Andrew D. Morse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrew D. Morse has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Barbara Anne Cohen
NASA Goddard Space Flight Center Greenbelt MD USA
2 shared publications Christopher Howe
STFC RAL Space, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire, OX11 0QX, UK
2 shared publications- David Heather
European Space Agency – ESTEC, Noordwijk, The Netherlands
2 shared publications Natalie M. Curran
Center for Research and Exploration in Space Science and Technology, NASA/GSFC, Greenbelt, MD 20771, USA
2 shared publicationsPhillip A. Driggers
NASA Goddard Space Flight Center, 8800 Greenbelt Road, Greenbelt, MD 20771, USA
2 shared publications- Roland Trautner
European Space Agency, P. O. Box 299, Noordwijk, South Holland, 2200AG, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 6 (1) , 14
The Peregrine Ion Trap Mass Spectrometer (PITMS): Results from a CLPS-delivered Mass Spectrometer
The Peregrine Ion Trap Mass Spectrometer (PITMS) was a mass spectrometer designed to measure lunar gases. PITMS flew on the first flight of Astrobotic’s Peregrine lander via the Commercial Lunar Payload Services (CLPS) program in 2024 January. After launch, the lander suffered a propulsion system anomaly that prevented the mission from reaching the Moon, but PITMS collected 80 high-quality spectra while in cislunar space. PITMS observed abundant outgassing products from the Peregrine lander, including water, MON-25 oxidizer from the propulsion system leak, and traces of combustion products. PITMS data help constrain the nature of the propulsion system failure: oxidizer molecular ratios show that the leak released molecules rapidly enough for them to fully dissociate, and the high observed abundances imply that the oxidizer traveled within the lander surfaces rather than jetting into space. The amount of water offgassed by the spacecraft is substantially more than other planetary spacecraft, so the PITMS results suggest that instruments flying in the CLPS paradigm need to consider lander cleanliness. Though not successful in measuring the native lunar exosphere, the PITMS results showcase the capabilities of a mass spectrometer on board a lunar lander, along with lessons in pragmatism and flexibility that would enable such an instrument to ultimately be successful in the CLPS initiative.
- 1 January 2025
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 6 (1) , 14
Open AccessThe Peregrine Ion Trap Mass Spectrometer (PITMS): Results from a CLPS-delivered Mass Spectrometer
The Peregrine Ion Trap Mass Spectrometer (PITMS) was a mass spectrometer designed to measure lunar gases. PITMS flew on the first flight of Astrobotic’s Peregrine lander via the Commercial Lunar Payload Services (CLPS) program in 2024 January. After launch, the lander suffered a propulsion system anomaly that prevented the mission from reaching the Moon, but PITMS collected 80 high-quality spectra while in cislunar space. PITMS observed abundant outgassing products from the Peregrine lander, including water, MON-25 oxidizer from the propulsion system leak, and traces of combustion products. PITMS data help constrain the nature of the propulsion system failure: oxidizer molecular ratios show that the leak released molecules rapidly enough for them to fully dissociate, and the high observed abundances imply that the oxidizer traveled within the lander surfaces rather than jetting into space. The amount of water offgassed by the spacecraft is substantially more than other planetary spacecraft, so the PITMS results suggest that instruments flying in the CLPS paradigm need to consider lander cleanliness. Though not successful in measuring the native lunar exosphere, the PITMS results showcase the capabilities of a mass spectrometer on board a lunar lander, along with lessons in pragmatism and flexibility that would enable such an instrument to ultimately be successful in the CLPS initiative.
- Open Access
- 1 September 2024
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 5 (9) , 212
The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Preflight Planning
The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team, consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University, NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of a European Space Agency–provided Exospheric Mass Spectrometer (including sensor, electronics, controller, and power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in an RF field, and then sequentially be released to a detector to build a mass spectrum. PITMS was capable of measuring species with a mass-to-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.
- 1 September 2024
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 5 (9) , 212
Open AccessThe Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Preflight Planning
The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team, consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University, NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of a European Space Agency–provided Exospheric Mass Spectrometer (including sensor, electronics, controller, and power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in an RF field, and then sequentially be released to a detector to build a mass spectrum. PITMS was capable of measuring species with a mass-to-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.
- 26 July 2019
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 3 (9) , 1773-1791
Observations of Cometary Organics: A Post Rosetta Review
- 26 July 2019
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 3 (9) , 1773-1791
Observations of Cometary Organics: A Post Rosetta Review
- 1 August 2016
- Published by Elsevier in Acta Astronautica
- Vol. 125, 196-211
Ptolemy operations at the surface of a comet, from planning to reality
- 1 August 2016
- Published by Elsevier in Acta Astronautica
- Vol. 125, 196-211
Ptolemy operations at the surface of a comet, from planning to reality
- Open Access
- 30 October 2015
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 583, A42
Low CO/CO2ratios of comet 67P measured at the Abydos landing site by thePtolemymass spectrometer
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 30 October 2015
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 583, A42
Open AccessLow CO/CO2ratios of comet 67P measured at the Abydos landing site by thePtolemymass spectrometer
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 16 May 2015
- Published by Springer Nature in Space Science Reviews
- Vol. 197 (1-4) , 47-83
Cometary Isotopic Measurements
- 16 May 2015
- Published by Springer Nature in Space Science Reviews
- Vol. 197 (1-4) , 47-83
Cometary Isotopic Measurements