Taehoon Kim has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correction to “A 2000-Volumes/s 3-D Ultrasound Probe With Monolithically-Integrated 23 × 23-mm2 4096-Element CMUT Array”

    by Nuriel N. M. Rozsa, Zhao Chen, Taehoon Kim, Peng Guo, Yannick M. Hopf, Jason Voorneveld, Djalma Simoes dos Santos, Emile Noothout, Zu-Yao Chang, Chao Chen, et al.

    Presents corrections to the paper, Corrections to “A 2000-Volumes/s 3-D Ultrasound Probe With Monolithically-Integrated 23 × 23-mm2 4096-Element CMUT Array”.

  • Modeling and Simulation of Microwave Kinetic Inductance Detector Readout System Using Simulink and RF Blockset

    by Taehoon Kim

    Microwave Kinetic Inductance Detectors (MKIDs) represent a class of low-temperature superconducting detectors employed for observing astronomical phenomena spanning the submillimeter through visible bands. Renowned for their intrinsic frequency-division multiplexing capability at microwave frequencies, MKIDs offer the advantage of eliminating the need for complex cryogenic multiplexing electronics. However, the overall readout architecture remains complex, necessitating sophisticated room-temperature electronics. Optimizing overall performance poses a significant challenge. This paper introduces a novel approach to behavioral modeling and simulation for the MKID readout system utilizing Simulink and the RF Blockset library. The models incorporate major non-idealities of electronic components to investigate their impacts on system performance. Additionally, the model of the MKID array is included based on measured transmission data, ensuring high simulation accuracy. The simulation tool facilitates the study and high-level design of the MKID readout system before delving into hardware implementation.


  • A 2000-volumes/s 3-D Ultrasound Probe With Monolithically-Integrated 23 × 23-mm² 4096 -Element CMUT Array

    by Nuriel N. M. Rozsa, Zhao Chen, Taehoon Kim, Peng Guo, Yannick M. Hopf, Jason Voorneveld, Djalma Simoes dos Santos, Emile Noothout, Zu-Yao Chang, Chao Chen, et al.

    This article presents a 4096-element ultrasound probe for high volume-rate (HVR) cardiovascular imaging. The probe consists of two application-specific integrated circuits (ASICs), each of which interfaces with a 2048-element monolithically-integrated capacitive micro-machined ultrasound transducer (CMUT) array. The probe can image a 60$^{\circ}$ $\times$ 60$^{\circ}$ $\times$ 10-cm volume at 2000 volumes/s, the highest volume-rate with in-probe channel-count reduction reported to date. It uses 2 $\times$ 2 delay-and-sum micro-beamforming ($\mu$BF) and 2$\times$ time-division multiplexing (TDM) to achieve an 8$\times$ receive (RX) channel-count reduction. Equalization, trained using a pseudorandom bit-sequence generated on the chip, reduces TDM-induced crosstalk by 10 dB, enabling power-efficient scaling of the cable drivers. The ASICs also implement a novel transmit (TX) beamformer (BF) that operates as a programmable digital pipeline, which enables steering of arbitrary pulse-density modulated (PDM) waveforms. The TX BF drives element-level 65 V unipolar pulsers, which in turn drive the CMUT array. Both the TX BF and RX $\mu$BF are programmed with shift-registers (SRs) that can either be programmed in a row-column fashion for fast upload times, or daisy-chain fashion for a higher flexibility. The layout of the ASICs is matched to the 365-$\mu$m-pitch monolithically-integrated CMUT array. While operating, the RX and logic power consumption per element is 0.85 and 0.10 mW, respectively. TX power consumption is highly waveform dependent, but is nominally 0.34 mW. Compared to the prior art, the probe has the highest volume rate, and features among the largest imaging arrays (both in terms of element-count and aperture) with a high flexibility in defining the TX waveform. These properties make it a suitable option for applications requiring HVR imaging of a large region of interest.


  • Open Access

    A Tiled Ultrasound Matrix Transducer for Volumetric Imaging of the Carotid Artery

    by Djalma Simões dos Santos, Fabian Fool, Moein Mozaffarzadeh, Maysam Shabanimotlagh, Emile Noothout, Taehoon Kim, Nuriel Rozsa, Hendrik J. Vos, Johan G. Bosch, Michiel A. P. Pertijs, et al.

    High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for channel reduction. However, the fabrication of such a transducer integrated with one very large ASIC is very challenging and expensive. In this study, we develop a prototype matrix transducer mounted on top of multiple identical ASICs in a tiled configuration. The matrix was designed to have 7680 piezoelectric elements with a pitch of 300 μm × 150 μm integrated with an array of 8 × 1 tiled ASICs. The performance of the prototype is characterized by a series of measurements. The transducer exhibits a uniform behavior with the majority of the elements working within the −6 dB sensitivity range. In transmit, the individual elements show a center frequency of 7.5 MHz, a −6 dB bandwidth of 45%, and a transmit efficiency of 30 Pa/V at 200 mm. In receive, the dynamic range is 81 dB, and the minimum detectable pressure is 60 Pa per element. To demonstrate the imaging capabilities, we acquired 3D images using a commercial wire phantom.


  • Open Access

    Functional Optical Coherence Tomography for Intrinsic Signal Optoretinography: Recent Developments and Deployment Challenges

    by Tae-Hoon Kim, Guangying Ma, Taeyoon Son, Xincheng Yao

    Intrinsic optical signal (IOS) imaging of the retina, also termed as optoretinography (ORG), promises a noninvasive method for objective assessment of retinal function. By providing unparalleled capability to differentiate individual layers of the retina, functional optical coherence tomography (OCT) has been actively investigated for intrinsic signal ORG measurements. However, clinical deployment of functional OCT for quantitative ORG is still challenging due to the lack of a standardized imaging protocol and the complication of IOS sources and mechanisms. This article aims to summarize recent developments of functional OCT for ORG measurement, OCT intensity- and phase-based IOS processing. Technical challenges and perspectives of quantitative IOS analysis and ORG interpretations are discussed.

  • Open Access

    Design of an Ultrasound Transceiver ASIC with a Switching-Artifact Reduction Technique for 3D Carotid Artery Imaging

    by Taehoon Kim, Fabian Fool, Djalma Simoes dos Santos, Zu-Yao Chang, Emile Noothout, Hendrik J. Vos, Johan G. Bosch, Martin D. Verweij, Nico de Jong, Michiel A. P. Pertijs

    This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a programmable switch matrix that allowed selected transducer elements in each row to be connected to a transmit and receive channel of an imaging system. This made the probe operate like an electronically translatable linear array, allowing large-aperture matrix arrays to be interfaced with a manageable number of system channels. This paper presents a second-generation ASIC that employed an improved switch design to minimize clock feedthrough and charge-injection effects of high-voltage metal–oxide–semiconductor field-effect transistors (HV MOSFETs), which in the first-generation ASIC caused parasitic transmissions and associated imaging artifacts. The proposed switch controller, implemented with cascaded non-overlapping clock generators, generated control signals with improved timing to mitigate the effects of these non-idealities. Both simulation results and electrical measurements showed a 20 dB reduction of the switching artifacts. In addition, an acoustic pulse-echo measurement successfully demonstrated a 20 dB reduction of imaging artifacts.


  • An 80.2 dB DR 23.25 mW/Channel 8-Channel Ultrasound Receiver With a Beamforming Embedded SAR ADC

    by Taehoon Kim, Sangmin Shin, Suhwan Kim

    An 8-channel ultrasound receiver compatible with in-probe electronics for 3-D ultrasound imaging is proposed. It has eight analog front-ends for signal conditioning and a beamforming embedded SAR analog-to-digital converter (ADC) for performing both an 8-to-1 analog summation and its digitization in charge mode. By combining the 30-dB programmable gain of the analog front-ends with the 60-dB signal-to-noise ratio of the ADC, the 8-channel receiver achieves the DR of 80.2 dB. The delay is set in increments of 4.17 ns, up to a maximum of 292 ns. Implemented in a 0.18-μm CMOS process, a prototype occupies an active area of 0.525 mm 2 /channel and draws 23.25 mW/channel at a sampling frequency of 20 MHz.


  • A 12.1mW, 60dB SNR, 8-channel beamforming embedded SAR ADC for ultrasound imaging systems

    by Taehoon Kim, Suhwan Kim

    A power-efficient analog beamforming embedded SAR ADC for ultrasound imaging systems is presented. It is constructed from multiple sub-beamforming SAR ADCs, which sequentially perform analog beamforming and analog-to-digital conversion for an assigned focal point on a scan-line. Power is saved because these operations are carried out in the charge domain without a summing op-amp. This is realized by a capacitor beamforming digital-to-analog converter, which acts as both an analog memory cell and a digital-to-analog converter. The proposed analog beamformer was implemented in a 0.18pm CMOS process, and its power consumption is 12.1mW. The delay resolution is 4.17ns and the maximum achievable delay is 292ns. The sampling frequency is 20MS/s and the SNR of the prototype is 60dB. The circuit occupies an active area of 2.2mm2.


  • A CMOS analog front-end for driving a high-speed SAR ADC in low-power ultrasound imaging systems

    by Taehoon Kim, Han Yang, Sangmin Shin, Hyongmin Lee, Suhwan Kim

    In recent studies of ultrasound imaging systems, successive approximation register (SAR) analog-to-digital converters (ADCs) are suggested as an alternative architecture for low-power ultrasound receiver integrated circuits. However, the sampling period of a high-speed SAR ADC is very short - less than a few nanoseconds. This results in the need of a very wide unity-gain bandwidth of the amplifier in the anti-aliasing filter (AAF), and it also causes more serious kick-back noise. In this paper, a single-channel analog front-end (AFE) with a RC filter for a high-speed SAR ADC is presented. The RC filter relaxes the bandwidth requirement of the amplifier in the AAF by 16% and reduces kick-back noise coming from the ADC input. The proposed AFE is fabricated in 0.18μm CMOS process. The design achieves 5.05nV/√Hz input-referred noise density and the voltage gain is controlled in the range of [-3.02, 30.6] dB in a linear-in-dB scale with 16 steps by a 4-bit digital code. Our AFE circuit consumes 30mA from a 1.8V supply.


  • MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models

    by Taehoon Kim, Sangmin Shin, Hyongmin Lee, Hyunsook Lee, Heewon Kim, Eunhee Shin, Suhwan Kim

    A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.