Shan Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shan Xing has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Keliang Shi
Lanzhou University
6 shared publicationsChenyang Peng
Lanzhou University
5 shared publicationsXiaolin Hou
Lanzhou University
5 shared publicationsFeng Zhang
Lanzhou University
4 shared publicationsYiman Lu
Lanzhou University
4 shared publicationsHao Wang
Lanzhou University
3 shared publications
Latest Publications
- 17 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Overcoming Ru-99 Isobaric Overlap via C2H4 as a Reaction Gas for Tc-99 Accurate Measurement in Large-Volume Seawater Samples by Triple Quadrupole ICP−MS with Mass-Shift Mode
Accurate determination of ultra-trace level 99Tc in environmental samples is primarily hindered by the interferences of 98Mo and 99Ru. For the “elimination” of the 99Ru isobaric overlap during the mass spectrometry measurement, the commonly-used method of mathematical correction based on a known isotopic ratio of Ru (e.g., 99Ru/102Ru) could lead to a high measurement uncertainty of 99Tc. In this work, a direct and accurate analytical method of 99Tc in large-volume seawater samples (>20 L) was developed using two TEVA resin columns in combination with ICP−MS/MS in He−C2H4 mode. Both Fe(OH)2 and Ti(OH)3 were used as co-precipitants for the pre-concentration of 99Tc in large-volume seawater samples, and then, 99Tc was purified by two serial TEVA resin columns with the high decontamination factors of Mo (5×105) and Ru (1×105). Based on the high reactivity of C2H4, the residual interferences of 98Mo and 99Ru were completely removed in the mass-shift mode for the first time. Excellent decontamination factors of 98Mo (1×1012) and 99Ru (1.6×109) were achieved in the whole procedure, which was 3−4 orders of magnitude higher than these of traditional methods. The detection limit of 0.015 pg/L for 99Tc was obtained, and the whole analysis time was less than 20 h per sample. This method is expected to directly and accurately measure ultra-trace level 99Tc in large-volume seawater samples without any mathematical correction of 99Ru.
- 17 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Overcoming Ru-99 Isobaric Overlap via C2H4 as a Reaction Gas for Tc-99 Accurate Measurement in Large-Volume Seawater Samples by Triple Quadrupole ICP−MS with Mass-Shift Mode
Accurate determination of ultra-trace level 99Tc in environmental samples is primarily hindered by the interferences of 98Mo and 99Ru. For the “elimination” of the 99Ru isobaric overlap during the mass spectrometry measurement, the commonly-used method of mathematical correction based on a known isotopic ratio of Ru (e.g., 99Ru/102Ru) could lead to a high measurement uncertainty of 99Tc. In this work, a direct and accurate analytical method of 99Tc in large-volume seawater samples (>20 L) was developed using two TEVA resin columns in combination with ICP−MS/MS in He−C2H4 mode. Both Fe(OH)2 and Ti(OH)3 were used as co-precipitants for the pre-concentration of 99Tc in large-volume seawater samples, and then, 99Tc was purified by two serial TEVA resin columns with the high decontamination factors of Mo (5×105) and Ru (1×105). Based on the high reactivity of C2H4, the residual interferences of 98Mo and 99Ru were completely removed in the mass-shift mode for the first time. Excellent decontamination factors of 98Mo (1×1012) and 99Ru (1.6×109) were achieved in the whole procedure, which was 3−4 orders of magnitude higher than these of traditional methods. The detection limit of 0.015 pg/L for 99Tc was obtained, and the whole analysis time was less than 20 h per sample. This method is expected to directly and accurately measure ultra-trace level 99Tc in large-volume seawater samples without any mathematical correction of 99Ru.
- 9 August 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1374, 344526
Determination of 99Tc in TBP phase in spent nuclear fuel reprocessing with plastic scintillation resin
- 9 August 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1374, 344526
Determination of 99Tc in TBP phase in spent nuclear fuel reprocessing with plastic scintillation resin
- 3 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (30) , 16338-16345
C2H4 as a Novel Reaction Gas for Eliminating 238U Isobaric Interference in Ultratrace Plutonium Isotope (238Pu, 239Pu, 240Pu, and 241Pu) Measurement by ICP-MS/MS
Accurate determination of ultratrace plutonium isotopes (238Pu, 239Pu, 240Pu, and 241Pu) generally requires the utilization of multiple techniques. Among them, alpha spectrometry is the only way to measure ultratrace 238Pu (238Pu, 239Pu, 240Pu, and 241Pu) in the same run was developed by ICP-MS/MS in He-C2H4 mode combined with a TK200 resin column. A high decontamination factor (DF) of 238U (1.81 × 109) was achieved by only a single TK200 resin column. 238U and its polyatomic ions (238U1H+ and 238U1H2+) can be further eliminated using C2H4 as a reaction gas with a DF(238U) of 6.63 × 105, and the overall removal efficiency of 238U reached 1.21 × 1015. The excellent measurement sensitivity of plutonium (5602 cps/(pg/g)) was achieved. Meanwhile, the investigation on the mechanism of the C2H4 reaction by DFT calculations could provide a novel method for the better understanding of the improvement of Pu sensitivity and the elimination of 238U interference. The detection limits for all plutonium isotopes were subfemtogram level, demonstrating the feasibility of ICP-MS/MS using C2H4 for the accurate determination of ultralow-level plutonium isotopes containing subgram level 238U. This method could be expected to replace alpha spectrometry for ultratrace 238Pu routine analysis.
- 3 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (30) , 16338-16345
C2H4 as a Novel Reaction Gas for Eliminating 238U Isobaric Interference in Ultratrace Plutonium Isotope (238Pu, 239Pu, 240Pu, and 241Pu) Measurement by ICP-MS/MS
Accurate determination of ultratrace plutonium isotopes (238Pu, 239Pu, 240Pu, and 241Pu) generally requires the utilization of multiple techniques. Among them, alpha spectrometry is the only way to measure ultratrace 238Pu (238Pu, 239Pu, 240Pu, and 241Pu) in the same run was developed by ICP-MS/MS in He-C2H4 mode combined with a TK200 resin column. A high decontamination factor (DF) of 238U (1.81 × 109) was achieved by only a single TK200 resin column. 238U and its polyatomic ions (238U1H+ and 238U1H2+) can be further eliminated using C2H4 as a reaction gas with a DF(238U) of 6.63 × 105, and the overall removal efficiency of 238U reached 1.21 × 1015. The excellent measurement sensitivity of plutonium (5602 cps/(pg/g)) was achieved. Meanwhile, the investigation on the mechanism of the C2H4 reaction by DFT calculations could provide a novel method for the better understanding of the improvement of Pu sensitivity and the elimination of 238U interference. The detection limits for all plutonium isotopes were subfemtogram level, demonstrating the feasibility of ICP-MS/MS using C2H4 for the accurate determination of ultralow-level plutonium isotopes containing subgram level 238U. This method could be expected to replace alpha spectrometry for ultratrace 238Pu routine analysis.
- 21 February 2024
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 274, 107400
Level, distribution and sources of Np, Pu and Am isotopes in Peter the Great Bay of Japan sea
- 21 February 2024
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 274, 107400
Level, distribution and sources of Np, Pu and Am isotopes in Peter the Great Bay of Japan sea
- 30 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2514-2523
Simultaneous Determination of Transuranium Radionuclides in Urine by Tandem Quadrupole ICP–MS/MS with Mass-Shift Mode Combined with Chemical Separation
The urine bioassay method for transuranium nuclides (237Np, 239,240,241Pu, 241Am, and 244Cm) is needed to quickly assess the potential internal contamination in emergency situations. However, in the case that the analysis of multiple radionuclides is required in the same sample, time-consuming/tedious sequential analytical procedures using multiple chromatographic separation resins would have to be employed for the separation of every single radionuclide. In this work, a rapid method for the simultaneous determination of transuranium nuclides in urine was developed by using triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) combined with a single DGA resin column. The chemical behaviors of Np/Pu and Am/Cm on the DGA resin were consistent in 8-10 mol/L HNO3 and 0.005-0.02 mol/L NaNO2 when 242Pu and 243Am were selected as tracers for Np/Pu and Am/Cm yield monitoring. Based on their different reaction rates with O2, 237Np, 239,240,241Pu, 241Am, and 244Cm in the same solution were simultaneously measured by ICP-MS/MS in the same run. The elimination efficiency of 238U+ tailing (7.43 × 10-9), 238U1H16O2+/238U16O2+ (8.11 × 10-8) and cross contamination of 241Pu and 241Am (2 even if the eluate was directly measured without any evaporation. The detection limits of transuranium nuclides were at the femtogram level, demonstrating the feasibility of ICP-MS/MS for simultaneous transuranic radionuclides urinalysis. The developed method was validated by analyzing the spiked urine samples.
- 30 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2514-2523
Simultaneous Determination of Transuranium Radionuclides in Urine by Tandem Quadrupole ICP–MS/MS with Mass-Shift Mode Combined with Chemical Separation
The urine bioassay method for transuranium nuclides (237Np, 239,240,241Pu, 241Am, and 244Cm) is needed to quickly assess the potential internal contamination in emergency situations. However, in the case that the analysis of multiple radionuclides is required in the same sample, time-consuming/tedious sequential analytical procedures using multiple chromatographic separation resins would have to be employed for the separation of every single radionuclide. In this work, a rapid method for the simultaneous determination of transuranium nuclides in urine was developed by using triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) combined with a single DGA resin column. The chemical behaviors of Np/Pu and Am/Cm on the DGA resin were consistent in 8-10 mol/L HNO3 and 0.005-0.02 mol/L NaNO2 when 242Pu and 243Am were selected as tracers for Np/Pu and Am/Cm yield monitoring. Based on their different reaction rates with O2, 237Np, 239,240,241Pu, 241Am, and 244Cm in the same solution were simultaneously measured by ICP-MS/MS in the same run. The elimination efficiency of 238U+ tailing (7.43 × 10-9), 238U1H16O2+/238U16O2+ (8.11 × 10-8) and cross contamination of 241Pu and 241Am (2 even if the eluate was directly measured without any evaporation. The detection limits of transuranium nuclides were at the femtogram level, demonstrating the feasibility of ICP-MS/MS for simultaneous transuranic radionuclides urinalysis. The developed method was validated by analyzing the spiked urine samples.
- 27 June 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 251-252, 106954
Rapid determination of 99Tc in water samples using Ti(OH)3-TcO2 co-precipitation and TK200 resin by liquid scintillation counting
- 27 June 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 251-252, 106954
Rapid determination of 99Tc in water samples using Ti(OH)3-TcO2 co-precipitation and TK200 resin by liquid scintillation counting
- 1 August 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (10) , 2027-2034
Rapid determination of uranium isotopes in calcium fluoride sludge by tandem quadrupole ICP-MS/MS
A rapid, novel and sensitive method was developed for the determination of uranium isotopes in CaF2sludge by using lithium metaborate fusion and ICP-MS/MS under He mode. This technology could be useful for treatment of radionuclide contaminated nuclear industry waste.
- 1 August 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (10) , 2027-2034
Rapid determination of uranium isotopes in calcium fluoride sludge by tandem quadrupole ICP-MS/MS
A rapid, novel and sensitive method was developed for the determination of uranium isotopes in CaF2sludge by using lithium metaborate fusion and ICP-MS/MS under He mode. This technology could be useful for treatment of radionuclide contaminated nuclear industry waste.
- 5 May 2015
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (11) , 6691-6700
Iodine-129 in Snow and Seawater in the Antarctic: Level and Source
Anthropogenic 129I has been released to the environment in different ways and chemical species by human nuclear activities since the 1940s. These sources provide ideal tools to trace the dispersion of volatile pollutants in the atmosphere. Snow and seawater samples collected in Bellingshausen, Amundsen, and Ross Seas in Antarctica in 2011 were analyzed for 129I and 127I, including organic forms; it was observed that 129I/127I atomic ratios in the Antarctic surface seawater ((6.1–13) × 10–12) are about 2 orders of magnitude lower than those in the Antarctic snow ((6.8–9.5) × 10–10), but 4–6 times higher than the prenuclear level (1.5 × 10–12), indicating a predominantly anthropogenic source of 129I in the Antarctic environment. The 129I level in snow in Antarctica is 2–4 orders of magnitude lower than that in the Northern Hemisphere, but is not significantly higher than that observed in other sites in the Southern Hemisphere. This feature indicates that 129I in Antarctic snow mainly originates from atmospheric nuclear weapons testing from 1945 to 1980; resuspension and re-emission of the fallout 129I in the Southern Hemisphere maintains the 129I level in the Antarctic atmosphere. 129I directly released to the atmosphere and re-emitted marine discharged 129I from reprocessing plants in Europe might not significantly disperse to Antarctica.
- 5 May 2015
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (11) , 6691-6700
Iodine-129 in Snow and Seawater in the Antarctic: Level and Source
Anthropogenic 129I has been released to the environment in different ways and chemical species by human nuclear activities since the 1940s. These sources provide ideal tools to trace the dispersion of volatile pollutants in the atmosphere. Snow and seawater samples collected in Bellingshausen, Amundsen, and Ross Seas in Antarctica in 2011 were analyzed for 129I and 127I, including organic forms; it was observed that 129I/127I atomic ratios in the Antarctic surface seawater ((6.1–13) × 10–12) are about 2 orders of magnitude lower than those in the Antarctic snow ((6.8–9.5) × 10–10), but 4–6 times higher than the prenuclear level (1.5 × 10–12), indicating a predominantly anthropogenic source of 129I in the Antarctic environment. The 129I level in snow in Antarctica is 2–4 orders of magnitude lower than that in the Northern Hemisphere, but is not significantly higher than that observed in other sites in the Southern Hemisphere. This feature indicates that 129I in Antarctic snow mainly originates from atmospheric nuclear weapons testing from 1945 to 1980; resuspension and re-emission of the fallout 129I in the Southern Hemisphere maintains the 129I level in the Antarctic atmosphere. 129I directly released to the atmosphere and re-emitted marine discharged 129I from reprocessing plants in Europe might not significantly disperse to Antarctica.