  • Wall Shear Imaging with Synthetic Aperture Universal Sequence: Preliminary In Vivo Precision Assessment in the Carotid Artery

    by Billy Y. S. Yiu, Alexander Cuculiza Henriksen, Julia Camara Aracil, Lars Emil Haslund, Adrian J. Y. Chee, Alfred C. H. Yu, Anders Bjorholm Dahl, Michael Bachmann Nielsen, Jørgen Arendt Jensen

    Wall shear stress (WSS) plays a crucial role in the initiation and progression of atherosclerosis. However, its noninvasive quantification remains challenging due to the limited spatiotemporal resolution and scalability of magnetic resonance imaging (MRI), as well as the limited precision (±30% error range) and image quality tradeoff of existing ultrasound-based approaches. This study presents an ultrasound-based wall shear imaging (WASHI) framework that simultaneously provides high-quality B-mode images and spatiotemporally resolved WSS maps, and evaluates its accuracy and precision. WASHI derives WSS directly from velocity gradients obtained using transverse oscillation vector flow imaging based on an interleaved synthetic aperture imaging sequence implemented on a Verasonics Vantage 256. Accuracy was assessed using a flow-rig setup under controlled conditions, and in vivo precision was evaluated in ten healthy volunteers through bilateral scans of the common carotid arteries (19 common carotid arteries (CCAs) in total). In the flow-rig experiments, WASHI produced consistent WSS estimates across 0° and 20° tilting angles with accuracy comparable to a velocity-based estimator (bias: -1 versus -3 mPa). In in vivo measurements, WASHI successfully tracked vessel wall motion over multiple cardiac cycles and resolved both spatial and temporal variations in WSS along both vessel walls. The median coefficient of variation (CV) across the 19 CCAs was 10.2%, demonstrating high measurement precision. Although this precision was slightly lower than that of the velocity-based estimator (CV: 6.2%), WASHI produced WSS magnitudes (2.7 and 2.3 Pa) that closely reflected the captured flow profile (2.9 and 2.4 Pa). In addition, the intrasubject variability of time-averaged WSS was the same across participants ( $p=0.45$ ), indicating reproducible performance. These results demonstrate the feasibility of WASHI for precise and reproducible WSS imaging, enabling future longitudinal studies and large-cohort investigations of vascular hemodynamics.

  • Open Access

    Bedside Ultrasound Vector Doppler Imaging System With GPU Processing and Deep Learning

    by Hassan Nahas, Billy Y. S. Yiu, Adrian J. Y. Chee, Takuro Ishii, Alfred C. H. Yu

    Recent innovations in vector flow imaging promise to bring the modality closer to clinical application and allow for more comprehensive high-frame-rate vascular assessments. One such innovation is plane-wave multi-angle vector Doppler, where pulsed Doppler principles from multiple steering angles are used to realize vector flow imaging at frame rates upward of 1,000 frames per second (fps). Currently, vector Doppler is limited by the presence of aliasing artifacts that have prevented its reliable realization at the bedside. In this work, we present a new aliasing-resistant vector Doppler imaging system that can be deployed at the bedside using a programmable ultrasound core, graphics processing unit (GPU) processing, and deep learning principles. The framework supports two operational modes: 1) live imaging at 17 fps where vector flow imaging serves to guide image view navigation in blood vessels with complex dynamics; 2) on-demand replay mode where flow data acquired at high frame rates of over 1,000 fps is depicted as a slow-motion playback at 60 fps using an aliasing-resistant vector projectile visualization. Using our new system, aliasing-free vector flow cineloops were successfully obtained in a stenosis phantom experiment and in human bifurcation imaging scans. This system represents a major engineering advance towards the clinical adoption of vector flow imaging.


  • Open Access

    Dual-modality flow phantom for ultrasound and optical flow measurements

    by Chris M Kallweit, Adrian J Y Chee, Billy Y S Yiu, Sean D Peterson, Alfred C H Yu

    As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom’s tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution’s optical transparency after thermocycling. The hydrogel’s optical attenuation {1.56 dB cm−1 with 95% confidence interval (CI) of [1.512 1.608]}, refractive index {1.337, CI: [1.340 1.333]}, acoustic attenuation {0.038 dB/(cm × MHz b ), CI: [0.0368 0.0403]; frequency dependent factor of 1.321, CI: [1.296 1.346]}, and speed of sound {1523.6 m s−1, CI: [1523.8 1523.4]} were found to be suitable for PIV and ultrasound flow measurements. As an application demonstration, a bimodal flow phantom with spiral lumen was fabricated and used in simultaneous flow measurements with PIV and ultrasound color flow imaging (CFI). Velocity fields and profiles were compared between the two modalities under a constant flow rate (2.5 ml s−1). CFI was found to overestimate flow speed compared to the PIV measurements, with a 14%, 10%, and 6% difference between PIV and ultrasound for the 60°, 45°, and 30° angles measured. These results demonstrate the new phantom’s feasibility in enabling performance validation of ultrasound flow mapping tools.


  • Open Access

    A Forked Microvascular Phantom for Ultrasound Localization Microscopy Investigations

    by Hanyue Shangguan, Billy Y. S. Yiu, Adrian J. Y. Chee, Alfred C. H. Yu

    In the development of ultrasound localization microscopy (ULM) methods, appropriate test beds are needed to facilitate algorithmic performance calibration. Here, we present the design of a new ULM-compatible microvascular phantom with a forked, V-shaped wall-less flow channel pair (250 μm channel width) that bifurcated at a separation rate of 50 μm/mm. The lumen core was fabricated using additive manufacturing, and it was molded within a polyvinyl alcohol (PVA) tissue mimicking slab using the lost-core casting method. Measured using optical microscopy, the lumen core’s flow channel width was found to be 252±15 μm with a regression-derived flow channel separation gradient of 50.89 μm/mm. The new phantom’s applicability in ULM performance analysis was demonstrated by feeding microbubble contrast flow (1.67 to 167 μl/s flow rates) through the phantom’s inlet and generating ULM images with a previously reported method. Results showed that, with longer acquisition times (10 s or longer), ULM image quality was expectedly improved, and the variance of ULM-derived flow channel measurements was reduced. Also, at axial depths near the lumen’s bifurcation point, the current ULM algorithm showed difficulty in properly discerning between the two flow channels because of the narrow channel-to-channel separation distance. Overall, the new phantom serves well as a calibration tool to test the performance of ULM methods in resolving small vasculature.


  • Open Access

    Branched Convolutional Neural Networks for Receiver Channel Recovery in High-Frame-Rate Sparse-Array Ultrasound Imaging

    by William M. K. Pitman, Di Xiao, Billy Y. S. Yiu, Adrian J. Y. Chee, Alfred C. H. Yu

    For high-frame-rate ultrasound imaging, it remains challenging to implement on compact systems as a sparse imaging configuration with limited array channels. One key issue is that the resulting image quality is known to be mediocre not only because unfocused plane-wave excitations are used, but also because grating lobes would emerge in sparse array configurations. In this paper, we present the design and use of a new channel recovery framework to infer full-array plane-wave channel datasets for periodically sparse arrays that operate with as few as one-quarter of the full-array aperture. This framework is based on a branched encoder-decoder convolutional neural network (CNN) architecture, which was trained using full-array plane-wave channel data collected from human carotid arteries (59,864 training acquisitions; 5 MHz imaging frequency; 20 MHz sampling rate; plane-wave steering angles between -15° and 15° in 1° increments). Three branched encoder-decoder CNNs were separately trained to recover missing channels after differing degrees of channel-wise downsampling (2, 3, and 4-times). The framework’s performance was tested on full-array and downsampled plane-wave channel data acquired from an in vitro point target, human carotid arteries, and human brachioradialis muscle. Results show that, when inferred full-array plane-wave channel data was used for beamforming, spatial aliasing artifacts in the B-mode images were suppressed for all degrees of channel downsampling. Also, the image contrast was enhanced comparing to B-mode images obtained from beamforming with downsampled channel data. When the recovery framework was implemented on an RTX-2080 GPU, the three investigated degrees of downsampling all achieved the same inference time of 4 ms. Overall, the proposed framework shows promise in enhancing the quality of high-frame-rate ultrasound images generated using a sparse-array imaging setup.


  • Open Access

    Time-Resolved Wall Shear Rate Mapping Using High-Frame-Rate Ultrasound Imaging

    by Adrian J. Y. Chee, Chung Kit Ho, Billy Y. S. Yiu, Alfred C. H. Yu

    In atherosclerosis, low wall shear stress (WSS) is known to favor plaque development while high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is crucial. Here we propose wall shear imaging (WASHI), a non-invasive contrast-free framework that leverages high-frame-rate ultrasound to map wall shear rate (WSR) that relates to WSS by the blood viscosity coefficient. Our method measures WSR as the tangential flow velocity gradient along the arterial wall from flow vector field derived using multi-angle vector Doppler technique. To improve WSR estimation performance, WASHI semi-automatically tracks the wall position throughout the cardiac cycle. WASHI was first evaluated with an in vitro linear WSR gradient model; the estimated WSR was consistent with theoretical values (average error of 4.6 ± 12.4%). The framework was then tested on healthy and diseased carotid bifurcation models. In both scenarios, key spatiotemporal dynamics of WSR were noted: (i) Oscillating shear patterns were present in the carotid bulb and downstream to the ICA where retrograde flow occurs; (ii) High WSR was observed particularly in the diseased model where measured WSR peaked at 810 s -1 due to flow jet. We also showed that WASHI could consistently track arterial wall motion to map its WSR. Overall, WASHI enables high temporal resolution mapping of WSR that could facilitate investigations on causal effects between WSS and atherosclerosis.


  • Auto SVD Clutter Filtering for US Doppler Imaging Using 3D Clustering Algorithm

    by Saad Ahmed Waraich, Adrian Chee, Di Xiao, Billy Y. S. Yiu, Alfred Yu