Haotian Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haotian Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Junfeng Rao
University of Science and Technology of China
5 shared publications - Song Jiang
University of Shanghai for Science and Technology
4 shared publications - Zi Li
Department of Electrical Engineering, School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai, China
4 shared publications - Hui Zhao
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
2 shared publications - Jian Qiu
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
2 shared publications - Kefu Liu
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
2 shared publications
Latest Publications
- 14 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1971-1980
An Electroporation-Mediated Intracellular Delivery Model With Coupled Pore Currents and Solute Transport
In the field of biomedicine, electroporation-mediated intracellular drug delivery is becoming increasingly popular due to its high efficiency and accuracy. In order to assess the therapeutic efficacy of electroporation-mediated drug delivery, accurate mathematical models are required to predict the concentration and intracellular distribution of delivery molecules. Recent research indicates that classical models, constrained by specific parameter conditions, struggle to precisely predict the distribution of target molecules within cells. Therefore, to refine the model of electroporation-mediated intracellular delivery, this paper proposes an intracellular transport equation that couples pore currents with solute transmembrane delivery. The proposed model is validated using a two-dimensional finite element model and electroporation-mediated molecular delivery experiments, where propidium iodide (PI) is utilized as the target molecule to verify the improved model. In the dynamic transport experiments of intracellular molecules, the results and simulations can be well fitted. The axial fluorescence distributions exhibited a high degree of correlation with the simulation results across various parametric conditions. The results indicate that, subsequent to the integration of solute transport with pore current, there is a significant reduction in the electrophoretic intensity of charged particles during the transmembrane process, in comparison to that observed in the classical model. This research can enhance the accuracy of predictions concerning the dynamic processes involved in intracellular molecular delivery.
- 14 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1971-1980
An Electroporation-Mediated Intracellular Delivery Model With Coupled Pore Currents and Solute Transport
In the field of biomedicine, electroporation-mediated intracellular drug delivery is becoming increasingly popular due to its high efficiency and accuracy. In order to assess the therapeutic efficacy of electroporation-mediated drug delivery, accurate mathematical models are required to predict the concentration and intracellular distribution of delivery molecules. Recent research indicates that classical models, constrained by specific parameter conditions, struggle to precisely predict the distribution of target molecules within cells. Therefore, to refine the model of electroporation-mediated intracellular delivery, this paper proposes an intracellular transport equation that couples pore currents with solute transmembrane delivery. The proposed model is validated using a two-dimensional finite element model and electroporation-mediated molecular delivery experiments, where propidium iodide (PI) is utilized as the target molecule to verify the improved model. In the dynamic transport experiments of intracellular molecules, the results and simulations can be well fitted. The axial fluorescence distributions exhibited a high degree of correlation with the simulation results across various parametric conditions. The results indicate that, subsequent to the integration of solute transport with pore current, there is a significant reduction in the electrophoretic intensity of charged particles during the transmembrane process, in comparison to that observed in the classical model. This research can enhance the accuracy of predictions concerning the dynamic processes involved in intracellular molecular delivery.
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (2) , 852-860
Modeling of Cell Electroporation With Emphasis on Ions Transport-Induced Dynamic Alterations in Membrane Conductivity
In the study of electroporation, the conductivity of the cell membrane is a crucial factor in assessing the permeability of cell membrane. In previous researches, the oversimplified equivalent resistance models were utilized to describe changes in cell membrane permeability, resulting in inaccurate results and a significant gap between experimental and simulation outcomes. In this paper, an electroporation model that incorporates a dynamic conductivity equation based on ion transmembrane transport is proposed, enabling more accurate assessments of changes in cell membrane permeability. A two-dimensional (2-D) finite-element model with coupled multi-physical field is developed to validate the proposed model. The changes in the cell conductivity is used to reveal evolutionary trends in membrane permeability. The simulation results align well with literature data and provide a mechanistic explanation for previous experimental results. Meanwhile, the effect of transmembrane transport of ions on cell membrane perforation is discussed, with results indicating that the migration of ions significantly alter the conductive properties around the cell membrane, further impacting the evolution of membrane permeability. The proposed electroporation model provides a significant improvement over previous models, allowing for more accurate predictions of cell membrane permeability. This model is of great value in the study of electroporation-mediated small molecule delivery and in developing new strategies for intracellular drug delivery.
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (2) , 852-860
Modeling of Cell Electroporation With Emphasis on Ions Transport-Induced Dynamic Alterations in Membrane Conductivity
In the study of electroporation, the conductivity of the cell membrane is a crucial factor in assessing the permeability of cell membrane. In previous researches, the oversimplified equivalent resistance models were utilized to describe changes in cell membrane permeability, resulting in inaccurate results and a significant gap between experimental and simulation outcomes. In this paper, an electroporation model that incorporates a dynamic conductivity equation based on ion transmembrane transport is proposed, enabling more accurate assessments of changes in cell membrane permeability. A two-dimensional (2-D) finite-element model with coupled multi-physical field is developed to validate the proposed model. The changes in the cell conductivity is used to reveal evolutionary trends in membrane permeability. The simulation results align well with literature data and provide a mechanistic explanation for previous experimental results. Meanwhile, the effect of transmembrane transport of ions on cell membrane perforation is discussed, with results indicating that the migration of ions significantly alter the conductive properties around the cell membrane, further impacting the evolution of membrane permeability. The proposed electroporation model provides a significant improvement over previous models, allowing for more accurate predictions of cell membrane permeability. This model is of great value in the study of electroporation-mediated small molecule delivery and in developing new strategies for intracellular drug delivery.
- Top Cited Papers
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (11) , 3625-3643
Review on Solid-State-Based Marx Generators
Marx generators are widely used to produce transient high-voltage pulses. The evolution of semiconductor devices and power electronics concepts promotes the development of solid-state Marx generators (SSMGs) and enables them with flexible pulse modulation ability. First, this article sorts out the evolution of SSMGs topologies chronologically. We can see that how the energy efficiency of SSMGs is considerably improved by replacing resistors with diodes and switches and how square-wave pulses are generated by SSMGs based on half-bridge structures. Unipolar and bipolar pulses can be easily produced with different SSMGs. Second, we discuss the influence of rated voltage and rated power of present semiconductor switches on the performances of SSMGs since switches are the key components in pulse generators. To reduce the size and weight of SSMGs, metal–oxide–semiconductor field-effect transistors (MOSFETs) and insulated gate bipolar transistors (IGBTs) with small packages are preferable. Third, synchronous isolated driving of switches as the crucial technique in SSMGs is introduced. Different methods of providing synchronous signals and isolated power to various stages in SSMGs are illustrated. Fourth, the performance including load capacity, droop compensation, waveform modulation, and self-triggering of SSMGs is discussed. In the end, the developing trend of SSMGs is given.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (11) , 3625-3643
Top Cited PapersReview on Solid-State-Based Marx Generators
Marx generators are widely used to produce transient high-voltage pulses. The evolution of semiconductor devices and power electronics concepts promotes the development of solid-state Marx generators (SSMGs) and enables them with flexible pulse modulation ability. First, this article sorts out the evolution of SSMGs topologies chronologically. We can see that how the energy efficiency of SSMGs is considerably improved by replacing resistors with diodes and switches and how square-wave pulses are generated by SSMGs based on half-bridge structures. Unipolar and bipolar pulses can be easily produced with different SSMGs. Second, we discuss the influence of rated voltage and rated power of present semiconductor switches on the performances of SSMGs since switches are the key components in pulse generators. To reduce the size and weight of SSMGs, metal–oxide–semiconductor field-effect transistors (MOSFETs) and insulated gate bipolar transistors (IGBTs) with small packages are preferable. Third, synchronous isolated driving of switches as the crucial technique in SSMGs is introduced. Different methods of providing synchronous signals and isolated power to various stages in SSMGs are illustrated. Fourth, the performance including load capacity, droop compensation, waveform modulation, and self-triggering of SSMGs is discussed. In the end, the developing trend of SSMGs is given.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (10) , 3629-3636
A High-Current All-Solid-State Pulse Generator Based on Marx Structure
In recent years, semiconductor switches have gradually replaced traditional gas switches due to their long lifetime and smaller volume. However, the rated current of the semiconductor switches limits the applications of the all-solid-state pulsed power generators. Usually, multiple semiconductor switches or pulse generators are required in parallel to share a large current in the case of the enormous power applications. In this article, a new high-current all-solid-state pulsed power generator based on Marx generators connected in parallel was proposed. One group of semiconductor switches was used to control the charging of the Marx generators. The driving circuits can be simplified due to fewer switches. It can also improve the discharge frequency and the output voltage over a capacitive load. Six 4-stage Marx generators connected in parallel have been employed to verify the proposed topologies on a capacitive and a resistive load. From the experimental results, with 1.2 kV, 150 A, and 2.4 kV, 50 A, pulses have been got on an 8-Ω resistive load and a 440-pF capacitive load, respectively. The balanced output currents can reduce the output voltage overshoot and make the system more stable and reliable.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (10) , 3629-3636
A High-Current All-Solid-State Pulse Generator Based on Marx Structure
In recent years, semiconductor switches have gradually replaced traditional gas switches due to their long lifetime and smaller volume. However, the rated current of the semiconductor switches limits the applications of the all-solid-state pulsed power generators. Usually, multiple semiconductor switches or pulse generators are required in parallel to share a large current in the case of the enormous power applications. In this article, a new high-current all-solid-state pulsed power generator based on Marx generators connected in parallel was proposed. One group of semiconductor switches was used to control the charging of the Marx generators. The driving circuits can be simplified due to fewer switches. It can also improve the discharge frequency and the output voltage over a capacitive load. Six 4-stage Marx generators connected in parallel have been employed to verify the proposed topologies on a capacitive and a resistive load. From the experimental results, with 1.2 kV, 150 A, and 2.4 kV, 50 A, pulses have been got on an 8-Ω resistive load and a 440-pF capacitive load, respectively. The balanced output currents can reduce the output voltage overshoot and make the system more stable and reliable.
- 15 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (9) , 4329-4334
Design of High-Voltage Square Pulse Generator Based on Cascade Switches and Time-Delay Driver
In the application of pulsed-power technology, capacitive loads require that high-voltage pulses have fast front and back edges. Using multiple semiconductor switches, insulated gate bipolar transistors (IGBTs) in series with discharge high-voltage capacitors can generate high-voltage pulses. By adding a group of truncation switches, square pulses with fast back edges can be obtained. A novel drive circuit using many transformers with their primary windings in series is proposed to generate two groups of reverse driving signals by changing the dotted terminals on the secondary sides. The dead time between these signals is realized by adding some time-delay circuits. In terms of drive control, both the discharging switches and the truncation switches are triggered synchronously since the primary windings of all transformers are connected in series, which ensures the synchronism of driving signals. Time-delay drive circuits are added to the secondary sides of transformers to ensure a proper dead time between the two groups of driving signals for both discharging and truncation switches. Moreover, all driving power is provided from the single driver on the primary side, greatly simplifying the drive circuit. The voltage balancing of cascade IGBTs is realized by using resistor-capacitor-diode (RCD) snubber circuits. Experiments were carried out over resistive and capacitive loads. Square pulses with a voltage amplitude of 10 kV, a pulsewidth of 8 μs, a rising time of 157 ns, and a falling time of 78 ns were obtained on a 20-kΩ resistive load. The voltage amplitude, pulsewidth, and frequency are continuously adjustable.
- 15 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (9) , 4329-4334
Design of High-Voltage Square Pulse Generator Based on Cascade Switches and Time-Delay Driver
In the application of pulsed-power technology, capacitive loads require that high-voltage pulses have fast front and back edges. Using multiple semiconductor switches, insulated gate bipolar transistors (IGBTs) in series with discharge high-voltage capacitors can generate high-voltage pulses. By adding a group of truncation switches, square pulses with fast back edges can be obtained. A novel drive circuit using many transformers with their primary windings in series is proposed to generate two groups of reverse driving signals by changing the dotted terminals on the secondary sides. The dead time between these signals is realized by adding some time-delay circuits. In terms of drive control, both the discharging switches and the truncation switches are triggered synchronously since the primary windings of all transformers are connected in series, which ensures the synchronism of driving signals. Time-delay drive circuits are added to the secondary sides of transformers to ensure a proper dead time between the two groups of driving signals for both discharging and truncation switches. Moreover, all driving power is provided from the single driver on the primary side, greatly simplifying the drive circuit. The voltage balancing of cascade IGBTs is realized by using resistor-capacitor-diode (RCD) snubber circuits. Experiments were carried out over resistive and capacitive loads. Square pulses with a voltage amplitude of 10 kV, a pulsewidth of 8 μs, a rising time of 157 ns, and a falling time of 78 ns were obtained on a 20-kΩ resistive load. The voltage amplitude, pulsewidth, and frequency are continuously adjustable.
- 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 26 (2) , 361-366
A novel drive circuit with overcurrent protection for solid state pulse generators
In recent years, semiconductor switches have been widely used in pulse generators. In order to generate bipolar or rectangular pulses, switches in these generators operate in different time sequences. However, the dv/dt induces false triggering of the semiconductor switches that leads to local short circuits. Breakdown of the load will also produce a high short-circuit current which will affect the switches' reliability and lifetime. In this paper, a new gate drive circuit is proposed to protect switches from short-circuit currents. A 52-stage solid state Marx generator using the proposed drive circuit was tested to verify the overcurrent protection. The experimental results show that the short-circuit current is limited within a safe range and the output voltage increased significantly.
- 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 26 (2) , 361-366
A novel drive circuit with overcurrent protection for solid state pulse generators
In recent years, semiconductor switches have been widely used in pulse generators. In order to generate bipolar or rectangular pulses, switches in these generators operate in different time sequences. However, the dv/dt induces false triggering of the semiconductor switches that leads to local short circuits. Breakdown of the load will also produce a high short-circuit current which will affect the switches' reliability and lifetime. In this paper, a new gate drive circuit is proposed to protect switches from short-circuit currents. A 52-stage solid state Marx generator using the proposed drive circuit was tested to verify the overcurrent protection. The experimental results show that the short-circuit current is limited within a safe range and the output voltage increased significantly.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 22, 81-84
A Novel Drive Circuit for Solid-State Rectangular Pulse Generator
Rectangular high-voltage narrow pulses are preferred in most Dielectric barrier discharge (DBD) loads and corona discharges in water. Usually at least two groups of switches are required to generate rectangular pulses over capacitive loads. One group discharge the energy-storage capacitors to the load and the other group discharges the energy stored in the parasitic capacitor of the capacitive load so as to chop off the slow tailing of pulses. Therefore, two independent drive circuits are required for these pulse generators. In this paper, a novel drive circuit combined with time-delay circuits, which can drive many different groups of switches with only one drive circuit, is propos ed. Using magnetic transformers with common primary winding, many synchronized driving signals can be generated. With some special time-delay circuits, these synchronized driving signals are modulated into many groups of different driving signals. Experiments prove that rectangular and stepped pulses can be generated using this single drive circuit.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 22, 81-84
A Novel Drive Circuit for Solid-State Rectangular Pulse Generator
Rectangular high-voltage narrow pulses are preferred in most Dielectric barrier discharge (DBD) loads and corona discharges in water. Usually at least two groups of switches are required to generate rectangular pulses over capacitive loads. One group discharge the energy-storage capacitors to the load and the other group discharges the energy stored in the parasitic capacitor of the capacitive load so as to chop off the slow tailing of pulses. Therefore, two independent drive circuits are required for these pulse generators. In this paper, a novel drive circuit combined with time-delay circuits, which can drive many different groups of switches with only one drive circuit, is propos ed. Using magnetic transformers with common primary winding, many synchronized driving signals can be generated. With some special time-delay circuits, these synchronized driving signals are modulated into many groups of different driving signals. Experiments prove that rectangular and stepped pulses can be generated using this single drive circuit.