    Design of a Multi-Angle Multi-Depth Flow Phantom for Ultrasound Flow Calibration

    by Piero Tortoli, Francesco Lagonigro, Alessandro Ramalli, Giulio Bonciani, Billy Y. S. Yiu, Alfred C. H. Yu

    Ultrasound flow phantoms are essential tools for the development of new flow imaging algorithms and for performing quality assurance in medical imaging. A comprehensive system calibration, from shallow to deep flow regions, is increasingly needed to test novel velocity imaging methods. This study describes the design, implementation, and testing of a novel multi-angle, multi-depth flow phantom. Such key features are achieved by offsetting the two flow channels from the surface and incorporating acoustic wedges into the design. Our experiments show that the phantom was effective in evaluating the accuracy of Doppler velocity measurements attainable by sonicating vessels located at different depths with a commercial linear array probe whose acoustic lens was focused on elevation at 20 mm. An experimental multigate spectral Doppler analysis highlights the following behavior: 1) although the F-number was kept constant, spectral broadening increased with depth; 2) mean velocity was increasingly underestimated at greater depths. Both effects were significantly reduced by repeating the experiments with a custom-modified version of the same probe, not including any elevation lens, i.e., characterized by an approximately constant elevation beamwidth over the depth range of interest. Using the novel multi-depth flow phantom, it was thus possible to demonstrate experimentally that spatial velocity gradients determine performance drops that are not compensated by dynamic focusing, and appropriate arrays must be used when large depth ranges have to be investigated.

  • Wall Shear Imaging with Synthetic Aperture Universal Sequence: Preliminary In Vivo Precision Assessment in the Carotid Artery

    by Billy Y. S. Yiu, Alexander Cuculiza Henriksen, Julia Camara Aracil, Lars Emil Haslund, Adrian J. Y. Chee, Alfred C. H. Yu, Anders Bjorholm Dahl, Michael Bachmann Nielsen, Jørgen Arendt Jensen

    Wall shear stress (WSS) plays a crucial role in the initiation and progression of atherosclerosis. However, its noninvasive quantification remains challenging due to the limited spatiotemporal resolution and scalability of magnetic resonance imaging (MRI), as well as the limited precision (±30% error range) and image quality tradeoff of existing ultrasound-based approaches. This study presents an ultrasound-based wall shear imaging (WASHI) framework that simultaneously provides high-quality B-mode images and spatiotemporally resolved WSS maps, and evaluates its accuracy and precision. WASHI derives WSS directly from velocity gradients obtained using transverse oscillation vector flow imaging based on an interleaved synthetic aperture imaging sequence implemented on a Verasonics Vantage 256. Accuracy was assessed using a flow-rig setup under controlled conditions, and in vivo precision was evaluated in ten healthy volunteers through bilateral scans of the common carotid arteries (19 common carotid arteries (CCAs) in total). In the flow-rig experiments, WASHI produced consistent WSS estimates across 0° and 20° tilting angles with accuracy comparable to a velocity-based estimator (bias: -1 versus -3 mPa). In in vivo measurements, WASHI successfully tracked vessel wall motion over multiple cardiac cycles and resolved both spatial and temporal variations in WSS along both vessel walls. The median coefficient of variation (CV) across the 19 CCAs was 10.2%, demonstrating high measurement precision. Although this precision was slightly lower than that of the velocity-based estimator (CV: 6.2%), WASHI produced WSS magnitudes (2.7 and 2.3 Pa) that closely reflected the captured flow profile (2.9 and 2.4 Pa). In addition, the intrasubject variability of time-averaged WSS was the same across participants ( $p=0.45$ ), indicating reproducible performance. These results demonstrate the feasibility of WASHI for precise and reproducible WSS imaging, enabling future longitudinal studies and large-cohort investigations of vascular hemodynamics.

  • Open Access

    Bedside Ultrasound Vector Doppler Imaging System With GPU Processing and Deep Learning

    by Hassan Nahas, Billy Y. S. Yiu, Adrian J. Y. Chee, Takuro Ishii, Alfred C. H. Yu

    Recent innovations in vector flow imaging promise to bring the modality closer to clinical application and allow for more comprehensive high-frame-rate vascular assessments. One such innovation is plane-wave multi-angle vector Doppler, where pulsed Doppler principles from multiple steering angles are used to realize vector flow imaging at frame rates upward of 1,000 frames per second (fps). Currently, vector Doppler is limited by the presence of aliasing artifacts that have prevented its reliable realization at the bedside. In this work, we present a new aliasing-resistant vector Doppler imaging system that can be deployed at the bedside using a programmable ultrasound core, graphics processing unit (GPU) processing, and deep learning principles. The framework supports two operational modes: 1) live imaging at 17 fps where vector flow imaging serves to guide image view navigation in blood vessels with complex dynamics; 2) on-demand replay mode where flow data acquired at high frame rates of over 1,000 fps is depicted as a slow-motion playback at 60 fps using an aliasing-resistant vector projectile visualization. Using our new system, aliasing-free vector flow cineloops were successfully obtained in a stenosis phantom experiment and in human bifurcation imaging scans. This system represents a major engineering advance towards the clinical adoption of vector flow imaging.


  • Open Access

    Precision of in vivo pressure gradient estimations using synthetic aperture ultrasound

    by Lars Emil Haslund, Alexander Cuculiza Henriksen, Billy Yat Shun Yiu, Ali Salari, Marie Sand Traberg, Lasse Thurmann Jørgensen, Borislav Gueorguiev Tomov, Michael Bachmann Nielsen, Jørgen Arendt Jensen


  • Beamformer for a Lensed Row–Column Array in 3-D Ultrasound Imaging

    by Ali Salari, Mélanie Audoin, Borislav Gueorguiev Tomov, Billy Y. S. Yiu, Erik Vilain Thomsen, Jørgen Arendt Jensen

    Row-column (RC) arrays typically suffer from a limited field of view (FOV), with the imaging area confined to a rectangular region equal to the footprint of the probe. This limitation can be solved by using a diverging lens in front of the probe. Previous studies have introduced a Thin Lens model for beamforming lensed RC arrays, but this model inaccurately assumes the lens to be infinitely thin, leading to degraded resolution and contrast due to errors in the time of flight (TOF) calculations. This paper presents a beamformer based on ray tracing for accurate TOF calculation. A Verasonics Vantage 256 scanner was equipped with a Vermon RC probe with 128 + 128 elements, λ pitch, and a 6 MHz center frequency. A synthetic aperture ultrasound sequence with 96 virtual sources and 32 active elements for each emission with row elements was employed, and all column elements were used for acquiring data. This method was tested with a polystyrene (PS) lens with a spherical shape and polymethyl methacrylate (PMMA) in a Bicylindrical shape. Based on pressure field measurements, these two lenses provide a 20° and 33° FOV, respectively. The Thin Lens model had a lateral resolution of around 17.4λ for the Bicylindrical lens, whereas the new method achieves a resolution of around 3.8λ, representing a 4.6-fold improvement. The contrast is enhanced from 23.1 to 29.8 dB for the Bicylindrical lens while preserving the FOV.


  • Open Access

    A Forked Microvascular Phantom for Ultrasound Localization Microscopy Investigations

    by Hanyue Shangguan, Billy Y. S. Yiu, Adrian J. Y. Chee, Alfred C. H. Yu

    In the development of ultrasound localization microscopy (ULM) methods, appropriate test beds are needed to facilitate algorithmic performance calibration. Here, we present the design of a new ULM-compatible microvascular phantom with a forked, V-shaped wall-less flow channel pair (250 μm channel width) that bifurcated at a separation rate of 50 μm/mm. The lumen core was fabricated using additive manufacturing, and it was molded within a polyvinyl alcohol (PVA) tissue mimicking slab using the lost-core casting method. Measured using optical microscopy, the lumen core’s flow channel width was found to be 252±15 μm with a regression-derived flow channel separation gradient of 50.89 μm/mm. The new phantom’s applicability in ULM performance analysis was demonstrated by feeding microbubble contrast flow (1.67 to 167 μl/s flow rates) through the phantom’s inlet and generating ULM images with a previously reported method. Results showed that, with longer acquisition times (10 s or longer), ULM image quality was expectedly improved, and the variance of ULM-derived flow channel measurements was reduced. Also, at axial depths near the lumen’s bifurcation point, the current ULM algorithm showed difficulty in properly discerning between the two flow channels because of the narrow channel-to-channel separation distance. Overall, the new phantom serves well as a calibration tool to test the performance of ULM methods in resolving small vasculature.


  • Open Access

    Branched Convolutional Neural Networks for Receiver Channel Recovery in High-Frame-Rate Sparse-Array Ultrasound Imaging

    by William M. K. Pitman, Di Xiao, Billy Y. S. Yiu, Adrian J. Y. Chee, Alfred C. H. Yu

    For high-frame-rate ultrasound imaging, it remains challenging to implement on compact systems as a sparse imaging configuration with limited array channels. One key issue is that the resulting image quality is known to be mediocre not only because unfocused plane-wave excitations are used, but also because grating lobes would emerge in sparse array configurations. In this paper, we present the design and use of a new channel recovery framework to infer full-array plane-wave channel datasets for periodically sparse arrays that operate with as few as one-quarter of the full-array aperture. This framework is based on a branched encoder-decoder convolutional neural network (CNN) architecture, which was trained using full-array plane-wave channel data collected from human carotid arteries (59,864 training acquisitions; 5 MHz imaging frequency; 20 MHz sampling rate; plane-wave steering angles between -15° and 15° in 1° increments). Three branched encoder-decoder CNNs were separately trained to recover missing channels after differing degrees of channel-wise downsampling (2, 3, and 4-times). The framework’s performance was tested on full-array and downsampled plane-wave channel data acquired from an in vitro point target, human carotid arteries, and human brachioradialis muscle. Results show that, when inferred full-array plane-wave channel data was used for beamforming, spatial aliasing artifacts in the B-mode images were suppressed for all degrees of channel downsampling. Also, the image contrast was enhanced comparing to B-mode images obtained from beamforming with downsampled channel data. When the recovery framework was implemented on an RTX-2080 GPU, the three investigated degrees of downsampling all achieved the same inference time of 4 ms. Overall, the proposed framework shows promise in enhancing the quality of high-frame-rate ultrasound images generated using a sparse-array imaging setup.


  • Open Access

    A GPU-Based, Real-Time Dealiasing Framework for High-Frame-Rate Vector Doppler Imaging

    by Hassan Nahas, Takuro Ishii, Billy Y. S. Yiu, Alfred C. H. Yu

    Vector Doppler is well regarded as a potential way of deriving flow vectors to intuitively visualize complex flow profiles, especially when it is implemented at high frame rates. However, this technique’s performance is known to suffer from aliasing artifacts. There is a dire need to devise real-time dealiasing solutions for vector Doppler. In this paper, we present a new methodological framework for achieving aliasing-resistant flow vector estimation at real-time throughput from precalculated Doppler frequencies. Our framework comprises a series of compute kernels that have synergized: 1) an extended least squares vector Doppler (ELS-VD) algorithm, 2) single-instruction, multiple-thread (SIMT) processing principles, and 3) implementation on a graphical processing unit (GPU). Results show that this new framework, when executed on an RTX-2080 GPU, can effectively generate aliasing-free flow vector maps using high-frame-rate imaging datasets acquired from multiple transmit-receive angle pairs in a carotid phantom imaging scenario. Over the entire cardiac cycle, the frame processing time for aliasing-resistant vector estimation was measured to be less than 16 ms, which corresponds to a minimum processing throughput of 62.5 fps. In a human femoral bifurcation imaging trial with fast flow (150 cm/s), our framework was found to be effective in resolving two-cycle aliasing artifacts at a minimum throughput of 53 fps. The framework’s processing throughput was generally in the real-time range for practical combinations of ELS-VD algorithmic parameters. Overall, this work represents the first demonstration of real-time, GPU-based aliasing-resistant vector flow imaging using vector Doppler estimation principles.


  • Open Access

    Time-Resolved Wall Shear Rate Mapping Using High-Frame-Rate Ultrasound Imaging

    by Adrian J. Y. Chee, Chung Kit Ho, Billy Y. S. Yiu, Alfred C. H. Yu

    In atherosclerosis, low wall shear stress (WSS) is known to favor plaque development while high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is crucial. Here we propose wall shear imaging (WASHI), a non-invasive contrast-free framework that leverages high-frame-rate ultrasound to map wall shear rate (WSR) that relates to WSS by the blood viscosity coefficient. Our method measures WSR as the tangential flow velocity gradient along the arterial wall from flow vector field derived using multi-angle vector Doppler technique. To improve WSR estimation performance, WASHI semi-automatically tracks the wall position throughout the cardiac cycle. WASHI was first evaluated with an in vitro linear WSR gradient model; the estimated WSR was consistent with theoretical values (average error of 4.6 ± 12.4%). The framework was then tested on healthy and diseased carotid bifurcation models. In both scenarios, key spatiotemporal dynamics of WSR were noted: (i) Oscillating shear patterns were present in the carotid bulb and downstream to the ICA where retrograde flow occurs; (ii) High WSR was observed particularly in the diseased model where measured WSR peaked at 810 s -1 due to flow jet. We also showed that WASHI could consistently track arterial wall motion to map its WSR. Overall, WASHI enables high temporal resolution mapping of WSR that could facilitate investigations on causal effects between WSS and atherosclerosis.


  • Array Transducer Design: A Vibrant Research Theme in Medical Ultrasonics

    by Alessandro Ramalli, Hendrik J. Vos, Billy Y. S. Yiu

    Since the 1970s, when portable transducer arrays were first introduced for medical ultrasound imaging, they have undergone substantial technological developments. The development of advanced arrays is often motivated by the need to achieve high diagnostic and therapeutic efficacy and to serve new fields of application. In the past few decades, medical ultrasound array design has been an active research area with challenging technical requirements that continually seek to reduce physical size, improve sensitivity, optimize the number of array elements, realize wide bandwidth, and achieve high output power. The need to devise arrays with increased performance has concurrently stimulated advances in transducer technologies, microelectronics, and array layout design. Nowadays, representative examples can be found for both 2-D and 3-D applications such as high-intensity-focused ultrasound arrays, very-high-frequency or dual-frequency probes, kerf-less arrays, 2-D sparse arrays, and probes with embedded application-specific integrated circuits. The emergence of these advanced arrays has, in turn, stimulated the development of novel, customized transmission and reception approaches, image reconstruction algorithms, and data recovery strategies to exploit or deal with the peculiarities of a specific array.