Jun-Young Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jun-Young Park has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Sung Ho Cho
Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
4 shared publications Hyun-Kyung Park
Department of Pediatrics, College of Medicine, Hanyang University, Seoul, Republic of Korea
2 shared publicationsRan Heo
Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul, Republic of Korea
2 shared publications- Seok Hyun Cho
Department of Otolaryngology-Head and Neck Surgery, Hanyang University College of Medicine, 222-1, Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea
2 shared publications Yeon-Woo Choi
Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul, Republic of Korea
2 shared publicationsYonggu Lee
Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 2 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1
Author Correction: Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
- 2 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1
Open AccessAuthor Correction: Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
- Open Access
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 138496-138508
Noncontact Extraction of Biomechanical Parameters in Gait Analysis Using a Multi-Input and Multi-Output Radar Sensor
Gait analysis is one of the most basic methods for assessing a patient’s biopsychological status. Doctors can distinguish people with mental and neurological disorders by monitoring their gait. To perform gait analysis in a more quantitative and accurate manner, many studies have used inertial measurement units (IMUs), cameras and ground reaction force platforms. However, conventional gait analysis requires sensors to be attached to the subject’s body, and some of them are cost prohibitive. Currently, studies of noncontact gait analysis using radar sensors are being performed. Such studies have successfully measured several gait parameters associated with the noncontact method but have been unable to distinguish between individual legs. In this study, we proposed a method for noncontact gait analysis with a treadmill that could separate the left and right legs using multi-input and multi-output frequency-modulated continuous-wave (MIMO FMCW) radar. By recognizing two legs in a range-Doppler map and estimating their angles, ranges and velocities, the gait parameters of the individual legs could be identified. We performed experiments with 15 participants in 4 scenarios (walking, running, left leg limping, right leg limping) and compared gait parameters obtained using FMCW radar and IMUs. The gait parameter measurements were validated using the intraclass correlation value, and they showed excellent agreement except for flight time. Moreover, a parameter was identified that can accurately detect gait asymmetry, and its sensitivity (0.83) and specificity (1.00) were validated. Our future research will analyze not only feet movement but also arm movement so that it can be further applied to the medical field.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 138496-138508
Open AccessNoncontact Extraction of Biomechanical Parameters in Gait Analysis Using a Multi-Input and Multi-Output Radar Sensor
Gait analysis is one of the most basic methods for assessing a patient’s biopsychological status. Doctors can distinguish people with mental and neurological disorders by monitoring their gait. To perform gait analysis in a more quantitative and accurate manner, many studies have used inertial measurement units (IMUs), cameras and ground reaction force platforms. However, conventional gait analysis requires sensors to be attached to the subject’s body, and some of them are cost prohibitive. Currently, studies of noncontact gait analysis using radar sensors are being performed. Such studies have successfully measured several gait parameters associated with the noncontact method but have been unable to distinguish between individual legs. In this study, we proposed a method for noncontact gait analysis with a treadmill that could separate the left and right legs using multi-input and multi-output frequency-modulated continuous-wave (MIMO FMCW) radar. By recognizing two legs in a range-Doppler map and estimating their angles, ranges and velocities, the gait parameters of the individual legs could be identified. We performed experiments with 15 participants in 4 scenarios (walking, running, left leg limping, right leg limping) and compared gait parameters obtained using FMCW radar and IMUs. The gait parameter measurements were validated using the intraclass correlation value, and they showed excellent agreement except for flight time. Moreover, a parameter was identified that can accurately detect gait asymmetry, and its sensitivity (0.83) and specificity (1.00) were validated. Our future research will analyze not only feet movement but also arm movement so that it can be further applied to the medical field.
- Open Access
- 12 April 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-9
UWB-gestures, a public dataset of dynamic hand gestures acquired using impulse radar sensors
In the past few decades, deep learning algorithms have become more prevalent for signal detection and classification. To design machine learning algorithms, however, an adequate dataset is required. Motivated by the existence of several open-source camera-based hand gesture datasets, this descriptor presents UWB-Gestures, the first public dataset of twelve dynamic hand gestures acquired with ultra-wideband (UWB) impulse radars. The dataset contains a total of 9,600 samples gathered from eight different human volunteers. UWB-Gestures eliminates the need to employ UWB radar hardware to train and test the algorithm. Additionally, the dataset can provide a competitive environment for the research community to compare the accuracy of different hand gesture recognition (HGR) algorithms, enabling the provision of reproducible research results in the field of HGR through UWB radars. Three radars were placed at three different locations to acquire the data, and the respective data were saved independently for flexibility.
- 12 April 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-9
Open AccessUWB-gestures, a public dataset of dynamic hand gestures acquired using impulse radar sensors
In the past few decades, deep learning algorithms have become more prevalent for signal detection and classification. To design machine learning algorithms, however, an adequate dataset is required. Motivated by the existence of several open-source camera-based hand gesture datasets, this descriptor presents UWB-Gestures, the first public dataset of twelve dynamic hand gestures acquired with ultra-wideband (UWB) impulse radars. The dataset contains a total of 9,600 samples gathered from eight different human volunteers. UWB-Gestures eliminates the need to employ UWB radar hardware to train and test the algorithm. Additionally, the dataset can provide a competitive environment for the research community to compare the accuracy of different hand gesture recognition (HGR) algorithms, enabling the provision of reproducible research results in the field of HGR through UWB radars. Three radars were placed at three different locations to acquire the data, and the respective data were saved independently for flexibility.
- Open Access
- 15 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice.
- 15 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessPreclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice.