Xinyi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xinyi Li has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Yang Sheng
Medical Physics Graduate Program, Duke University, Department of Radiation Oncology Box 3085 Duke Cancer Center, Medicine Circle, Durham, Durham, North Carolina, 27710, UNITED STATES
6 shared publicationsQ Jackie Wu
Department of Radiation Oncology, Duke University Medical Center, PO Box 3085, Durham, NC 27710, USA, durhan, North Carolina, 27719, UNITED STATES
5 shared publications- Dongrong Yang
Duke University, 20 Duke Medicine Cir, Durham, 27708-0187, UNITED STATES
3 shared publications - Qiuwen Wu
Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
3 shared publications Yaorong Ge
Department of Information Systems University of North Carolina at Charlotte Charlotte North Carolina United States
3 shared publicationsChunhao Wang
Duke University Medical Center
2 shared publications
Latest Publications
- 20 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085019
Reinforcement learning-driven automated head and neck simultaneous integrated boost (SIB) radiation therapy: flexible treatment planning aligned with clinical preferences
Objective. Head-and-neck simultaneous integrated boost (SIB) treatment planning using intensity modulated radiation therapy is particularly challenging due to the proximity to organs-at-risk. Depending on the specific clinical conditions, different parotid-sparing strategies are utilized to preserve parotid function without compromising local tumor control. Clinically this is typically done with attending’s directive or via trial-and-error comparison with different sparing tradeoffs. To streamline this process, we proposed a deep reinforcement learning (DRL)-based framework that automatically generates treatment plans with flexibility to adapt to clinical preferences. Approach. A preference-encoded DRL (PEDRL) framework was developed to self-interact with the clinical treatment planning system and dynamically adjust objective constraints in the inverse optimization space. It was powered by the discrete soft actor-critic algorithm with a multi-layer perceptron architecture. The agent interprets intermediate plan status and iteratively modifies objective constraint values in a human-like fashion. By encoding parotid-sparing preferences within the state space, the agent autonomously adapts the sparing strategy to achieve optimal plan quality based on clinical priorities. The agent was trained through iterative treatment plan generation using 40 cases and subsequently tested on additional 44 patients, with generated plans compared to clinical plans. Main results. The PEDRL-generated plans demonstrated comparable performance across all dosimetric evaluation metrics for both bilateral and unilateral sparing cases in the test set. For bilateral cases, the mean value of the parotid median dose was 18.82 Gy (left) and 19.61 Gy (right), compared to 19.31 Gy (left) and 19.12 Gy (right) in the clinical plans. In unilateral sparing cases, the mean value of the spared parotid median dose was 19.92 Gy in the PEDRL-generated plans, compared to 17.16 Gy in the clinical plans. Significance. The proposed novel automated treatment planning framework efficiently generates SIB treatment plans tailored to clinical preferences, demonstrating both effectiveness and adaptability.
- 20 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085019
Reinforcement learning-driven automated head and neck simultaneous integrated boost (SIB) radiation therapy: flexible treatment planning aligned with clinical preferences
Objective. Head-and-neck simultaneous integrated boost (SIB) treatment planning using intensity modulated radiation therapy is particularly challenging due to the proximity to organs-at-risk. Depending on the specific clinical conditions, different parotid-sparing strategies are utilized to preserve parotid function without compromising local tumor control. Clinically this is typically done with attending’s directive or via trial-and-error comparison with different sparing tradeoffs. To streamline this process, we proposed a deep reinforcement learning (DRL)-based framework that automatically generates treatment plans with flexibility to adapt to clinical preferences. Approach. A preference-encoded DRL (PEDRL) framework was developed to self-interact with the clinical treatment planning system and dynamically adjust objective constraints in the inverse optimization space. It was powered by the discrete soft actor-critic algorithm with a multi-layer perceptron architecture. The agent interprets intermediate plan status and iteratively modifies objective constraint values in a human-like fashion. By encoding parotid-sparing preferences within the state space, the agent autonomously adapts the sparing strategy to achieve optimal plan quality based on clinical priorities. The agent was trained through iterative treatment plan generation using 40 cases and subsequently tested on additional 44 patients, with generated plans compared to clinical plans. Main results. The PEDRL-generated plans demonstrated comparable performance across all dosimetric evaluation metrics for both bilateral and unilateral sparing cases in the test set. For bilateral cases, the mean value of the parotid median dose was 18.82 Gy (left) and 19.61 Gy (right), compared to 19.31 Gy (left) and 19.12 Gy (right) in the clinical plans. In unilateral sparing cases, the mean value of the spared parotid median dose was 19.92 Gy in the PEDRL-generated plans, compared to 17.16 Gy in the clinical plans. Significance. The proposed novel automated treatment planning framework efficiently generates SIB treatment plans tailored to clinical preferences, demonstrating both effectiveness and adaptability.
- Open Access
- 22 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70057
Characterization, commissioning, and clinical evaluation of a commercial BeO optically stimulated luminescence (OSL) system
This article investigates the performance of a commercial BeO optically stimulated luminescent (OSL) dosimetry system (myOSLchip, RadPro GmbH International, Remscheid, Germany) through the application of the commissioning framework for luminescent dosimeters as described in the American Association of Physicists in Medicine Task Group 191 (AAPM TG191) report. Initial clinical experiences and dosimetric results are also presented. The following properties of the system were characterized: linearity correction factors ranged from ‐0.5% to +3% for dose levels spanning 0.1 to 20 Gy. Beam quality correction factors (relative to 6 MV) ranged from ‐4.5% (2.5FFF) to +4.5% (15MV) for photon beams and +1.9% (6 MeV) to +4.3% (20 MeV) for electron beams. An average (µ) signal loss per reading of ‐2.13% ± 0.20% was measured, however greater signal loss was observed in the first reading (µ = ‐2.6% ± 0.46%). An initial decline in individual element sensitivity relative to baseline was observed from 0–15 Gy cumulative dose (µ = ‐1.98% ± 0.55%), with negligible further deterioration from 15–32 Gy (µ = ‐2.38% ± 0.85%). Post‐irradiation, there was a transient OSL signal which faded with a half‐life of 1.8 min; this signal enhancement was +5% at 5 min post‐irradiation and +1% at 15 min relative to 24 h. Dosimeter response was not dependent on average dose rate in the range of 100–2500 MU/min. With respect to clinical testing, equal or superior performance compared with aluminum oxide OSLs (nanoDots) is shown for a range of clinical techniques and modalities including TSET, TBI, en‐face electrons, and pacemaker/out‐of‐field measurements. The feasibility of myOSLchip to serve as a primary clinical in vivo dosimetry system and direct replacement for Landauer's microStar system is demonstrated.
- 22 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70057
Open AccessCharacterization, commissioning, and clinical evaluation of a commercial BeO optically stimulated luminescence (OSL) system
This article investigates the performance of a commercial BeO optically stimulated luminescent (OSL) dosimetry system (myOSLchip, RadPro GmbH International, Remscheid, Germany) through the application of the commissioning framework for luminescent dosimeters as described in the American Association of Physicists in Medicine Task Group 191 (AAPM TG191) report. Initial clinical experiences and dosimetric results are also presented. The following properties of the system were characterized: linearity correction factors ranged from ‐0.5% to +3% for dose levels spanning 0.1 to 20 Gy. Beam quality correction factors (relative to 6 MV) ranged from ‐4.5% (2.5FFF) to +4.5% (15MV) for photon beams and +1.9% (6 MeV) to +4.3% (20 MeV) for electron beams. An average (µ) signal loss per reading of ‐2.13% ± 0.20% was measured, however greater signal loss was observed in the first reading (µ = ‐2.6% ± 0.46%). An initial decline in individual element sensitivity relative to baseline was observed from 0–15 Gy cumulative dose (µ = ‐1.98% ± 0.55%), with negligible further deterioration from 15–32 Gy (µ = ‐2.38% ± 0.85%). Post‐irradiation, there was a transient OSL signal which faded with a half‐life of 1.8 min; this signal enhancement was +5% at 5 min post‐irradiation and +1% at 15 min relative to 24 h. Dosimeter response was not dependent on average dose rate in the range of 100–2500 MU/min. With respect to clinical testing, equal or superior performance compared with aluminum oxide OSLs (nanoDots) is shown for a range of clinical techniques and modalities including TSET, TBI, en‐face electrons, and pacemaker/out‐of‐field measurements. The feasibility of myOSLchip to serve as a primary clinical in vivo dosimetry system and direct replacement for Landauer's microStar system is demonstrated.
- 24 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (1) , 015010
Automated treatment planning with deep reinforcement learning for head-and-neck (HN) cancer intensity modulated radiation therapy (IMRT)
Purpose. To develop a deep reinforcement learning (DRL) agent to self-interact with the treatment planning system to automatically generate intensity modulated radiation therapy (IMRT) treatment plans for head-and-neck (HN) cancer with consistent organ-at-risk (OAR) sparing performance. Methods. With IRB approval, one hundred and twenty HN patients receiving IMRT were included. The DRL agent was trained with 20 patients. During each inverse optimization process, the intermediate dosimetric endpoints’ values, dose volume constraints’ values and structure objective function losses were collected as the DRL states. By adjusting the objective constraints as actions, the agent learned to seek optimal rewards by balancing OAR sparing and planning target volume (PTV) coverage. Reward computed from current dosimetric endpoints and clinical objectives were sent back to the agent to update action policy during model training. The trained agent was evaluated with the rest 100 patients. Results. The DRL agent was able to generate a clinically acceptable IMRT plan within 12.4 ± 3.1 min without human intervention. DRL plans showed lower PTV maximum dose (109.2%) compared to clinical plans (112.4%) (p < .05). Average median dose of left parotid, right parotid, oral cavity, larynx, pharynx of DRL plans were 15.6 Gy, 12.2 Gy, 25.7 Gy, 27.3 Gy and 32.1 Gy respectively, comparable to 17.1 Gy, 15.7 Gy, 24.4 Gy, 23.7 Gy and 35.5 Gy of corresponding clinical plans. The maximum dose of cord + 5 mm, brainstem and mandible were also comparable between the two groups. In addition, DRL plans demonstrated reduced variability, as evidenced by smaller 95% confidence intervals. The total MU of the DRL plans was 1611 vs 1870 (p < .05) of clinical plans. The results signaled the DRL’s consistent planning strategy compared to the planners’ occasional back-and-forth decision-making during planning. Conclusion. The proposed DRL agent is capable of efficiently generating HN IMRT plans with consistent quality.
- 24 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (1) , 015010
Automated treatment planning with deep reinforcement learning for head-and-neck (HN) cancer intensity modulated radiation therapy (IMRT)
Purpose. To develop a deep reinforcement learning (DRL) agent to self-interact with the treatment planning system to automatically generate intensity modulated radiation therapy (IMRT) treatment plans for head-and-neck (HN) cancer with consistent organ-at-risk (OAR) sparing performance. Methods. With IRB approval, one hundred and twenty HN patients receiving IMRT were included. The DRL agent was trained with 20 patients. During each inverse optimization process, the intermediate dosimetric endpoints’ values, dose volume constraints’ values and structure objective function losses were collected as the DRL states. By adjusting the objective constraints as actions, the agent learned to seek optimal rewards by balancing OAR sparing and planning target volume (PTV) coverage. Reward computed from current dosimetric endpoints and clinical objectives were sent back to the agent to update action policy during model training. The trained agent was evaluated with the rest 100 patients. Results. The DRL agent was able to generate a clinically acceptable IMRT plan within 12.4 ± 3.1 min without human intervention. DRL plans showed lower PTV maximum dose (109.2%) compared to clinical plans (112.4%) (p < .05). Average median dose of left parotid, right parotid, oral cavity, larynx, pharynx of DRL plans were 15.6 Gy, 12.2 Gy, 25.7 Gy, 27.3 Gy and 32.1 Gy respectively, comparable to 17.1 Gy, 15.7 Gy, 24.4 Gy, 23.7 Gy and 35.5 Gy of corresponding clinical plans. The maximum dose of cord + 5 mm, brainstem and mandible were also comparable between the two groups. In addition, DRL plans demonstrated reduced variability, as evidenced by smaller 95% confidence intervals. The total MU of the DRL plans was 1611 vs 1870 (p < .05) of clinical plans. The results signaled the DRL’s consistent planning strategy compared to the planners’ occasional back-and-forth decision-making during planning. Conclusion. The proposed DRL agent is capable of efficiently generating HN IMRT plans with consistent quality.
- 14 November 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (22) , 225018
Understanding and modeling human-AI interaction of artificial intelligence tool in radiation oncology clinic using deep neural network: a feasibility study using three year prospective data
Objective. Artificial intelligence (AI) based treatment planning tools are being implemented in clinic. However, human interactions with such AI tools are rarely analyzed. This study aims to comprehend human planner’s interaction with the AI planning tool and incorporate the analysis to improve the existing AI tool. Approach. An in-house AI tool for whole breast radiation therapy planning was deployed in our institution since 2019, among which 522 patients were included in this study. The AI tool automatically generates fluence maps of the tangential beams to create an AI plan. Human planner makes fluence edits deemed necessary and after attending physician approval for treatment, it is recorded as final plan. Manual modification value maps were collected, which is the difference between the AI-plan and the final plan. Subsequently, a human-AI interaction (HAI) model using full scale connected U-Net was trained to learn such interactions and perform plan enhancements. The trained HAI model automatically modifies the AI plan to generate AI-modified plans (AI-m plan), simulating human editing. Its performance was evaluated against original AI-plan and final plan. Main results. AI-m plan showed statistically significant improvement in hotspot control over the AI plan, with an average of 25.2cc volume reduction in breast V105% (p = 0.011) and 0.805% decrease in Dmax (p < .001). It also maintained the same planning target volume (PTV) coverage as the final plan, demonstrating the model has captured the clinic focus of improving PTV hot spots without degrading coverage. Significance. The proposed HAI model has demonstrated capability of further enhancing the AI plan via modeling human-AI tool interactions. This study shows analysis of human interaction with the AI planning tool is a significant step to improve the AI tool.
- 14 November 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (22) , 225018
Understanding and modeling human-AI interaction of artificial intelligence tool in radiation oncology clinic using deep neural network: a feasibility study using three year prospective data
Objective. Artificial intelligence (AI) based treatment planning tools are being implemented in clinic. However, human interactions with such AI tools are rarely analyzed. This study aims to comprehend human planner’s interaction with the AI planning tool and incorporate the analysis to improve the existing AI tool. Approach. An in-house AI tool for whole breast radiation therapy planning was deployed in our institution since 2019, among which 522 patients were included in this study. The AI tool automatically generates fluence maps of the tangential beams to create an AI plan. Human planner makes fluence edits deemed necessary and after attending physician approval for treatment, it is recorded as final plan. Manual modification value maps were collected, which is the difference between the AI-plan and the final plan. Subsequently, a human-AI interaction (HAI) model using full scale connected U-Net was trained to learn such interactions and perform plan enhancements. The trained HAI model automatically modifies the AI plan to generate AI-modified plans (AI-m plan), simulating human editing. Its performance was evaluated against original AI-plan and final plan. Main results. AI-m plan showed statistically significant improvement in hotspot control over the AI plan, with an average of 25.2cc volume reduction in breast V105% (p = 0.011) and 0.805% decrease in Dmax (p < .001). It also maintained the same planning target volume (PTV) coverage as the final plan, demonstrating the model has captured the clinic focus of improving PTV hot spots without degrading coverage. Significance. The proposed HAI model has demonstrated capability of further enhancing the AI plan via modeling human-AI tool interactions. This study shows analysis of human interaction with the AI planning tool is a significant step to improve the AI tool.
- Open Access
- 6 November 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (1) , e14558
Clinical commissioning and introduction of an in‐house artificial intelligence (AI) platform for automated head and neck intensity modulated radiation therapy (IMRT) treatment planning
Background and purpose: To describe the clinical commissioning of an in‐house artificial intelligence (AI) treatment planning platform for head‐and‐neck (HN) Intensity Modulated Radiation Therapy (IMRT).Materials and methods: The AI planning platform has three components: (1) a graphical user interface (GUI) is built within the framework of a commercial treatment planning system (TPS). The GUI allows AI models to run remotely on a designated workstation configured with GPU acceleration. (2) A template plan is automatically prepared involving both clinical and AI considerations, which include contour evaluation, isocenter placement, and beam/collimator jaw placement. (3) A well‐orchestrated suite of AI models predicts optimal fluence maps, which are imported into TPS for dose calculation followed by an optional automatic fine‐tuning. Six AI models provide flexible tradeoffs in parotid sparing and Planning Target Volume (PTV)‐organ‐at‐risk (OAR) preferences. Planners could examine the plan dose distribution and make further modifications as clinically needed. The performance of the AI plans was compared to the corresponding clinical plans.Results: The average plan generation time including manual operations was 10–15 min per case, with each AI model prediction taking ∼1 s. The six AI plans form a wide range of tradeoff choices between left and right parotids and between PTV and OARs compared with corresponding clinical plans, which correctly reflected their tradeoff designs.Conclusion: The in‐house AI IMRT treatment planning platform was developed and is available for clinical use at our institution. The process demonstrates outstanding performance and robustness of the AI platform and provides sufficient validation.
- 6 November 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (1) , e14558
Open AccessClinical commissioning and introduction of an in‐house artificial intelligence (AI) platform for automated head and neck intensity modulated radiation therapy (IMRT) treatment planning
Background and purpose: To describe the clinical commissioning of an in‐house artificial intelligence (AI) treatment planning platform for head‐and‐neck (HN) Intensity Modulated Radiation Therapy (IMRT).Materials and methods: The AI planning platform has three components: (1) a graphical user interface (GUI) is built within the framework of a commercial treatment planning system (TPS). The GUI allows AI models to run remotely on a designated workstation configured with GPU acceleration. (2) A template plan is automatically prepared involving both clinical and AI considerations, which include contour evaluation, isocenter placement, and beam/collimator jaw placement. (3) A well‐orchestrated suite of AI models predicts optimal fluence maps, which are imported into TPS for dose calculation followed by an optional automatic fine‐tuning. Six AI models provide flexible tradeoffs in parotid sparing and Planning Target Volume (PTV)‐organ‐at‐risk (OAR) preferences. Planners could examine the plan dose distribution and make further modifications as clinically needed. The performance of the AI plans was compared to the corresponding clinical plans.Results: The average plan generation time including manual operations was 10–15 min per case, with each AI model prediction taking ∼1 s. The six AI plans form a wide range of tradeoff choices between left and right parotids and between PTV and OARs compared with corresponding clinical plans, which correctly reflected their tradeoff designs.Conclusion: The in‐house AI IMRT treatment planning platform was developed and is available for clinical use at our institution. The process demonstrates outstanding performance and robustness of the AI platform and provides sufficient validation.
- 21 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (21) , 215009
Input feature design and its impact on the performance of deep learning models for predicting fluence maps in intensity-modulated radiation therapy
Objective . Deep learning (DL) models for fluence map prediction (FMP) have great potential to reduce treatment planning time in intensity-modulated radiation therapy (IMRT) by avoiding the lengthy inverse optimization process. This study aims to improve the rigor of input feature design in a DL-FMP model by examining how different designs of input features influence model prediction performance. Approach . This study included 231 head-and-neck intensity-modulated radiation therapy patients. Three input feature designs were investigated. The first design (D1) assumed that information of all critical structures from all beam angles should be combined to predict fluence maps. The second design (D2) assumed that local anatomical information was sufficient for predicting radiation intensity of a beamlet at a respective beam angle. The third design (D3) assumed the need for both local anatomical information and inter-beam modulation to predict radiation intensity values of the beamlets that intersect at a voxel. For each input design, we tailored the DL model accordingly. All models were trained using the same set of ground truth plans (GT plans). The plans generated by DL models (DL plans) were analyzed using key dose-volume metrics. One-way ANOVA with multiple comparisons correction (Bonferroni method) was performed (significance level = 0.05). Main results . For PTV-related metrics, all DL plans had significantly higher maximum dose ( p < 0.001), conformity index ( p < 0.001), and heterogeneity index ( p < 0.001) compared to GT plans, with D2 being the worst performer. Meanwhile, except for cord+5 mm ( p < 0.001), DL plans of all designs resulted in OAR dose metrics that are comparable to those of GT plans. Significance . Local anatomical information contains most of the information that DL models need to predict fluence maps for clinically acceptable OAR sparing. Input features from beam angles are needed to achieve the best PTV coverage. These results provide valuable insights for further improvement of DL-FMP models and DL models in general.
- 21 October 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (21) , 215009
Input feature design and its impact on the performance of deep learning models for predicting fluence maps in intensity-modulated radiation therapy
Objective . Deep learning (DL) models for fluence map prediction (FMP) have great potential to reduce treatment planning time in intensity-modulated radiation therapy (IMRT) by avoiding the lengthy inverse optimization process. This study aims to improve the rigor of input feature design in a DL-FMP model by examining how different designs of input features influence model prediction performance. Approach . This study included 231 head-and-neck intensity-modulated radiation therapy patients. Three input feature designs were investigated. The first design (D1) assumed that information of all critical structures from all beam angles should be combined to predict fluence maps. The second design (D2) assumed that local anatomical information was sufficient for predicting radiation intensity of a beamlet at a respective beam angle. The third design (D3) assumed the need for both local anatomical information and inter-beam modulation to predict radiation intensity values of the beamlets that intersect at a voxel. For each input design, we tailored the DL model accordingly. All models were trained using the same set of ground truth plans (GT plans). The plans generated by DL models (DL plans) were analyzed using key dose-volume metrics. One-way ANOVA with multiple comparisons correction (Bonferroni method) was performed (significance level = 0.05). Main results . For PTV-related metrics, all DL plans had significantly higher maximum dose ( p < 0.001), conformity index ( p < 0.001), and heterogeneity index ( p < 0.001) compared to GT plans, with D2 being the worst performer. Meanwhile, except for cord+5 mm ( p < 0.001), DL plans of all designs resulted in OAR dose metrics that are comparable to those of GT plans. Significance . Local anatomical information contains most of the information that DL models need to predict fluence maps for clinically acceptable OAR sparing. Input features from beam angles are needed to achieve the best PTV coverage. These results provide valuable insights for further improvement of DL-FMP models and DL models in general.
- 26 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (23) , 23NT01
Insights of an AI agent via analysis of prediction errors: a case study of fluence map prediction for radiation therapy planning
Purpose. We have previously reported an artificial intelligence (AI) agent that automatically generates intensity-modulated radiation therapy (IMRT) plans via fluence map prediction, by-passing inverse planning. This AI agent achieved clinically comparable quality for prostate cases, but its performance on head-and-neck patients leaves room for improvement. This study aims to collect insights of the deep-learning-based (DL-based) fluence map prediction model by systematically analyzing its prediction errors. Methods. From the modeling perspective, the DL model’s output is the fluence maps of IMRT plans. However, from the clinical planning perspective, the plan quality evaluation should be based on the clinical dosimetric criteria such as dose-volume histograms. To account for the complex and non-intuitive relationships between fluence map prediction errors and the corresponding dose distribution changes, we propose a novel error analysis approach that systematically examines plan dosimetric changes that are induced by varying amounts of fluence prediction errors. We investigated four decomposition modes of model prediction errors. The two spatial domain decompositions are based on fluence intensity and fluence gradient. The two frequency domain decompositions are based on Fourier-space banded frequency rings and Fourier-space truncated low-frequency disks. The decomposed error was analyzed for its impact on the resulting plans’ dosimetric metrics. The analysis was conducted on 15 test cases spared from the 200 training and 16 validation cases used to train the model. Results. Most planning target volume metrics were significantly correlated with most error decompositions. The Fourier space disk radii had the largest Spearman’s coefficients. The low-frequency region within a disk of ∼20% Fourier space contained most of errors that impact overall plan quality. Conclusions. This study demonstrates the feasibility of using fluence map prediction error analysis to understand the AI agent’s performance. Such insights will help fine-tune the DL models in architecture design and loss function selection.
- 26 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (23) , 23NT01
Insights of an AI agent via analysis of prediction errors: a case study of fluence map prediction for radiation therapy planning
Purpose. We have previously reported an artificial intelligence (AI) agent that automatically generates intensity-modulated radiation therapy (IMRT) plans via fluence map prediction, by-passing inverse planning. This AI agent achieved clinically comparable quality for prostate cases, but its performance on head-and-neck patients leaves room for improvement. This study aims to collect insights of the deep-learning-based (DL-based) fluence map prediction model by systematically analyzing its prediction errors. Methods. From the modeling perspective, the DL model’s output is the fluence maps of IMRT plans. However, from the clinical planning perspective, the plan quality evaluation should be based on the clinical dosimetric criteria such as dose-volume histograms. To account for the complex and non-intuitive relationships between fluence map prediction errors and the corresponding dose distribution changes, we propose a novel error analysis approach that systematically examines plan dosimetric changes that are induced by varying amounts of fluence prediction errors. We investigated four decomposition modes of model prediction errors. The two spatial domain decompositions are based on fluence intensity and fluence gradient. The two frequency domain decompositions are based on Fourier-space banded frequency rings and Fourier-space truncated low-frequency disks. The decomposed error was analyzed for its impact on the resulting plans’ dosimetric metrics. The analysis was conducted on 15 test cases spared from the 200 training and 16 validation cases used to train the model. Results. Most planning target volume metrics were significantly correlated with most error decompositions. The Fourier space disk radii had the largest Spearman’s coefficients. The low-frequency region within a disk of ∼20% Fourier space contained most of errors that impact overall plan quality. Conclusions. This study demonstrates the feasibility of using fluence map prediction error analysis to understand the AI agent’s performance. Such insights will help fine-tune the DL models in architecture design and loss function selection.
- 28 August 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (17) , 175014
Automatic IMRT planning via static field fluence prediction (AIP-SFFP): a deep learning algorithm for real-time prostate treatment planning
: The purpose of this work was to develop a deep learning (DL) based algorithm, Automatic intensity-modulated radiotherapy (IMRT) Planning via Static Field Fluence Prediction (AIP-SFFP), for automated prostate IMRT planning with real-time planning efficiency. The following method was adopted: AIP-SFFP generates a prostate IMRT plan through predictions of fluence maps using patient anatomy. No inverse planning is required. AIP-SFFP is centered on a custom-built deep learning (DL) neural network for fluence map prediction. Predictions are imported to a commercial treatment-planning system for dose calculation and plan generation. AIP-SFFP was demonstrated for prostate IMRT simultaneously-integrated-boost planning (58.8 Gy/70 Gy to PTV 58.8 Gy /PTV 70 Gy in 28 fx, PTV = Planning Target Volume). Training data was generated from 106 patients using a knowledge-based planning (KBP) plan generator. Two types of 2D projection images were designed to represent structures’ sizes and locations, and a total of eight projections were utilized to describe targets and organs-at-risk. Projections at nine template beam angles were stacked as inputs for artificial intelligence (AI) training. 14 patients were used as independent tests. The generated test plans were compared with the plans from the KBP training plan generator and clinic practice. The following results were obtained: After normalization (PTV 70 Gy V 70 Gy = 95%), all 14 AI plans met institutional criteria. The coverage of PTV 58.8 Gy in the AI plans was comparable to KBP and clinic plans without statistical significance. The whole body (BODY) D1cc and rectum D0.1cc of AI plans were slightly higher (<1 Gy) compared to KBP and clinic plans; in contrast, the bladder D1cc and other rectum and bladder low doses in the AI plans were slightly improved without clinical relevance. The overall isodose distribution in the AI plans was comparable with KBP plans and clinical plans. AIP-SFFP generated each test plan within 20s including the prediction and the dose calculation. In conclusion, AIP-SFFP was successfully developed for prostate IMRT planning. AIP-SFFP demonstrated good overall plan quality and real-time efficiency. Showing great promise, AIP-SFFP will be investigated for immediate clinical application.
- 28 August 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (17) , 175014
Automatic IMRT planning via static field fluence prediction (AIP-SFFP): a deep learning algorithm for real-time prostate treatment planning
: The purpose of this work was to develop a deep learning (DL) based algorithm, Automatic intensity-modulated radiotherapy (IMRT) Planning via Static Field Fluence Prediction (AIP-SFFP), for automated prostate IMRT planning with real-time planning efficiency. The following method was adopted: AIP-SFFP generates a prostate IMRT plan through predictions of fluence maps using patient anatomy. No inverse planning is required. AIP-SFFP is centered on a custom-built deep learning (DL) neural network for fluence map prediction. Predictions are imported to a commercial treatment-planning system for dose calculation and plan generation. AIP-SFFP was demonstrated for prostate IMRT simultaneously-integrated-boost planning (58.8 Gy/70 Gy to PTV 58.8 Gy /PTV 70 Gy in 28 fx, PTV = Planning Target Volume). Training data was generated from 106 patients using a knowledge-based planning (KBP) plan generator. Two types of 2D projection images were designed to represent structures’ sizes and locations, and a total of eight projections were utilized to describe targets and organs-at-risk. Projections at nine template beam angles were stacked as inputs for artificial intelligence (AI) training. 14 patients were used as independent tests. The generated test plans were compared with the plans from the KBP training plan generator and clinic practice. The following results were obtained: After normalization (PTV 70 Gy V 70 Gy = 95%), all 14 AI plans met institutional criteria. The coverage of PTV 58.8 Gy in the AI plans was comparable to KBP and clinic plans without statistical significance. The whole body (BODY) D1cc and rectum D0.1cc of AI plans were slightly higher (<1 Gy) compared to KBP and clinic plans; in contrast, the bladder D1cc and other rectum and bladder low doses in the AI plans were slightly improved without clinical relevance. The overall isodose distribution in the AI plans was comparable with KBP plans and clinical plans. AIP-SFFP generated each test plan within 20s including the prediction and the dose calculation. In conclusion, AIP-SFFP was successfully developed for prostate IMRT planning. AIP-SFFP demonstrated good overall plan quality and real-time efficiency. Showing great promise, AIP-SFFP will be investigated for immediate clinical application.
- Open Access
- 1 January 2019
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 18
A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
Purpose: To optimize collimator setting to improve dosimetric quality of pancreas volumetric modulated arc therapy plan for stereotactic body radiation therapy. Materials and Methods: Fifty-five volumetric modulated arc therapy cases in stereotactic body radiation therapy of pancreas were retrospectively included in this study with internal review board approval. Different from the routine practice of initializing collimator settings with a template, the proposed algorithm simultaneously optimizes the collimator angles and jaw positions that are customized to the patient geometry. Specifically, this algorithm includes 2 key steps: (1) an iterative optimization algorithm via simulated annealing that generates a set of potential collimator settings from 39 cases with pancreas stereotactic body radiation therapy, and (2) a multi-leaf collimator modulation scoring system that makes the final decision of the optimal collimator settings (collimator angles and jaw positions) based on organs at risk sparing criteria. For validation, the other 16 cases with pancreas stereotactic body radiation therapy were analyzed. Two plans were generated for each validation case, with one plan optimized using the proposed algorithm ( Planopt) and the other plan with the template setting ( Planconv). Each plan was optimized with 2 full arcs and the same set of constraints for the same case. Dosimetric results were analyzed and compared, including target dose coverage, conformity, organs at risk maximum dose, and modulation complexity score. All results were tested by Wilcoxon signed rank tests, and the statistical significance level was set to .05. Results: Both plan groups had comparable target dose coverage and mean doses of all organs at risk. However, organs at risk (stomach, duodenum, large/small bowel) maximum dose sparing ( D0.1 cc and D0.03 cc) was improved in Planopt compared to Planconv. Planopt also showed lower modulation complexity score, which suggests better capability of handling complex shape and sparing organs at risk . Conclusions: The proposed collimator settings optimization algorithm successfully improved dosimetric performance for dual-arc pancreas volumetric modulated arc therapy plans in stereotactic body radiation therapy of pancreas. This algorithm has the capability of immediate clinical application.
- 1 January 2019
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 18
Open AccessA Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
Purpose: To optimize collimator setting to improve dosimetric quality of pancreas volumetric modulated arc therapy plan for stereotactic body radiation therapy. Materials and Methods: Fifty-five volumetric modulated arc therapy cases in stereotactic body radiation therapy of pancreas were retrospectively included in this study with internal review board approval. Different from the routine practice of initializing collimator settings with a template, the proposed algorithm simultaneously optimizes the collimator angles and jaw positions that are customized to the patient geometry. Specifically, this algorithm includes 2 key steps: (1) an iterative optimization algorithm via simulated annealing that generates a set of potential collimator settings from 39 cases with pancreas stereotactic body radiation therapy, and (2) a multi-leaf collimator modulation scoring system that makes the final decision of the optimal collimator settings (collimator angles and jaw positions) based on organs at risk sparing criteria. For validation, the other 16 cases with pancreas stereotactic body radiation therapy were analyzed. Two plans were generated for each validation case, with one plan optimized using the proposed algorithm ( Planopt) and the other plan with the template setting ( Planconv). Each plan was optimized with 2 full arcs and the same set of constraints for the same case. Dosimetric results were analyzed and compared, including target dose coverage, conformity, organs at risk maximum dose, and modulation complexity score. All results were tested by Wilcoxon signed rank tests, and the statistical significance level was set to .05. Results: Both plan groups had comparable target dose coverage and mean doses of all organs at risk. However, organs at risk (stomach, duodenum, large/small bowel) maximum dose sparing ( D0.1 cc and D0.03 cc) was improved in Planopt compared to Planconv. Planopt also showed lower modulation complexity score, which suggests better capability of handling complex shape and sparing organs at risk . Conclusions: The proposed collimator settings optimization algorithm successfully improved dosimetric performance for dual-arc pancreas volumetric modulated arc therapy plans in stereotactic body radiation therapy of pancreas. This algorithm has the capability of immediate clinical application.