A 2000-volumes/s 3-D Ultrasound Probe With Monolithically-Integrated 23 × 23-mm² 4096 -Element CMUT Array
- 11 February 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (4) , 1397-1410
Abstract
This article presents a 4096-element ultrasound probe for high volume-rate (HVR) cardiovascular imaging. The probe consists of two application-specific integrated circuits (ASICs), each of which interfaces with a 2048-element monolithically-integrated capacitive micro-machined ultrasound transducer (CMUT) array. The probe can image a 60$^{\circ}$ $\times$ 60$^{\circ}$ $\times$ 10-cm volume at 2000 volumes/s, the highest volume-rate with in-probe channel-count reduction reported to date. It uses 2 $\times$ 2 delay-and-sum micro-beamforming ($\mu$BF) and 2$\times$ time-division multiplexing (TDM) to achieve an 8$\times$ receive (RX) channel-count reduction. Equalization, trained using a pseudorandom bit-sequence generated on the chip, reduces TDM-induced crosstalk by 10 dB, enabling power-efficient scaling of the cable drivers. The ASICs also implement a novel transmit (TX) beamformer (BF) that operates as a programmable digital pipeline, which enables steering of arbitrary pulse-density modulated (PDM) waveforms. The TX BF drives element-level 65 V unipolar pulsers, which in turn drive the CMUT array. Both the TX BF and RX $\mu$BF are programmed with shift-registers (SRs) that can either be programmed in a row-column fashion for fast upload times, or daisy-chain fashion for a higher flexibility. The layout of the ASICs is matched to the 365-$\mu$m-pitch monolithically-integrated CMUT array. While operating, the RX and logic power consumption per element is 0.85 and 0.10 mW, respectively. TX power consumption is highly waveform dependent, but is nominally 0.34 mW. Compared to the prior art, the probe has the highest volume rate, and features among the largest imaging arrays (both in terms of element-count and aperture) with a high flexibility in defining the TX waveform. These properties make it a suitable option for applications requiring HVR imaging of a large region of interest.Keywords
Funding Information
- Ultra-X-Treme Project through Netherlands Organization for Scientific Research (P17-32)
This publication has 40 references indexed in Scilit:
- Increasing abdominal aortic aneurysm curvature visibility using 3D dual probe bistatic ultrasound imaging combined with probe translationUltrasonics, 2024
- 3D-Ultrasound Based Mechanical and Geometrical Analysis of Abdominal Aortic Aneurysms and Relationship to GrowthAnnals of Biomedical Engineering, 2023
- Dual mode CMUT Array Operation for Skull Imaging and Passive Acoustic Monitoring in Transcranial Ultrasound2021
- Ultrasound-on-chip platform for medical imaging, analysis, and collective intelligenceProceedings of the National Academy of Sciences of the United States of America, 2021
- 34.1 An 8960-Element Ultrasound-on-Chip for Point-of-Care Ultrasound2021
- Helical toroid phantom for 3D flow imaging investigationsPhysics in Medicine & Biology, 2021
- 4D Blood Flow and Wall Shear Stress measured using Volumetric Ultrasound Image Velocimetry2020
- 4-D Echo-Particle Image Velocimetry in a Left Ventricular PhantomUltrasound in Medicine & Biology, 2020
- Editor's Choice – European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2019
- 3D ultrafast ultrasound imagingin vivoPhysics in Medicine & Biology, 2014