    Effects of count rate performance on image quality in an LAFOV PET/CT system

    by Nanna Overbeck, Zuzanna Czeluśniak, Søren Holm, Julie V Henriksen, Flemming Littrup Andersen, Thomas Lund Andersen

    The development of Long Axial Field-of-View positron emission tomography combined with computed tomography warrants reconsideration of the administered activity required for clinical imaging. This study investigated the relationship between body size, administered activity ( 18 F), and image quality (IQ) using two patient-like phantoms representing normal (78.5 kg) and obese (194.3 kg) body profiles. The phantoms were scanned in selected five-minute periods within a total duration of 27 and 21 h, respectively, following the decay of the activity. Analysis of the trues, scatter, and randoms demonstrated a close to linear propagation of the trues with activity up to a point where saturation was reached. The normal body profile phantom achieved higher signal-to-noise ratios (SNRs), reaching system saturation at a lower activity (680 MBq) than the large phantom, representing the obese body profile (970 MBq). The SNR 2 showed a nonlinear correlation with the noise equivalent count rate, whereas SNR 2 had a linear correlation with the trues. The study demonstrated the count rate capabilities up to and beyond the saturation limit. Furthermore, we illustrated the possibilities of scanning patients with ultralow dose administration in the range of 0.03–0.07 MBq kg −1 body weight. However, achieving robust clinical diagnostic quality—particularly for low-contrast lesions—at these activity levels requires further clinical investigation. Utilising these ultralow activity concentrations requires extending the scan duration to compensate for IQ, especially when examining obese patients.

  • Open Access

    Preemptive iodide treatment in the event of a nuclear disaster: The prepper's guide to the galaxy

    by Per Karkov Cramon, Søren Holm, Ronan M. G. Berg

  • Open Access

    EANM guidance document: dosimetry for first-in-human studies and early phase clinical trials

    by Caroline Stokke, Silvano Gnesin, Johannes Tran-Gia, Francesco Cicone, Søren Holm, Marta Cremonesi, Johan Blakkisrud, Thomas Wendler, Nic Gillings, Ken Herrmann, et al.

    The numbers of diagnostic and therapeutic nuclear medicine agents under investigation are rapidly increasing. Both novel emitters and novel carrier molecules require careful selection of measurement procedures. This document provides guidance relevant to dosimetry for first-in human and early phase clinical trials of such novel agents. The guideline includes a short introduction to different emitters and carrier molecules, followed by recommendations on the methods for activity measurement, pharmacokinetic analyses, as well as absorbed dose calculations and uncertainty analyses. The optimal use of preclinical information and studies involving diagnostic analogues is discussed. Good practice reporting is emphasised, and relevant dosimetry parameters and method descriptions to be included are listed. Three examples of first-in-human dosimetry studies, both for diagnostic tracers and radionuclide therapies, are given.


  • Open Access

    Towards a model of biliary atresia - Pilot feasibility study in newborn piglets

    by Thora Wesenberg Helt, Lene Buelund, Lise Borgwardt, Thomas Eriksen, Lars Johansen, Robin de Nijs, Soren Holm, Douglas G. Burrin, Thomas Thymann, Vibeke Brix Christensen

  • Open Access

    First-in-Human Study of [68Ga]Ga-NODAGA-E[c(RGDyK)]2 PET for Integrin αvβ3 Imaging in Patients with Breast Cancer and Neuroendocrine Neoplasms: Safety, Dosimetry and Tumor Imaging Ability

    by Malene Martini Clausen, Esben Andreas Carlsen, Camilla Christensen, Jacob Madsen, Malene Brandt-Larsen, Thomas Levin Klausen, Søren Holm, Annika Loft, Anne Kiil Berthelsen, Niels Kroman, et al.

    Arginine-Glycine-Aspartate (RGD)-recognizing cell surface integrins are involved in tumor growth, invasiveness/metastases, and angiogenesis, and are therefore an attractive treatment target in cancers. The subtype integrin αvβ3 is upregulated on endothelial cells during angiogenesis and on tumor cells. In vivo assessment of integrin αvβ3 is possible with positron emission tomography (PET). Preclinical data on radiochemical properties, tumor uptake and radiation exposure identified [68Ga]Ga-NODAGA-E[c(RGDyK)]2 as a promising candidate for clinical translation. In this first-in-human phase I study, we evaluate [68Ga]Ga-NODAGA-E[c(RGDyK)]2 PET in patients with neuroendocrine neoplasms (NEN) and breast cancer (BC). The aim was to investigate safety, biodistribution and dosimetry as well as tracer uptake in tumor lesions. A total of 10 patients (5 breast cancer, 5 neuroendocrine neoplasm) received a single intravenous dose of approximately 200 MBq [68Ga]Ga-NODAGA-E[c(RGDyK)]2. Biodistribution profile and dosimetry were assessed by whole-body PET/CT performed at 10 min, 1 h and 2 h after injection. Safety assessment with vital parameters, electrocardiograms and blood tests were performed before and after injection. In vivo stability of [68Ga]Ga-NODAGA-E[c(RGDyK)]2 was determined by analysis of blood and urine. PET images were analyzed for tracer uptake in tumors and background organs. No adverse events or pharmacologic effects were observed in the 10 patients. [68Ga]Ga-NODAGA-E[c(RGDyK)]2 exhibited good in vivo stability and fast clearance, primarily by renal excretion. The effective dose was 0.022 mSv/MBq, equaling a radiation exposure of 4.4 mSv at an injected activity of 200 MBq. The tracer demonstrated stable tumor retention and good image contrast. In conclusion, this first-in-human phase I trial demonstrated safe use of [68Ga]Ga-NODAGA-E[c(RGDyK)]2 for integrin αvβ3 imaging in cancer patients, low radiation exposure and favorable uptake in tumors. Further studies are warranted to establish whether [68Ga]Ga-NODAGA-E[c(RGDyK)]2 may become a tool for early identification of patients eligible for treatments targeting integrin αvβ3 and for risk stratification of patients.


  • Open Access

    Assessment of Liver Fat: Dual-Energy CT versus Conventional CT with and without Contrast

    by Jack Junchi Xu, Mikkel Ranum Boesen, Sofie Lindskov Hansen, Peter Sommer Ulriksen, Søren Holm, Lars Lönn, Kristoffer Lindskov Hansen

    We assessed the correlation between liver fat percentage using dual-energy CT (DECT) and Hounsfield unit (HU) measurements in contrast and non-contrast CT. This study included 177 patients in two patient groups: Group A (n = 125) underwent whole body non-contrast DECT and group B (n = 52) had a multiphasic DECT including a conventional non-contrast CT. Three regions of interest were placed on each image series, one in the left liver lobe and two in the right to measure Hounsfield Units (HU) as well as liver fat percentage. Linear regression analysis was performed for each group as well as combined. Receiver operating characteristic (ROC) curve was generated to establish the optimal fat percentage threshold value in DECT for predicting a non-contrast threshold of 40 HU correlating to moderate-severe liver steatosis. We found a strong correlation between fat percentage found with DECT and HU measured in non-contrast CT in group A and B individually (R2 = 0.81 and 0.86, respectively) as well as combined (R2 = 0.85). No significant difference was found when comparing venous and arterial phase DECT fat percentage measurements in group B (p = 0.67). A threshold of 10% liver fat found with DECT had 95% sensitivity and 95% specificity for the prediction of a 40 HU threshold using non-contrast CT. In conclusion, liver fat quantification using DECT shows high correlation with HU measurements independent of scan phase.


  • Open Access

    Human biodistribution and radiation dosimetry of the 5-HT2A receptor agonist Cimbi-36 labeled with carbon-11 in two positions

    by Annette Johansen, Søren Holm, Bente Dall, Sune Keller, Jesper L. Kristensen, Gitte M. Knudsen, Hanne D. Hansen

    Cimbi-36 can be 11C-labeled to form an agonist radioligand used for positron emission tomography (PET) imaging of the 5-HT2A receptor in the brain. In its non-labeled form (25B-NBOMe), it is used as a recreational drug that can lead to severe adverse effects, in some cases, with fatal outcome. We investigated human biodistribution and radiation dosimetry of the radioligand with two different radiolabeling positions. Seven healthy volunteers underwent dynamic 120-min whole-body PET scans (injection of 581 ± 16 MBq, n = 5 for 11C-Cimbi-36; 593 ± 14 MBq, n = 2 for 11C-Cimbi-36_5). Time-integrated activity coefficients (TIACs) from time-activity curves (TACs) of selected organs were used as input into the OLINDA/EXM software to obtain dosimetry information for both 11C-labeling positions of Cimbi-36. The effective dose was only slightly higher for 11C-Cimbi-36 (5.5 μSv/MBq) than for 11C-Cimbi-36_5 (5.3 μSv/MBq). Standard uptake value (SUV) curves showed higher uptake of 11C-Cimbi-36 in the pancreas, small intestines, liver, kidney, gallbladder, and urinary bladder compared with 11C-Cimbi-36_5, reflecting differences in radiometabolism for the two radioligands. Variability in uptake in excretory organs for 11C-Cimbi-36 points to inter-individual differences with regard to metabolic rate and route. Surprisingly, moderate uptake was found in brown adipose tissue (BAT) in four subjects, possibly representing specific 5-HT2A/2C receptor binding. The low effective dose of 5.5 μSv/MBq allows for the injection of up to 1.8 GBq for healthy volunteers per study (equivalent to 3 scans if injecting 600 MBq) and still stay below the international guidelines of 10 mSv, making 11C-Cimbi-36 eligible for studies involving a series of PET scans in a single subject. The biodistribution of Cimbi-36 (and its metabolites) may also help to shed light on the toxic effects of 25B-NBOMe when used in pharmacological doses in recreational settings.


  • Open Access

    Optimized MLAA for quantitative non-TOF PET/MR of the brain

    by Didier Benoit, Claes N Ladefoged, Ahmadreza Rezaei, Sune H Keller, Flemming L Andersen, Liselotte Højgaard, Adam E Hansen, Søren Holm, Johan Nuyts

    For quantitative tracer distribution in positron emission tomography, attenuation correction is essential. In a hybrid PET/CT system the CT images serve as a basis for generation of the attenuation map, but in PET/MR, the MR images do not have a similarly simple relationship with the attenuation map. Hence attenuation correction in PET/MR systems is more challenging. Typically either of two MR sequences are used: the Dixon or the ultra-short time echo (UTE) techniques. However these sequences have some well-known limitations. In this study, a reconstruction technique based on a modified and optimized non-TOF MLAA is proposed for PET/MR brain imaging. The idea is to tune the parameters of the MLTR applying some information from an attenuation image computed from the UTE sequences and a T1w MR image. In this MLTR algorithm, an parameter is introduced and optimized in order to drive the algorithm to a final attenuation map most consistent with the emission data. Because the non-TOF MLAA is used, a technique to reduce the cross-talk effect is proposed. In this study, the proposed algorithm is compared to the common reconstruction methods such as OSEM using a CT attenuation map, considered as the reference, and OSEM using the Dixon and UTE attenuation maps. To show the robustness and the reproducibility of the proposed algorithm, a set of 204 [18F]FDG patients, 35 [11C]PiB patients and 1 [18F]FET patient are used. The results show that by choosing an optimized value of in MLTR, the proposed algorithm improves the results compared to the standard MR-based attenuation correction methods (i.e. OSEM using the Dixon or the UTE attenuation maps), and the cross-talk and the scale problem are limited.


  • The Reduction of Baseline Serotonin 2A Receptors in Mild Cognitive Impairment is Stable at Two-year Follow-up

    by Lisbeth Marner, Gitte M. Knudsen, Karine Madsen, Søren Holm, William Baaré, Steen G. Hasselbalch

    We previously demonstrated a 20-30% reduction in cortical 5-HT2A receptor binding in patients with mild cognitive impairment (MCI) as compared to healthy subjects. Here we present a two-year follow-up of 14 patients and 12 healthy age-matched subjects. Baseline and follow-up partial volume corrected levels of 5-HT2A in four neocortical lobes and the posterior cingulate gyrus were investigated using [18F]altanserin positron emission tomography with a bolus-infusion approach. In the two-year follow-up period, 8 of 14 patients with MCI had progressed to fulfill diagnostic criteria for probable Alzheimer's disease (AD). In both patients and healthy subjects, no significant change in 5-HT2A receptor binding was found as compared to baseline values. In MCI patients, the average BPP in neocortex ranged from 1.49 to 2.45 at baseline and 1.38 to 2.29 at two-year follow-up; and in healthy subjects BPP ranged from 1.85 to 3.10 at baseline and 1.81 to 2.98 at two-year follow-up. The BPP of the patients that converted to AD during the follow-up period did not differ significantly from the patients that had not (yet) converted, neither at baseline, nor at follow-up. We conclude that the reduced levels of 5-HT2A receptor binding in MCI patients decrease only slowly and non-significantly, even in patients who convert to AD. Our finding suggests that profoundly reduced cortical 5-HT2A receptor binding is an early feature in MCI whereas the clinical progression from MCI to AD is less associated with further decrease in binding.


  • Component-based normalization for the HRRT for sinogram-mode reconstruction

    by Merence Sibomana, Sune Hogild Keller, Soren Holm, Peter M. Bloomfield, Stephan Blinder, Soren Baarsgaard Hansen, Christian Michel

    THE Siemens HRRT scanner is a complex PET tomograph, using 8 LSO/LYSO panel detectors and Depth Of Interaction(DOI) with a total of 119908 detector crystals. The Direct Normalization (DN) is the standard method used for sinogram-mode reconstruction. This paper investigates the use of an improved component-based normalization method for HRRT sinogram reconstruction. This method is originally used for MOLAR LOR listmode reconstruction.Three effects have been identified in the implementation of the original method that caused artifacts and quantification bias in the reconstructed uniformity image. The new CBN method has been implemented that corrects for these effects and produces a uniformity image with the same quality as the DN method. The main effect was the sensitivity drop for LORs with small angles of incidence, which affects all scanners by design.