Zhixiang Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhixiang Jia has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Weidong Cao
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
3 shared publications - Qiqi Zhang
Research Institute of Fluid Engineering Equipment Technology, Jiangsu University, Zhenjiang 212013, China
2 shared publications - Xinyu Yang
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
1 shared publication
Latest Publications
- Open Access
- 2 May 2022
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 10 (5) , 619
Numerical Simulation of Cavitation Flow in a Low Specific-Speed Centrifugal Pump with Different Diameters of Balance Holes
In order to study the influence of a balance hole’s diameter on the cavitation performance of low specific-speed centrifugal pumps, a centrifugal pump with a specific speed of 0.301 was selected as the research object. The pump’s cavitation performance, distribution of cavitation vapor in the impeller, and axial force on the impeller were studied with the change in diameters of balance holes. The results show that with the increase in the diameter of balance holes, the cavitation number σ3% of the low specific-speed centrifugal pump became small, the pressure in the mechanical seal cavity dropped gradually, and the flow velocity in balance holes was reduced. As cavitation occurred in the impeller, the diameter of balance holes not only affected the absolute value of the axial force but also affected the direction of the axial force.
- 2 May 2022
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 10 (5) , 619
Open AccessNumerical Simulation of Cavitation Flow in a Low Specific-Speed Centrifugal Pump with Different Diameters of Balance Holes
In order to study the influence of a balance hole’s diameter on the cavitation performance of low specific-speed centrifugal pumps, a centrifugal pump with a specific speed of 0.301 was selected as the research object. The pump’s cavitation performance, distribution of cavitation vapor in the impeller, and axial force on the impeller were studied with the change in diameters of balance holes. The results show that with the increase in the diameter of balance holes, the cavitation number σ3% of the low specific-speed centrifugal pump became small, the pressure in the mechanical seal cavity dropped gradually, and the flow velocity in balance holes was reduced. As cavitation occurred in the impeller, the diameter of balance holes not only affected the absolute value of the axial force but also affected the direction of the axial force.
- Open Access
The Simulation of Vortex Structures Induced by Different Local Vibrations at the Wall in a Flat-Plate Laminar Boundary Layer
The compact finite difference scheme on non-uniform meshes and the Fourier spectral hybrid method are used to directly simulate the evolution of vortex structures in a laminar boundary layer over a flat plate. To this end, two initial local vibration disturbances, namely, the positive–negative and the negative–positive models, at the wall were adopted. The numerical results show that the maximum amplitudes of vortex structures experience a process of linear growth and nonlinear rapid growth. The vertical disturbance velocity and mean flow shear and the derivative term of the stream-wise disturbance velocity and the span-wise disturbance velocity, are important factors for vortex structure development; the high- and low-speed stripe and the stream-wise vortex are consistent with structures seen in full turbulence. The maximum amplitude of the negative–positive model grows more quickly than that of the negative–positive model, and the detailed vortex structures are different for the two models. The mean flow profiles both become plump, which leads to the instability of the laminar boundary layer. The way in which the disturbance is generated with different local vibrations influences the dynamics of vortex structures in a laminar boundary layer.
Open AccessThe Simulation of Vortex Structures Induced by Different Local Vibrations at the Wall in a Flat-Plate Laminar Boundary Layer
The compact finite difference scheme on non-uniform meshes and the Fourier spectral hybrid method are used to directly simulate the evolution of vortex structures in a laminar boundary layer over a flat plate. To this end, two initial local vibration disturbances, namely, the positive–negative and the negative–positive models, at the wall were adopted. The numerical results show that the maximum amplitudes of vortex structures experience a process of linear growth and nonlinear rapid growth. The vertical disturbance velocity and mean flow shear and the derivative term of the stream-wise disturbance velocity and the span-wise disturbance velocity, are important factors for vortex structure development; the high- and low-speed stripe and the stream-wise vortex are consistent with structures seen in full turbulence. The maximum amplitude of the negative–positive model grows more quickly than that of the negative–positive model, and the detailed vortex structures are different for the two models. The mean flow profiles both become plump, which leads to the instability of the laminar boundary layer. The way in which the disturbance is generated with different local vibrations influences the dynamics of vortex structures in a laminar boundary layer.
- Open Access
Near-Wall Flow Characteristics of a Centrifugal Impeller with Low Specific Speed
In order to study the near-wall region flow characteristics in a low-specific-speed centrifugal impeller, based on ANSYS-CFX 15.0 software, Reynolds averaged Navier-Stokes (RANS) methods and renormalization group (RNG) k-ɛ turbulence model were used to simulate the whole flow field of a low specific speed centrifugal pump with five blades under different flow rates. Simulation results of external characteristics of the pump were in good agreement with experimental results. Profiles were set on the pressure side and suction side of impeller blades at the distances of 0.5 mm and 2 mm, respectively, to study the distributions of flow characteristics near the wall region of five groups of blades. The results show that the near-wall region flow characteristics of five groups of blades were similar, but the static pressure, relative velocity, cross flow velocity, and turbulent kinetic energy of profiles on the pressure side were quite different to those on the suction sides, and these characteristics also changed with the alternation of flow rate. As the flow rate was 13 m3/h or 20 m3/h, within the radius range of 40 to 50 mm, there was an extent of negative relative velocity of the profiles on the pressure side, and a counter-current happened not on the suction side, but on the pressure side in the low specific speed centrifugal impeller. The flow characteristics of profiles at the distances of 0.5 mm and 2 mm also showed a small difference.
Open AccessNear-Wall Flow Characteristics of a Centrifugal Impeller with Low Specific Speed
In order to study the near-wall region flow characteristics in a low-specific-speed centrifugal impeller, based on ANSYS-CFX 15.0 software, Reynolds averaged Navier-Stokes (RANS) methods and renormalization group (RNG) k-ɛ turbulence model were used to simulate the whole flow field of a low specific speed centrifugal pump with five blades under different flow rates. Simulation results of external characteristics of the pump were in good agreement with experimental results. Profiles were set on the pressure side and suction side of impeller blades at the distances of 0.5 mm and 2 mm, respectively, to study the distributions of flow characteristics near the wall region of five groups of blades. The results show that the near-wall region flow characteristics of five groups of blades were similar, but the static pressure, relative velocity, cross flow velocity, and turbulent kinetic energy of profiles on the pressure side were quite different to those on the suction sides, and these characteristics also changed with the alternation of flow rate. As the flow rate was 13 m3/h or 20 m3/h, within the radius range of 40 to 50 mm, there was an extent of negative relative velocity of the profiles on the pressure side, and a counter-current happened not on the suction side, but on the pressure side in the low specific speed centrifugal impeller. The flow characteristics of profiles at the distances of 0.5 mm and 2 mm also showed a small difference.