Chao Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chao Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Bei Wang
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine Sir Run Run Shaw Hospital
3 shared publications- Bowen Zhao
Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital Zhejiang University College of Medicine Hangzhou China
3 shared publications Mei Pan
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine, Sir Run Run Shaw Hospital, Hangzhou, China
2 shared publicationsRan Chen
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine, Sir Run Run Shaw Hospital, Hangzhou, China
2 shared publicationsXiaohui Peng
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine Sir Run Run Shaw Hospital
2 shared publicationsYankai Mao
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine Sir Run Run Shaw Hospital
2 shared publications
Latest Publications
- 11 March 2021
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 35 (25) , 5872-5880
Preliminary study on the evaluation of mitral annulus displacement in normal fetuses by automated cardiac motion quantitation
The aim of this study was to assess the characteristics of mitral annular plane systolic excursion (MAPSE) in different longitudinal directions in normal fetuses using a new method, automatic cardi...
- 11 March 2021
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 35 (25) , 5872-5880
Preliminary study on the evaluation of mitral annulus displacement in normal fetuses by automated cardiac motion quantitation
The aim of this study was to assess the characteristics of mitral annular plane systolic excursion (MAPSE) in different longitudinal directions in normal fetuses using a new method, automatic cardi...
- 1 November 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (4) , 775-784
Is Fetal Intelligent Navigation Echocardiography Helpful in Screening for d‐Transposition of the Great Arteries?
Objectives: To evaluate the performance of fetal intelligent navigation echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volumes in generating 3 specific abnormal cardiac views (left ventricular outflow tract, right ventricular outflow tract, and 3‐vessel and trachea) used to screen for d‐transposition of the great arteries (d‐TGA).Methods: In this prospective study, 1 or more STIC volumes were obtained from the 4‐chamber view in 34 second‐ and third‐trimester fetuses with d‐TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d‐TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient.Results: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d‐TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3‐vessel and trachea view. Twenty‐four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers.Conclusions: In cases of d‐TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.
- 1 November 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (4) , 775-784
Is Fetal Intelligent Navigation Echocardiography Helpful in Screening for d‐Transposition of the Great Arteries?
Objectives: To evaluate the performance of fetal intelligent navigation echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volumes in generating 3 specific abnormal cardiac views (left ventricular outflow tract, right ventricular outflow tract, and 3‐vessel and trachea) used to screen for d‐transposition of the great arteries (d‐TGA).Methods: In this prospective study, 1 or more STIC volumes were obtained from the 4‐chamber view in 34 second‐ and third‐trimester fetuses with d‐TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d‐TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient.Results: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d‐TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3‐vessel and trachea view. Twenty‐four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers.Conclusions: In cases of d‐TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.
- 11 August 2019
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 34 (12) , 1932-1940
Smart-planes fetal heart (S-planes FH) software to quantitative evaluate the fetal great arteries
To explore the feasibility of applying smart-planes fetal heart (S-Planes FH) to 3D volumes to generate and display the outflow tract views (OFTVs) and evaluate its agreement and reliability in det...
- 11 August 2019
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 34 (12) , 1932-1940
Smart-planes fetal heart (S-planes FH) software to quantitative evaluate the fetal great arteries
To explore the feasibility of applying smart-planes fetal heart (S-Planes FH) to 3D volumes to generate and display the outflow tract views (OFTVs) and evaluate its agreement and reliability in det...
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21615942,p. 1-5
Inconsistency Management of Role Base Access Control Policy
Access control becomes more and more essential for safe and security access to the system resources. Role based access control policy widely used in industry enterprise systems nowadays is a statement which specifies the rules about how to setup the process for granting or denying authorizations. It is extremely important to make sure that there is no inconsistency of an access control policy, since otherwise it may conceal the security danger or even break down the entire access control system. In this paper, we analyze the inconsistencies of role based access control policy, and give the formal definition for the inconsistency. We then propose an inconsistency checking algorithm to detect the inconsistencies of a role based access control policy.
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21615942,p. 1-5
Inconsistency Management of Role Base Access Control Policy
Access control becomes more and more essential for safe and security access to the system resources. Role based access control policy widely used in industry enterprise systems nowadays is a statement which specifies the rules about how to setup the process for granting or denying authorizations. It is extremely important to make sure that there is no inconsistency of an access control policy, since otherwise it may conceal the security danger or even break down the entire access control system. In this paper, we analyze the inconsistencies of role based access control policy, and give the formal definition for the inconsistency. We then propose an inconsistency checking algorithm to detect the inconsistencies of a role based access control policy.