Veronika Novotna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Veronika Novotna has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Dalibor Cervinka
FEEC BUT
2 shared publications - Dalibor Cervinka
Faculty of Electrical Engineering and Communication, Department of Power Electrical and Electronic Engineering, Brno University of Technology
2 shared publications Jan Neuman
NenoVision s.r.o, Brno, Czech Republic, EU
2 shared publications- Peter Matkulcik
Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno
2 shared publications - Shraga Nahum Goldberg
Division of Image-Guided Therapy, Department of Radiology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
2 shared publications - Tomas Rohan
Faculty of Medicine Masaryk University Brno Czechia
2 shared publications
Latest Publications
- Open Access
- 2 July 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2520362
Mathematical modeling of the effect of stent construction during endoluminal IRE for recanalization of an occluded metal stent
Intraluminal irreversible electroporation (IRE) can be used for recanalizing occluded metal stents. However, optimal IRE parameters for consistent effects across different stent designs remain unclear. The aim of this study was to simulate the process of stent recanalization in silico by employing finite element analysis. A virtual model of an occluded biliary stent with an experimental 3-electrode IRE catheter was developed. Electric field distribution, temperature changes, and potential ablation volumes were simulated across various parameters: IRE voltage (300 - 1300 V), stent wire width (0.1 - 0.5 mm) and stent mesh size (0.7 - 5.58 mm). Simulations incorporated five representative stent types commonly used in clinical practice. 685 unique simulations were conducted, analyzing 1162 unique values. Higher voltages generally led to larger ablation zones and increased temperatures. Thinner stent wires and larger mesh sizes also increased the extent of ablation zone. While in-stent ablation was largely independent of stent design, out-of-stent ablation was significantly impacted by mesh size and tissue thickness between the stent and irreversible electroporation electrodes. Voltages above 1000 V produced significant thermal effects, with substantial volumes of tissue heated above 50 °C. Specific stent designs exhibited variations in maximum temperature (72.1 - 83.1 °C) and ablation volume (8.7 - 14.7 mm3). Tailored IRE protocols for different stent designs are required due to differences in in- and out-stent ablation volumes. High voltages (>1000 V) induce both thermal and nonthermal ablation mechanisms.
- 2 July 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2520362
Open AccessMathematical modeling of the effect of stent construction during endoluminal IRE for recanalization of an occluded metal stent
Intraluminal irreversible electroporation (IRE) can be used for recanalizing occluded metal stents. However, optimal IRE parameters for consistent effects across different stent designs remain unclear. The aim of this study was to simulate the process of stent recanalization in silico by employing finite element analysis. A virtual model of an occluded biliary stent with an experimental 3-electrode IRE catheter was developed. Electric field distribution, temperature changes, and potential ablation volumes were simulated across various parameters: IRE voltage (300 - 1300 V), stent wire width (0.1 - 0.5 mm) and stent mesh size (0.7 - 5.58 mm). Simulations incorporated five representative stent types commonly used in clinical practice. 685 unique simulations were conducted, analyzing 1162 unique values. Higher voltages generally led to larger ablation zones and increased temperatures. Thinner stent wires and larger mesh sizes also increased the extent of ablation zone. While in-stent ablation was largely independent of stent design, out-of-stent ablation was significantly impacted by mesh size and tissue thickness between the stent and irreversible electroporation electrodes. Voltages above 1000 V produced significant thermal effects, with substantial volumes of tissue heated above 50 °C. Specific stent designs exhibited variations in maximum temperature (72.1 - 83.1 °C) and ablation volume (8.7 - 14.7 mm3). Tailored IRE protocols for different stent designs are required due to differences in in- and out-stent ablation volumes. High voltages (>1000 V) induce both thermal and nonthermal ablation mechanisms.
- Open Access
- 7 February 2024
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 15 (1) , 190-198
Graphene removal by water-assisted focused electron-beam-induced etching – unveiling the dose and dwell time impact on the etch profile and topographical changes in SiO2 substrates
Graphene is one of the most extensively studied 2D materials, exhibiting extraordinary mechanical and electronic properties. Although many years have passed since its discovery, manipulating single graphene layers is still challenging using standard resist-based lithography techniques. Recently, it has been shown that it is possible to etch graphene directly in water-assisted processes using the so-called focused electron-beam-induced etching (FEBIE), with a spatial resolution of ten nanometers. Nanopatterning graphene with such a method in one single step and without using a physical mask or resist is a very appealing approach. During the process, on top of graphene nanopatterning, we have found significant morphological changes induced in the SiO2 substrate even at low electron dose values (2). We demonstrate that graphene etching and topographical changes in SiO2 substrates can be controlled via electron beam parameters such as dwell time and dose.
- 7 February 2024
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 15 (1) , 190-198
Open AccessGraphene removal by water-assisted focused electron-beam-induced etching – unveiling the dose and dwell time impact on the etch profile and topographical changes in SiO2 substrates
Graphene is one of the most extensively studied 2D materials, exhibiting extraordinary mechanical and electronic properties. Although many years have passed since its discovery, manipulating single graphene layers is still challenging using standard resist-based lithography techniques. Recently, it has been shown that it is possible to etch graphene directly in water-assisted processes using the so-called focused electron-beam-induced etching (FEBIE), with a spatial resolution of ten nanometers. Nanopatterning graphene with such a method in one single step and without using a physical mask or resist is a very appealing approach. During the process, on top of graphene nanopatterning, we have found significant morphological changes induced in the SiO2 substrate even at low electron dose values (2). We demonstrate that graphene etching and topographical changes in SiO2 substrates can be controlled via electron beam parameters such as dwell time and dose.
- Open Access
- 23 March 2021
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 197 (5) , 461-462
Correction to: Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
- 23 March 2021
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 197 (5) , 461-462
Open AccessCorrection to: Cardiac doses of accelerated partial breast irradiation with perioperative multicatheter interstitial brachytherapy
- Open Access
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 393-401
Experimental model of occluded biliary metal stent recanalization using irreversible electroporation via a tubular catheter
To demonstrate the feasibility of irreversible electroporation (IRE) for treating biliary metal stent occlusion in an experimental liver model.IRE was performed using an expandable tubular IRE-cath...
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 393-401
Open AccessExperimental model of occluded biliary metal stent recanalization using irreversible electroporation via a tubular catheter
To demonstrate the feasibility of irreversible electroporation (IRE) for treating biliary metal stent occlusion in an experimental liver model.IRE was performed using an expandable tubular IRE-cath...
- Open Access
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 568-572
LITESCOPE™ AFM-IN-SEM: ADVANCED TOOL FOR CORRELATIVE IMAGING AND SURFACE CHARACTERIZATION
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 568-572
Open AccessLITESCOPE™ AFM-IN-SEM: ADVANCED TOOL FOR CORRELATIVE IMAGING AND SURFACE CHARACTERIZATION
- Open Access
- 14 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection
For the first time, the combination of molecularly imprinted polymer (MIP) technology with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented with focus on an optimization of the LA-ICP-MS parameters such as laser beam diameter, laser beam fluence, and scan speed using CdS quantum dots (QDs) as a template and dopamine as a functional monomer. A non-covalent imprinting approach was employed in this study due to the simplicity of preparation. Simple oxidative polymerization of the dopamine that creates the self-assembly monolayer seems to be an ideal choice. The QDs prepared by UV light irradiation synthesis were stabilized by using mercaptosuccinic acid. Formation of a complex of QD-antibody and QD-antibody-antigen was verified by using capillary electrophoresis with laser-induced fluorescence detection. QDs and antibody were connected together via an affinity peptide linker. LA-ICP-MS was employed as a proof-of-concept for detection method of two types of immunoassay: 1) antigen extracted from the sample by MIP and subsequently overlaid/immunoreacted by QD-labelled antibodies, 2) complex of antigen, antibody, and QD formed in the sample and subsequently extracted by MIP. The first approach provided higher sensitivity (MIP/NIP), however, the second demonstrated higher selectivity. A mixture of proteins with size in range 10–250 kDa was used as a model sample to demonstrate the capability of both approaches for detection of IgG in a complex sample.
- 14 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessCdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection
For the first time, the combination of molecularly imprinted polymer (MIP) technology with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented with focus on an optimization of the LA-ICP-MS parameters such as laser beam diameter, laser beam fluence, and scan speed using CdS quantum dots (QDs) as a template and dopamine as a functional monomer. A non-covalent imprinting approach was employed in this study due to the simplicity of preparation. Simple oxidative polymerization of the dopamine that creates the self-assembly monolayer seems to be an ideal choice. The QDs prepared by UV light irradiation synthesis were stabilized by using mercaptosuccinic acid. Formation of a complex of QD-antibody and QD-antibody-antigen was verified by using capillary electrophoresis with laser-induced fluorescence detection. QDs and antibody were connected together via an affinity peptide linker. LA-ICP-MS was employed as a proof-of-concept for detection method of two types of immunoassay: 1) antigen extracted from the sample by MIP and subsequently overlaid/immunoreacted by QD-labelled antibodies, 2) complex of antigen, antibody, and QD formed in the sample and subsequently extracted by MIP. The first approach provided higher sensitivity (MIP/NIP), however, the second demonstrated higher selectivity. A mixture of proteins with size in range 10–250 kDa was used as a model sample to demonstrate the capability of both approaches for detection of IgG in a complex sample.
- 19 August 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 80-86
High-Voltage Pulse Source for Cell Electroporation
- 19 August 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 80-86
High-Voltage Pulse Source for Cell Electroporation
- Open Access
- 1 August 2016
- Published by Scientific Scholar in Indian Journal of Medical Research
- Vol. 144 (2) , 229-237
Circulating heat shock protein mRNA profile in gestational hypertension, pre-eclampsia & foetal growth restriction
Background & objectives: Heat shock proteins (Hsp) are ubiquitously distributed phylogenetically conserved molecules that regulate cellular homeostasis and maintain the integrity and function of cellular proteins. Increased levels of Hsp in maternal circulation have been shown to be associated with increased risk of pregnancy related complications. The objective of this study was to explore extracellular Hsp mRNA levels in maternal circulation and quantified Hsp27, Hsp60, Hsp70, Hsp90 and Hsp70 binding protein 1 (HspBP1) mRNAs in maternal plasma samples using real-time reverse-transcriptase polymerase chain reaction. Methods: Pregnancies with gestational hypertension (GH) (n = 33), pre-eclampsia (PE) with or without foetal growth restriction (FGR) (n = 78) and FGR (n = 25) were involved in the study. Hsp gene expression was analysed in relation to the severity of the disease with respect to the degree of clinical signs, requirements for the delivery and Doppler ultrasound parameters. Results: Upregulation of Hsp70 was observed in patients with mild and severe PE (P = 0.004 and P = 0.005, respectively) and in pregnancies complicated with PE delivering before and after 34 wk of gestation regardless of the degree of clinical signs (P = 0.015 and P = 0.009, respectively). No difference in the expression of other Hsp genes among the studied groups was observed. No association between Hsp gene expression and Doppler ultrasonography parameters was found. Interpretation & conclusions: These data support that maternal circulation can reflect both maternal and foetal pathologic conditions. Hsp70 represents the sole plasmatic marker, and increased Hsp70 mRNA levels reflect maternal and placental stress response to pregnancy-related complications such as GH and PE, irrespective of the severity of the disease.
- 1 August 2016
- Published by Scientific Scholar in Indian Journal of Medical Research
- Vol. 144 (2) , 229-237
Open AccessCirculating heat shock protein mRNA profile in gestational hypertension, pre-eclampsia & foetal growth restriction
Background & objectives: Heat shock proteins (Hsp) are ubiquitously distributed phylogenetically conserved molecules that regulate cellular homeostasis and maintain the integrity and function of cellular proteins. Increased levels of Hsp in maternal circulation have been shown to be associated with increased risk of pregnancy related complications. The objective of this study was to explore extracellular Hsp mRNA levels in maternal circulation and quantified Hsp27, Hsp60, Hsp70, Hsp90 and Hsp70 binding protein 1 (HspBP1) mRNAs in maternal plasma samples using real-time reverse-transcriptase polymerase chain reaction. Methods: Pregnancies with gestational hypertension (GH) (n = 33), pre-eclampsia (PE) with or without foetal growth restriction (FGR) (n = 78) and FGR (n = 25) were involved in the study. Hsp gene expression was analysed in relation to the severity of the disease with respect to the degree of clinical signs, requirements for the delivery and Doppler ultrasound parameters. Results: Upregulation of Hsp70 was observed in patients with mild and severe PE (P = 0.004 and P = 0.005, respectively) and in pregnancies complicated with PE delivering before and after 34 wk of gestation regardless of the degree of clinical signs (P = 0.015 and P = 0.009, respectively). No difference in the expression of other Hsp genes among the studied groups was observed. No association between Hsp gene expression and Doppler ultrasonography parameters was found. Interpretation & conclusions: These data support that maternal circulation can reflect both maternal and foetal pathologic conditions. Hsp70 represents the sole plasmatic marker, and increased Hsp70 mRNA levels reflect maternal and placental stress response to pregnancy-related complications such as GH and PE, irrespective of the severity of the disease.
- 27 August 2014
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 20 (S3) , 1270-1271
Investigation of Electron Beam Induced Mass Loss of Embedding Media in the Low Voltage STEM
- 27 August 2014
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 20 (S3) , 1270-1271
Investigation of Electron Beam Induced Mass Loss of Embedding Media in the Low Voltage STEM