Noncontact Extraction of Biomechanical Parameters in Gait Analysis Using a Multi-Input and Multi-Output Radar Sensor
Open Access
- 4 October 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 138496-138508
Abstract
Gait analysis is one of the most basic methods for assessing a patient’s biopsychological status. Doctors can distinguish people with mental and neurological disorders by monitoring their gait. To perform gait analysis in a more quantitative and accurate manner, many studies have used inertial measurement units (IMUs), cameras and ground reaction force platforms. However, conventional gait analysis requires sensors to be attached to the subject’s body, and some of them are cost prohibitive. Currently, studies of noncontact gait analysis using radar sensors are being performed. Such studies have successfully measured several gait parameters associated with the noncontact method but have been unable to distinguish between individual legs. In this study, we proposed a method for noncontact gait analysis with a treadmill that could separate the left and right legs using multi-input and multi-output frequency-modulated continuous-wave (MIMO FMCW) radar. By recognizing two legs in a range-Doppler map and estimating their angles, ranges and velocities, the gait parameters of the individual legs could be identified. We performed experiments with 15 participants in 4 scenarios (walking, running, left leg limping, right leg limping) and compared gait parameters obtained using FMCW radar and IMUs. The gait parameter measurements were validated using the intraclass correlation value, and they showed excellent agreement except for flight time. Moreover, a parameter was identified that can accurately detect gait asymmetry, and its sensitivity (0.83) and specificity (1.00) were validated. Our future research will analyze not only feet movement but also arm movement so that it can be further applied to the medical field.Keywords
Funding Information
- Bio & Medical Technology Development Program of the National Research Foundation (NRF), funded by the Korean Government [Ministry of Science and ICT (MSIT)] (2017M3A9E2064626)
This publication has 33 references indexed in Scilit:
- Assistive Smart Sensing Devices for Gait Rehabilitation Monitoring2015
- Joint DFT-ESPRIT Estimation for TOA and DOA in Vehicle FMCW RadarsIEEE Antennas and Wireless Propagation Letters, 2015
- A real-time fall detection system using a wearable gait analysis sensor and a Support Vector Machine (SVM) classifier2015
- High-Dimensional Cluster Analysis with the Masked EM AlgorithmNeural Computation, 2014
- Measurements and sensors for motion tracking in motor rehabilitationIEEE Instrumentation & Measurement Magazine, 2014
- Quantitative Gait Measurement With Pulse-Doppler Radar for Passive In-Home Gait AssessmentIEEE Transactions on Biomedical Engineering, 2014
- Strength Asymmetry Increases Gait Asymmetry and Variability in Older WomenMedicine & Science in Sports & Exercise, 2012
- A robust EM clustering algorithm for Gaussian mixture modelsPattern Recognition, 2012
- Reliability and clinical correlates of 3D-accelerometry based gait analysis outcomes according to age and fall-riskGait & Posture, 2011
- Gait asymmetry in patients with Parkinson’s disease and elderly fallers: when does the bilateral coordination of gait require attention?Experimental Brain Research, 2006