MSMehmet Akif Sahin

Mehmet Akif Sahin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mehmet Akif Sahin has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Ghulam Destgeer

    Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany

    13 shared publications
  • Muhammad Usman Akhtar

    Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany

    5 shared publications
  • Xinpei Song

    Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215000, China

    4 shared publications
  • Daniel Stoecklein

    Department of Mechanical Engineering Rose‐Hulman Institute of Technology Terre Haute IN USA

    3 shared publications
  • Dino Di Carlo

    Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA

    3 shared publications
  • Helen Werner

    Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich

    3 shared publications

Latest Publications

  • Open Access

    3D Hydrodynamic Flow Lithography

    by Yiying Zou, Mehmet Akif Sahin, Muhammad Zia Ullah Khan, Muhammad Usman Akhtar, Daniel Stoecklein, Ghulam Destgeer

    Continuous‐ and stop‐flow lithography are widely used to fabricate multi‐dimensional microstructures whose cross‐sectional morphology is dictated by the flow profile of multiple co‐flowing streams. Here, we introduce three‐dimensional hydrodynamic flow lithography (3D HFL), a platform for programmable generation of multi‐layered flow profiles and their conversion into solid anisotropic microparticles and fibers. By strategically combining variable inlet, intra‐channel pillar, and outlet configurations, we achieve precise and versatile sculpting of flow profiles under non‐inertial conditions, as validated by computational fluid dynamics simulations and experimental production of microparticles. The flow‐sculpting devices are fabricated using low‐cost 3D‐printed molds to cast PDMS channels with precisely aligned inlets and complex geometries that are difficult or impossible to achieve with conventional soft lithography. We demonstrate anisotropic multi‐material microparticles and fibers tailored for specific applications: amphiphilic particles for uniform microdroplet capture, biocompatible patterned hydrogels for controlled cell adhesion, and dual‐layer fibers for temperature sensing. To support this, we develope a rapid, predictive software tool for flow‐profile design and 3D particle engineering. Ultimately, 3D HFL integrates straightforward device fabrication, accessible computational design, and high‐throughput production into a scalable platform for creating microstructures with tailored geometries, compositions, and functionalities.


  • Open Access

    Lab on a Capillary: Instrument-Free Compartmentalization Using Photopatterned Hydrogel Rings Embedded inside a Glass Capillary for Amplified Bioassays

    by Yimin Yang, Muhammad Usman Akhtar, Mehmet Akif Sahin, Yibo Huang, Liusu Wang, Xinpei Song, Ghulam Destgeer

    Sensitive and low-cost protein biomarker detection is critical for disease diagnosis. Advanced microfluidic systems can generate miniature reaction compartments for a high-sensitivity assay. However, these platforms often require external instruments, skilled operators, and complex setups. Here, we develop a Lab on a Capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system. During sample loading and unloading steps, nanoliter-scale aqueous droplets (torodrops) are spontaneously formed around the hydrogel rings, creating isolated reaction compartments without the need for external instruments or an immiscible oil phase. The LabCap platform enables quantitative detection of clinically relevant biomarkers, including C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). By adjusting the incubation protocol, assay speed and sensitivity can be tuned to meet different analytical requirements. A periodic medium exchange protocol enables biomarker detection at concentrations as low as 1 ng/mL, whereas prolonged static incubation extends detection to 0.1 ng/mL. In addition, LabCap offers practical advantages, including low fabrication cost (<€1 per device), low reagent consumption (<100 μL per assay step), and minimal wash-buffer usage (1 mL). These results demonstrate that LabCap is a simple, cost-effective, and versatile platform for biomarker detection.

  • Open Access

    Acoustofluidic Active Flow Sculpting Enables Dynamic, Reconfigurable Cross-Sectional Patterning

    by Mehmet Akif Sahin, Seyedmohammadali Hosseinian, Anna Cernina, Linus Eing, Daniel Stoecklein, Jinsoo Park, Ghulam Destgeer

    Microstructures created with flow lithography exhibit distinct functionality depending on the shape and composition of the precursor fluids, enabling applications from tissue engineering to anti-counterfeiting. However, current techniques rely on static nozzle geometries or passive hydrodynamic focusing, which commit to a fixed structure and limit dynamic reconfiguration of material architecture during fabrication. Here, we introduce ActiSculpt, an acoustofluidic platform that replaces in-channel physical structures with programmable, electronically driven acoustic streaming. By exploiting the interplay between laminar stability and acoustic streaming, we decouple deterministic fluid deformation from chaotic mixing, achieving a continuous cross-sectional displacement sensitivity of ~15 um/V. We demonstrate the generation of a diverse library of hydrogel particles whose cross-sectional moments of inertia are tunable up to 5.5-fold, establishing a direct, geometry-mediated link between acoustic parameters and the moments that govern bending and torsional rigidity. We further demonstrate continuous fiber fabrication in which acoustic parameters are varied in real time, encoding structural variation along the fiber's length. The result is a platform that overcomes the one-device, one-geometry constraint of existing techniques, enabling not only on-demand reconfiguration between fabrication runs but also real-time control of material architecture. This spatiotemporal control establishes a new design axis for soft-material manufacturing.

  • Open Access

    Lab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays

    by Yimin Yang, Muhammad Usman Akhtar, Mehmet Akif Sahin, Yibo Huang, Liusu Wang, Xinpei Song, Ghulam Destgeer

    A capillary, a hydrogel pattern and a piece of tissue paper replace the pumps, chips and oil normally required to compartmentalize an amplified immunoassay, detecting CRP and NT-proBNP below 1 ng mL −1 .

  • Open Access

    3D Hydrodynamic Flow Lithography

    by Yiying Zou, Mehmet Akif Sahin, Muhammad Zia Ullah Khan, Muhammad Usman Akhtar, Daniel Stoecklein, Ghulam Destgeer

    Continuous- and stop-flow lithography has been widely used for the fabrication of ingenious multi-dimensional microstructures, including fibers and microparticles. The flow profile of multiple co-flowing streams during the process, as one of the dimensions, dictates the cross-sectional morphology of the microstructures. Here, we introduce a three-dimensional hydrodynamic flow lithography (3D HFL) approach that enables rapid and programmable generation of desired flow profiles and their conversion into solid microstructures. By strategically combining multiple flow sculpting strategies, including variable inlet configurations, intra-channel pillar configurations, and outlet configurations, we achieved precise and versatile control over flow sculpting, as validated by computational fluid dynamics simulations and experimental production of microparticles and fibers, offering unparalleled design flexibility. Importantly, the flow sculpting device is fabricated using low-cost 3D-printed molds to cast PDMS channels with precisely aligned inlets and complex geometries that are difficult or impossible to achieve using conventional soft lithography. Our 3D HFL approach effectively overcomes the limitations of existing microfabrication techniques in device complexity, structural diversity, multi-material integration, and production throughput. Furthermore, we demonstrated the capability of this platform to produce anisotropic multi-material microparticles and fibers tailored for specific applications, such as amphiphilic particles for uniform microdroplet capture, biocompatible patterned hydrogels for controlled cell adhesion, and dual-layer fibers for temperature sensing. The simplicity of device fabrication, combined with the broad design flexibility, establishes this platform as a scalable, high-throughput, and versatile solution for engineering anisotropic microparticles and fibers with tailored functionalities, providing powerful tools for a wide range of downstream fields.

  • Droplet acoustofluidics: Recent progress and challenges

    by Mushtaq Ali, Woohyuk Kim, Muhammad Soban Khan, Mehmet Akif Sahin, Ghulam Destgeer, Jinsoo Park

    Acoustofluidics, offering contact-free and precise manipulation of micro-objects, has emerged as a transformative tool for various biological and medical applications. In recent years, significant advancements have been made in droplet manipulation using acoustic waves. This review provides an in-depth exploration of acoustofluidic techniques for droplet manipulation, presenting a balanced perspective on the role of this versatile platform across diverse applications. The paper begins by introducing the underlying mechanism of acoustic forces acting on the droplets, followed by a comprehensive discussion of acoustofluidic techniques tailored for essential unit operations, such as droplet generation, separation, merging, splitting, steering, trapping, in-droplet sample manipulation, sample control within sessile droplets, and digital acoustofluidics. Finally, the prospects and limitations of acoustofluidics for droplet manipulations are also discussed, suggesting the future direction of droplet acoustofluidics research.


  • Open Access

    Stopping a Multilayered Co‐Axial Flow in a 3D Printed Microchannel with Cascaded Nozzles

    by Helen Werner, Ebrahim TaiediNejad, Mehmet Akif Sahin, Moritz Leuthner, Peer Erfle, Oliver Hayden, Andreas Dietzel, Ghulam Destgeer

    Three different flow control methods are investigated to stop a multilayered flow inside a 3D‐printed microfluidic channel by bringing the average flow velocity from >100 mm s−1 to below a critical velocity of 200 µm s−1 within a certain delay time td of ≈2 s. A sequence of three concentric nozzles is 3D printed (≈75 µm) and embedded serially inside the microchannel (≈200 µm) using a two‐photon polymerization method. The 3D printed device produces a structured coaxial flow of four streams with individual layer thicknesses of O(10 µm). The pressure gradient across the fluidic circuit is removed, from > 2 bar to ≈0 bar, to stop the multilayered flow and measure td to assess the performance of the three stop‐flow methods. During the stop‐flow phase, an inhomogeneous pressure gradient across different inlets resulted in a backflow to inlet channels with lower pressures. The fluidic capacitance is systematically managed to minimize a dimensionless backflow index (BFI) value from ≈0.3 (worst case) to ≈0.03 (best case) for a total flow rate ranging from 16.8 to 168 µL min−1. Finally, the best stop‐flow conditions are recommended, which resulted in a minimal delay time of td ≈ 2 s and a BFI < 0.05.


  • Open Access

    Tunable Picoliter‐Scale Dropicle Formation Using Amphiphilic Microparticles with Patterned Hydrophilic Patches

    by Xinpei Song, Shreya Udani, Mengxing Ouyang, Mehmet Akif Sahin, Dino Di Carlo, Ghulam Destgeer

    Microparticle‐templated droplets or dropicles have recently gained interest in the fields of diagnostic immunoassays, single‐cell analysis, and digital molecular biology. Amphiphilic particles have been shown to spontaneously capture aqueous droplets within their cavities upon mixing with an immiscible oil phase, where each particle templates a single droplet. Here, an amphiphilic microparticle with four discrete hydrophilic patches embedded at the inner corners of a square‐shaped hydrophobic outer ring of the particle (4C particle) is fabricated. Three dimensional computational fluid dynamics simulations predict droplet formation dynamics and differing equilibrium conditions depending on the patterning configuration. Experiments recapitulate equilibrium conditions, enabling tunable dropicle configurations with reproducible volumes down to ≈200 pL templated by the amphiphilic particles. The dropicle configurations depend predominantly on the size of the hydrophilic patches of the 4C particles. This validates that the modeling approach can inform the design of dropicles with varying volumes and numbers per particle, which can be harnessed in new amplified bioassays for greater sensitivity, dynamic range, and statistical confidence.


  • Open Access

    Acoustic Waves Coupling with Polydimethylsiloxane in Reconfigurable Acoustofluidic Platform

    by Jeongeun Park, Beomseok Cha, Furkan Ginaz Almus, Mehmet Akif Sahin, Hyochan Kang, Yeseul Kang, Ghulam Destgeer, Jinsoo Park

    Acoustofluidics is a promising technology that leverages acoustic waves for precise manipulation of micro/nano‐scale flows and suspended objects within microchannels. Despite many advantages, the practical applicability of conventional acoustofluidic platforms is limited by irreversible bonding between the piezoelectric actuator and the microfluidic chip. Recently, reconfigurable acoustofluidic platforms are enabled by reversible bonding between the reusable actuator and the replaceable polydimethylsiloxane (PDMS) microfluidic chip by incorporating a PDMS membrane for sealing the microchannel and coupling the acoustic waves with the fluid inside. However, a quantitative guideline for selecting a suitable PDMS membrane for various acoustofluidic applications is still missing. Here, a design rule for reconfigurable acoustofluidic platforms is explored based on a thorough investigation of the PDMS thickness effect on acoustofluidic phenomena: acousto–thermal heating (ATH), acoustic radiation force (ARF), and acoustic streaming flow (ASF). These findings suggest that the relative thickness of the PDMS membrane ( t ) for acoustic wavelength ( λ PDMS ) determines the wave attenuation in the PDMS and the acoustofluidic phenomena. For t / λ PDMS ≈ O(1), the transmission of acoustic waves through the membrane leads to the ARF and ASF phenomena, whereas, for t / λ PDMS ≈ O(10), the acoustic waves are entirely absorbed within the membrane, resulting in the ATH phenomenon.


  • Open Access

    Spatiotemporal control of a multilayered co-axial flow in a 3D printed microchannel with cascaded nozzles

    by Helen Werner, Ebrahim TaiediNejad, Mehmet Akif Sahin, Moritz Leuthner, Peer Erfle, Oliver Hayden, Andreas Dietzel, Ghulam Destgeer

    Sculpting and stopping multilayered co-flowing streams is challenging due to inhomogeneous pressure distribution within a fluidic circuit composed of multiple interconnected microchannels having variable flow resistances. Here, we have investigated three different flow control methods to effectively stop a multilayered flow inside a 3D-printed microfluidic channel by bringing the average flow velocity from >100 mm s -1 to below a critical velocity of 200 µm s -1 within a certain delay time t D of ∼2s. Firstly, we 3D printed a sequence of three concentric nozzles (∼75 µm) embedded serially inside the microchannel (∼200 µm) using a two-photon polymerization (2PP) method. Secondly, we used the 2PP-based 3D printed device to produce a structured coaxial flow of four streams with individual layer thicknesses of O (10 µm) within the outlet section of the microchannel. Thirdly, we removed the pressure gradient across the fluidic circuit, from > 2 bar to ∼0 bar, to stop the multilayered flow and measured t D to assess the performance of the three stop flow methods. During the stop-flow phase, an inhomogeneous pressure gradient across different inlets resulted in a backflow to inlet channels with lower pressures. In the three stop-flow methods investigated, we systemically managed the fluidic capacitance to minimize a dimensionless backflow index ( BFI ) value from ∼0.3 (worst case) to ∼0.03 (best case) for a total flow rate ranging from 16.8 µl min -1 to 168 µl min -1 . Finally, we have recommended the best stop-flow conditions, which resulted in a minimal delay time of t D ∼ 2s and a BFI < 0.05.