DukSoo Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
DukSoo Kwon has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hyung-Do Choi
Radio and Broadcasting Technology Laboratory, ETRI, Daejeon 34129, Republic of Korea
3 shared publications - Ae-Kyoung Lee
Radio Research Division, Electronics and Telecommunication Research Institute, Daejon 34129, Republic of Kore
2 shared publications - Young Seung Lee
Radio and Satellite Research Division, Electronics and Telecommunications Research Institute, Daejeon, South Korea
2 shared publications - ByungKuon Ahn
Department of Intelligent Semiconductors, School of Electronic Engineering, Soongsil University, Seoul, South Korea
1 shared publication - Chang Hee Hyoung
Electronics and Telecommunications Research Institute (ETRI)
1 shared publication - Jin-Woo Kim
School of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 22 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10286
Simultaneous 4G and 5G EMF Exposure and Field Uniformity in a Reverberation Chamber for Animal Studies
The design and validation of a reverberation chamber (RC) specifically constructed for conducting large-scale experimental animal carcinogenicity studies using RF electromagnetic fields (EMF) relevant to contemporary 4G and 5G mobile communication (900 MHz, 2.12 GHz, and 3.65 GHz) is proposed. The RC’s electric field (E-field) uniformity is evaluated under four practical loading conditions: empty, apparatus only, and two apparatus variations with 80 experimental animals (Sprague–Dawley rats) with approximate weights 400 g and 520 g, respectively. Measurement results show E-field uniformity better than 1.36 dB under all test conditions, with frequency-dependent variation becoming negligible once the RC is loaded with cage racks and 80 rats. Additionally, a predictive method is introduced to estimate composite E-field intensities under simultaneous multi-frequency exposures, potentially reducing experimental measurements. These findings confirm that the designed RC is capable of accurately evaluating RF EMF exposure in biological studies.
- 22 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10286
Open AccessSimultaneous 4G and 5G EMF Exposure and Field Uniformity in a Reverberation Chamber for Animal Studies
The design and validation of a reverberation chamber (RC) specifically constructed for conducting large-scale experimental animal carcinogenicity studies using RF electromagnetic fields (EMF) relevant to contemporary 4G and 5G mobile communication (900 MHz, 2.12 GHz, and 3.65 GHz) is proposed. The RC’s electric field (E-field) uniformity is evaluated under four practical loading conditions: empty, apparatus only, and two apparatus variations with 80 experimental animals (Sprague–Dawley rats) with approximate weights 400 g and 520 g, respectively. Measurement results show E-field uniformity better than 1.36 dB under all test conditions, with frequency-dependent variation becoming negligible once the RC is loaded with cage racks and 80 rats. Additionally, a predictive method is introduced to estimate composite E-field intensities under simultaneous multi-frequency exposures, potentially reducing experimental measurements. These findings confirm that the designed RC is capable of accurately evaluating RF EMF exposure in biological studies.
- Open Access
- 27 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11777
Loop-Type Field Probe to Measure Human Body Exposure to 5G Millimeter-Wave Base Stations
This paper proposes a field probe to measure the power density (PD) at a millimeter-wave (mmWave) frequency band. The proposed probe is composed of a loop antenna in which one end is terminated with a load resistor. Such a structure enables the simultaneous measurement of electric (E)- and magnetic (H)-fields: the E-field is measured at a gap where the load resistor is placed, and the H-field is measured through the loop antenna. The simultaneous measurement makes it possible to measure PD for an incident wave even in the near field region where the E- and H-fields have different phases from each other. The proposed probe is fabricated and evaluated for its PD measurement performance. The measurement results show that the probe measures PD with an error less than 1.3 dB. Owing to the near field measurement, the proposed probe is useful in measuring the human body exposure to electromagnetic fields (EMFs) that are generated by 5G mmWave base stations.
- 27 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11777
Open AccessLoop-Type Field Probe to Measure Human Body Exposure to 5G Millimeter-Wave Base Stations
This paper proposes a field probe to measure the power density (PD) at a millimeter-wave (mmWave) frequency band. The proposed probe is composed of a loop antenna in which one end is terminated with a load resistor. Such a structure enables the simultaneous measurement of electric (E)- and magnetic (H)-fields: the E-field is measured at a gap where the load resistor is placed, and the H-field is measured through the loop antenna. The simultaneous measurement makes it possible to measure PD for an incident wave even in the near field region where the E- and H-fields have different phases from each other. The proposed probe is fabricated and evaluated for its PD measurement performance. The measurement results show that the probe measures PD with an error less than 1.3 dB. Owing to the near field measurement, the proposed probe is useful in measuring the human body exposure to electromagnetic fields (EMFs) that are generated by 5G mmWave base stations.
- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (2) , 384-389
Estimation of Power Density Radiated From Radio Base Station for Telecommunication Services
In this article, a simple formula for estimating the power density from a base station for a compliance assessment is proposed. One of the most popular methods for estimating the power density and achieving compliance is applying the formula provided in the ITU-T K.52 standard, which involves a plane wave ground reflection based on the Fresnel coefficient and actual antenna pattern. However, the ITU-T K.52 formula has a major drawback in that its estimation typically leads to a large overestimation of the exposure power density. Several environmental factors of an installation scenario are therefore considered to overcome this overestimation, and the pseudo reflection coefficient is defined based on the maximum power density. The proposed formula is verified herein by comparing the estimation results with the ray tracing computations.
- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (2) , 384-389
Estimation of Power Density Radiated From Radio Base Station for Telecommunication Services
In this article, a simple formula for estimating the power density from a base station for a compliance assessment is proposed. One of the most popular methods for estimating the power density and achieving compliance is applying the formula provided in the ITU-T K.52 standard, which involves a plane wave ground reflection based on the Fresnel coefficient and actual antenna pattern. However, the ITU-T K.52 formula has a major drawback in that its estimation typically leads to a large overestimation of the exposure power density. Several environmental factors of an installation scenario are therefore considered to overcome this overestimation, and the pseudo reflection coefficient is defined based on the maximum power density. The proposed formula is verified herein by comparing the estimation results with the ray tracing computations.
- Open Access
- 31 July 2016
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 16 (3) , 194-197
An Eight-Element Compact Low-Profile Planar MIMO Antenna Using LC Resonance with High Isolation
- 31 July 2016
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 16 (3) , 194-197
Open AccessAn Eight-Element Compact Low-Profile Planar MIMO Antenna Using LC Resonance with High Isolation