YLYuanzhe Li

Yuanzhe Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuanzhe Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Organic electrochemical transceiver: An all-in-one sense-and-release device architecture for physiological modulation

    by Yuanzhe Li, Mengying Yan, Xie He, Cunman Liang, Heng Liu, Qian Zhu, Mingqiang Wang, Xinhui Lu, Yi Lu, Ni Zhao

    Intelligent wearable devices with integrated sensing and drug-releasing functions are essential for delivering real-time and personalized interventions. Current approaches typically rely on interconnected modules, facing challenges such as large footprint, high energy consumption, and fabrication complexity. To address these limitations, we introduce a modified organic electrochemical transistor structure called the organic electrochemical transceiver (OECTC). The OECTC leverages the electronic wettability switch characteristic of conjugated polymers to convert sensed signals into a valve mechanism for controlling the release of chemical substances (e.g., drugs and neurotransmitters). This provides an all-in-one solution for synchronized signal recording and substance release for physiological modulation. The applications of the OECTC in intelligent wearable devices for managing type II diabetes and as a neural amplifier or inverter for neurotransmitter modulation are demonstrated.


  • Top Cited Papers

    A microsized optical spectrometer based on an organic photodetector with an electrically tunable spectral response

    by Xie He, Yuanzhe Li, Hui Yu, Guodong Zhou, Lingyi Ke, Hin-Lap Yip, Ni Zhao


  • Open Access

    Addressing gain-bandwidth trade-off by a monolithically integrated photovoltaic transistor

    by Yuanzhe Li, Guowei Chen, Shenghe Zhao, Chuan Liu, Ni Zhao

    The gain-bandwidth trade-off limits the development of high-performance photodetectors; i.e., the mutual restraint between the response speed and gain has intrinsically limited performance optimization of photomultiplication phototransistors and photodiodes. Here, we show that a monolithically integrated photovoltaic transistor can solve this dilemma. In this structure, the photovoltage generated by the superimposed perovskite solar cell, acting as a float gate, is amplified by the underlying metal oxide field-effect transistor. By eliminating deep-trap defects through processing optimization, we achieved devices with a maximum responsivity close to 6 × 10 4 A/W, a specific detectivity ( D *) of 1.06 × 10 13 Jones, and an f 3dB of 1.2 MHz at a low driving voltage of 3 V. As a result, a record gain-bandwidth product is achieved. The device further exhibits the advantage in photoplethysmography detection with weak illuminations, where our device accurately detects the detailed features that are out of the capability of conventional photodetectors.


  • Biomimicking Stretchable Organic Electrochemical Transistor

    by Yuanzhe Li, Naixiang Wang, Anneng Yang, Haifeng Ling, Feng Yan

    Stretchable organic electrochemical transistors (OECTs) can find applications in wearable electronics for biosensing. However, the existing fabrication methods are either inconvenient or expensive. Here, a novel method to fabricate stretchable OECTs based on biomimicking polydimethylsiloxane substrates is reported. The substrate pattern is transferred from the bract of Bougainvillea glabra, demonstrating a 2D wavy structure. To further enhance the stretchability of the Au electrodes of the devices on the wavy surface, a highly conductive polymer film is coated on the Au surface by inkjet printing to bridge disconnected parts separated by cracks. The obtained OECTs demonstrate omnidirectional stretchability up to 30% and a bending radius down to 15 mm with stable performance. Stretchable glucose sensors with a detection limit around 1 µm are developed based on the biomimicking stretchable OECTs, which are sensitive enough for detecting glucose levels in body fluids.