Michael Gembicki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Gembicki has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jan Weichert
University Hospital of Schleswig-Holstein
6 shared publications - Jann Lennard Scharf
Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University of Luebeck, University Hospital Schleswig-Holstein, Luebeck, Germany
5 shared publications - Christoph Dracopoulos
Department of Gynecology & Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
4 shared publications Jan Weichert
Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
4 shared publications- Amrei Welp
Department of Gynecology & Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
3 shared publications Christoph Dracopoulos
Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
2 shared publications
Latest Publications
- Open Access
- 5 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6371
Semi-Automatic Measurement of Fetal Cardiac Axis in Fetuses with Congenital Heart Disease (CHD) with Fetal Intelligent Navigation Echocardiography (FINE)
Congenital heart disease (CHD) is one of the most common organ-specific birth defects and a major cause of infant morbidity and mortality. Despite ultrasound screening guidelines, the detection rate of CHD is limited. Fetal intelligent navigation echocardiography (FINE) has been introduced to extract reference planes and cardiac axis from cardiac spatiotemporal image correlation (STIC) volume datasets. This study analyses the cardiac axis in fetuses affected by CHD/thoracic masses (n = 545) compared to healthy fetuses (n = 1543) generated by FINE. After marking seven anatomical structures, the FINE software generated semi-automatically nine echocardiography standard planes and calculated the cardiac axis. Our study reveals that depending on the type of CHD, the cardiac axis varies. In approximately 86% (471 of 542 volumes) of our pathological cases, an abnormal cardiac axis (normal median = 40–45°) was detectable. Significant differences between the fetal axis of the normal heart versus CHD were detected in HLHS, pulmonary atresia, TOF (p-value < 0.0001), RAA, situs ambiguus (p-value = 0.0001–0.001) and absent pulmonary valve syndrome, DORV, thoracic masses (p-value = 0.001–0.01). This analysis confirms that in fetuses with CHD, the cardiac axis can significantly deviate from the normal range. FINE appears to be a valuable tool to identify cardiac defects.
- 5 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6371
Open AccessSemi-Automatic Measurement of Fetal Cardiac Axis in Fetuses with Congenital Heart Disease (CHD) with Fetal Intelligent Navigation Echocardiography (FINE)
Congenital heart disease (CHD) is one of the most common organ-specific birth defects and a major cause of infant morbidity and mortality. Despite ultrasound screening guidelines, the detection rate of CHD is limited. Fetal intelligent navigation echocardiography (FINE) has been introduced to extract reference planes and cardiac axis from cardiac spatiotemporal image correlation (STIC) volume datasets. This study analyses the cardiac axis in fetuses affected by CHD/thoracic masses (n = 545) compared to healthy fetuses (n = 1543) generated by FINE. After marking seven anatomical structures, the FINE software generated semi-automatically nine echocardiography standard planes and calculated the cardiac axis. Our study reveals that depending on the type of CHD, the cardiac axis varies. In approximately 86% (471 of 542 volumes) of our pathological cases, an abnormal cardiac axis (normal median = 40–45°) was detectable. Significant differences between the fetal axis of the normal heart versus CHD were detected in HLHS, pulmonary atresia, TOF (p-value < 0.0001), RAA, situs ambiguus (p-value = 0.0001–0.001) and absent pulmonary valve syndrome, DORV, thoracic masses (p-value = 0.001–0.01). This analysis confirms that in fetuses with CHD, the cardiac axis can significantly deviate from the normal range. FINE appears to be a valuable tool to identify cardiac defects.
- Open Access
- 16 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5334
A Clinical Approach to Semiautomated Three-Dimensional Fetal Brain Biometry—Comparing the Strengths and Weaknesses of Two Diagnostic Tools: 5DCNS+TM and SonoCNSTM
(1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.
- 16 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5334
Open AccessA Clinical Approach to Semiautomated Three-Dimensional Fetal Brain Biometry—Comparing the Strengths and Weaknesses of Two Diagnostic Tools: 5DCNS+TM and SonoCNSTM
(1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.
- Open Access
- 11 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1705
How Automated Techniques Ease Functional Assessment of the Fetal Heart: Applicability of MPI+™ for Direct Quantification of the Modified Myocardial Performance Index
(1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle’s in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from −0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.
- 11 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1705
Open AccessHow Automated Techniques Ease Functional Assessment of the Fetal Heart: Applicability of MPI+™ for Direct Quantification of the Modified Myocardial Performance Index
(1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle’s in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from −0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.
- Open Access
- 24 April 2023
- Published by Springer Nature in Cureus
- Vol. 15 (4) , e38052
Application of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) in Twin Pregnancies: Half the Work or Twice the Effort?
Objective: To assess the performance of fetal intelligent navigation echocardiography (FINE, 5D Heart™) for automated volumetric investigation of the fetal heart in twin pregnancies. Methods: Three hundred twenty-eight twin fetuses underwent fetal echocardiography in the second and third trimesters. Spatiotemporal image correlation (STIC) volumes were obtained for a volumetric investigation. The volumes were analyzed using the FINE software, and the data were investigated regarding image quality and many properly reconstructed planes. Results: Three hundred and eight volumes underwent final analysis. 55.8% of the included pregnancies were dichorionic twin pregnancies, and 44.2% were monochorionic twin pregnancies. The mean gestational age (GA) was 22.1 weeks, and the mean maternal BMI was 27.3 kg/m2. The STIC-volume acquisition was successful in 100.0% and 95.5% of cases. The overall depiction rates of FINE were 96.5% (twin 1) and 94.7% (twin 2), respectively (p = 0.0849, not significant). In 95.9% (twin 1) and 93.9% (twin 2), at least 7 planes were reconstructed properly (p = 0.6056, not significant). Conclusion: Our results indicate that the FINE technique used in twin pregnancies is reliable. No significant difference between the depiction rates of twin 1 and twin 2 could be detected. In addition, the depiction rates are as high as those derived from singleton pregnancies. Due to the challenges of fetal echocardiography in twin pregnancies (i.e., greater rates of cardiac anomaly and more difficult scans), the FINE technique might be a valuable tool to improve the quality of medical care in those pregnancies.
- 24 April 2023
- Published by Springer Nature in Cureus
- Vol. 15 (4) , e38052
Open AccessApplication of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) in Twin Pregnancies: Half the Work or Twice the Effort?
Objective: To assess the performance of fetal intelligent navigation echocardiography (FINE, 5D Heart™) for automated volumetric investigation of the fetal heart in twin pregnancies. Methods: Three hundred twenty-eight twin fetuses underwent fetal echocardiography in the second and third trimesters. Spatiotemporal image correlation (STIC) volumes were obtained for a volumetric investigation. The volumes were analyzed using the FINE software, and the data were investigated regarding image quality and many properly reconstructed planes. Results: Three hundred and eight volumes underwent final analysis. 55.8% of the included pregnancies were dichorionic twin pregnancies, and 44.2% were monochorionic twin pregnancies. The mean gestational age (GA) was 22.1 weeks, and the mean maternal BMI was 27.3 kg/m2. The STIC-volume acquisition was successful in 100.0% and 95.5% of cases. The overall depiction rates of FINE were 96.5% (twin 1) and 94.7% (twin 2), respectively (p = 0.0849, not significant). In 95.9% (twin 1) and 93.9% (twin 2), at least 7 planes were reconstructed properly (p = 0.6056, not significant). Conclusion: Our results indicate that the FINE technique used in twin pregnancies is reliable. No significant difference between the depiction rates of twin 1 and twin 2 could be detected. In addition, the depiction rates are as high as those derived from singleton pregnancies. Due to the challenges of fetal echocardiography in twin pregnancies (i.e., greater rates of cardiac anomaly and more difficult scans), the FINE technique might be a valuable tool to improve the quality of medical care in those pregnancies.
- Open Access
- 18 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2609-2617
Vascular Choroidal Alterations in Uncomplicated Third-Trimester Pregnancy
(1) Purpose: To evaluate the anatomy and perfusion of choroidal substructures in third-trimester pregnant women using optical coherence tomography (OCT) and OCT angiography (OCTA) imaging. (2) Methods: In this cross-sectional study, women in their third trimester of uncomplicated pregnancy and non-pregnant age-matched women were recruited. Participants underwent enhanced depth imaging (EDI) OCT and OCTA. Subfoveal choroidal thickness (SFCT), as well as choroidal sublayer perfusion, were compared between groups. (3) Results: In total, 26 eyes of 26 pregnant and 26 eyes of 26 non-pregnant women were included. The median age in both groups was 29 years. The median SFCT was 332 (211–469) µm in the pregnant group and 371.5 (224–466) µm in the non-pregnant cohort (p = 0.018). The median choriocapillaris perfusion (CCP) was significantly lower in the pregnant group (46% vs. 48%, p = 0.039). Moreover, Haller’s layer perfusion correlated significantly with mean arterial pressure in non-pregnant women (CC = 0.430, p = 0.028) but not in pregnant ones (CC = 0.054, p = 0.792). (4) Conclusions: SFCT was found to be thinner and CCP was lower in third-trimester pregnant women. Hormonal changes during pregnancy and consecutive impacts on autoregulation of small choroidal vessels might play an important role. Therefore, altered choroidal measurements during third-trimester pregnancy should be carefully evaluated as, to some extent, it could be a normal physiological change.
- 18 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2609-2617
Open AccessVascular Choroidal Alterations in Uncomplicated Third-Trimester Pregnancy
(1) Purpose: To evaluate the anatomy and perfusion of choroidal substructures in third-trimester pregnant women using optical coherence tomography (OCT) and OCT angiography (OCTA) imaging. (2) Methods: In this cross-sectional study, women in their third trimester of uncomplicated pregnancy and non-pregnant age-matched women were recruited. Participants underwent enhanced depth imaging (EDI) OCT and OCTA. Subfoveal choroidal thickness (SFCT), as well as choroidal sublayer perfusion, were compared between groups. (3) Results: In total, 26 eyes of 26 pregnant and 26 eyes of 26 non-pregnant women were included. The median age in both groups was 29 years. The median SFCT was 332 (211–469) µm in the pregnant group and 371.5 (224–466) µm in the non-pregnant cohort (p = 0.018). The median choriocapillaris perfusion (CCP) was significantly lower in the pregnant group (46% vs. 48%, p = 0.039). Moreover, Haller’s layer perfusion correlated significantly with mean arterial pressure in non-pregnant women (CC = 0.430, p = 0.028) but not in pregnant ones (CC = 0.054, p = 0.792). (4) Conclusions: SFCT was found to be thinner and CCP was lower in third-trimester pregnant women. Hormonal changes during pregnancy and consecutive impacts on autoregulation of small choroidal vessels might play an important role. Therefore, altered choroidal measurements during third-trimester pregnancy should be carefully evaluated as, to some extent, it could be a normal physiological change.
- 30 September 2022
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 82 (10) , e180
Multiple Fehlbildungen eines männlichen Feten – phenotypische Überlappung von VACTERL-H und Fanconi Anämie Typ B: Ein Fallbericht
Zusammenfassung Bei x-chromosomal vererbter Fanconi-Anämie zeigen etwa 5% der männlichen Feten zusätzlich multiple Fehlbildungen entsprechend der VACTERL oder VACTERL-H Assoziation, die das peripartale Überleben gefährden und das langfristige Outcome negativ beeinflussen kann. Da diese Neugeborenen postpartal eine unmittelbare, oftmals auch intensivmedizinische Versorgung benötigen, ist eine exakte pränatale Detektion essenziell, um ein initiales Überleben zu gewährleisten und die langfristige Prognose zu verbessern. Dieser Fall präsentiert in diesem Zusammenhang die unterschätzte Notwendigkeit einer umfassenden genetischen Diagnostik, insbesondere bei männlichen Feten mit der Verdachtsdiagnose VACTERL-H, da eine frühzeitige Diagnose hier die Therapie der, mit der Erkrankung assoziierten Tumore und die der Knochenmarksinsuffizienz erleichtern kann. Anamnese und klinischer Befund Wir berichten von einem männlichen Fetus mit auffälligem Ultraschall im Rahmen des Zweittrimesterscreenings in der 22. SSW. Es kamen eine bilaterale Ventrikulomegalie, ein hypoplastisches Corpus callosum, ebenso wie Hinweiszeichen für eine Doudenalatresie zur Darstellung, daneben wurde der Verdacht auf eine rechtsseitige Nierenaplasie gestellt. Zusätzlich zeigten sich eine singuläre Nabelschnurarterie und Thenaraplasie. Eine konventionelle Karyotypisierung zeigte einen Normalbefund. Die postpartal veranlasste Trioexomesequenzierung ergab den molekulargenetischen Nachweis einer Fanconi-Anämie. Eine hemizygote Deletion im Promotorbereich des FANB Gens wurde nachgewiesen und als krankheitsursächlich erachtet. Diagnose VACTERL-H Assoziation und Faconi-Anämie basierend auf einer hemizygoten Deletion des FANB Gens. Therapie und Verlauf Das männliche Neugeborene wurde per Sectio entbunden und aufgrund der mutliplen Fehlbildung im Verlauf mehrfach operiert. Es wurde im Faconi-B Register gelistet und verstarb im Alter von elf Monaten an schwerem Leberversagen. Article published online: 11 October 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- 30 September 2022
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 82 (10) , e180
Multiple Fehlbildungen eines männlichen Feten – phenotypische Überlappung von VACTERL-H und Fanconi Anämie Typ B: Ein Fallbericht
Zusammenfassung Bei x-chromosomal vererbter Fanconi-Anämie zeigen etwa 5% der männlichen Feten zusätzlich multiple Fehlbildungen entsprechend der VACTERL oder VACTERL-H Assoziation, die das peripartale Überleben gefährden und das langfristige Outcome negativ beeinflussen kann. Da diese Neugeborenen postpartal eine unmittelbare, oftmals auch intensivmedizinische Versorgung benötigen, ist eine exakte pränatale Detektion essenziell, um ein initiales Überleben zu gewährleisten und die langfristige Prognose zu verbessern. Dieser Fall präsentiert in diesem Zusammenhang die unterschätzte Notwendigkeit einer umfassenden genetischen Diagnostik, insbesondere bei männlichen Feten mit der Verdachtsdiagnose VACTERL-H, da eine frühzeitige Diagnose hier die Therapie der, mit der Erkrankung assoziierten Tumore und die der Knochenmarksinsuffizienz erleichtern kann. Anamnese und klinischer Befund Wir berichten von einem männlichen Fetus mit auffälligem Ultraschall im Rahmen des Zweittrimesterscreenings in der 22. SSW. Es kamen eine bilaterale Ventrikulomegalie, ein hypoplastisches Corpus callosum, ebenso wie Hinweiszeichen für eine Doudenalatresie zur Darstellung, daneben wurde der Verdacht auf eine rechtsseitige Nierenaplasie gestellt. Zusätzlich zeigten sich eine singuläre Nabelschnurarterie und Thenaraplasie. Eine konventionelle Karyotypisierung zeigte einen Normalbefund. Die postpartal veranlasste Trioexomesequenzierung ergab den molekulargenetischen Nachweis einer Fanconi-Anämie. Eine hemizygote Deletion im Promotorbereich des FANB Gens wurde nachgewiesen und als krankheitsursächlich erachtet. Diagnose VACTERL-H Assoziation und Faconi-Anämie basierend auf einer hemizygoten Deletion des FANB Gens. Therapie und Verlauf Das männliche Neugeborene wurde per Sectio entbunden und aufgrund der mutliplen Fehlbildung im Verlauf mehrfach operiert. Es wurde im Faconi-B Register gelistet und verstarb im Alter von elf Monaten an schwerem Leberversagen. Article published online: 11 October 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 14 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4062
Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
(1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and third trimester fetuses were examined by targeted ultrasound. Spatiotemporal image correlation (STIC) volumes of the fetal heart were acquired for further volumetric assessment. In addition, all fetal hearts were scanned by a fast acquisition time volume (1 s). The volumes were analyzed using the FINE software. The data were investigated regarding the number of properly reconstructed planes and cardiac axis. (3) Results: A total of 257 volumes were included for final analysis. The mean gestational age (GA) was 23.9 weeks (14.3 to 37.7 weeks). In 96.9 (standard acquisition time, FINE standard mode) and 94.2% (fast acquisition time, FINE static mode) at least seven planes were reconstructed properly (p = 0.0961, not significant). Regarding the overall depiction rate, the standard mode was able to reconstruct 96.9% of the planes properly, whereas the static mode showed 95.2% of the planes (p = 0.0098). Moreover, there was no significant difference between the automatic measurement of the cardiac axis (37.95 + 9.14 vs. 38.00 + 8.92 degrees, p = 0.8827, not significant). (4) Conclusions: Based on our results, the FINE static mode technique is a reliable method. It provides similar information of the cardiac anatomy compared to conventional STIC volumes assessed by the FINE method. The FINE static mode has the potential to minimize the influence of motion artifacts during volume acquisition and might therefore be helpful concerning volumetric cardiac assessment in daily routine.
- 14 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4062
Open AccessMaximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
(1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and third trimester fetuses were examined by targeted ultrasound. Spatiotemporal image correlation (STIC) volumes of the fetal heart were acquired for further volumetric assessment. In addition, all fetal hearts were scanned by a fast acquisition time volume (1 s). The volumes were analyzed using the FINE software. The data were investigated regarding the number of properly reconstructed planes and cardiac axis. (3) Results: A total of 257 volumes were included for final analysis. The mean gestational age (GA) was 23.9 weeks (14.3 to 37.7 weeks). In 96.9 (standard acquisition time, FINE standard mode) and 94.2% (fast acquisition time, FINE static mode) at least seven planes were reconstructed properly (p = 0.0961, not significant). Regarding the overall depiction rate, the standard mode was able to reconstruct 96.9% of the planes properly, whereas the static mode showed 95.2% of the planes (p = 0.0098). Moreover, there was no significant difference between the automatic measurement of the cardiac axis (37.95 + 9.14 vs. 38.00 + 8.92 degrees, p = 0.8827, not significant). (4) Conclusions: Based on our results, the FINE static mode technique is a reliable method. It provides similar information of the cardiac anatomy compared to conventional STIC volumes assessed by the FINE method. The FINE static mode has the potential to minimize the influence of motion artifacts during volume acquisition and might therefore be helpful concerning volumetric cardiac assessment in daily routine.
- Open Access
- 2 May 2022
- Published by Springer Nature in Die Gynäkologie
- Vol. 55 (6) , 447-454
Stimmungsbild des ärztlichen Nachwuchses in der Frauenheilkunde und Geburtshilfe in Norddeutschland
Zusammenfassung: Hintergrund: Der ärztliche Nachwuchs hat disruptive Effekte und macht auch vor dem Fach Frauenheilkunde und Geburtshilfe nicht halt. Noch fokussiert sich der Diskurs auf die Generation Y (1980–1994). Um dem Nachwuchs ein konstruktives Arbeitsumfeld zu bieten, drängt die Zeit. Es gilt, sich dessen Anforderungen an ein solches zu vergegenwärtigen. Zielsetzung: Erfassen des Stimmungsbilds des ärztlichen Nachwuchses in der Frauenheilkunde und Geburtshilfe mit anschließender Ableitung praxisrelevanter Aspekte unter Berücksichtigung der künftig dominierenden Generation Z (1995–2009). Methoden: Von Januar bis Oktober 2021 wurde eine deskriptive Querschnittserhebung des ärztlichen Nachwuchses ausbildender Kliniken im Fach Frauenheilkunde und Geburtshilfe durchgeführt. Es wurden 81 Fragen zu 6 Themen online abgefragt. Ergebnis: Ausgewertet wurden 122 Fragebögen (n = 122): 28 % (n = 33) schätzen die Arbeitsbelastung als sehr hoch, 56 % (n = 67) als hoch ein. Zwei Drittel (n = 81) arbeiten wöchentlich 40–59 h. Den Anteil delegierbarer Tätigkeiten beziffern 67 % (n = 80) auf > 25 %. 88 % (n = 105) verbringen 25–75 % der täglichen Arbeitszeit mit Dokumentieren. 92 % (n = 109) wünschen sich regelmäßige Ober- bzw. Chefarztvisiten, 81 % (n = 95) beurteilen die Weiterbildung schlechter als gut. Für 32 % (n = 38) besteht ein ausgeglichenes Verhältnis zwischen Gesundheit und Beruf, 25 % (n = 29) beurteilen die Arbeitsbedingungen als familienfreundlich, und 88 % (n = 102) wären bereit, bei anhaltender Unzufriedenheit den Arbeitgeber zu wechseln. Schlussfolgerung: Den Nachwuchs dominieren Forderungen nach Weiterbildung, Teilzeit, Sinnhaftigkeit, Vereinbarkeit von Familie und Beruf, Wertschätzung und Selbstfürsorge. Lösungskonzepte, um diesen gerecht zu werden, stünden zur Verfügung.
- 2 May 2022
- Published by Springer Nature in Die Gynäkologie
- Vol. 55 (6) , 447-454
Open AccessStimmungsbild des ärztlichen Nachwuchses in der Frauenheilkunde und Geburtshilfe in Norddeutschland
Zusammenfassung: Hintergrund: Der ärztliche Nachwuchs hat disruptive Effekte und macht auch vor dem Fach Frauenheilkunde und Geburtshilfe nicht halt. Noch fokussiert sich der Diskurs auf die Generation Y (1980–1994). Um dem Nachwuchs ein konstruktives Arbeitsumfeld zu bieten, drängt die Zeit. Es gilt, sich dessen Anforderungen an ein solches zu vergegenwärtigen. Zielsetzung: Erfassen des Stimmungsbilds des ärztlichen Nachwuchses in der Frauenheilkunde und Geburtshilfe mit anschließender Ableitung praxisrelevanter Aspekte unter Berücksichtigung der künftig dominierenden Generation Z (1995–2009). Methoden: Von Januar bis Oktober 2021 wurde eine deskriptive Querschnittserhebung des ärztlichen Nachwuchses ausbildender Kliniken im Fach Frauenheilkunde und Geburtshilfe durchgeführt. Es wurden 81 Fragen zu 6 Themen online abgefragt. Ergebnis: Ausgewertet wurden 122 Fragebögen (n = 122): 28 % (n = 33) schätzen die Arbeitsbelastung als sehr hoch, 56 % (n = 67) als hoch ein. Zwei Drittel (n = 81) arbeiten wöchentlich 40–59 h. Den Anteil delegierbarer Tätigkeiten beziffern 67 % (n = 80) auf > 25 %. 88 % (n = 105) verbringen 25–75 % der täglichen Arbeitszeit mit Dokumentieren. 92 % (n = 109) wünschen sich regelmäßige Ober- bzw. Chefarztvisiten, 81 % (n = 95) beurteilen die Weiterbildung schlechter als gut. Für 32 % (n = 38) besteht ein ausgeglichenes Verhältnis zwischen Gesundheit und Beruf, 25 % (n = 29) beurteilen die Arbeitsbedingungen als familienfreundlich, und 88 % (n = 102) wären bereit, bei anhaltender Unzufriedenheit den Arbeitgeber zu wechseln. Schlussfolgerung: Den Nachwuchs dominieren Forderungen nach Weiterbildung, Teilzeit, Sinnhaftigkeit, Vereinbarkeit von Familie und Beruf, Wertschätzung und Selbstfürsorge. Lösungskonzepte, um diesen gerecht zu werden, stünden zur Verfügung.
- Open Access
- 14 October 2021
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 58 (S1) , 300
VP47.04: Comparison of two semiautomated volume approaches in clinical use: can coronal and sagittal planes provide a diagnostic benefit?
- 14 October 2021
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 58 (S1) , 300
Open AccessVP47.04: Comparison of two semiautomated volume approaches in clinical use: can coronal and sagittal planes provide a diagnostic benefit?
- Open Access
- 8 April 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (2) , 355-364
Semiautomatic Assessment of Fetal Fractional Limb Volume for Weight Prediction in Clinical Praxis
Objectives: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model.Methods: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated.Results: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (−0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (−2.63 ± 7.69% and −3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns).Conclusions: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third‐trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.
- 8 April 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (2) , 355-364
Open AccessSemiautomatic Assessment of Fetal Fractional Limb Volume for Weight Prediction in Clinical Praxis
Objectives: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model.Methods: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated.Results: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (−0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (−2.63 ± 7.69% and −3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns).Conclusions: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third‐trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.