Tracey Dawson Cruz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tracey Dawson Cruz has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Jordan O. Cox
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
7 shared publications - Sarah J. Seashols-Williams
Department of Forensic Science Virginia Commonwealth University Richmond Virginia USA
5 shared publications - Brittany C. Hudson
Department of Forensic Science Virginia Commonwealth University Richmond Virginia USA
4 shared publications - Chastyn Smith
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
4 shared publications - Edward L. Boone
Department of Statistical Sciences and Operations Research, Virginia Commonwealth University, Richmond, VA 23284, USA
3 shared publications - Darianne C. Cloudy
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
2 shared publications
Latest Publications
- Open Access
- 1 February 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 139 (3) , 1045-1052
Integration of a high-resolution melt curve assay into a commercial quantification kit for preliminary identification of biological mixtures
In recent years, DNA analysis techniques have drastically increased in sensitivity, allowing for low template DNA samples to be more easily detected and used for identification. Since the problems inherent in low template DNA are exacerbated in DNA mixture samples, it would be advantageous to incorporate an assay earlier in the DNA workflow that could detect a mixture and, potentially, determine the number of contributors. Some real-time PCR instruments have high-resolution melt curve analysis (HRM) capabilities, allowing for an opportunity to integrate an HRM screening assay into a commercial DNA quantification kit. This work describes the integration of a mixture screening HRM assay using STR loci D5S818 and D18S51 into Qiagen’s Investigator Quantiplex® kit. The integrated Quantiplex®-HRM assay was tested on two qPCR platforms: The Rotor-Gene® Q and the QuantStudio™ 6 Flex. Data from this assay was analyzed using linear discriminant and support vector machine analyses for sample classification. When HRM curve data from the Rotor-Gene® Q was used for classification, the integrated assay exhibited an overall accuracy of 89.39%, correctly classifying 87.5% of single source samples and 100% of mixtures. When HRM curve data from the QuantStudio™ 6 Flex was used for classification, the integrated assay exhibited an overall accuracy of 87.88%, correctly classifying 87.5% of single source samples and 90% of mixtures. The overall accuracy of the integrated Quantiplex®-HRM assay on both instruments met our goal of ≥ 80% accuracy, demonstrating the viability of the assay to detect mixtures when integrated into a commercial quantification kit.
- 1 February 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 139 (3) , 1045-1052
Open AccessIntegration of a high-resolution melt curve assay into a commercial quantification kit for preliminary identification of biological mixtures
In recent years, DNA analysis techniques have drastically increased in sensitivity, allowing for low template DNA samples to be more easily detected and used for identification. Since the problems inherent in low template DNA are exacerbated in DNA mixture samples, it would be advantageous to incorporate an assay earlier in the DNA workflow that could detect a mixture and, potentially, determine the number of contributors. Some real-time PCR instruments have high-resolution melt curve analysis (HRM) capabilities, allowing for an opportunity to integrate an HRM screening assay into a commercial DNA quantification kit. This work describes the integration of a mixture screening HRM assay using STR loci D5S818 and D18S51 into Qiagen’s Investigator Quantiplex® kit. The integrated Quantiplex®-HRM assay was tested on two qPCR platforms: The Rotor-Gene® Q and the QuantStudio™ 6 Flex. Data from this assay was analyzed using linear discriminant and support vector machine analyses for sample classification. When HRM curve data from the Rotor-Gene® Q was used for classification, the integrated assay exhibited an overall accuracy of 89.39%, correctly classifying 87.5% of single source samples and 100% of mixtures. When HRM curve data from the QuantStudio™ 6 Flex was used for classification, the integrated assay exhibited an overall accuracy of 87.88%, correctly classifying 87.5% of single source samples and 90% of mixtures. The overall accuracy of the integrated Quantiplex®-HRM assay on both instruments met our goal of ≥ 80% accuracy, demonstrating the viability of the assay to detect mixtures when integrated into a commercial quantification kit.
- Open Access
- 13 July 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2281-2288
Statistical methods for discrimination of STR genotypes using high resolution melt curve data
Despite the improvements in forensic DNA quantification methods that allow for the early detection of low template/challenged DNA samples, complicating stochastic effects are not revealed until the final stage of the DNA analysis workflow. An assay that would provide genotyping information at the earlier stage of quantification would allow examiners to make critical adjustments prior to STR amplification allowing for potentially exclusionary information to be immediately reported. Specifically, qPCR instruments often have dissociation curve and/or high-resolution melt curve (HRM) capabilities; this, coupled with statistical prediction analysis, could provide additional information regarding STR genotypes present. Thus, this study aimed to evaluate Qiagen’s principal component analysis (PCA)-based ScreenClust® HRM® software and a linear discriminant analysis (LDA)-based technique for their abilities to accurately predict genotypes and similar groups of genotypes from HRM data. Melt curves from single source samples were generated from STR D5S818 and D18S51 amplicons using a Rotor-Gene® Q qPCR instrument and EvaGreen® intercalating dye. When used to predict D5S818 genotypes for unknown samples, LDA analysis outperformed the PCA-based method whether predictions were for individual genotypes (58.92% accuracy) or for geno-groups (81.00% accuracy). However, when a locus with increased heterogeneity was tested (D18S51), PCA-based prediction accuracy rates improved to rates similar to those obtained using LDA (45.10% and 63.46%, respectively). This study provides foundational data documenting the performance of prediction modeling for STR genotyping based on qPCR-HRM data. In order to expand the forensic applicability of this HRM assay, the method could be tested with a more commonly utilized qPCR platform.
- 13 July 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2281-2288
Open AccessStatistical methods for discrimination of STR genotypes using high resolution melt curve data
Despite the improvements in forensic DNA quantification methods that allow for the early detection of low template/challenged DNA samples, complicating stochastic effects are not revealed until the final stage of the DNA analysis workflow. An assay that would provide genotyping information at the earlier stage of quantification would allow examiners to make critical adjustments prior to STR amplification allowing for potentially exclusionary information to be immediately reported. Specifically, qPCR instruments often have dissociation curve and/or high-resolution melt curve (HRM) capabilities; this, coupled with statistical prediction analysis, could provide additional information regarding STR genotypes present. Thus, this study aimed to evaluate Qiagen’s principal component analysis (PCA)-based ScreenClust® HRM® software and a linear discriminant analysis (LDA)-based technique for their abilities to accurately predict genotypes and similar groups of genotypes from HRM data. Melt curves from single source samples were generated from STR D5S818 and D18S51 amplicons using a Rotor-Gene® Q qPCR instrument and EvaGreen® intercalating dye. When used to predict D5S818 genotypes for unknown samples, LDA analysis outperformed the PCA-based method whether predictions were for individual genotypes (58.92% accuracy) or for geno-groups (81.00% accuracy). However, when a locus with increased heterogeneity was tested (D18S51), PCA-based prediction accuracy rates improved to rates similar to those obtained using LDA (45.10% and 63.46%, respectively). This study provides foundational data documenting the performance of prediction modeling for STR genotyping based on qPCR-HRM data. In order to expand the forensic applicability of this HRM assay, the method could be tested with a more commonly utilized qPCR platform.
- Open Access
An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage
Although guidelines exist for identifying mixtures, these measures often occur at the end-point of analysis and are protracted. To facilitate early mixture detection, we integrated a high-resolution melt (HRM) mixture screening assay into the qPCR step of the forensic workflow, producing the integrated QuantifilerTM Trio-HRM assay. The assay, when coupled with a prediction tool, allowed for 75.0% accurate identification of the contributor status of a sample (single source vs. mixture). To elucidate the limitations of the developed qPCR-HRM assay, developmental validation studies were conducted assessing the reproducibility and samples with varying DNA ratios, contributors, and quality. From this work, it was determined that the integrated QuantifilerTM Trio-HRM assay is capable of accurately identifying mixtures with up to five contributors and mixtures at ratios up to 1:100. Further, the optimal performance concentration range was found to be between 0.025 and 0.5 ng/µL. With these results, evidentiary-like DNA samples were then analyzed, resulting in 100.0% of the mixture samples being accurately identified; furthermore, every time a sample was predicted as a single source, it was true, giving confidence to any single-source calls. Overall, the integrated QuantifilerTM Trio-HRM assay has exhibited an enhanced ability to discern mixture samples from single-source samples at the qPCR stage under commonly observed conditions regardless of the contributor’s sex.
Open AccessAn Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage
Although guidelines exist for identifying mixtures, these measures often occur at the end-point of analysis and are protracted. To facilitate early mixture detection, we integrated a high-resolution melt (HRM) mixture screening assay into the qPCR step of the forensic workflow, producing the integrated QuantifilerTM Trio-HRM assay. The assay, when coupled with a prediction tool, allowed for 75.0% accurate identification of the contributor status of a sample (single source vs. mixture). To elucidate the limitations of the developed qPCR-HRM assay, developmental validation studies were conducted assessing the reproducibility and samples with varying DNA ratios, contributors, and quality. From this work, it was determined that the integrated QuantifilerTM Trio-HRM assay is capable of accurately identifying mixtures with up to five contributors and mixtures at ratios up to 1:100. Further, the optimal performance concentration range was found to be between 0.025 and 0.5 ng/µL. With these results, evidentiary-like DNA samples were then analyzed, resulting in 100.0% of the mixture samples being accurately identified; furthermore, every time a sample was predicted as a single source, it was true, giving confidence to any single-source calls. Overall, the integrated QuantifilerTM Trio-HRM assay has exhibited an enhanced ability to discern mixture samples from single-source samples at the qPCR stage under commonly observed conditions regardless of the contributor’s sex.
- Open Access
- 1 October 2023
- Published by Wiley in Journal of Forensic Sciences
- Vol. 68 (6) , 2116-2127
Alternative direct‐to‐amplification cell lysis techniques for forensically relevant non‐sperm cells
While efforts have been made to reduce the pervasive backlog of sexual assault evidence collection kits, the actual laboratory process remains very time-consuming due to the requirement of a differential lysis step before DNA purification, as well as intricate mixture analysis towards the end of the DNA workflow. Recently, an alternative, direct-to-amplification sperm lysis method (using 1 M NaOH) was identified. However, a direct cell lysis method for non-sperm cells has not been identified yet. Thus, the primary objective of this work was to find an alternative method that is quick, inexpensive, and does not require multiple purification steps for the lysis of non-sperm cells in sexual assault samples. In this study, vaginal swab samples were lysed with the control method, prepGEM (TM), as well as six alternative reagents: alkaline buffer with 25-200 mM NaOH, high-salt stain extraction buffer, modified radioimmunoprecipitation assay (RIPA) buffer, mammalian protein extraction reagent (M-PER (TM)), digitonin buffer, and urea/thiourea buffer. Quantification using Quantifiler (R) Trio of vaginal and semen lysates revealed that the alkaline (25 mM NaOH) and M-PER (TM) methods were efficient for the lysis of vaginal epithelial cells without substantial sperm cell lysis. Following quantification, analysis of STR profiles from vaginal lysates revealed that the M-PER (TM) method showed promising results across all metrics examined, including the percentage of detected STR alleles, mean peak heights, peak height ratio, and interlocus balance. Thus, this method was recommended as an alternative to the traditional differential lysis method for non-sperm cells given its ability to produce amplification-ready lysates without any DNA purification step.
- 1 October 2023
- Published by Wiley in Journal of Forensic Sciences
- Vol. 68 (6) , 2116-2127
Open AccessAlternative direct‐to‐amplification cell lysis techniques for forensically relevant non‐sperm cells
While efforts have been made to reduce the pervasive backlog of sexual assault evidence collection kits, the actual laboratory process remains very time-consuming due to the requirement of a differential lysis step before DNA purification, as well as intricate mixture analysis towards the end of the DNA workflow. Recently, an alternative, direct-to-amplification sperm lysis method (using 1 M NaOH) was identified. However, a direct cell lysis method for non-sperm cells has not been identified yet. Thus, the primary objective of this work was to find an alternative method that is quick, inexpensive, and does not require multiple purification steps for the lysis of non-sperm cells in sexual assault samples. In this study, vaginal swab samples were lysed with the control method, prepGEM (TM), as well as six alternative reagents: alkaline buffer with 25-200 mM NaOH, high-salt stain extraction buffer, modified radioimmunoprecipitation assay (RIPA) buffer, mammalian protein extraction reagent (M-PER (TM)), digitonin buffer, and urea/thiourea buffer. Quantification using Quantifiler (R) Trio of vaginal and semen lysates revealed that the alkaline (25 mM NaOH) and M-PER (TM) methods were efficient for the lysis of vaginal epithelial cells without substantial sperm cell lysis. Following quantification, analysis of STR profiles from vaginal lysates revealed that the M-PER (TM) method showed promising results across all metrics examined, including the percentage of detected STR alleles, mean peak heights, peak height ratio, and interlocus balance. Thus, this method was recommended as an alternative to the traditional differential lysis method for non-sperm cells given its ability to produce amplification-ready lysates without any DNA purification step.
- Open Access
- 13 March 2022
- Published by Wiley in Journal of Forensic Sciences
- Vol. 67 (4) , 1668-1678
Alternative direct‐to‐amplification sperm cell lysis techniques for sexual assault sample processing
The prevalence of sexual assault cases and increasingly sensitive DNA analysis methods have resulted in sexual assault kit backlogs in the United States. Although traditional DNA extraction and purification utilizing detergents, proteinase K, and DTT have been the primary technique for lysing sperm cell fractions from these samples, it is labor-intensive and inefficient regarding time and sperm DNA recovery - hindering the ability of forensic analysts to keep pace with evidence submissions. Thus, this study examined seven alternative sperm cell lysis techniques to develop a method that could efficiently lyse sperm and consistently generate high-quality profiles while also reducing time, labor, and cost requirements. Microscopic examination of lysates indicated only Casework Direct and alkaline techniques could lyse all spermatozoa within samples, while quantification results demonstrated all methods performed comparably to the control method of forensicGEM (TM) Sperm (p > 0.06). Amplification with 0.25 ng DNA revealed that unpurified lysates from Casework Direct, alkaline, and NP-40 techniques produced DNA profiles with acceptable mean STR peak heights and interlocus balance, both of which were similar to or better than the control. Overall, this study demonstrated the ability of Casework Direct, alkaline, and NP-40 methods to efficiently lyse spermatozoa and provide high-quality STR profiles despite the absence of a purification step. Ultimately, based on the data reported herein, alkaline lysis is the recommended alternative sperm lysis approach given its ability to generate high-quality profiles, save time, and decrease the cost per reaction when compared to traditional sperm cell lysis methods.
- 13 March 2022
- Published by Wiley in Journal of Forensic Sciences
- Vol. 67 (4) , 1668-1678
Open AccessAlternative direct‐to‐amplification sperm cell lysis techniques for sexual assault sample processing
The prevalence of sexual assault cases and increasingly sensitive DNA analysis methods have resulted in sexual assault kit backlogs in the United States. Although traditional DNA extraction and purification utilizing detergents, proteinase K, and DTT have been the primary technique for lysing sperm cell fractions from these samples, it is labor-intensive and inefficient regarding time and sperm DNA recovery - hindering the ability of forensic analysts to keep pace with evidence submissions. Thus, this study examined seven alternative sperm cell lysis techniques to develop a method that could efficiently lyse sperm and consistently generate high-quality profiles while also reducing time, labor, and cost requirements. Microscopic examination of lysates indicated only Casework Direct and alkaline techniques could lyse all spermatozoa within samples, while quantification results demonstrated all methods performed comparably to the control method of forensicGEM (TM) Sperm (p > 0.06). Amplification with 0.25 ng DNA revealed that unpurified lysates from Casework Direct, alkaline, and NP-40 techniques produced DNA profiles with acceptable mean STR peak heights and interlocus balance, both of which were similar to or better than the control. Overall, this study demonstrated the ability of Casework Direct, alkaline, and NP-40 methods to efficiently lyse spermatozoa and provide high-quality STR profiles despite the absence of a purification step. Ultimately, based on the data reported herein, alkaline lysis is the recommended alternative sperm lysis approach given its ability to generate high-quality profiles, save time, and decrease the cost per reaction when compared to traditional sperm cell lysis methods.
- 24 February 2021
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (4) , 1427-1434
Comparison of DNA typing success in compromised blood and touch samples based on sampling swab composition
Sample collection at the crime scene can introduce variations in DNA recovery based upon the substrate from which a sample is collected, the material of the collection device used, or the storage conditions after collection. There are many factors during this process that can degrade the sample during drying and storage, and before DNA extraction can be performed. The purpose of this study was to evaluate and compare the performance of standard cotton swab collection with the Bode BioSafe® swab, which includes both a desiccant at the swab head and proprietary compounds to prevent degradation of the sample during sample collection and preservation. Blood and touch DNA samples were collected from porous and nonporous substrates and stored at elevated temperatures to simulate accelerated time. DNA quantification and STR profile data were used to assess the performance of the swabs. BioSafe® swab collection resulted in similar DNA yields from blood samples and significantly higher DNA yields from touch samples when compared to collection with cotton swabs. BioSafe® swabs also resulted in higher DNA integrity during long‐term storage, increased STR profile success and improved retention of low‐level contributor alleles.
- 24 February 2021
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (4) , 1427-1434
Comparison of DNA typing success in compromised blood and touch samples based on sampling swab composition
Sample collection at the crime scene can introduce variations in DNA recovery based upon the substrate from which a sample is collected, the material of the collection device used, or the storage conditions after collection. There are many factors during this process that can degrade the sample during drying and storage, and before DNA extraction can be performed. The purpose of this study was to evaluate and compare the performance of standard cotton swab collection with the Bode BioSafe® swab, which includes both a desiccant at the swab head and proprietary compounds to prevent degradation of the sample during sample collection and preservation. Blood and touch DNA samples were collected from porous and nonporous substrates and stored at elevated temperatures to simulate accelerated time. DNA quantification and STR profile data were used to assess the performance of the swabs. BioSafe® swab collection resulted in similar DNA yields from blood samples and significantly higher DNA yields from touch samples when compared to collection with cotton swabs. BioSafe® swabs also resulted in higher DNA integrity during long‐term storage, increased STR profile success and improved retention of low‐level contributor alleles.
- Open Access
- 1 February 2021
- Published by Elsevier in SLAS Technology
- Vol. 26 (1) , 103-112
Performance Comparison of Massively Parallel Sequencing (MPS) Instruments Using Single-Nucleotide Polymorphism (SNP) Panels for Ancestry
- 1 February 2021
- Published by Elsevier in SLAS Technology
- Vol. 26 (1) , 103-112
Open AccessPerformance Comparison of Massively Parallel Sequencing (MPS) Instruments Using Single-Nucleotide Polymorphism (SNP) Panels for Ancestry
- 7 December 2020
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (2) , 700-708
The effects of dithiothreitol (DTT) on fluorescent qPCR dyes
DNA extractions of semen samples commonly utilize dithiothreitol (DTT) to reduce and disrupt disulfide bonds. Although traditional extraction techniques remove DTT before downstream analyses, the forensic DNA community has recently explored Y‐screening, direct amplification, and direct cell lysis assays that omit purification but employ reducing agents to lyse spermatozoa. This study examined the impact of residual DTT on downstream processes involving fluorescent dyes. Quantification using Investigator® Quantiplex HYres revealed a significant increase in the male DNA yield (p = 0.00056) and a >150,000,000‐fold increase in the male:human DNA ratio when DTT remained in extracts versus when it was filtered out using a traditional purification method. When DTT was present with Quantifiler™ Trio, the true mean DNA yield for the large autosomal target significantly increased (p = 0.038) and the average reported DNA yields increased 1.1‐fold, >9.5‐fold, and 1.3‐fold for the small autosomal, large autosomal, and male targets, respectively. DTT‐spiked DNA standards from both kits were impacted similarly to samples with residual DTT, demonstrating that observed effects were related to DTT and not the extraction method. This study corroborates other reports that DTT adversely affects multiple dyes (e.g., Cy5, Quasar 670, SYBR Green I, TMR, and Mustang Purple®). Overall, DTT causes inaccurate quantities and, consequently, inaccurate calculated male:female ratios when used in conjunction with these kits. Thus, implementation of newer direct‐to‐PCR assays incorporating DTT should either be avoided or used only with carefully evaluated, compatible dyes.
- 7 December 2020
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (2) , 700-708
The effects of dithiothreitol (DTT) on fluorescent qPCR dyes
DNA extractions of semen samples commonly utilize dithiothreitol (DTT) to reduce and disrupt disulfide bonds. Although traditional extraction techniques remove DTT before downstream analyses, the forensic DNA community has recently explored Y‐screening, direct amplification, and direct cell lysis assays that omit purification but employ reducing agents to lyse spermatozoa. This study examined the impact of residual DTT on downstream processes involving fluorescent dyes. Quantification using Investigator® Quantiplex HYres revealed a significant increase in the male DNA yield (p = 0.00056) and a >150,000,000‐fold increase in the male:human DNA ratio when DTT remained in extracts versus when it was filtered out using a traditional purification method. When DTT was present with Quantifiler™ Trio, the true mean DNA yield for the large autosomal target significantly increased (p = 0.038) and the average reported DNA yields increased 1.1‐fold, >9.5‐fold, and 1.3‐fold for the small autosomal, large autosomal, and male targets, respectively. DTT‐spiked DNA standards from both kits were impacted similarly to samples with residual DTT, demonstrating that observed effects were related to DTT and not the extraction method. This study corroborates other reports that DTT adversely affects multiple dyes (e.g., Cy5, Quasar 670, SYBR Green I, TMR, and Mustang Purple®). Overall, DTT causes inaccurate quantities and, consequently, inaccurate calculated male:female ratios when used in conjunction with these kits. Thus, implementation of newer direct‐to‐PCR assays incorporating DTT should either be avoided or used only with carefully evaluated, compatible dyes.
- Open Access
- 3 August 2020
- Published by Shanghai Institute of Optics and Fine Mechanics in Forensic Sciences Research
- Vol. 7 (1) , 61-68
Effects of storage time on DNA profiling success from archived latent fingerprint samples using an optimised workflow
Due to recent improvements in forensic DNA testing kit sensitivity, there has been an increased demand in the criminal justice community to revisit past convictions or cold cases. Some of these cases have little biological evidence other than touch DNA in the form of archived latent fingerprint lift cards. In this study, a previously developed optimised workflow for this sample type was tested on aged fingerprints to determine if improved short tandem repeat (STR) profiles could be obtained. Two-year-old samples processed with the optimised workflow produced an average of approximately five more STR alleles per profile over the traditional method. The optimised workflow also produced detectable alleles in samples aged out to 28 years. Of the methods tested, the optimised workflow resulted in the most informative profiles from evidence samples more representative of the forensic need. This workflow is recommended for use with archived latent fingerprint samples, regardless of the archival time.
- 3 August 2020
- Published by Shanghai Institute of Optics and Fine Mechanics in Forensic Sciences Research
- Vol. 7 (1) , 61-68
Open AccessEffects of storage time on DNA profiling success from archived latent fingerprint samples using an optimised workflow
Due to recent improvements in forensic DNA testing kit sensitivity, there has been an increased demand in the criminal justice community to revisit past convictions or cold cases. Some of these cases have little biological evidence other than touch DNA in the form of archived latent fingerprint lift cards. In this study, a previously developed optimised workflow for this sample type was tested on aged fingerprints to determine if improved short tandem repeat (STR) profiles could be obtained. Two-year-old samples processed with the optimised workflow produced an average of approximately five more STR alleles per profile over the traditional method. The optimised workflow also produced detectable alleles in samples aged out to 28 years. Of the methods tested, the optimised workflow resulted in the most informative profiles from evidence samples more representative of the forensic need. This workflow is recommended for use with archived latent fingerprint samples, regardless of the archival time.
- Open Access
- 20 August 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Forensic Sciences Research
- Vol. 5 (2) , 106-112
Improved resolution of mixed STR profiles using a fully automated differential cell lysis/DNA extraction method
Sexual assault evidence often contains sperm cells, which are typically separated from nonsperm cells using manual differential lysis procedures. The goal of this study was to evaluate the automated QIAGEN QIAcube for this purpose and to compare it to manual QIAGEN and manual organic differential methods using DNA yields and STR profile data for assessment. DNA yields were determined by qPCR, followed by multiplex STR amplification, CE analysis, and mixture interpretation. The automated method was capable of effective cell separation, producing DNA yields sufficient for STR amplification. Further, sperm fraction human:male DNA ratios from the QIAcube samples were consistently closer to the desired 1:1 and STR profiles were less likely to result in mixtures, with 6–8× fewer female alleles detected (median 1.5 alleles). Ultimately, using the QIAcube for automated differential processing of semen-containing mixtures reduces the need for downstream mixture interpretation and improves STR profile quality with substantially less hands-on time.
- 20 August 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Forensic Sciences Research
- Vol. 5 (2) , 106-112
Open AccessImproved resolution of mixed STR profiles using a fully automated differential cell lysis/DNA extraction method
Sexual assault evidence often contains sperm cells, which are typically separated from nonsperm cells using manual differential lysis procedures. The goal of this study was to evaluate the automated QIAGEN QIAcube for this purpose and to compare it to manual QIAGEN and manual organic differential methods using DNA yields and STR profile data for assessment. DNA yields were determined by qPCR, followed by multiplex STR amplification, CE analysis, and mixture interpretation. The automated method was capable of effective cell separation, producing DNA yields sufficient for STR amplification. Further, sperm fraction human:male DNA ratios from the QIAcube samples were consistently closer to the desired 1:1 and STR profiles were less likely to result in mixtures, with 6–8× fewer female alleles detected (median 1.5 alleles). Ultimately, using the QIAcube for automated differential processing of semen-containing mixtures reduces the need for downstream mixture interpretation and improves STR profile quality with substantially less hands-on time.