QLQingyue Li

Qingyue Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qingyue Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Duration of High-Fidelity Simulator Training for Bronchoscope-Guided Intubation

    by Luyang Jiang, Qingmei Bsc Yang, Qingyue Li, Bailin Jiang, Ciren Bsc Laba, Yi Feng

    Introduction: The optimal simulator training duration for flexible optical bronchoscopic (FOB) intubation is unknown. This study aimed to determine whether a learning curve-based training modality was noninferior to a fixed training time modality in terms of clinical FOB intubation time. Methods: This multicenter, randomized, noninferiority study was conducted from May to August 2022. Anesthesiology residents or interns were enrolled. Eligible participants were randomized in a 1:1 ratio to receive new learning curve-based simulator training (individualized training time based on performance, group New) or reference fixed training time simulator training (1 hour, group Reference). The primary outcome was the time to complete FOB intubation in patients, which was defined as the time from the introduction of the FOB into the mouth until the first capnography visualization. The margin for detecting clinical significance was defined as 10 seconds. Results: A total of 32 participants were included in the analysis (16 in each group). All trainees successfully intubated the patients. The mean intubation time (95% confidence interval [CI]) was 81.9 (65.7–98.1) seconds in group New and 97.0 (77.4–116.6) seconds in group Reference. The upper bound of the 1-sided 97.5% CI for the mean difference of clinical intubation time between groups was 9.3 seconds. Noninferiority was claimed. The mean duration of the training in group New was 28.4 (95% CI, 23.5–33.4) minutes. The total number of training procedures on simulators in group New was significantly less than that in group Reference (P < 0.01). Conclusions: The clinical FOB intubation time in group New was noninferior to that in group Reference.

  • Open Access

    Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial

    by Hansheng Liang, Yuantao Hou, Liang Sun, Qingyue Li, Huafeng Wei, Yi Feng

    Supraglottic jet oxygenation and ventilation (SJOV) can effectively maintain adequate oxygenation in patients with respiratory depression, even in apnea patients. However, there have been no randomized controlled clinical trials of SJOV in obese patients. This study investigated the efficacy and safety of SJOV using WEI Nasal Jet tube (WNJ) for obese patients who underwent hysteroscopy under intravenous anesthesia without endotracheal intubation. A single-center, prospective, randomized controlled study was conducted. The obese patients receiving hysteroscopy under intravenous anesthesia were randomly divided into three groups: Control group maintaining oxygen supply via face masks (100% oxygen, flow at 6 L/min), the WNJ Oxygen Group with WNJ (100% oxygen, flow: 6 L/min) and the WNJ SJOV Group with SJOV via WNJ [Jet ventilator working parameters:100% oxygen supply, driving pressure (DP) 0.1 MPa, respiratory rate; (RR): 15 bpm, I/E; ratio 1:1.5]. SpO2, PETCO2, BP, HR, ECG and BIS were continuously monitored during anesthesia. Two-Diameter Method was deployed to measure cross sectional area of the gastric antrum (CSA-GA) by ultrasound before and after SJOV in the WNJ SJOV Group. Episodes of SpO2 less than 95%, PETCO2 less than 10 mmHg, depth of WNJ placement and measured CSA-GA before and after jet ventilation in the WNJ SJOV Group during the operation were recorded. The other adverse events were collected as well. A total of 102 patients were enrolled, with two patients excluded. Demographic characteristics were similar among the three groups. Compared with the Control Group, the incidence of PETCO2 < 10 mmHg, SpO2 < 95% in the WNJ SJOV group dropped from 36 to 9% (P = 0.009),from 33 to 6% (P = 0.006) respectively,and the application rate of jaw-lift decreased from 33 to 3% (P = 0.001), and the total percentage of adverse events decreased from 36 to 12% (P = 0.004). Compared with the WNJ Oxygen Group, the use of SJOV via WNJ significantly decreased episodes of SpO2 < 95% from 27 to 6% (P = 0.023), PETCO2 < 10 mmHg from 33 to 9% (P = 0.017), respectively. Depth of WNJ placement was about 12.34 cm in WNJ SJOV Group. There was no significantly difference of CSA-GA before and after SJOV in the WNJ SJOV Group (P = 0.234). There were no obvious cases of nasal bleeding in all the three groups. SJOV can effectively and safely maintain adequate oxygenation in obese patients under intravenous anesthesia without intubation during hysteroscopy. This efficient oxygenation may be mainly attributed to supplies of high concentration oxygenation to the supraglottic area, and the high pressure jet pulse providing effective ventilation. Although the nasal airway tube supporting collapsed airway by WNJ also plays a role. SJOV doesn’t seem to increase gastric distension and the risk of aspiration. SJOV can improve the safety of surgery by reducing the incidence of the intraoperative involuntary limbs swing, hip twist and cough. Chinese Clinical Trial Registry. Registration number, ChiCTR1800017028, registered on July 9, 2018.