Chastyn Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chastyn Smith has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Sarah J. Seashols-Williams
Department of Forensic Science Virginia Commonwealth University Richmond Virginia USA
4 shared publications - Tracey Dawson Cruz
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
4 shared publications - Edward L. Boone
Department of Statistical Sciences and Operations Research, Virginia Commonwealth University, Richmond, VA 23284, USA
3 shared publications - Jordan O. Cox
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
3 shared publications Andrea L. Williams
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
2 shared publications- Darianne C. Cloudy
Department of Forensic Science, Virginia Commonwealth University, Richmond, USA
2 shared publications
Latest Publications
- Open Access
- 1 February 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 139 (3) , 1045-1052
Integration of a high-resolution melt curve assay into a commercial quantification kit for preliminary identification of biological mixtures
In recent years, DNA analysis techniques have drastically increased in sensitivity, allowing for low template DNA samples to be more easily detected and used for identification. Since the problems inherent in low template DNA are exacerbated in DNA mixture samples, it would be advantageous to incorporate an assay earlier in the DNA workflow that could detect a mixture and, potentially, determine the number of contributors. Some real-time PCR instruments have high-resolution melt curve analysis (HRM) capabilities, allowing for an opportunity to integrate an HRM screening assay into a commercial DNA quantification kit. This work describes the integration of a mixture screening HRM assay using STR loci D5S818 and D18S51 into Qiagen’s Investigator Quantiplex® kit. The integrated Quantiplex®-HRM assay was tested on two qPCR platforms: The Rotor-Gene® Q and the QuantStudio™ 6 Flex. Data from this assay was analyzed using linear discriminant and support vector machine analyses for sample classification. When HRM curve data from the Rotor-Gene® Q was used for classification, the integrated assay exhibited an overall accuracy of 89.39%, correctly classifying 87.5% of single source samples and 100% of mixtures. When HRM curve data from the QuantStudio™ 6 Flex was used for classification, the integrated assay exhibited an overall accuracy of 87.88%, correctly classifying 87.5% of single source samples and 90% of mixtures. The overall accuracy of the integrated Quantiplex®-HRM assay on both instruments met our goal of ≥ 80% accuracy, demonstrating the viability of the assay to detect mixtures when integrated into a commercial quantification kit.
- 1 February 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 139 (3) , 1045-1052
Open AccessIntegration of a high-resolution melt curve assay into a commercial quantification kit for preliminary identification of biological mixtures
In recent years, DNA analysis techniques have drastically increased in sensitivity, allowing for low template DNA samples to be more easily detected and used for identification. Since the problems inherent in low template DNA are exacerbated in DNA mixture samples, it would be advantageous to incorporate an assay earlier in the DNA workflow that could detect a mixture and, potentially, determine the number of contributors. Some real-time PCR instruments have high-resolution melt curve analysis (HRM) capabilities, allowing for an opportunity to integrate an HRM screening assay into a commercial DNA quantification kit. This work describes the integration of a mixture screening HRM assay using STR loci D5S818 and D18S51 into Qiagen’s Investigator Quantiplex® kit. The integrated Quantiplex®-HRM assay was tested on two qPCR platforms: The Rotor-Gene® Q and the QuantStudio™ 6 Flex. Data from this assay was analyzed using linear discriminant and support vector machine analyses for sample classification. When HRM curve data from the Rotor-Gene® Q was used for classification, the integrated assay exhibited an overall accuracy of 89.39%, correctly classifying 87.5% of single source samples and 100% of mixtures. When HRM curve data from the QuantStudio™ 6 Flex was used for classification, the integrated assay exhibited an overall accuracy of 87.88%, correctly classifying 87.5% of single source samples and 90% of mixtures. The overall accuracy of the integrated Quantiplex®-HRM assay on both instruments met our goal of ≥ 80% accuracy, demonstrating the viability of the assay to detect mixtures when integrated into a commercial quantification kit.
- Open Access
- 13 July 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2281-2288
Statistical methods for discrimination of STR genotypes using high resolution melt curve data
Despite the improvements in forensic DNA quantification methods that allow for the early detection of low template/challenged DNA samples, complicating stochastic effects are not revealed until the final stage of the DNA analysis workflow. An assay that would provide genotyping information at the earlier stage of quantification would allow examiners to make critical adjustments prior to STR amplification allowing for potentially exclusionary information to be immediately reported. Specifically, qPCR instruments often have dissociation curve and/or high-resolution melt curve (HRM) capabilities; this, coupled with statistical prediction analysis, could provide additional information regarding STR genotypes present. Thus, this study aimed to evaluate Qiagen’s principal component analysis (PCA)-based ScreenClust® HRM® software and a linear discriminant analysis (LDA)-based technique for their abilities to accurately predict genotypes and similar groups of genotypes from HRM data. Melt curves from single source samples were generated from STR D5S818 and D18S51 amplicons using a Rotor-Gene® Q qPCR instrument and EvaGreen® intercalating dye. When used to predict D5S818 genotypes for unknown samples, LDA analysis outperformed the PCA-based method whether predictions were for individual genotypes (58.92% accuracy) or for geno-groups (81.00% accuracy). However, when a locus with increased heterogeneity was tested (D18S51), PCA-based prediction accuracy rates improved to rates similar to those obtained using LDA (45.10% and 63.46%, respectively). This study provides foundational data documenting the performance of prediction modeling for STR genotyping based on qPCR-HRM data. In order to expand the forensic applicability of this HRM assay, the method could be tested with a more commonly utilized qPCR platform.
- 13 July 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2281-2288
Open AccessStatistical methods for discrimination of STR genotypes using high resolution melt curve data
Despite the improvements in forensic DNA quantification methods that allow for the early detection of low template/challenged DNA samples, complicating stochastic effects are not revealed until the final stage of the DNA analysis workflow. An assay that would provide genotyping information at the earlier stage of quantification would allow examiners to make critical adjustments prior to STR amplification allowing for potentially exclusionary information to be immediately reported. Specifically, qPCR instruments often have dissociation curve and/or high-resolution melt curve (HRM) capabilities; this, coupled with statistical prediction analysis, could provide additional information regarding STR genotypes present. Thus, this study aimed to evaluate Qiagen’s principal component analysis (PCA)-based ScreenClust® HRM® software and a linear discriminant analysis (LDA)-based technique for their abilities to accurately predict genotypes and similar groups of genotypes from HRM data. Melt curves from single source samples were generated from STR D5S818 and D18S51 amplicons using a Rotor-Gene® Q qPCR instrument and EvaGreen® intercalating dye. When used to predict D5S818 genotypes for unknown samples, LDA analysis outperformed the PCA-based method whether predictions were for individual genotypes (58.92% accuracy) or for geno-groups (81.00% accuracy). However, when a locus with increased heterogeneity was tested (D18S51), PCA-based prediction accuracy rates improved to rates similar to those obtained using LDA (45.10% and 63.46%, respectively). This study provides foundational data documenting the performance of prediction modeling for STR genotyping based on qPCR-HRM data. In order to expand the forensic applicability of this HRM assay, the method could be tested with a more commonly utilized qPCR platform.
- Open Access
An Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage
Although guidelines exist for identifying mixtures, these measures often occur at the end-point of analysis and are protracted. To facilitate early mixture detection, we integrated a high-resolution melt (HRM) mixture screening assay into the qPCR step of the forensic workflow, producing the integrated QuantifilerTM Trio-HRM assay. The assay, when coupled with a prediction tool, allowed for 75.0% accurate identification of the contributor status of a sample (single source vs. mixture). To elucidate the limitations of the developed qPCR-HRM assay, developmental validation studies were conducted assessing the reproducibility and samples with varying DNA ratios, contributors, and quality. From this work, it was determined that the integrated QuantifilerTM Trio-HRM assay is capable of accurately identifying mixtures with up to five contributors and mixtures at ratios up to 1:100. Further, the optimal performance concentration range was found to be between 0.025 and 0.5 ng/µL. With these results, evidentiary-like DNA samples were then analyzed, resulting in 100.0% of the mixture samples being accurately identified; furthermore, every time a sample was predicted as a single source, it was true, giving confidence to any single-source calls. Overall, the integrated QuantifilerTM Trio-HRM assay has exhibited an enhanced ability to discern mixture samples from single-source samples at the qPCR stage under commonly observed conditions regardless of the contributor’s sex.
Open AccessAn Assessment of the Performance Limitations of the Integrated QuantifilerTM Trio-HRM Assay: A Forensic Tool Designed to Identify Mixtures at the Quantification Stage
Although guidelines exist for identifying mixtures, these measures often occur at the end-point of analysis and are protracted. To facilitate early mixture detection, we integrated a high-resolution melt (HRM) mixture screening assay into the qPCR step of the forensic workflow, producing the integrated QuantifilerTM Trio-HRM assay. The assay, when coupled with a prediction tool, allowed for 75.0% accurate identification of the contributor status of a sample (single source vs. mixture). To elucidate the limitations of the developed qPCR-HRM assay, developmental validation studies were conducted assessing the reproducibility and samples with varying DNA ratios, contributors, and quality. From this work, it was determined that the integrated QuantifilerTM Trio-HRM assay is capable of accurately identifying mixtures with up to five contributors and mixtures at ratios up to 1:100. Further, the optimal performance concentration range was found to be between 0.025 and 0.5 ng/µL. With these results, evidentiary-like DNA samples were then analyzed, resulting in 100.0% of the mixture samples being accurately identified; furthermore, every time a sample was predicted as a single source, it was true, giving confidence to any single-source calls. Overall, the integrated QuantifilerTM Trio-HRM assay has exhibited an enhanced ability to discern mixture samples from single-source samples at the qPCR stage under commonly observed conditions regardless of the contributor’s sex.
- 8 August 2023
- Published by Springer Nature in International journal of legal medicine
- Vol. 137 (6) , 1639-1651
A quantifiler™ trio-based HRM screening assay for the accurate prediction of single source versus mixed biological samples
At present, the forensic DNA workflow is not capable of providing information about the contributor status (single source vs. multiple contributors) of evidentiary samples prior to end-point analysis. This exacerbates the challenges inherent to mixtures and low-template DNA samples. If additional sample information could be provided earlier in the workflow, protocols could be implemented to mitigate these challenges. An integrated Quantiplex®- high resolution melt (HRM) assay was shown to be effective in distinguishing between single source and mixture DNA samples; however, integration of the HRM assay into a more commonly used chemistry would be beneficial to the practitioner community. Thus, the assay was redesigned as an integrated Quantifiler™ Trio-HRM assay, which included the identification of a new DNA-binding dye, an increased reaction volume, and the establishment of new data analysis and standard curve metrics for all targets. This redesigned assay produced quantification values and qualitative values that were comparable to those produced when the same samples were tested using the standard Quantifiler™ Trio chemistry and settings. Further, STR profiles generated with quantification values produced from the integrated Quantifiler™ Trio-HRM assay and standard Quantifiler™ Trio chemistry were complete and fully concordant. Most importantly, the integrated Quantifiler™ Trio-HRM assay was able to accurately predict whether a sample was single source or a mixture 79.2% of the time, demonstrating the potential of this approach. With the incorporation of an expanded training set for prediction modeling, and completion of critical developmental validation studies, this assay could prove useful to the forensic DNA practitioner community.
- 8 August 2023
- Published by Springer Nature in International journal of legal medicine
- Vol. 137 (6) , 1639-1651
A quantifiler™ trio-based HRM screening assay for the accurate prediction of single source versus mixed biological samples
At present, the forensic DNA workflow is not capable of providing information about the contributor status (single source vs. multiple contributors) of evidentiary samples prior to end-point analysis. This exacerbates the challenges inherent to mixtures and low-template DNA samples. If additional sample information could be provided earlier in the workflow, protocols could be implemented to mitigate these challenges. An integrated Quantiplex®- high resolution melt (HRM) assay was shown to be effective in distinguishing between single source and mixture DNA samples; however, integration of the HRM assay into a more commonly used chemistry would be beneficial to the practitioner community. Thus, the assay was redesigned as an integrated Quantifiler™ Trio-HRM assay, which included the identification of a new DNA-binding dye, an increased reaction volume, and the establishment of new data analysis and standard curve metrics for all targets. This redesigned assay produced quantification values and qualitative values that were comparable to those produced when the same samples were tested using the standard Quantifiler™ Trio chemistry and settings. Further, STR profiles generated with quantification values produced from the integrated Quantifiler™ Trio-HRM assay and standard Quantifiler™ Trio chemistry were complete and fully concordant. Most importantly, the integrated Quantifiler™ Trio-HRM assay was able to accurately predict whether a sample was single source or a mixture 79.2% of the time, demonstrating the potential of this approach. With the incorporation of an expanded training set for prediction modeling, and completion of critical developmental validation studies, this assay could prove useful to the forensic DNA practitioner community.
- 24 February 2021
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (4) , 1427-1434
Comparison of DNA typing success in compromised blood and touch samples based on sampling swab composition
Sample collection at the crime scene can introduce variations in DNA recovery based upon the substrate from which a sample is collected, the material of the collection device used, or the storage conditions after collection. There are many factors during this process that can degrade the sample during drying and storage, and before DNA extraction can be performed. The purpose of this study was to evaluate and compare the performance of standard cotton swab collection with the Bode BioSafe® swab, which includes both a desiccant at the swab head and proprietary compounds to prevent degradation of the sample during sample collection and preservation. Blood and touch DNA samples were collected from porous and nonporous substrates and stored at elevated temperatures to simulate accelerated time. DNA quantification and STR profile data were used to assess the performance of the swabs. BioSafe® swab collection resulted in similar DNA yields from blood samples and significantly higher DNA yields from touch samples when compared to collection with cotton swabs. BioSafe® swabs also resulted in higher DNA integrity during long‐term storage, increased STR profile success and improved retention of low‐level contributor alleles.
- 24 February 2021
- Published by Wiley in Journal of Forensic Sciences
- Vol. 66 (4) , 1427-1434
Comparison of DNA typing success in compromised blood and touch samples based on sampling swab composition
Sample collection at the crime scene can introduce variations in DNA recovery based upon the substrate from which a sample is collected, the material of the collection device used, or the storage conditions after collection. There are many factors during this process that can degrade the sample during drying and storage, and before DNA extraction can be performed. The purpose of this study was to evaluate and compare the performance of standard cotton swab collection with the Bode BioSafe® swab, which includes both a desiccant at the swab head and proprietary compounds to prevent degradation of the sample during sample collection and preservation. Blood and touch DNA samples were collected from porous and nonporous substrates and stored at elevated temperatures to simulate accelerated time. DNA quantification and STR profile data were used to assess the performance of the swabs. BioSafe® swab collection resulted in similar DNA yields from blood samples and significantly higher DNA yields from touch samples when compared to collection with cotton swabs. BioSafe® swabs also resulted in higher DNA integrity during long‐term storage, increased STR profile success and improved retention of low‐level contributor alleles.