Xinpei Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xinpei Song has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ghulam Destgeer
Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany
6 shared publications - Mehmet Akif Sahin
Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany
4 shared publications Tianning Chen
School of Mechanical Engineering, Xi'an Jiaotong University, Xi’an 710049, Xi'an, Shannxi, 710049, CHINA
4 shared publicationsJian Zhu
State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
3 shared publications- Dino Di Carlo
Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA
2 shared publications Liusu Wang
Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215000, China
2 shared publications
Latest Publications
- Open Access
Lab on a Capillary: Instrument-Free Compartmentalization Using Photopatterned Hydrogel Rings Embedded inside a Glass Capillary for Amplified Bioassays
Sensitive and low-cost protein biomarker detection is critical for disease diagnosis. Advanced microfluidic systems can generate miniature reaction compartments for a high-sensitivity assay. However, these platforms often require external instruments, skilled operators, and complex setups. Here, we develop a Lab on a Capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system. During sample loading and unloading steps, nanoliter-scale aqueous droplets (torodrops) are spontaneously formed around the hydrogel rings, creating isolated reaction compartments without the need for external instruments or an immiscible oil phase. The LabCap platform enables quantitative detection of clinically relevant biomarkers, including C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). By adjusting the incubation protocol, assay speed and sensitivity can be tuned to meet different analytical requirements. A periodic medium exchange protocol enables biomarker detection at concentrations as low as 1 ng/mL, whereas prolonged static incubation extends detection to 0.1 ng/mL. In addition, LabCap offers practical advantages, including low fabrication cost (<€1 per device), low reagent consumption (<100 μL per assay step), and minimal wash-buffer usage (1 mL). These results demonstrate that LabCap is a simple, cost-effective, and versatile platform for biomarker detection.
Open AccessLab on a Capillary: Instrument-Free Compartmentalization Using Photopatterned Hydrogel Rings Embedded inside a Glass Capillary for Amplified Bioassays
Sensitive and low-cost protein biomarker detection is critical for disease diagnosis. Advanced microfluidic systems can generate miniature reaction compartments for a high-sensitivity assay. However, these platforms often require external instruments, skilled operators, and complex setups. Here, we develop a Lab on a Capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system. During sample loading and unloading steps, nanoliter-scale aqueous droplets (torodrops) are spontaneously formed around the hydrogel rings, creating isolated reaction compartments without the need for external instruments or an immiscible oil phase. The LabCap platform enables quantitative detection of clinically relevant biomarkers, including C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). By adjusting the incubation protocol, assay speed and sensitivity can be tuned to meet different analytical requirements. A periodic medium exchange protocol enables biomarker detection at concentrations as low as 1 ng/mL, whereas prolonged static incubation extends detection to 0.1 ng/mL. In addition, LabCap offers practical advantages, including low fabrication cost (<€1 per device), low reagent consumption (<100 μL per assay step), and minimal wash-buffer usage (1 mL). These results demonstrate that LabCap is a simple, cost-effective, and versatile platform for biomarker detection.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
Lab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays
A capillary, a hydrogel pattern and a piece of tissue paper replace the pumps, chips and oil normally required to compartmentalize an amplified immunoassay, detecting CRP and NT-proBNP below 1 ng mL −1 .
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
Open AccessLab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays
A capillary, a hydrogel pattern and a piece of tissue paper replace the pumps, chips and oil normally required to compartmentalize an amplified immunoassay, detecting CRP and NT-proBNP below 1 ng mL −1 .
- Open Access
- 24 December 2024
- Published by Wiley in Advanced Science
- Vol. 12 (12) , e2411014
Tunable Picoliter‐Scale Dropicle Formation Using Amphiphilic Microparticles with Patterned Hydrophilic Patches
Microparticle‐templated droplets or dropicles have recently gained interest in the fields of diagnostic immunoassays, single‐cell analysis, and digital molecular biology. Amphiphilic particles have been shown to spontaneously capture aqueous droplets within their cavities upon mixing with an immiscible oil phase, where each particle templates a single droplet. Here, an amphiphilic microparticle with four discrete hydrophilic patches embedded at the inner corners of a square‐shaped hydrophobic outer ring of the particle (4C particle) is fabricated. Three dimensional computational fluid dynamics simulations predict droplet formation dynamics and differing equilibrium conditions depending on the patterning configuration. Experiments recapitulate equilibrium conditions, enabling tunable dropicle configurations with reproducible volumes down to ≈200 pL templated by the amphiphilic particles. The dropicle configurations depend predominantly on the size of the hydrophilic patches of the 4C particles. This validates that the modeling approach can inform the design of dropicles with varying volumes and numbers per particle, which can be harnessed in new amplified bioassays for greater sensitivity, dynamic range, and statistical confidence.
- 24 December 2024
- Published by Wiley in Advanced Science
- Vol. 12 (12) , e2411014
Open AccessTunable Picoliter‐Scale Dropicle Formation Using Amphiphilic Microparticles with Patterned Hydrophilic Patches
Microparticle‐templated droplets or dropicles have recently gained interest in the fields of diagnostic immunoassays, single‐cell analysis, and digital molecular biology. Amphiphilic particles have been shown to spontaneously capture aqueous droplets within their cavities upon mixing with an immiscible oil phase, where each particle templates a single droplet. Here, an amphiphilic microparticle with four discrete hydrophilic patches embedded at the inner corners of a square‐shaped hydrophobic outer ring of the particle (4C particle) is fabricated. Three dimensional computational fluid dynamics simulations predict droplet formation dynamics and differing equilibrium conditions depending on the patterning configuration. Experiments recapitulate equilibrium conditions, enabling tunable dropicle configurations with reproducible volumes down to ≈200 pL templated by the amphiphilic particles. The dropicle configurations depend predominantly on the size of the hydrophilic patches of the 4C particles. This validates that the modeling approach can inform the design of dropicles with varying volumes and numbers per particle, which can be harnessed in new amplified bioassays for greater sensitivity, dynamic range, and statistical confidence.
- Open Access
Tunable picoliter-scale dropicle formation using amphiphilic microparticles with patterned hydrophilic patches
Microparticle-templated droplets or dropicles have recently gained interest in the fields of diagnostic immunoassays, single-cell analysis, and digital molecular biology. Amphiphilic particles have been shown to spontaneously capture aqueous droplets within their cavities upon mixing with an immiscible oil phase, where each particle templates a single droplet. Here, we fabricated an amphiphilic microparticle with four discrete hydrophilic patches embedded at the inner corners of a square-shaped hydrophobic outer ring of the particle (4C particle). 3D computational fluid dynamics simulations predicted droplet formation dynamics and differing equilibrium conditions depending on the patterning configuration. Experiments recapitulated equilibrium conditions enabling tunable dropicle configurations with reproducible volumes down to ∼200pL templated by the amphiphilic particles. The dropicle configurations depended predominantly on the size of the hydrophilic patches of the 4C particles. This validated modeling approach can inform the design of dropicles with varying volumes and numbers per particle, which can be harnessed in new amplified bioassays for greater sensitivity, dynamic range, and statistical confidence.
Open AccessTunable picoliter-scale dropicle formation using amphiphilic microparticles with patterned hydrophilic patches
Microparticle-templated droplets or dropicles have recently gained interest in the fields of diagnostic immunoassays, single-cell analysis, and digital molecular biology. Amphiphilic particles have been shown to spontaneously capture aqueous droplets within their cavities upon mixing with an immiscible oil phase, where each particle templates a single droplet. Here, we fabricated an amphiphilic microparticle with four discrete hydrophilic patches embedded at the inner corners of a square-shaped hydrophobic outer ring of the particle (4C particle). 3D computational fluid dynamics simulations predicted droplet formation dynamics and differing equilibrium conditions depending on the patterning configuration. Experiments recapitulated equilibrium conditions enabling tunable dropicle configurations with reproducible volumes down to ∼200pL templated by the amphiphilic particles. The dropicle configurations depended predominantly on the size of the hydrophilic patches of the 4C particles. This validated modeling approach can inform the design of dropicles with varying volumes and numbers per particle, which can be harnessed in new amplified bioassays for greater sensitivity, dynamic range, and statistical confidence.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Numerical simulation and analysis of droplet formation within an amphiphilic particle
An instrument-free particle-templated droplet formation can be achieved upon simple mixing of amphiphilic particles with aqueous and oil phases in a well plate by using a common lab pipette. Here, a two-dimensional, two-phase flow model was established using a finite element method to mimic the droplet formation within a concentric amphiphilic particle, which consisted of an outer hydrophobic layer and an inner hydrophilic layer. Immiscible water and oil phases selectively interacted with the hydrophilic and hydrophobic layers of the particle, respectively, to form an isolated aqueous compartment within a cavity. Three extreme models were also simulated, including completely hydrophilic, completely hydrophobic, and oppositely amphiphilic particle, which indicated that a right order of the particle layers was necessary to capture the droplet inside the cavity. Moreover, we performed a systematic study of particle-templated droplet formation by varying the individual layer thicknesses of particle, particle height, interfacial tension between water and oil, contact angle of interface with different surfaces, velocity of incoming oil media, and distance between neighboring particles. The volume fraction of water droplet trapped within the target cavity region was calculated to characterize the droplet formation. Our work will help to optimize the particle fabrication process, predict the experiment droplet formation, and explain the physical mechanism underlying compartmentalization phenomena.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Numerical simulation and analysis of droplet formation within an amphiphilic particle
An instrument-free particle-templated droplet formation can be achieved upon simple mixing of amphiphilic particles with aqueous and oil phases in a well plate by using a common lab pipette. Here, a two-dimensional, two-phase flow model was established using a finite element method to mimic the droplet formation within a concentric amphiphilic particle, which consisted of an outer hydrophobic layer and an inner hydrophilic layer. Immiscible water and oil phases selectively interacted with the hydrophilic and hydrophobic layers of the particle, respectively, to form an isolated aqueous compartment within a cavity. Three extreme models were also simulated, including completely hydrophilic, completely hydrophobic, and oppositely amphiphilic particle, which indicated that a right order of the particle layers was necessary to capture the droplet inside the cavity. Moreover, we performed a systematic study of particle-templated droplet formation by varying the individual layer thicknesses of particle, particle height, interfacial tension between water and oil, contact angle of interface with different surfaces, velocity of incoming oil media, and distance between neighboring particles. The volume fraction of water droplet trapped within the target cavity region was calculated to characterize the droplet formation. Our work will help to optimize the particle fabrication process, predict the experiment droplet formation, and explain the physical mechanism underlying compartmentalization phenomena.
- Open Access
Numerical simulation and analysis of droplet formation within an amphiphilic particle
An instrument-free particle-templated droplet formation can be achieved upon simple mixing of amphiphilic particles with aqueous and oil phases in a well plate by using a common lab pipette. Here, a two-dimensional, two-phase flow model was established using a finite element method to mimic the droplet formation within a concentric amphiphilic particle, which consisted of an outer hydrophobic layer and an inner hydrophilic layer. Immiscible water and oil phases selectively interacted with the hydrophilic and hydrophobic layers of the particle, respectively, to form an isolated aqueous compartment within a cavity. Three extreme models were also simulated, including completely hydrophilic, completely hydrophobic, and oppositely amphiphilic particle, which indicated that a right order of the particle layers was necessary to capture the droplet inside the cavity. Moreover, we performed a systematic study of particle-templated droplet formation by varying the individual layer thicknesses of particle, particle height, interfacial tension between water and oil, contact angle of interface with different surfaces, velocity of incoming oil media, and distance between neighboring particles. The volume fraction of water droplet trapped within the target cavity region was calculated to characterize the droplet formation. Our work will help to optimize the particle fabrication process, predict the experiment droplet formation, and explain the physical mechanism underlying compartmentalization phenomena.
Open AccessNumerical simulation and analysis of droplet formation within an amphiphilic particle
An instrument-free particle-templated droplet formation can be achieved upon simple mixing of amphiphilic particles with aqueous and oil phases in a well plate by using a common lab pipette. Here, a two-dimensional, two-phase flow model was established using a finite element method to mimic the droplet formation within a concentric amphiphilic particle, which consisted of an outer hydrophobic layer and an inner hydrophilic layer. Immiscible water and oil phases selectively interacted with the hydrophilic and hydrophobic layers of the particle, respectively, to form an isolated aqueous compartment within a cavity. Three extreme models were also simulated, including completely hydrophilic, completely hydrophobic, and oppositely amphiphilic particle, which indicated that a right order of the particle layers was necessary to capture the droplet inside the cavity. Moreover, we performed a systematic study of particle-templated droplet formation by varying the individual layer thicknesses of particle, particle height, interfacial tension between water and oil, contact angle of interface with different surfaces, velocity of incoming oil media, and distance between neighboring particles. The volume fraction of water droplet trapped within the target cavity region was calculated to characterize the droplet formation. Our work will help to optimize the particle fabrication process, predict the experiment droplet formation, and explain the physical mechanism underlying compartmentalization phenomena.
- 23 August 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (8) , 085101
Frequency band-selected one-way topological edge mode via acoustic metamaterials and metasurface
Single functionality and fixed operating bands maintain the key drawbacks in existing acoustic topological insulators. Here, we report an acoustic system to realize the frequency band-selected one-way topological edge state transmission. The system is combined with a double-layer sonic crystal and a lossy acoustic metasurface. The topological insulators enable the frequency band-selected effect by separating and nesting the two layers of the sonic crystals. The sound one-way transmission effect is ensured by the metasurface. Consequently, the one-way topological edge state transmission is realized, and the operating band of the system can be shifted between two distinct ranges. Our work may have potential in the areas where multiple frequency bands are required, such as sound isolation, acoustic switch, mechanical imaging, acoustic split, and integrated acoustic communications.
- 23 August 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (8) , 085101
Frequency band-selected one-way topological edge mode via acoustic metamaterials and metasurface
Single functionality and fixed operating bands maintain the key drawbacks in existing acoustic topological insulators. Here, we report an acoustic system to realize the frequency band-selected one-way topological edge state transmission. The system is combined with a double-layer sonic crystal and a lossy acoustic metasurface. The topological insulators enable the frequency band-selected effect by separating and nesting the two layers of the sonic crystals. The sound one-way transmission effect is ensured by the metasurface. Consequently, the one-way topological edge state transmission is realized, and the operating band of the system can be shifted between two distinct ranges. Our work may have potential in the areas where multiple frequency bands are required, such as sound isolation, acoustic switch, mechanical imaging, acoustic split, and integrated acoustic communications.
- 6 April 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (25) , 255302
Observation of frequency band-switchable topological edge modes using a 2 bit coding acoustic topological insulator
Here, the frequency band-switchable topologically protected edge state transport is realized in simulation and experiment based on a 2 bit coding acoustic topological insulator that consists of two layers of sonic crystals arrayed by the Helmholtz resonant triangle-lattice scatters with two distinct rotation angles. The acoustic topological phase transition is revealed and the gapless frequency bands are predicted. Experimentally measured transmission spectra and simulated pressure fields show good agreement with the predicted results. The error between the measured and the predicted results is illustrated by introducing a slit into the nested scatters, which is comparable to the manufacturing accuracy of the commercial 3D printer. Our work provides a simple method of coding to achieve the frequency-switchable acoustic topological edge modes, and paves a promising way to design the intelligent, programmable, and flexible acoustic devices.
- 6 April 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (25) , 255302
Observation of frequency band-switchable topological edge modes using a 2 bit coding acoustic topological insulator
Here, the frequency band-switchable topologically protected edge state transport is realized in simulation and experiment based on a 2 bit coding acoustic topological insulator that consists of two layers of sonic crystals arrayed by the Helmholtz resonant triangle-lattice scatters with two distinct rotation angles. The acoustic topological phase transition is revealed and the gapless frequency bands are predicted. Experimentally measured transmission spectra and simulated pressure fields show good agreement with the predicted results. The error between the measured and the predicted results is illustrated by introducing a slit into the nested scatters, which is comparable to the manufacturing accuracy of the commercial 3D printer. Our work provides a simple method of coding to achieve the frequency-switchable acoustic topological edge modes, and paves a promising way to design the intelligent, programmable, and flexible acoustic devices.
- 7 August 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (44) , 44LT01
Switchable asymmetric acoustic transmission based on topological insulator and metasurfaces
Dynamically switching the symmetric and asymmetric acoustic transmission (AAT) is significant in sound manipulation. In this paper, we present the design of switchable AAT in a certain frequency band, which is composed of an acoustic valley hall (AVH) topological insulator and acoustic metasurface (AMS). The underlying mechanism of AAT is attributed to the valley-selective excitation of AVH edge modes and the arbitrary refraction angle controls of the AMS. The acoustic transmission can only occur when the AVH edge modes are excited by controlling the direction of the incident sound waves with the help of AMS. By moving the AMS, the device can shift from symmetric transmission to asymmetric transmission within the designed frequency band. Importantly, the acoustic transmission through the device is topologically protected, which is robust to bends and defects. The AMS based on the spiral-coiling structure is chosen to reach a high acoustic transmission. The performance of switchable AAT is validated with full-wave simulations. Our work may open a new method for introducing the advantages of topological insulators to AAT.
- 7 August 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (44) , 44LT01
Switchable asymmetric acoustic transmission based on topological insulator and metasurfaces
Dynamically switching the symmetric and asymmetric acoustic transmission (AAT) is significant in sound manipulation. In this paper, we present the design of switchable AAT in a certain frequency band, which is composed of an acoustic valley hall (AVH) topological insulator and acoustic metasurface (AMS). The underlying mechanism of AAT is attributed to the valley-selective excitation of AVH edge modes and the arbitrary refraction angle controls of the AMS. The acoustic transmission can only occur when the AVH edge modes are excited by controlling the direction of the incident sound waves with the help of AMS. By moving the AMS, the device can shift from symmetric transmission to asymmetric transmission within the designed frequency band. Importantly, the acoustic transmission through the device is topologically protected, which is robust to bends and defects. The AMS based on the spiral-coiling structure is chosen to reach a high acoustic transmission. The performance of switchable AAT is validated with full-wave simulations. Our work may open a new method for introducing the advantages of topological insulators to AAT.
- 30 September 2019
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 33 (24)
Broadband acoustic cloaking and disguising with full-rangle incident angles based on reconfigurable metasurface
- 30 September 2019
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 33 (24)
Broadband acoustic cloaking and disguising with full-rangle incident angles based on reconfigurable metasurface