Christina Liedert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christina Liedert has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Jussi Hiltunen
7 shared publicationsLeena Hakalahti
7 shared publications- Sanna Aikio
VTT Technical Research Centre of Finland, Oulu, Finland
4 shared publications - Jussi Hiltunen
VTT Technical Research Centre of Finland, Oulu, Finland
3 shared publications - Peter Neubauer
Chair of Bioprocess Engineering Department of Biotechnology Technische Universität Berlin Berlin Germany
3 shared publications - Ali Javey
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by Elsevier in Materials & Design
- Vol. 269
Eco-conscious scalable interconnects and embedded capacitive sensors for non-contact microfluidic monitoring
- 16 July 2026
- Published by Elsevier in Materials & Design
- Vol. 269
Open AccessEco-conscious scalable interconnects and embedded capacitive sensors for non-contact microfluidic monitoring
- Open Access
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1915-1922
Semiquantitative Lateral Flow Assay Using a Handheld Device With a Transmissive Readout
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1915-1922
Open AccessSemiquantitative Lateral Flow Assay Using a Handheld Device With a Transmissive Readout
- 29 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (7) , 2010-2017
Roll-to-Roll Manufacturing of Integrated Immunodetection Sensors
Lack of functional integration and high manufacturing costs have been identified as major challenges in commercialization of point-of-care devices. In this study, roll-to-roll (R2R) fabrication process was developed for large-scale manufacturing of disposable microfluidic devices. The integrated, user-friendly device included plasma separation membrane for simple blood filtration, immobilised antibodies for specific immunodetection, microfluidics for plasma transport and reagent mixing, and a blister for actuation and waste storage. These functionalities were designed to be compatible with R2R processing, which was demonstrated using pilot scale printing lines producing 60 devices in an hour. The produced sensors enabled rapid (10 min) and sensitive (2 µg/ml) fluorescence based immunodetection of C-reactive protein from 20 µl of whole blood.
- 29 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (7) , 2010-2017
Roll-to-Roll Manufacturing of Integrated Immunodetection Sensors
Lack of functional integration and high manufacturing costs have been identified as major challenges in commercialization of point-of-care devices. In this study, roll-to-roll (R2R) fabrication process was developed for large-scale manufacturing of disposable microfluidic devices. The integrated, user-friendly device included plasma separation membrane for simple blood filtration, immobilised antibodies for specific immunodetection, microfluidics for plasma transport and reagent mixing, and a blister for actuation and waste storage. These functionalities were designed to be compatible with R2R processing, which was demonstrated using pilot scale printing lines producing 60 devices in an hour. The produced sensors enabled rapid (10 min) and sensitive (2 µg/ml) fluorescence based immunodetection of C-reactive protein from 20 µl of whole blood.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (17) , 10275-10282
Portable Low-Cost Fluorescence Reader for LFA Measurements
A portable device for measuring fluorescence signals from a lateral flow test strip was developed. The aim was to build an easy-to-use, affordable reader device for fast, quantitative analysis of point-of-care tests, made mostly of commercial of-the-shelf components. The device is capable of exciting fluorescent labels with 532 nm and 650 nm lasers and collecting the emitted fluorescent light with a camera. Core of the device is a Raspberry Pi Zero W wireless single board computer that controls the Raspberry Pi camera v2 module and lasers. The computer can also perform the image analysis and communicate the results to a mobile phone application acting as a user interface. Sensitivity of the device was characterized by sweeping the imaging parameters and comparing the performance with a high-grade fluorescence reader. Using dummy LFA samples, it was found that the device is able to detect signals from analyte concentrations that are relevant in biological samples. Image exposure time of 500 μs was enough to read a distinguishable signal. The manufacturing costs were estimated to be below 100 euros per device in mass production.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (17) , 10275-10282
Portable Low-Cost Fluorescence Reader for LFA Measurements
A portable device for measuring fluorescence signals from a lateral flow test strip was developed. The aim was to build an easy-to-use, affordable reader device for fast, quantitative analysis of point-of-care tests, made mostly of commercial of-the-shelf components. The device is capable of exciting fluorescent labels with 532 nm and 650 nm lasers and collecting the emitted fluorescent light with a camera. Core of the device is a Raspberry Pi Zero W wireless single board computer that controls the Raspberry Pi camera v2 module and lasers. The computer can also perform the image analysis and communicate the results to a mobile phone application acting as a user interface. Sensitivity of the device was characterized by sweeping the imaging parameters and comparing the performance with a high-grade fluorescence reader. Using dummy LFA samples, it was found that the device is able to detect signals from analyte concentrations that are relevant in biological samples. Image exposure time of 500 μs was enough to read a distinguishable signal. The manufacturing costs were estimated to be below 100 euros per device in mass production.
- Top Cited PapersOpen Access
- 2 August 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (8) , eaaw9906
Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat
Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.
- 2 August 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (8) , eaaw9906
Top Cited PapersOpen AccessRegional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat
Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.
- 17 June 2019
- Published by Wiley in Advanced Functional Materials
- Vol. 29 (33)
Porous Enzymatic Membrane for Nanotextured Glucose Sweat Sensors with High Stability toward Reliable Noninvasive Health Monitoring
Development of reliable glucose sensors for noninvasive monitoring without interruption or limiting users' mobility is highly desirable, especially for diabetes diagnostics, which requires routine/long‐term monitoring. However, their applications are largely limited by the relatively poor stability. Herein, a porous membrane is synthesized for effective enzyme immobilization and it is robustly anchored to the modified nanotextured electrode solid contacts, so as to realize glucose sensors with significantly enhanced sensing stability and mechanical robustness. To the best of our knowledge, this is the first report of utilizing such nanoporous membranes for electrochemical sensor applications, which eliminates enzyme escape and provides a sufficient surface area for molecular/ion diffusion and interactions, thus ensuring the sustainable catalytic activities of the sensors and generating reliable measureable signals during noninvasive monitoring. The as‐assembled nanostructured glucose sensors demonstrate reliable long‐term stable monitoring with a minimal response drift for up to 20 h, which delivers a remarkable enhancement. Moreover, they can be integrated into a microfluidic sensing patch for noninvasive sweat glucose monitoring. The as‐synthesized nanostructured glucose sensors with remarkable stability can inspire developments of various enzymatic biosensors for reliable noninvasive composition analysis and their ultimate applications in predictive clinical diagnostics, personalized health‐care monitoring, and chronic diseases management.
- 17 June 2019
- Published by Wiley in Advanced Functional Materials
- Vol. 29 (33)
Porous Enzymatic Membrane for Nanotextured Glucose Sweat Sensors with High Stability toward Reliable Noninvasive Health Monitoring
Development of reliable glucose sensors for noninvasive monitoring without interruption or limiting users' mobility is highly desirable, especially for diabetes diagnostics, which requires routine/long‐term monitoring. However, their applications are largely limited by the relatively poor stability. Herein, a porous membrane is synthesized for effective enzyme immobilization and it is robustly anchored to the modified nanotextured electrode solid contacts, so as to realize glucose sensors with significantly enhanced sensing stability and mechanical robustness. To the best of our knowledge, this is the first report of utilizing such nanoporous membranes for electrochemical sensor applications, which eliminates enzyme escape and provides a sufficient surface area for molecular/ion diffusion and interactions, thus ensuring the sustainable catalytic activities of the sensors and generating reliable measureable signals during noninvasive monitoring. The as‐assembled nanostructured glucose sensors demonstrate reliable long‐term stable monitoring with a minimal response drift for up to 20 h, which delivers a remarkable enhancement. Moreover, they can be integrated into a microfluidic sensing patch for noninvasive sweat glucose monitoring. The as‐synthesized nanostructured glucose sensors with remarkable stability can inspire developments of various enzymatic biosensors for reliable noninvasive composition analysis and their ultimate applications in predictive clinical diagnostics, personalized health‐care monitoring, and chronic diseases management.
- 24 April 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (7) , 075333
Effect of solvent lamination on roll-to-roll hot-embossed PMMA microchannels evaluated by optical coherence tomography
- 24 April 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (7) , 075333
Effect of solvent lamination on roll-to-roll hot-embossed PMMA microchannels evaluated by optical coherence tomography
- Open Access
- 30 April 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (11) , 1552-1559
Roll-to-roll fabrication of integrated PDMS–paper microfluidics for nucleic acid amplification
High-volume roll-to-roll manufacturing of PDMS–paper microfluidics.
- 30 April 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (11) , 1552-1559
Open AccessRoll-to-roll fabrication of integrated PDMS–paper microfluidics for nucleic acid amplification
High-volume roll-to-roll manufacturing of PDMS–paper microfluidics.
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (10) , 1821-1830
A disposable, roll-to-roll hot-embossed inertial microfluidic device for size-based sorting of microbeads and cells
Inertial microfluidics has been a highly active area of research in recent years for high-throughput focusing and sorting of synthetic and biological microparticles. However, existing inertial microfluidic devices always rely on microchannels with high-aspect-ratio geometries (channel width w < channel height h) and small cross-sections (w × h < 50 × 100 μm2). Such deep and small structures increase fabrication difficulty and can limit manufacturing by large-scale and high-throughput production approaches such as roll-to-roll (R2R) hot embossing. In this work, we present a novel inertial microfluidic device using only a simple and low-aspect-ratio (LAR) straight microchannel (w > h) to achieve size-based sorting of microparticles and cells. The simple LAR geometry of the device enables successful high-throughput fabrication using R2R hot embossing. With optimized flow conditions and channel dimensions, we demonstrate continuous sorting of a mixture of 15 μm and 10 μm diameter microbeads with >97% sorting efficiency using the low-cost and disposable R2R chip. We further demonstrate size-based sorting of bovine white blood cells, demonstrating the ability to process real cellular samples in our R2R chip. We envision that this R2R hot-embossed inertial microfluidic chip will serve as a powerful yet low-cost and disposable tool for size-based sorting of synthetic microparticles in industrial applications or cellular samples in cell biology research and clinical diagnostics.
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (10) , 1821-1830
A disposable, roll-to-roll hot-embossed inertial microfluidic device for size-based sorting of microbeads and cells
Inertial microfluidics has been a highly active area of research in recent years for high-throughput focusing and sorting of synthetic and biological microparticles. However, existing inertial microfluidic devices always rely on microchannels with high-aspect-ratio geometries (channel width w < channel height h) and small cross-sections (w × h < 50 × 100 μm2). Such deep and small structures increase fabrication difficulty and can limit manufacturing by large-scale and high-throughput production approaches such as roll-to-roll (R2R) hot embossing. In this work, we present a novel inertial microfluidic device using only a simple and low-aspect-ratio (LAR) straight microchannel (w > h) to achieve size-based sorting of microparticles and cells. The simple LAR geometry of the device enables successful high-throughput fabrication using R2R hot embossing. With optimized flow conditions and channel dimensions, we demonstrate continuous sorting of a mixture of 15 μm and 10 μm diameter microbeads with >97% sorting efficiency using the low-cost and disposable R2R chip. We further demonstrate size-based sorting of bovine white blood cells, demonstrating the ability to process real cellular samples in our R2R chip. We envision that this R2R hot-embossed inertial microfluidic chip will serve as a powerful yet low-cost and disposable tool for size-based sorting of synthetic microparticles in industrial applications or cellular samples in cell biology research and clinical diagnostics.
- Open Access
- 18 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e68918
Patterned Immobilization of Antibodies within Roll-to-Roll Hot Embossed Polymeric Microfluidic Channels
This paper describes a method for the patterned immobilization of capture antibodies into a microfluidic platform fabricated by roll-to-roll (R2R) hot embossing on poly (methyl methacrylate) (PMMA). Covalent attachment of antibodies was achieved by two sequential inkjet printing steps. First, a polyethyleneimine (PEI) layer was deposited onto oxygen plasma activated PMMA foil and further cross-linked with glutaraldehyde (GA) to provide an amine-reactive aldehyde surface (PEI-GA). This step was followed by a second deposition of antibody by overprinting on the PEI-GA patterned PMMA foil. The PEI polymer ink was first formulated to ensure stable drop formation in inkjet printing and the printed films were characterized using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). Anti-CRP antibody was patterned on PMMA foil by the developed method and bonded permanently with R2R hot embossed PMMA microchannels by solvent bonding lamination. The functionality of the immobilized antibody inside the microfluidic channel was evaluated by fluorescence-based sandwich immunoassay for detection of C-reactive protein (CRP). The antibody-antigen assay exhibited a good level of linearity over the range of 10 ng/ml to 500 ng/ml (R2 = 0.991) with a calculated detection limit of 5.2 ng/ml. The developed patterning method is straightforward, rapid and provides a versatile approach for creating multiple protein patterns in a single microfluidic channel for multiplexed immunoassays.
- 18 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e68918
Open AccessPatterned Immobilization of Antibodies within Roll-to-Roll Hot Embossed Polymeric Microfluidic Channels
This paper describes a method for the patterned immobilization of capture antibodies into a microfluidic platform fabricated by roll-to-roll (R2R) hot embossing on poly (methyl methacrylate) (PMMA). Covalent attachment of antibodies was achieved by two sequential inkjet printing steps. First, a polyethyleneimine (PEI) layer was deposited onto oxygen plasma activated PMMA foil and further cross-linked with glutaraldehyde (GA) to provide an amine-reactive aldehyde surface (PEI-GA). This step was followed by a second deposition of antibody by overprinting on the PEI-GA patterned PMMA foil. The PEI polymer ink was first formulated to ensure stable drop formation in inkjet printing and the printed films were characterized using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). Anti-CRP antibody was patterned on PMMA foil by the developed method and bonded permanently with R2R hot embossed PMMA microchannels by solvent bonding lamination. The functionality of the immobilized antibody inside the microfluidic channel was evaluated by fluorescence-based sandwich immunoassay for detection of C-reactive protein (CRP). The antibody-antigen assay exhibited a good level of linearity over the range of 10 ng/ml to 500 ng/ml (R2 = 0.991) with a calculated detection limit of 5.2 ng/ml. The developed patterning method is straightforward, rapid and provides a versatile approach for creating multiple protein patterns in a single microfluidic channel for multiplexed immunoassays.