Baoming Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Baoming Gong has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Baoming Gong
Department of Materials Science and Engineering, Tianjin University, Tianjin, China
1 shared publication Caiyan Deng
Tianjin University School of Materials Science and Engineering
1 shared publication- Caiyan Deng1 shared publication
- Dongpo Wang
Key Laboratory of Advanced Joining Technology of Tianjin, Department of Materials Science and Engineering, Tianjin University, Road Weijin 92, Tianjin 300072, China
1 shared publication - Hang Liang
School of Materials Science and Engineering, Tianjin University, Tianjin 300350, China
1 shared publication Niantao Zhang
Tianjin University School of Materials Science and Engineering
1 shared publication
Latest Publications
- Open Access
- 16 April 2024
- Published by Wiley
Fatigue testing strategies for the X65 steel catenary riser with small-scale specimens considering the effect of welding residual stress
Wave-induced fatigue damage is inevitable for the deepwater steel catenary riser (SCR). To accurately evaluate the fatigue performance of the full-scale SCR using small-size specimens, five kinds of fatigue testing strategies were explored, considering the effect of welding residual stress. Further, the corresponding fatigue tests were conducted regarding the welded joint specimens with the same weld profile, and the relevant differences in fatigue testing results were comprehensively analyzed. Through comparison with the full-scale resonant bending fatigue testing results, the most equivalent strategy using small-scale specimens was confirmed. The relevant results indicated that compared with the fatigue lives of full-scale pipeline joint specimens, the fatigue testing lives under the constant applied maximum stress of the yield strength for base material or the constant applied mean stress of the peak value of transverse welding residual stress strategy are relatively lower. The fatigue life values obtained from the high-stress ratio testing strategy are higher, especially in the low-stress range region. Comparatively, the fatigue lives obtained under the 80 mm wide specimen without the cutting process strategy were higher in the high-stress range region. The variable applied mean stress strategy using the 25 mm wide welded joint specimen was most suitable for equivalence with full-scale fatigue testing results, and the difference in the fatigue life testing results was only 9.7%. The difference between the applied mean stress and the actual transverse welding residual stress under various fatigue testing strategies is the key to affecting the equivalence of fatigue testing results.
- 16 April 2024
- Published by Wiley
Open AccessFatigue testing strategies for the X65 steel catenary riser with small-scale specimens considering the effect of welding residual stress
Wave-induced fatigue damage is inevitable for the deepwater steel catenary riser (SCR). To accurately evaluate the fatigue performance of the full-scale SCR using small-size specimens, five kinds of fatigue testing strategies were explored, considering the effect of welding residual stress. Further, the corresponding fatigue tests were conducted regarding the welded joint specimens with the same weld profile, and the relevant differences in fatigue testing results were comprehensively analyzed. Through comparison with the full-scale resonant bending fatigue testing results, the most equivalent strategy using small-scale specimens was confirmed. The relevant results indicated that compared with the fatigue lives of full-scale pipeline joint specimens, the fatigue testing lives under the constant applied maximum stress of the yield strength for base material or the constant applied mean stress of the peak value of transverse welding residual stress strategy are relatively lower. The fatigue life values obtained from the high-stress ratio testing strategy are higher, especially in the low-stress range region. Comparatively, the fatigue lives obtained under the 80 mm wide specimen without the cutting process strategy were higher in the high-stress range region. The variable applied mean stress strategy using the 25 mm wide welded joint specimen was most suitable for equivalence with full-scale fatigue testing results, and the difference in the fatigue life testing results was only 9.7%. The difference between the applied mean stress and the actual transverse welding residual stress under various fatigue testing strategies is the key to affecting the equivalence of fatigue testing results.
- 1 August 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (32) , 15575-15585
Specimen thickness effect on the property of hydrogen embrittlement in single edge notch tension testing of high strength pipeline steel
- 1 August 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (32) , 15575-15585
Specimen thickness effect on the property of hydrogen embrittlement in single edge notch tension testing of high strength pipeline steel