MGMadhawa Horana Gamage

Madhawa Horana Gamage

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Madhawa Horana Gamage has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Validation of PHITS-Predicted Neutron Moderation and Transport Driven by 1H(7Li,n)7Be Inverse-Kinematics Reaction

    by Toshiro Sakabe, Madhawa Horana Gamage, Yu Fujiwara, Shunsuke Ikeda, Takeshi Kanesue, Antonino Cannavo, Kazumasa Takahashi, Masahiro Okamura

    The inverse-kinematics 1H(7Li,n)7Be reaction provides forward-directed neutrons and is a promising candidate for accelerator-based boron neutron capture therapy (BNCT) neutron sources. Reliable moderator design for this neutron source requires experimental validation of Monte Carlo calculations. The present study aims to evaluate the predictive capability of PHITS for neutron moderation and transport toward future BNCT BSA design. In this study, a moderator assembly consisting of low-carbon steel, polyethylene, and graphite blocks was irradiated with neutrons produced by a 16.5 MeV 7Li3+ beam incident on a 12 μm-thick polypropylene target at the Tandem Van de Graff facility at Brookhaven National Laboratory. The neutron response downstream of the assembly was measured using a cylindrical BF3 neutron detector and compared with 10B(n,[[EQUATION]])7Li reaction rates calculated using PHITS Monte Carlo simulation. Cross-section data for the Inverse-kinematics reaction, generated from ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE, were separately applied to evaluate nuclear-data dependence. This study also investigates the effects of thermal neutron scattering law (TSL) data for polyethylene and graphite in the simulations. As a result, when TSL data were applied to polyethylene and graphite in the moderator assemblies, the calculated and measured reaction rates showed reasonable overall agreement, with C/E values ranging from 0.65 to 0.96 across all IK-Frag datasets. These results provide experimental support for the PHITS framework for predicting moderated neutrons and its application to future moderator and beam-shaping design for inverse-kinematics accelerator-based BNCT neutron sources.

  • Open Access

    Overcoming the Space-Charge Brightness Barrier for Fully Stripped Heavy Ions by Direct Plasma Injection

    by Madhawa Horana Gamage, Masahiro Okamura, Antonino Cannavo, Kazumasa Takahashi, Shunsuke Ikeda, Takeshi Kanesue, Shota Ikeda, Chuan Zhang, Sergey Kondrashev, Giovanni Ceccio, et al.

    SUMMARY Space-charge forces during low-energy transport have long held highly charged heavy-ion beams orders of magnitude below proton-injector currents. Here we overcome this brightness barrier by direct plasma injection. A laser-produced plasma, radially confined by a solenoid field while expanding freely along the beam axis, is fed into a radio-frequency quadrupole without a conventional low-energy transport line. Fully stripped Li3+ and C6+ reach peak accelerated currents of 148 mA and 135 mA at 320 keV/u — to our knowledge the first to match the proton-injector class. The measured currents agree with space-charge-dominated simulations and are insensitive to further increases in injected current: the limit now lies in the accelerator, not the source. Transporting a quasi-neutral plasma rather than a charged-particle beam thus shifts the current limit from source to accelerator. Independent RF beam-loading measurements confirm these currents. These beams reach a regime relevant to FLASH radiotherapy and boron neutron capture therapy.

  • Open Access

    Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

    by T. Sakabe, S. MacLeod, Y. Fujiwara, M. Horana Gamage, S. Ikeda, T. Kanesue, A. Cannavo, K. Takahashi, G. Ceccio, M. Okamura

    The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

  • Open Access

    Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

    by M. Horana Gamage, G. Garty, A. Cannavo, S. Ikeda, T. Kanesue, T. Sakabe, S. Kondrashev, M. Okamura, G. Ceccio, K. Takahashi

    We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.


  • Open Access

    Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

    by Shota Ikeda, Shunsuke Ikeda, Takeshi Kanesue, Toshiro Sakabe, Antonino Cannavo, Masahiro Okamura, Kazumasa Takahashi, Chuan Zhang, Masashi Masuoka, Horana Gamage Madhawa

  • Open Access

    Machine learning enabled measurements of astrophysical ( p,n ) reactions with the SECAR recoil separator

    by P. Tsintari, N. Dimitrakopoulos, R. Garg, K. Hermansen, C. Marshall, F. Montes, G. Perdikakis, H. Schatz, K. Setoodehnia, H. Arora, et al.

    The synthesis of heavy elements in supernovae is affected by low-energy ( n , p ) and ( p , n ) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a novel approach that integrates machine learning with ion-optical simulations to find an ion-optical solution for the separator that enables the measurement of ( p , n ) reactions, despite the reaction leaving the mass of the nucleus nearly unchanged. A new measurement of the Fe 58 ( p , n ) Co 58 reaction in inverse kinematics with a 3.66 ± 0.12 MeV/nucleon Fe 58 beam (corresponding to 3.69 ± 0.12 MeV proton energy in normal kinematics) yielded a cross-section of 20.3 ± 6.3 mb and served as a proof of principle experiment for the new technique demonstrating its effectiveness in achieving the required performance criteria. This novel approach paves the way for studying astrophysically important ( p , n ) reactions on unstable nuclei produced at FRIB.


  • First direct Be7 electron-capture Q -value measurement toward high-precision searches for neutrino physics beyond the Standard Model

    by R. Bhandari, G. Bollen, T. Brunner, N. D. Gamage, A. Hamaker, Z. Hockenbery, M. Horana Gamage, D. K. Keblbeck, K. G. Leach, D. Puentes, et al.

    We report the first direct measurement of the nuclear electron-capture (EC) decay Q value of Be7→Li7 via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable Be+7 samples. With a measured value of QEC=861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the Be7 EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using Be7-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.


  • Open Access

    Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

    by Matthew Redshaw, Ramesh Bhandari, Nadeesha Gamage, Mehedi Hasan, Madhawa Horana Gamage, Dakota K. Keblbeck, Savannah Limarenko, Dilanka Perera

    Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (∼1 part in 1011 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.


  • Updated evaluation of potential ultralow Q -value β -decay candidates

    by D. K. Keblbeck, R. Bhandari, N. D. Gamage, M. Horana Gamage, K. G. Leach, X. Mougeot, M. Redshaw

    “Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β-decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. The relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.


  • Identification of a potential ultralow- Q -value electron-capture decay branch in Se75 via a precise Penning trap measurement of the mass of As75

    by M. Horana Gamage, R. Bhandari, G. Bollen, N. D. Gamage, A. Hamaker, D. Puentes, M. Redshaw, R. Ringle, S. Schwarz, C. S. Sumithrarachchi, et al.

    Background: Low-energy β and electron-capture (EC) decays are important systems in neutrino mass determination experiments. An isotope with an ultralow-Q-value β decay to an excited state in the daughter with Qes<1 keV could provide a promising alternative candidate for future experiments. Se75 EC decay and Ge75β decay represent such candidates, but a more precise determination of the mass of the common daughter, As75, is required to evaluate whether their potential decay branches are energetically allowed and ultralow.