Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Young Seung Lee has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Loop-Type Field Probe to Measure Human Body Exposure to 5G Millimeter-Wave Base Stations

    by DukSoo Kwon, Young Seung Lee, Chang-Hee Hyoung, Jung-Hwan Hwang, Hyung-Do Choi

    This paper proposes a field probe to measure the power density (PD) at a millimeter-wave (mmWave) frequency band. The proposed probe is composed of a loop antenna in which one end is terminated with a load resistor. Such a structure enables the simultaneous measurement of electric (E)- and magnetic (H)-fields: the E-field is measured at a gap where the load resistor is placed, and the H-field is measured through the loop antenna. The simultaneous measurement makes it possible to measure PD for an incident wave even in the near field region where the E- and H-fields have different phases from each other. The proposed probe is fabricated and evaluated for its PD measurement performance. The measurement results show that the probe measures PD with an error less than 1.3 dB. Owing to the near field measurement, the proposed probe is useful in measuring the human body exposure to electromagnetic fields (EMFs) that are generated by 5G mmWave base stations.


  • Open Access

    An In Vitro Experimental System for 5G 3.5 GHz Exposures

    by Young Seung Lee, Sang Bong Jeon, Jeong-Ki Pack, Nam Kim, Hyung-Do Choi

    In this study, an in vitro experimental system is developed for fifth-generation (5G) 3.5 GHz exposures. A radial transmission line (RTL) housed in an incubator can support the single-mode propagation at a 3.5 GHz band. A conical antenna is also placed at the center of an RTL to ensure field symmetries. A 5G signal generator along with a customized power amplifier can create 5G new radio time division duplex (TDD) waveforms. Additionally, a feedback scheme implemented by employing a directional coupler and power meter allows power control to ensure a steady output power. The system is evaluated based on temperature measurements using the initial temperature slope and nonlinear curve fitting to determine the specific absorption rate (SAR) values. Comparing SARs obtained from a “worst-case” signal of a maximum power condition with the values obtained from a “TDD” signal of an actual 5G TDD transmission gives the initial slope ratio of 0.741, which is very similar to the theoretical duty cycle of 0.743. It is also shown that the average output power, water temperature, incubator air temperature, and CO2 density are adequately controlled for appropriate in vitro experiments.


  • Open Access

    5G Electromagnetic Radiation Attenuates Skin Melanogenesis In Vitro by Suppressing ROS Generation

    by Kyuri Kim, Young Seung Lee, Nam Kim, Hyung-Do Choi, Kyung-Min Lim

    Recently, the impacts of 5G electromagnetic radiation (EMR) with 28 GHz on human health have been attracting public attention with the advent of 5G wireless communication. Here, we report that 5G (28 GHz) EMR can attenuate the skin pigmentation in murine melanoma cells (B16F10) and a 3D pigmented human epidermis model (Melanoderm™). B16 cells were exposed to 5G (28 GHz) with or without α-MSH for 4 h per day. Interestingly, 5G attenuated α-MSH-induced melanin synthesis. Fontana–Masson staining confirmed that the dendritic formation of α-MSH stimulated B16 cells was diminished by 5G exposure. To confirm the anti-melanogenic effect of 5G EMR, MelanoDerm™ was irradiated with 5G at a power intensity of 10 W/m2 for 4 h a day for 16 days and melanin distribution was detected with Fontana–Masson staining, which supported the anti-melanogenic effect of 5G EMR. Consistently, 5G EMR suppressed α-MSH induced upregulation of melanogenic enzymes; tyrosinase, TRP-1, and TRP-2. Of note, 5G EMR attenuated ROS production stimulated by α-MSH and H2O2, suggesting that 5G EMR may dissipate ROS generation, which is pivotal for the melanin synthesis. Collectively, we demonstrated that 5G EMR can attenuate skin pigmentation by attenuating ROS generation.


  • Open Access

    Study on the Appropriate Measurement Spacing for EMF Installation Compliance Assessments of a 3.5 GHz 5G Base Station

    by Young Seung Lee, Sang Bong Jeon, Ae-Kyoung Lee, Kihwea Kim, Jeong-Ki Pack, Hyung-Do Choi

    The number of fifth generation (5G) base stations (BSs) installed for commercial services continues to increase in South Korea since the first 5G rollout of the 3.5 GHz band in 2019. However, this will cause a rapid increase in the cost and effort required for an electromagnetic field (EMF) installation compliance measurements of a 5G BS. This paper studies an appropriate measurement spacing for EMF installation compliance assessments of a 3.5 GHz 5G BS. Ray-tracing simulations based on the ray frustum technique are performed for three installation scenarios according to the accessibility categories provided in the International Telecommunication Union-T K.52 recommendation to observe the power density exposure trends. An interference analysis using the two-ray propagation model indicates that the spacing of 1 m can be suitable for the installation compliance of a 5G BS above 3 GHz. In addition, it was found that this spacing could be also applied up to the higher frequency of 7.125 GHz, the upper limit of Frequency Range 1 defined in the 3rd Generation Partnership Project specification. Measurements based on two different 5G signal extrapolations using the Synchronization Signal Block were conducted to validate the spacing of 1 m for a 3.5 GHz 5G BS established by simulation studies.


  • Open Access

    Effects of Electromagnetic Waves with LTE and 5G Bandwidth on the Skin Pigmentation In Vitro

    by Kyuri Kim, Young Seung Lee, Nam Kim, Hyung-Do Choi, Dong-Jun Kang, Hak Rim Kim, Kyung-Min Lim

    With the rapid growth of wireless communication devices, the influences of electromagnetic fields (EMF) on human health are gathering increasing attention. Since the skin is the largest organ of the body and is located at the outermost layer, it is considered a major target for the health effects of EMF. Skin pigmentation represents one of the most frequent symptoms caused by various non-ionizing radiations, including ultraviolet radiation, blue light, infrared, and extremely low frequency (ELF). Here, we investigated the effects of EMFs with long-term evolution (LTE, 1.762 GHz) and 5G (28 GHz) bandwidth on skin pigmentation in vitro. Murine and Human melanoma cells (B16F10 and MNT-1) were exposed to either LTE or 5G for 4 h per day, which is considered the upper bound of average smartphone use time. It was shown that neither LTE nor 5G exposure induced significant effects on cell viability or pigmentation. The dendrites of MNT-1 were neither lengthened nor regressed after EMF exposure. Skin pigmentation effects of EMFs were further examined in the human keratinocyte cell line (MNT-1-HaCaT) co-culture system, which confirmed the absence of significant hyper-pigmentation effects of LTE and 5G EMFs. Lastly, MelanoDerm™, a 3D pigmented human epidermis model, was irradiated with LTE (1.762 GHz) or 5G (28 GHz), and image analysis and special staining were performed. No changes in the brightness of MelanoDerm™ tissues were observed in LTE- or 5G-exposed tissues, except for only minimal changes in the size of melanocytes. Collectively, these results imply that exposure to LTE and 5G EMFs may not affect melanin synthesis or skin pigmentation under normal smartphone use condition.


  • Open Access

    Implementation of an in vitro exposure system for 28 GHz

    by Young Seung Lee, Philip Ayiku Dzagbletey, Jae‐Young Chung, Sang Bong Jeon, Ae‐Kyoung Lee, Nam Kim, Seong Jong Song, Hyung‐Do Choi


  • Estimation of Power Density Radiated From Radio Base Station for Telecommunication Services

    by DukSoo Kwon, Young Seung Lee, Ae-Kyoung Lee, Hyung-Do Choi

    In this article, a simple formula for estimating the power density from a base station for a compliance assessment is proposed. One of the most popular methods for estimating the power density and achieving compliance is applying the formula provided in the ITU-T K.52 standard, which involves a plane wave ground reflection based on the Fresnel coefficient and actual antenna pattern. However, the ITU-T K.52 formula has a major drawback in that its estimation typically leads to a large overestimation of the exposure power density. Several environmental factors of an installation scenario are therefore considered to overcome this overestimation, and the pseudo reflection coefficient is defined based on the maximum power density. The proposed formula is verified herein by comparing the estimation results with the ray tracing computations.

  • Proposal of 28 GHz In Vitro Exposure System Based on Field Uniformity for Three‐Dimensional Cell Culture Experiments

    by Young Seung Lee, Jae‐Young Chung, Sang Bong Jeon, Ae‐Kyoung Lee, Hyung‐Do Choi

    This paper proposes a novel in vitro exposure system operating at millimeter‐wave (mmWave) 28 GHz, one of the frequency bands under consideration for fifth generation (5G) communication. We employed the field uniformity concept along cross‐sectional observation planes at shorter distances from the radiation antenna for better efficiency and a small‐size system. A choke‐ring antenna was designed for this purpose in consideration of a wider beamwidth (BW) and a symmetric far‐field pattern across three principal planes. The permittivity of Dulbecco's modified Eagle's medium solution was measured to examine the specific absorption rate (SAR) of the skin cell layer inside a Petri dish model for a three‐dimensional (3D) cell culture in vitro experiment. The best deployment of Petri dishes, taking into account a geometrical field symmetry, was proposed. Local SAR values within the cell layer among the Petri dishes were determined with different polarization angles. It was determined that this polarization effect should be considered when the actual exposure and deployment were conducted. We finally proposed an in vitro exposure system based on the field uniformity including downward exposure from an antenna for 3D cell culture experiments. A small‐size chamber system was obtained, and the size was estimated using the planar near‐field chamber design rule. Bioelectromagnetics. 2019;40:445–457. © 2019 Bioelectromagnetics Society