Hiroki Morishita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroki Morishita has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
- Norikazu Mizuochi
Kyoto University
23 shared publications - Hiromitsu Kato
Quantum Information Research Center, Institute of Advanced Sciences, Yokohama National University, Hodogaya, Japan
7 shared publications - Shinji Miwa
The University of Tokyo
7 shared publications M. Fujiwara
Institute for Chemical Research, Kyoto University 1 , Gokasho, Uji, Kyoto 611-0011, Japan
6 shared publicationsS. Yamasaki
CREST, Japan Science and Technology Agency, Kawaguchi, Saitama, 332-0012, Japan
5 shared publications- Toshiharu Makino
Advanced Power Electronics Research Center, AIST, 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8568, Japan
5 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 27 (1)
Device engineering for photocurrent detected magnetic resonance and scanning probes using solid-state spin defects
- 17 August 2026
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 27 (1)
Open AccessDevice engineering for photocurrent detected magnetic resonance and scanning probes using solid-state spin defects
- 1 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (22)
Scanning photocurrent imaging resolution of single NV center in diamond
We investigated the spatial resolution of scanning photocurrent microscopy (SPhM) for imaging single nitrogen-vacancy (NV) centers in diamond in detail and compared it with that of confocal laser scanning microscopy (CLSM). While CLSM suffers from degraded spatial resolution due to fluorescence saturation, SPhM maintains a high spatial resolution despite the high-power laser excitation required. Numerical simulations of SPhM and CLSM images showed good agreement with experimental data and further indicated that SPhM achieves superior spatial resolution. Additionally, the signal-to-noise ratio of the photoelectrically detected magnetic resonance spectrum is comparable to that of the optically detected magnetic resonance spectrum in our home-made spectrometers. These findings suggest that SPhM can enhance the performance of NV-based quantum sensors.
- 1 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (22)
Scanning photocurrent imaging resolution of single NV center in diamond
We investigated the spatial resolution of scanning photocurrent microscopy (SPhM) for imaging single nitrogen-vacancy (NV) centers in diamond in detail and compared it with that of confocal laser scanning microscopy (CLSM). While CLSM suffers from degraded spatial resolution due to fluorescence saturation, SPhM maintains a high spatial resolution despite the high-power laser excitation required. Numerical simulations of SPhM and CLSM images showed good agreement with experimental data and further indicated that SPhM achieves superior spatial resolution. Additionally, the signal-to-noise ratio of the photoelectrically detected magnetic resonance spectrum is comparable to that of the optically detected magnetic resonance spectrum in our home-made spectrometers. These findings suggest that SPhM can enhance the performance of NV-based quantum sensors.
- Open Access
- 1 July 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (7) , 070903
Compact and portable pulsed measurement module using diamond NV centers
We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.
- 1 July 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (7) , 070903
Open AccessCompact and portable pulsed measurement module using diamond NV centers
We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.
- 20 March 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (3) , 034061
Spin-Dependent Dynamics of Photocarrier Generation in Electrically Detected Nitrogen-Vacancy-Based Quantum Sensing
Electrical detection of nitrogen-vacancy (N-V) centers in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors and has the potential to achieve a higher collection efficiency than that of optical techniques. However, the mechanism for the electrical detection of N-V spins is not fully understood. In this study, we observe positive contrast in photocurrent detected magnetic resonance (PDMR). Note that negative PDMR contrast is usually observed. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by N-V centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of N-V centers. Furthermore, we demonstrate ac magnetic field sensing using spin coherence with the PDMR technique. ac magnetic field measurement with the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. Here, we introduce noise suppression using a phase-cycling-based noise-canceling technique. We demonstrate electrically detected ac magnetic field sensing with a sensitivity of 29 nT . Finally, we discuss sensitivity enhancement based on the proposed model.- 20 March 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (3) , 034061
Spin-Dependent Dynamics of Photocarrier Generation in Electrically Detected Nitrogen-Vacancy-Based Quantum Sensing
Electrical detection of nitrogen-vacancy (N-V) centers in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors and has the potential to achieve a higher collection efficiency than that of optical techniques. However, the mechanism for the electrical detection of N-V spins is not fully understood. In this study, we observe positive contrast in photocurrent detected magnetic resonance (PDMR). Note that negative PDMR contrast is usually observed. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by N-V centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of N-V centers. Furthermore, we demonstrate ac magnetic field sensing using spin coherence with the PDMR technique. ac magnetic field measurement with the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. Here, we introduce noise suppression using a phase-cycling-based noise-canceling technique. We demonstrate electrically detected ac magnetic field sensing with a sensitivity of 29 nT . Finally, we discuss sensitivity enhancement based on the proposed model.- Open Access
- 13 February 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (7) , 072101
Electroluminescence of negatively charged single NV centers in diamond
The realization of electroluminescence (EL) of negatively charged nitrogen vacancy (NV−) centers is important toward all-electrical control of diamond quantum devices. In this study, we demonstrated electrical excitation and detection of EL of single NV− centers by using lateral diamond p+–i(n−)–n+ diodes. It had been grown by homoepitaxy using the plasma enhanced chemical vapor deposition technique. We introduced a lightly phosphorus doped i(n−) layer to stabilize the negative state of NV centers. It was estimated that the efficiency of the electrical excitation rate of the NV center was more than 30 times enhanced by introducing lateral diamond p+–i(n−)–n+ diodes structure compared with the previous vertical diode. Furthermore, the EL of a single NV− center embedded in the i(n−) layer region was characterized. The results show that the charge state of the single NV centers can be manipulated by the voltage applied to the p+–i(n−)–n+ diode, where the emission of EL is increasingly dominated by NV− in the range of 30 to 50 V.
- 13 February 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (7) , 072101
Open AccessElectroluminescence of negatively charged single NV centers in diamond
The realization of electroluminescence (EL) of negatively charged nitrogen vacancy (NV−) centers is important toward all-electrical control of diamond quantum devices. In this study, we demonstrated electrical excitation and detection of EL of single NV− centers by using lateral diamond p+–i(n−)–n+ diodes. It had been grown by homoepitaxy using the plasma enhanced chemical vapor deposition technique. We introduced a lightly phosphorus doped i(n−) layer to stabilize the negative state of NV centers. It was estimated that the efficiency of the electrical excitation rate of the NV center was more than 30 times enhanced by introducing lateral diamond p+–i(n−)–n+ diodes structure compared with the previous vertical diode. Furthermore, the EL of a single NV− center embedded in the i(n−) layer region was characterized. The results show that the charge state of the single NV centers can be manipulated by the voltage applied to the p+–i(n−)–n+ diode, where the emission of EL is increasingly dominated by NV− in the range of 30 to 50 V.
- 8 December 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (22) , 224501
Broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors
Quantum sensors based on nitrogen-vacancy (NV) centers in diamond are expected to demonstrate a wide variety of applications. For high-sensitivity quantum sensors with NV center ensembles, uniform manipulation of the electron spins of the NV centers in large volumes is required. In addition, a broad microwave frequency bandwidth for manipulating the NV centers' electron spin is necessary for vector magnetometry and measurement under a finite static magnetic field. Here, we demonstrate a broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors. The simulation shows that the current is distributed at both edges of the loop coil of a single copper plate due to the skin effect. The loop coil acts like a Helmholtz coil, which realizes uniformity in the z-direction of the microwave magnetic field (B1). The plate structure has a higher mechanical stability, durability, and a larger heat capacity than the Helmholtz coil, due to its large volume. The antenna achieves a higher performance than previously reported antennae, with a maximal B1 of 4.5 G, a broad bandwidth of 287 ± 6 MHz, and a peak-to-peak variation of over a 3.1 mm3 cylinder volume. These performances show that the presented antenna is suitable for manipulating solid-state spin ensembles for high-sensitivity quantum sensors.- 8 December 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (22) , 224501
Broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors
Quantum sensors based on nitrogen-vacancy (NV) centers in diamond are expected to demonstrate a wide variety of applications. For high-sensitivity quantum sensors with NV center ensembles, uniform manipulation of the electron spins of the NV centers in large volumes is required. In addition, a broad microwave frequency bandwidth for manipulating the NV centers' electron spin is necessary for vector magnetometry and measurement under a finite static magnetic field. Here, we demonstrate a broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors. The simulation shows that the current is distributed at both edges of the loop coil of a single copper plate due to the skin effect. The loop coil acts like a Helmholtz coil, which realizes uniformity in the z-direction of the microwave magnetic field (B1). The plate structure has a higher mechanical stability, durability, and a larger heat capacity than the Helmholtz coil, due to its large volume. The antenna achieves a higher performance than previously reported antennae, with a maximal B1 of 4.5 G, a broad bandwidth of 287 ± 6 MHz, and a peak-to-peak variation of over a 3.1 mm3 cylinder volume. These performances show that the presented antenna is suitable for manipulating solid-state spin ensembles for high-sensitivity quantum sensors.- 31 October 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (18) , 184005
Electrical detection of nuclear spins via silicon vacancies in silicon carbide at room temperature
Color centers in wide-bandgap semiconductors, including diamond and silicon carbide (SiC), are attractive systems for quantum information and quantum sensor devices with excellent spin properties at room temperature. In addition, nuclear spins in crystals are expected to serve as the quantum memory and to enhance the sensitivity of quantum sensors with the combination with color centers as a result of an extremely long spin coherence time. Although the spin state of both color centers and nuclear spins coupled through hyperfine interactions is usually optically read out, an electrical readout technique is important for miniaturizing and integrating devices. In the present study, we report the electrical detection of silicon vacancy (V2) centers in 4H-SiC by photocurrent-detected magnetic resonance (PDMR) using a frequency-sweep technique. We electrically observe the spin coherence of the V2 centers and clearly resolve the hyperfine splitting of the electron spin signal for the V2 centers coupled with next-nearest-neighbor 29Si atoms. In addition, we apply PDMR to electron–nuclear double resonance (PD-ENDOR) to detect nuclear magnetic resonance of 29Si at room temperature and find that this method can resolve nuclear spins coupled with neighboring electron spins in the V2 centers. The realization of PD-ENDOR is expected to be a critical step toward the development of electrically driven integrated quantum devices.
- 31 October 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (18) , 184005
Electrical detection of nuclear spins via silicon vacancies in silicon carbide at room temperature
Color centers in wide-bandgap semiconductors, including diamond and silicon carbide (SiC), are attractive systems for quantum information and quantum sensor devices with excellent spin properties at room temperature. In addition, nuclear spins in crystals are expected to serve as the quantum memory and to enhance the sensitivity of quantum sensors with the combination with color centers as a result of an extremely long spin coherence time. Although the spin state of both color centers and nuclear spins coupled through hyperfine interactions is usually optically read out, an electrical readout technique is important for miniaturizing and integrating devices. In the present study, we report the electrical detection of silicon vacancy (V2) centers in 4H-SiC by photocurrent-detected magnetic resonance (PDMR) using a frequency-sweep technique. We electrically observe the spin coherence of the V2 centers and clearly resolve the hyperfine splitting of the electron spin signal for the V2 centers coupled with next-nearest-neighbor 29Si atoms. In addition, we apply PDMR to electron–nuclear double resonance (PD-ENDOR) to detect nuclear magnetic resonance of 29Si at room temperature and find that this method can resolve nuclear spins coupled with neighboring electron spins in the V2 centers. The realization of PD-ENDOR is expected to be a critical step toward the development of electrically driven integrated quantum devices.
- 22 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Transient Analysis Of Molten Pool With Applying Axial Magnetic Field In Tig Arc Welding
In TIG arc welding, technicians use a rolling technique to ensure high quality welds. In this rolling technique, the cathode is rotated while welding. However, the rolling method is difficult and complicated. As a countermeasure, it has been proposed that a magnetic field is applied to rotate the arc. When a magnetic field is applied, it is difficult to measure the arc behavior and the convection of the molten pool. Hence, numerical methods for the arc have been developed [1] , [2] . Moreover, the arc behavior is analyzed with applying magnetic field [3] . In this paper, molten pool with applying axial magnetic field in TIG arc welding transient was analyzed. Specifically, analytical model was constructed for solid, liquid, and gas, and four forces were calculated for the molten pool. The four forces are drag force of plasma flow, shear stress of Marangoni effect, buoyancy, and electromagnetic force. As a result, a spiral flow velocity was generated in the molten pool with the application of axial magnetic field. In addition, the flow velocity of the molten pool was more affected by the axial magnetic field than that of the arc. Therefore, it was possible that transient analysis of molten pool with applying axial magnetic field in TIG arc welding.
- 22 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Transient Analysis Of Molten Pool With Applying Axial Magnetic Field In Tig Arc Welding
In TIG arc welding, technicians use a rolling technique to ensure high quality welds. In this rolling technique, the cathode is rotated while welding. However, the rolling method is difficult and complicated. As a countermeasure, it has been proposed that a magnetic field is applied to rotate the arc. When a magnetic field is applied, it is difficult to measure the arc behavior and the convection of the molten pool. Hence, numerical methods for the arc have been developed [1] , [2] . Moreover, the arc behavior is analyzed with applying magnetic field [3] . In this paper, molten pool with applying axial magnetic field in TIG arc welding transient was analyzed. Specifically, analytical model was constructed for solid, liquid, and gas, and four forces were calculated for the molten pool. The four forces are drag force of plasma flow, shear stress of Marangoni effect, buoyancy, and electromagnetic force. As a result, a spiral flow velocity was generated in the molten pool with the application of axial magnetic field. In addition, the flow velocity of the molten pool was more affected by the axial magnetic field than that of the arc. Therefore, it was possible that transient analysis of molten pool with applying axial magnetic field in TIG arc welding.
- 19 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044033
Electrical Control for Extending the Ramsey Spin Coherence Time of Ion-Implanted Nitrogen-Vacancy Centers in Diamond
The extension of spin coherence times is a crucial issue for quantum information and quantum sensing. In solid-state systems, suppressing noise through various techniques has been demonstrated. On the other hand, an electrical control for suppression is important toward individual controls of on-chip quantum-information devices. Here, we show electrical control for extension of the spin coherence times of 40-nm-deep ion-implanted single-nitrogen-vacancy center spins in diamond by suppressing magnetic noise. We apply 120 V dc across two contacts spaced by 10 μm. The spin coherence times, estimated from a free-induction decay and a Hahn-echo decay, are increased up to about 10 times (reaching 10 μs) and 1.4 times (reaching 150 μs), respectively. From the quantitative analysis, the dominant decoherence source, depending on the applied static electric field, is elucidated. Electrical control for extension can deliver a sensitivity enhancement to the dc sensing of temperature, pressure, and electric (but not magnetic) fields, opening up an alternative technique in solid-state quantum-information devices.
- 19 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044033
Electrical Control for Extending the Ramsey Spin Coherence Time of Ion-Implanted Nitrogen-Vacancy Centers in Diamond
The extension of spin coherence times is a crucial issue for quantum information and quantum sensing. In solid-state systems, suppressing noise through various techniques has been demonstrated. On the other hand, an electrical control for suppression is important toward individual controls of on-chip quantum-information devices. Here, we show electrical control for extension of the spin coherence times of 40-nm-deep ion-implanted single-nitrogen-vacancy center spins in diamond by suppressing magnetic noise. We apply 120 V dc across two contacts spaced by 10 μm. The spin coherence times, estimated from a free-induction decay and a Hahn-echo decay, are increased up to about 10 times (reaching 10 μs) and 1.4 times (reaching 150 μs), respectively. From the quantitative analysis, the dominant decoherence source, depending on the applied static electric field, is elucidated. Electrical control for extension can deliver a sensitivity enhancement to the dc sensing of temperature, pressure, and electric (but not magnetic) fields, opening up an alternative technique in solid-state quantum-information devices.
- Open Access
- 21 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
Room Temperature Electrically Detected Nuclear Spin Coherence of NV Centres in Diamond
We demonstrate electrical detection of the14N nuclear spin coherence of NV centres at room temperature. Nuclear spins are candidates for quantum memories in quantum-information devices and quantum sensors, and hence the electrical detection of nuclear spin coherence is essential to develop and integrate such quantum devices. In the present study, we used a pulsed electrically detected electron-nuclear double resonance technique to measure the Rabi oscillations and coherence time (T2) of14N nuclear spins in NV centres at room temperature. We observedT2≈ 0.9 ms at room temperature, however, this result should be taken as a lower limit due to limitations in the longitudinal relaxation time of the NV electron spins. Our results will pave the way for the development of novel electron- and nuclear-spin-based diamond quantum devices.
- 21 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
Open AccessRoom Temperature Electrically Detected Nuclear Spin Coherence of NV Centres in Diamond
We demonstrate electrical detection of the14N nuclear spin coherence of NV centres at room temperature. Nuclear spins are candidates for quantum memories in quantum-information devices and quantum sensors, and hence the electrical detection of nuclear spin coherence is essential to develop and integrate such quantum devices. In the present study, we used a pulsed electrically detected electron-nuclear double resonance technique to measure the Rabi oscillations and coherence time (T2) of14N nuclear spins in NV centres at room temperature. We observedT2≈ 0.9 ms at room temperature, however, this result should be taken as a lower limit due to limitations in the longitudinal relaxation time of the NV electron spins. Our results will pave the way for the development of novel electron- and nuclear-spin-based diamond quantum devices.