Christine Maged El-Maraghy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christine Maged El-Maraghy has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Heba T. Elbalkiny
1 shared publicationHesham Salem
Pharmaceutical Analytical Chemistry department, Faculty of Pharmacy, Deraya University, Minia, Egypt
1 shared publicationManal M. Fouad
Analytical Chemistry Department, Faculty of Pharmacy, October University for Modern Sciences and Arts (MSA), Egypt
1 shared publicationMarianne Nebsen
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr-El Aini Street, 11562 Cairo, Egypt
1 shared publicationMiriam F. Ayad
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt
1 shared publication- Miriam Farid Ayad
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 15 July 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-13
Implementation of green-assessed nanotechnology and quality by design approach for development of optical sensor for determination of tobramycin in ophthalmic formulations and spiked human plasma
A fast eco-friendly colorimetric method was developed for the determination of Tobramycin in drug substance, ophthalmic formulations, and spiked human plasma using silver nanoparticles optical sensor. Even though tobramycin is non-UV–visible absorbing, the developed method is based on measuring the absorbance quenching of silver nanoparticles resulting from the interaction with tobramycin. Different factors affecting the absorbance intensity were studied as; silver nanoparticle concentration, pH, buffer type, and reaction time using quality by design approach. Validation of the proposed method was performed according to ICH guidelines and was found to be accurate, precise, and sensitive. The linearity range of tobramycin was 0.35–4.0 μg/mL. The optical sensor was successfully applied for the determination of Tobramycin in ophthalmic formulations and spiked human plasma without pre-treatment. Additionally, the binding between Tobramycin and PVP- capped silver nanoparticles was studied using molecular docking software. The method was assessed and compared to colorimetric reported methods for the green character using Green Analytical Procedure Index (GAPI) and Analytical GREEnness calculator (AGREE) tools and found to be greener.
- 15 July 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-13
Open AccessImplementation of green-assessed nanotechnology and quality by design approach for development of optical sensor for determination of tobramycin in ophthalmic formulations and spiked human plasma
A fast eco-friendly colorimetric method was developed for the determination of Tobramycin in drug substance, ophthalmic formulations, and spiked human plasma using silver nanoparticles optical sensor. Even though tobramycin is non-UV–visible absorbing, the developed method is based on measuring the absorbance quenching of silver nanoparticles resulting from the interaction with tobramycin. Different factors affecting the absorbance intensity were studied as; silver nanoparticle concentration, pH, buffer type, and reaction time using quality by design approach. Validation of the proposed method was performed according to ICH guidelines and was found to be accurate, precise, and sensitive. The linearity range of tobramycin was 0.35–4.0 μg/mL. The optical sensor was successfully applied for the determination of Tobramycin in ophthalmic formulations and spiked human plasma without pre-treatment. Additionally, the binding between Tobramycin and PVP- capped silver nanoparticles was studied using molecular docking software. The method was assessed and compared to colorimetric reported methods for the green character using Green Analytical Procedure Index (GAPI) and Analytical GREEnness calculator (AGREE) tools and found to be greener.
- Open Access
- 17 August 2023
- Published by Springer Nature in BMC Chemistry
- Vol. 17 (1) , 1-11
Sustainable eco-friendly ratio-based spectrophotometric and HPTLC-densitometric methods for simultaneous analysis of co-formulated anti-migraine drugs with overlapped spectra
Considering the green chemistry perspective and improving the environmental impact of quality control labs; two direct techniques with less hazardous solvents, less waste production and less energy consumption were developed for simultaneous analysis of Aspirin and Metoclopramide in bulk powder and pharmaceutical formulation. The ratio between the two drugs in their co-formulated preparation is very challenging; (90: 1, Aspirin: Metoclopramide). The first technique is spectrophotometry using simple mathematical operations; ratio difference and derivative ratio–zero crossing. The second technique is high-performance thin-layer chromatography (HPTLC) -densitometry which used a mobile phase consisting of cyclo-hexane: methanol: methylene chloride in a ratio of (1:4:1, v/v/v). The greenest solvents which give acceptable resolution were chosen. Following the International Conference on Harmonization (ICH) guidelines, the methods were found to be accurate, precise, and selective. Those methods were statistically compared to the reported spectrophotometric method and the results proved that there is no significant difference in accuracy and precision. Furthermore, the developed methods were assessed using the Analytical Eco-scale, Green Analytical Procedure Index (GAPI) and the Analytical Greenness calculator (AGREE), which gave a full image about their greenness profile. The spectrophotometry was found to be an excellent green technique compared to HPTLC with was considered an acceptable green one. The developed HPTLC-densitometric method was used for the first time for the analysis of this binary mixture. The two proposed spectrophotometric methos have advantages over the published methods as they used easy manipulation steps and are applied on the market pharmaceutical formulation. Owing to the advantages of the developed techniques; being green, do not require expensive sophisticated equipment or large volume of solvents; they could be used for routine analysis in quality control aspects.
- 17 August 2023
- Published by Springer Nature in BMC Chemistry
- Vol. 17 (1) , 1-11
Open AccessSustainable eco-friendly ratio-based spectrophotometric and HPTLC-densitometric methods for simultaneous analysis of co-formulated anti-migraine drugs with overlapped spectra
Considering the green chemistry perspective and improving the environmental impact of quality control labs; two direct techniques with less hazardous solvents, less waste production and less energy consumption were developed for simultaneous analysis of Aspirin and Metoclopramide in bulk powder and pharmaceutical formulation. The ratio between the two drugs in their co-formulated preparation is very challenging; (90: 1, Aspirin: Metoclopramide). The first technique is spectrophotometry using simple mathematical operations; ratio difference and derivative ratio–zero crossing. The second technique is high-performance thin-layer chromatography (HPTLC) -densitometry which used a mobile phase consisting of cyclo-hexane: methanol: methylene chloride in a ratio of (1:4:1, v/v/v). The greenest solvents which give acceptable resolution were chosen. Following the International Conference on Harmonization (ICH) guidelines, the methods were found to be accurate, precise, and selective. Those methods were statistically compared to the reported spectrophotometric method and the results proved that there is no significant difference in accuracy and precision. Furthermore, the developed methods were assessed using the Analytical Eco-scale, Green Analytical Procedure Index (GAPI) and the Analytical Greenness calculator (AGREE), which gave a full image about their greenness profile. The spectrophotometry was found to be an excellent green technique compared to HPTLC with was considered an acceptable green one. The developed HPTLC-densitometric method was used for the first time for the analysis of this binary mixture. The two proposed spectrophotometric methos have advantages over the published methods as they used easy manipulation steps and are applied on the market pharmaceutical formulation. Owing to the advantages of the developed techniques; being green, do not require expensive sophisticated equipment or large volume of solvents; they could be used for routine analysis in quality control aspects.
- 6 May 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (23) , 2586-2595
A validated liquid chromatography-tandem mass spectrometric method for the determination of co-administered ranitidine and metronidazole in plasma of human volunteers
This work describes the development, optimization and validation of a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for the simultaneous analysis of co-administered ranitidine (RAN) and metronidazole (MET) in plasma of healthy human volunteers. A simple protein precipitation procedure using 1 mL acetonitrile was applied to extract both drugs and metoclopramide as an internal standard (IS) from plasma. The chromatographic separation was achieved on a C18 column with isocratic elution of the mobile phase consisting of acetonitrile and 0.1% formic acid (90 : 10, v/v) at a flow rate of 0.35 mL min−1. The positive ionization mode was used for detecting the ions, by observing the pairs of transition m/z 314.82 < 176.06 for RAN, m/z 172.03 < 127.95 for MET and m/z 299.86 < 277.10 for IS. The linearity range was from 5–600 ng mL−1 for RAN and 2–40 μg mL−1 for MET. The method was found to be sensitive and accurate with good simple extraction recovery and matrix effect, according to FDA guidelines for bioanalytical methods. The developed method could be applied for further bioavailability studies that could be useful in therapeutic drug monitoring.
- 6 May 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (23) , 2586-2595
A validated liquid chromatography-tandem mass spectrometric method for the determination of co-administered ranitidine and metronidazole in plasma of human volunteers
This work describes the development, optimization and validation of a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for the simultaneous analysis of co-administered ranitidine (RAN) and metronidazole (MET) in plasma of healthy human volunteers. A simple protein precipitation procedure using 1 mL acetonitrile was applied to extract both drugs and metoclopramide as an internal standard (IS) from plasma. The chromatographic separation was achieved on a C18 column with isocratic elution of the mobile phase consisting of acetonitrile and 0.1% formic acid (90 : 10, v/v) at a flow rate of 0.35 mL min−1. The positive ionization mode was used for detecting the ions, by observing the pairs of transition m/z 314.82 < 176.06 for RAN, m/z 172.03 < 127.95 for MET and m/z 299.86 < 277.10 for IS. The linearity range was from 5–600 ng mL−1 for RAN and 2–40 μg mL−1 for MET. The method was found to be sensitive and accurate with good simple extraction recovery and matrix effect, according to FDA guidelines for bioanalytical methods. The developed method could be applied for further bioavailability studies that could be useful in therapeutic drug monitoring.
- Open Access
- 7 March 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (3) , 52
Influence of Nitrogen-Doped Carbon Dot and Silver Nanoparticle Modified Carbon Paste Electrodes on the Potentiometric Determination of Tobramycin Sulfate: A Comparative Study
Two inexpensive and simple methods for synthesis of carbon nanodots were applied and compared to each other, namely a hydrothermal and microwave-assisted method. The synthesized carbon nanodots were characterized using transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis), photoluminescence (PL), Fourier transform-infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The synthesized microwave carbon nanodots had smaller particle size and were thus chosen for better electrochemical performance. Therefore, they were used for our modification process. The proposed electrodes performance characteristics were evaluated according to the IUPAC guidelines, showing linear response in the concentration range 10−6–10−2, 10−7–10−2, and 10−8–10−2 M of tobramycin with a Nernstian slope of 52.60, 58.34, and 57.32 mV/decade for the bare, silver nanoparticle and carbon nanodots modified carbon paste electrodes, respectively. This developed potentiometric method was used for quantification of tobramycin in its co-formulated dosage form and spiked human plasma with good recovery percentages and without interference of the co-formulated drug loteprednol etabonate and excipients.
- 7 March 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (3) , 52
Open AccessInfluence of Nitrogen-Doped Carbon Dot and Silver Nanoparticle Modified Carbon Paste Electrodes on the Potentiometric Determination of Tobramycin Sulfate: A Comparative Study
Two inexpensive and simple methods for synthesis of carbon nanodots were applied and compared to each other, namely a hydrothermal and microwave-assisted method. The synthesized carbon nanodots were characterized using transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis), photoluminescence (PL), Fourier transform-infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The synthesized microwave carbon nanodots had smaller particle size and were thus chosen for better electrochemical performance. Therefore, they were used for our modification process. The proposed electrodes performance characteristics were evaluated according to the IUPAC guidelines, showing linear response in the concentration range 10−6–10−2, 10−7–10−2, and 10−8–10−2 M of tobramycin with a Nernstian slope of 52.60, 58.34, and 57.32 mV/decade for the bare, silver nanoparticle and carbon nanodots modified carbon paste electrodes, respectively. This developed potentiometric method was used for quantification of tobramycin in its co-formulated dosage form and spiked human plasma with good recovery percentages and without interference of the co-formulated drug loteprednol etabonate and excipients.
- Open Access
- 6 August 2019
- Published by Springer Nature in BMC Chemistry
- Vol. 13 (1) , 1-8
Three smart spectrophotometric methods for resolution of severely overlapped binary mixture of Ibuprofen and Paracetamol in pharmaceutical dosage form
Paracetamol is an analgesic-antipyretic drug and Ibuprofen is a non-steroidal anti-inflammatory drug. They are co-formulated as tablets to improve analgesia, to simplify prescribing and to improve patient compliance. Three accurate, simple and sensitive spectrophotometric methods were developed for the simultaneous determination of Paracetamol and Ibuprofen in their co-formulated dosage form. The first method was the ratio difference, which was based on the measurement of the difference in absorbance between the two wavelengths (210.6 and 216.4 nm) for Ibuprofen and (236.0 and 248.0 nm) for Paracetamol. The second method was constant center method which depends on using the constant found in the ratio spectra. The third method was the mean centering of ratio spectra which measured the manipulated values at 240 nm and 237 nm for Ibuprofen and Paracetamol, respectively. Beer’s law was obeyed in the concentration range of 2–50 μg/mL for Ibuprofen and 2–20 μg/mL for Paracetamol. The recovery % of the accuracy of both methods ranged from 99.64 to 100.56%. Factors affecting the resolution of the spectra were studied and optimized. The three methods are validated according to ICH guidelines and could be applied for the pharmaceutical preparation.
- 6 August 2019
- Published by Springer Nature in BMC Chemistry
- Vol. 13 (1) , 1-8
Open AccessThree smart spectrophotometric methods for resolution of severely overlapped binary mixture of Ibuprofen and Paracetamol in pharmaceutical dosage form
Paracetamol is an analgesic-antipyretic drug and Ibuprofen is a non-steroidal anti-inflammatory drug. They are co-formulated as tablets to improve analgesia, to simplify prescribing and to improve patient compliance. Three accurate, simple and sensitive spectrophotometric methods were developed for the simultaneous determination of Paracetamol and Ibuprofen in their co-formulated dosage form. The first method was the ratio difference, which was based on the measurement of the difference in absorbance between the two wavelengths (210.6 and 216.4 nm) for Ibuprofen and (236.0 and 248.0 nm) for Paracetamol. The second method was constant center method which depends on using the constant found in the ratio spectra. The third method was the mean centering of ratio spectra which measured the manipulated values at 240 nm and 237 nm for Ibuprofen and Paracetamol, respectively. Beer’s law was obeyed in the concentration range of 2–50 μg/mL for Ibuprofen and 2–20 μg/mL for Paracetamol. The recovery % of the accuracy of both methods ranged from 99.64 to 100.56%. Factors affecting the resolution of the spectra were studied and optimized. The three methods are validated according to ICH guidelines and could be applied for the pharmaceutical preparation.
- 1 April 2019
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 32 (2) , 127-131
Rapid validated thin-layer chromatography–densitometry for the simultaneous determination of three co-formulated drugs used for common cold treatment
A rapid validated thin-layer chromatography (TLC)‒densitometric method has been developed for the simultaneous determination of 3 co-formulated drugs used for common cold and cough treatment. The studied drugs are paracetamol, pseudoephedrine, and chlorpheniramine maleate. The separation was achieved using silica gel 60 F254 plates and the developing system of methanol‒ toluene‒acetic acid (44:16:1, v/v). Densitometry scanning was performed at 254 nm. The method was validated as per the International Conference on Harmonization (ICH) guidelines and was successfully applied for the analysis of pharmaceutical preparation containing the cited ternary mixture without interference from excipients. There is no previously published TLC–densitometric method for the determination of the previously mentioned ternary mixture. The suggested method is rapid and of low cost, so it can be used for quality control analysis.
- 1 April 2019
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 32 (2) , 127-131
Rapid validated thin-layer chromatography–densitometry for the simultaneous determination of three co-formulated drugs used for common cold treatment
A rapid validated thin-layer chromatography (TLC)‒densitometric method has been developed for the simultaneous determination of 3 co-formulated drugs used for common cold and cough treatment. The studied drugs are paracetamol, pseudoephedrine, and chlorpheniramine maleate. The separation was achieved using silica gel 60 F254 plates and the developing system of methanol‒ toluene‒acetic acid (44:16:1, v/v). Densitometry scanning was performed at 254 nm. The method was validated as per the International Conference on Harmonization (ICH) guidelines and was successfully applied for the analysis of pharmaceutical preparation containing the cited ternary mixture without interference from excipients. There is no previously published TLC–densitometric method for the determination of the previously mentioned ternary mixture. The suggested method is rapid and of low cost, so it can be used for quality control analysis.
- 4 March 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (2) , 258-272
Stability Indicating Spectrophotometric and Chemometric Methods for Determination of Aripiprazole in Presence of its Degradation Products, A Comparative Study
Simple, accurate, selective and validated stability indicating UV spectrophotometric univariate and multivariate methods were developed for determination of Aripiprazole in presence of its alkaline and oxidative degradation products. The developed univariate methods; derivative ratio spectra-zero crossing, successive derivatives of ratio spectra and mean centering of ratio spectra. The first one used the amplitude of the first derivative ratio signals at 303.0 nm, the second method depended on the successive derivative of ratio spectra in two steps and measuring the absorbance of Aripiprazole at 281.0 nm and the third one measured the mean centered values oat 294.0 nm. Two chemometric multivariate methods were applied; principal component regression (PCR) and partial least-squares regression (PLS). The selectivity of the proposed methods was confirmed using laboratory-prepared mixtures. The obtained results were statistically compared with those obtained with the manufacturer HPLC method, showing no significant difference with in accuracy and precision. These methods could be applied as stability indicating methods for the determination of Aripiprazole in presence of its degradation products, in bulk powder or in pharmaceutical formulations.
- 4 March 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (2) , 258-272
Stability Indicating Spectrophotometric and Chemometric Methods for Determination of Aripiprazole in Presence of its Degradation Products, A Comparative Study
Simple, accurate, selective and validated stability indicating UV spectrophotometric univariate and multivariate methods were developed for determination of Aripiprazole in presence of its alkaline and oxidative degradation products. The developed univariate methods; derivative ratio spectra-zero crossing, successive derivatives of ratio spectra and mean centering of ratio spectra. The first one used the amplitude of the first derivative ratio signals at 303.0 nm, the second method depended on the successive derivative of ratio spectra in two steps and measuring the absorbance of Aripiprazole at 281.0 nm and the third one measured the mean centered values oat 294.0 nm. Two chemometric multivariate methods were applied; principal component regression (PCR) and partial least-squares regression (PLS). The selectivity of the proposed methods was confirmed using laboratory-prepared mixtures. The obtained results were statistically compared with those obtained with the manufacturer HPLC method, showing no significant difference with in accuracy and precision. These methods could be applied as stability indicating methods for the determination of Aripiprazole in presence of its degradation products, in bulk powder or in pharmaceutical formulations.