness 1.5 cm; echogenicity 100.2 pixels. Vastus intermedius mean results; thickness 1.8 cm; echogenicity 99.1 pixels. Vastus lateralis thickness 1.9 cm; pennation angle 17.3°; fascicle length 7.0 cm. Quadriceps force was significantly correlated only with rectus femoris circumference (r = 0.48, p = 0.007), RF echogenicity (r = 0.38, p = 0.037), VI echogenicity (r = 0.43, p = 0.018), and VL fascicle length (r = 0.43, p = 0.019). Quadriceps force was best predicted by a three‐variable model (adjusted R2 = 0.46, p < 0.001) which included rectus femoris echogenicity (B = 0.43, p = 0.005), vastus lateralis fascicle length (B = 0.33, p = 0.025) and rectus femoris circumference (B = 0.31, p = 0.041). Thus respectively, rectus femoris echogenicity explains 43%, vastus lateralis fascicle length explains 33% and rectus femoris circumference explains 31% of the variance of quadriceps force. The study findings suggest that RTUS measures were reliable and further research is warranted to establish whether these could be used as surrogate measures for quadriceps strength in adults to inform exercise and rehabilitation programs.
- 29 August 2021
- Published by Wiley in Journal of Anatomy
- Vol. 239 (4) , 847-855
Architectural anatomy of the quadriceps and the relationship with muscle strength: An observational study utilising real‐time ultrasound in healthy adults
Quadriceps atrophy and morphological change is a known phenomenon that can impact significantly on strength and functional performance in patients with acute or chronic presentations conditions. Real‐time ultrasound (RTUS) imaging is a noninvasive valid and reliable method of quantifying quadriceps muscle anatomy and architecture. To date, there is a paucity of normative data on the architectural properties of superficial and deep components of the quadriceps muscle group to inform assessment and evaluation of intervention programs. The aims of this study were to (1) quantify the anatomical architectural properties of the quadriceps muscle group (rectus femoris, vastus intermedius, and vastus lateralis) using RTUS in healthy older adults and (2) to determine the relationship between RTUS muscle parameters and measures of quadriceps muscle strength. Thirty middle aged to older males and females (age range 55–79 years; mean age =59.9 ± 7.08 years) were recruited. Quadriceps muscle thickness, cross‐sectional area, pennation angle, and echogenicity were measured using RTUS. Quadriceps strength was measured using hand‐held dynamometry. For the RTUS‐derived quadriceps morphological data, rectus femoris mean results; circumference 9.3 cm; CSA 4.6 cm2; thickness 1.5 cm; echogenicity 100.2 pixels. Vastus intermedius mean results; thickness 1.8 cm; echogenicity 99.1 pixels. Vastus lateralis thickness 1.9 cm; pennation angle 17.3°; fascicle length 7.0 cm. Quadriceps force was significantly correlated only with rectus femoris circumference (r = 0.48, p = 0.007), RF echogenicity (r = 0.38, p = 0.037), VI echogenicity (r = 0.43, p = 0.018), and VL fascicle length (r = 0.43, p = 0.019). Quadriceps force was best predicted by a three‐variable model (adjusted R2 = 0.46, p < 0.001) which included rectus femoris echogenicity (B = 0.43, p = 0.005), vastus lateralis fascicle length (B = 0.33, p = 0.025) and rectus femoris circumference (B = 0.31, p = 0.041). Thus respectively, rectus femoris echogenicity explains 43%, vastus lateralis fascicle length explains 33% and rectus femoris circumference explains 31% of the variance of quadriceps force. The study findings suggest that RTUS measures were reliable and further research is warranted to establish whether these could be used as surrogate measures for quadriceps strength in adults to inform exercise and rehabilitation programs.
- 1 September 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (9) , 1324-1338
Effect of cane use on bone marrow lesion volume in people with medial tibiofemoral knee osteoarthritis: randomized clinical trial
- 1 September 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (9) , 1324-1338
Effect of cane use on bone marrow lesion volume in people with medial tibiofemoral knee osteoarthritis: randomized clinical trial
- 2 August 2019
- Published by Wiley in Musculoskeletal Care
- Vol. 17 (3) , 170-197
The effects of behavioural counselling on the determinants of health behaviour change in adults with chronic musculoskeletal conditions making lifestyle changes: A systematic review and meta‐analysis
Objective: A systematic review and meta‐analysis of controlled trials was carried out to examine the effect of behavioural counselling on determinants of behaviour change in adults with chronic, painful musculoskeletal conditions.Methods: Seven databases were searched up to January 2019. Two reviewers independently screened title/abstracts and full texts. Eligible trials included those including participants over 18 years of age with a chronic, painful musculoskeletal condition, a measurement of at least one behavioural determinant and lifestyle behaviour, and where behavioural counselling was the distinguishing intervention. Two reviewers independently extracted data and assessed for risk of bias using the Cochrane Risk of Bias Tool. Meta‐analyses were conducted, using standardized mean differences and 95% confidence intervals (CIs) when at least two trials examined the same outcome. The quality of the evidence was evaluated using the Grades of Recommendation, Assessment, Development and Evaluation approach.Results: Fourteen unique trials, reported in 16 publications, were included. Low‐quality evidence showed that behavioural counselling has a small effect on increasing self‐reported physical activity (standardized mean difference 0.26; 95% CI 0.00, 0.53). Very‐low‐quality evidence showed that behavioural counselling has a moderate effect on self‐efficacy related to physical activity (standardized mean difference 0.69; 95% CI 0.19, 1.18). Low‐quality evidence suggested that behavioural counselling has no effect on symptoms of depression and anxiety.Conclusions: Behavioural counselling may help to increase self‐reported physical activity levels in adults with chronic painful musculoskeletal conditions. Self‐efficacy may be a behavioural determinant in an underlying causal pathway explaining positive lifestyle change.
- 2 August 2019
- Published by Wiley in Musculoskeletal Care
- Vol. 17 (3) , 170-197
The effects of behavioural counselling on the determinants of health behaviour change in adults with chronic musculoskeletal conditions making lifestyle changes: A systematic review and meta‐analysis
Objective: A systematic review and meta‐analysis of controlled trials was carried out to examine the effect of behavioural counselling on determinants of behaviour change in adults with chronic, painful musculoskeletal conditions.Methods: Seven databases were searched up to January 2019. Two reviewers independently screened title/abstracts and full texts. Eligible trials included those including participants over 18 years of age with a chronic, painful musculoskeletal condition, a measurement of at least one behavioural determinant and lifestyle behaviour, and where behavioural counselling was the distinguishing intervention. Two reviewers independently extracted data and assessed for risk of bias using the Cochrane Risk of Bias Tool. Meta‐analyses were conducted, using standardized mean differences and 95% confidence intervals (CIs) when at least two trials examined the same outcome. The quality of the evidence was evaluated using the Grades of Recommendation, Assessment, Development and Evaluation approach.Results: Fourteen unique trials, reported in 16 publications, were included. Low‐quality evidence showed that behavioural counselling has a small effect on increasing self‐reported physical activity (standardized mean difference 0.26; 95% CI 0.00, 0.53). Very‐low‐quality evidence showed that behavioural counselling has a moderate effect on self‐efficacy related to physical activity (standardized mean difference 0.69; 95% CI 0.19, 1.18). Low‐quality evidence suggested that behavioural counselling has no effect on symptoms of depression and anxiety.Conclusions: Behavioural counselling may help to increase self‐reported physical activity levels in adults with chronic painful musculoskeletal conditions. Self‐efficacy may be a behavioural determinant in an underlying causal pathway explaining positive lifestyle change.
- Open Access
- 15 February 2017
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 97 (5) , 537-549
Impact of Cane Use on Bone Marrow Lesion Volume in People With Medial Knee Osteoarthritis (CUBA Trial)
Background. No effective cure exists for knee osteoarthritis (OA). Low-burden self-management strategies that can slow disease progression are needed. Bone marrow lesions (BMLs) are a source of knee pain and accelerate cartilage loss. Importantly, they may be responsive to biomechanical off-loading treatments. Objective. The study objective is to investigate whether, in people with medial tibiofemoral OA, daily cane use for 12 weeks reduces the volume of medial tibiofemoral BMLs and improves pain, physical function, and health-related quality of life. Design. This study will be an assessor-masked, 2-arm, parallel-group, multisite randomized controlled trial. Setting. The community will serve as the setting for this study. Participants. The study participants will be people who are 50 years old or older and have medial tibiofemoral OA and at least 1 medial tibiofemoral BML. Intervention. The participants will be allocated to either the cane group (using a cane daily whenever walking for 12 weeks) or the control group (not using any gait aid for 12 weeks). Measurements. Outcomes will be measured at baseline and 13 weeks. The primary outcome will be total medial tibiofemoral BML volume measured from magnetic resonance imaging. Secondary outcomes will include BML volume of the medial tibia and/or femur, knee pain overall and on walking, physical function, participant-perceived global change, and health-related quality of life. Additional measures will include physical activity, cointerventions, adverse events, participation, participant demographics, cane training process measures and feasibility, barriers to and facilitators of cane use, and loss to follow-up. Limitations. People who are morbidly obese will not be included because of difficulties with magnetic resonance imaging. Conclusions. The findings of this study will help to determine whether cane use can alter disease progression in people with medial tibiofemoral OA and/or influence clinical symptoms. This study may directly influence clinical guidelines for the management of knee OA.
- 15 February 2017
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 97 (5) , 537-549
Open AccessImpact of Cane Use on Bone Marrow Lesion Volume in People With Medial Knee Osteoarthritis (CUBA Trial)
Background. No effective cure exists for knee osteoarthritis (OA). Low-burden self-management strategies that can slow disease progression are needed. Bone marrow lesions (BMLs) are a source of knee pain and accelerate cartilage loss. Importantly, they may be responsive to biomechanical off-loading treatments. Objective. The study objective is to investigate whether, in people with medial tibiofemoral OA, daily cane use for 12 weeks reduces the volume of medial tibiofemoral BMLs and improves pain, physical function, and health-related quality of life. Design. This study will be an assessor-masked, 2-arm, parallel-group, multisite randomized controlled trial. Setting. The community will serve as the setting for this study. Participants. The study participants will be people who are 50 years old or older and have medial tibiofemoral OA and at least 1 medial tibiofemoral BML. Intervention. The participants will be allocated to either the cane group (using a cane daily whenever walking for 12 weeks) or the control group (not using any gait aid for 12 weeks). Measurements. Outcomes will be measured at baseline and 13 weeks. The primary outcome will be total medial tibiofemoral BML volume measured from magnetic resonance imaging. Secondary outcomes will include BML volume of the medial tibia and/or femur, knee pain overall and on walking, physical function, participant-perceived global change, and health-related quality of life. Additional measures will include physical activity, cointerventions, adverse events, participation, participant demographics, cane training process measures and feasibility, barriers to and facilitators of cane use, and loss to follow-up. Limitations. People who are morbidly obese will not be included because of difficulties with magnetic resonance imaging. Conclusions. The findings of this study will help to determine whether cane use can alter disease progression in people with medial tibiofemoral OA and/or influence clinical symptoms. This study may directly influence clinical guidelines for the management of knee OA.