Kirill B. Pershin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kirill B. Pershin has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Nadezhda F. Pashinova
“Eximer” eye center; Academy of postgraduate education of the Federal Medical-Biological Agency
21 shared publications - Aleksandr Yu. Tsygankov
Helmholtz National Medical Research Center of Eye Diseases; Russian University of Medicine
17 shared publications - A. A. Panov
“Eximer” eye center; Academy of postgraduate education of the Federal Medical-Biological Agency
3 shared publications - E. A. Antonov
Excimer Eye Centre
3 shared publications - E. A. Korneeva
Ophthalmological center Eximer
2 shared publications - E.A. Antonov2 shared publications
Latest Publications
- Open Access
- 28 December 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (4) , 853-865
Comparison of Biometric Parameters in Standard and Segmental Optical Biometry
Optical biometry is widely used in ophthalmology for different purposes. The Argos (Alcon, USA) device, which recently entered the Russian market, uses different refractive indices for different eye structures. This feature fundamentally distinguishes it from other models. The issue of its comparability with other biometers in the Russian population has not been researched sufficiently. Purpose. To compare keratometry in the flat (K1) and steep (K2) meridians, mean keratometry (Km), axial length (AL), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the frequency of relevant AL measurement between the Argos and IOLMaster 700 devices. Patients and methods . Two hundred fifty-one patients (368 eyes) were included in the study regardless of the presence of cataract: 244 females (66.3 %) and 124 males (33.7 %). The mean age was 68.18 ± 13.36 years (24–92 years). The exclusion criteria were: unstable visual fixation, pseudophakia, aphakia, history of vitrectomy, the difference between the dates of biometry on the Argos and IOLMaster 700 more than 1 month. Clinical significance of the differences was assessed using Bland-Altman plots and 95 % limits of agreement (95 % LoA). Results. The frequency of relevant AL measurements was 100 % on the Argos, and 99.2 % on the IOLMaster 700 (p = 0.25). The K1, K2, Km, ACD, LT and WTW measurements were significantly higher on the Argos compared to the IOLMaster 700. AL did not differ significantly only in the range of 22.0–23.0 mm. At AL < 22.0 mm this parameter was significantly higher on the Argos, at AL > 23.0 mm — on the IOLMaster 700. The more was the AL deviation from the range of 22.0–23.0 mm, the greater was the difference in AL between the two biometers. The difference in ACD was inversely proportional to the magnitude of ACD. Strong correlations were found for all studied parameters on the two biometers, however, 95 % LoA were wide. Conclusion. The differences in keratometry, AL, ACD, LT and WTW between the Argos and IOLMaster 700 are clinically significant and therefore this biometers cannot be considered interchangeable in all clinical situations.
- 28 December 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (4) , 853-865
Open AccessComparison of Biometric Parameters in Standard and Segmental Optical Biometry
Optical biometry is widely used in ophthalmology for different purposes. The Argos (Alcon, USA) device, which recently entered the Russian market, uses different refractive indices for different eye structures. This feature fundamentally distinguishes it from other models. The issue of its comparability with other biometers in the Russian population has not been researched sufficiently. Purpose. To compare keratometry in the flat (K1) and steep (K2) meridians, mean keratometry (Km), axial length (AL), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the frequency of relevant AL measurement between the Argos and IOLMaster 700 devices. Patients and methods . Two hundred fifty-one patients (368 eyes) were included in the study regardless of the presence of cataract: 244 females (66.3 %) and 124 males (33.7 %). The mean age was 68.18 ± 13.36 years (24–92 years). The exclusion criteria were: unstable visual fixation, pseudophakia, aphakia, history of vitrectomy, the difference between the dates of biometry on the Argos and IOLMaster 700 more than 1 month. Clinical significance of the differences was assessed using Bland-Altman plots and 95 % limits of agreement (95 % LoA). Results. The frequency of relevant AL measurements was 100 % on the Argos, and 99.2 % on the IOLMaster 700 (p = 0.25). The K1, K2, Km, ACD, LT and WTW measurements were significantly higher on the Argos compared to the IOLMaster 700. AL did not differ significantly only in the range of 22.0–23.0 mm. At AL < 22.0 mm this parameter was significantly higher on the Argos, at AL > 23.0 mm — on the IOLMaster 700. The more was the AL deviation from the range of 22.0–23.0 mm, the greater was the difference in AL between the two biometers. The difference in ACD was inversely proportional to the magnitude of ACD. Strong correlations were found for all studied parameters on the two biometers, however, 95 % LoA were wide. Conclusion. The differences in keratometry, AL, ACD, LT and WTW between the Argos and IOLMaster 700 are clinically significant and therefore this biometers cannot be considered interchangeable in all clinical situations.
- Open Access
- 1 October 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (3) , 582-588
First Experience of Using Segmental Optical Biometry for IOL Power Calculation in the Russian Federation
Purpose. To evaluate the results of segmented optical biometry for IOL power calculation in a short-term follow-up period. Patients and methods. 68 patients (90 eyes) after implantation of various IOL models were included in the study. The mean age was 70.43 ± 9.55 years (44–89 years). Women predominated in the sample (n = 49; 72 %). Optical biometry was performed with the Argos device (Alcon, USA) and IOLMaster 700 (Zeiss, Germany). IOL calculation was performed based on Argos data using the formulas: Barrett Universal II, Cooke K6, EVO, Hill-RBF, Hoffer QST, Kane, Pearl DGS. Phacoemulsification with IOL implantation was performed using the standard technique. The observation period was 1 month. Results. One month after the operation there was a significant increase in the distance UCVA (from 0.1 (0.04; 0.20) before the operation to 0.7 (0.188; 1.00)), distance BCVA (from 0.5 (0.3; 0.8) to 1.0 (0.9; 1.0)), and a decrease in IOP from 15 (13; 16.25) to 13 (11; 15) mmHg. The absolute error was significantly lower for the Cooke K6 formula compared with Kane (0.230 (0.130; 0.389) and 0.268 (0.143; 0.405) D, respectively, p = 0.0005) and for the Hill-RBF formula compared with Hoffer QST (0.190 (0.086; 0.399) and 0.248 (0.133; 0.478) D, respectively, p = 0.0007). The share of eyes with refraction within ±0.25 D of the predicted value was significantly higher for the Hill-RBF formula compared with Kane (62.22% and 45.56%, respectively, p = 0.002). The proportion of eyes with refraction within ±0.5, ±1.0, and ±1.5 D of the predicted value did not differ significantly between the formulas. Axial length (AL) measured with Argos, was significantly longer in “short” eyes (AL≤ 22.0 mm) and shorter in “average” and “long” eyes (AL≥ 26.0 mm) compared to IOLMaster 700. Conclusion. This work presents an analysis of the first experience of using segmented optical biometry for calculation of various types of IOLs in the Russian Federation. A favorable clinical and functional effect and a high frequency of achieving target refraction values were noted. The Hill-RBF formula demonstrates some advantage over the Kane and Hoffer QST formulas, and the Cooke K6 formula over Kane.
- 1 October 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (3) , 582-588
Open AccessFirst Experience of Using Segmental Optical Biometry for IOL Power Calculation in the Russian Federation
Purpose. To evaluate the results of segmented optical biometry for IOL power calculation in a short-term follow-up period. Patients and methods. 68 patients (90 eyes) after implantation of various IOL models were included in the study. The mean age was 70.43 ± 9.55 years (44–89 years). Women predominated in the sample (n = 49; 72 %). Optical biometry was performed with the Argos device (Alcon, USA) and IOLMaster 700 (Zeiss, Germany). IOL calculation was performed based on Argos data using the formulas: Barrett Universal II, Cooke K6, EVO, Hill-RBF, Hoffer QST, Kane, Pearl DGS. Phacoemulsification with IOL implantation was performed using the standard technique. The observation period was 1 month. Results. One month after the operation there was a significant increase in the distance UCVA (from 0.1 (0.04; 0.20) before the operation to 0.7 (0.188; 1.00)), distance BCVA (from 0.5 (0.3; 0.8) to 1.0 (0.9; 1.0)), and a decrease in IOP from 15 (13; 16.25) to 13 (11; 15) mmHg. The absolute error was significantly lower for the Cooke K6 formula compared with Kane (0.230 (0.130; 0.389) and 0.268 (0.143; 0.405) D, respectively, p = 0.0005) and for the Hill-RBF formula compared with Hoffer QST (0.190 (0.086; 0.399) and 0.248 (0.133; 0.478) D, respectively, p = 0.0007). The share of eyes with refraction within ±0.25 D of the predicted value was significantly higher for the Hill-RBF formula compared with Kane (62.22% and 45.56%, respectively, p = 0.002). The proportion of eyes with refraction within ±0.5, ±1.0, and ±1.5 D of the predicted value did not differ significantly between the formulas. Axial length (AL) measured with Argos, was significantly longer in “short” eyes (AL≤ 22.0 mm) and shorter in “average” and “long” eyes (AL≥ 26.0 mm) compared to IOLMaster 700. Conclusion. This work presents an analysis of the first experience of using segmented optical biometry for calculation of various types of IOLs in the Russian Federation. A favorable clinical and functional effect and a high frequency of achieving target refraction values were noted. The Hill-RBF formula demonstrates some advantage over the Kane and Hoffer QST formulas, and the Cooke K6 formula over Kane.
- Open Access
- 24 June 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (2) , 31-37
Comparative analysis of the clinical results of implantation of monofocal IOLs and EDOF IOLs in patients with a history of refractive surgery
Aim – to carry out a retrospective comparative analysis of the clinical results of implantation of monofocal and EDOF IOLs in patients with a history of refractive surgery. Material and methods. The final study protocol included data from 101 patients (133 eyes). After phacoemulsification, various IOL models were implanted. Patients were divided into 2 groups: Group 1, patients with implanted monofocal IOLs, Group 2, with implanted EDOF IOLs. The work included a comparative analysis of uncorrected and corrected distance visual acuity (UCVA and CDVA), refraction data before phacoemulsification and 1 month after cataract surgery. In patients of Group 2, UCVA and CDVA at near (30 cm) and medium (45 cm) distances were also assessed in the postoperative period. Results. 1 month after surgery: in Group 1, the uncorrected visual acuity at a distance after surgery increased to 0.60 (0.40; 0.90), and the visual acuity was 0.80 (0.60; 1.00), in Group 2, the uncorrected visual acuity after surgery was 0.60 (0.50; 0.90), and the visual acuity was 0.80 (0.70; 1.00). At the near distance (30 cm), the uncorrected visual acuity and visual acuity in patients in Group 2 were 0.54 ± 0.18 and 0.50 ± 0.17, respectively. At the medium distance (45 cm), these values were 0.42 ± 0.17 and 0.50 ± 0.17 (45 cm), respectively. Conclusions. EDOF IOL implantation provides high refractive results at the distance, comparable to the results of monofocal IOL implantation in patients with a history of keratorefractive surgeries. EDOF IOLs provide acceptable visual acuity at near and intermediate distances. At the same time, near uncorrected visual acuity at 30 cm has higher values than at 45 cm, due to the summation of the pseudoaccommodative effect of the EDOF IOL and the optically altered cornea.
- 24 June 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (2) , 31-37
Open AccessComparative analysis of the clinical results of implantation of monofocal IOLs and EDOF IOLs in patients with a history of refractive surgery
Aim – to carry out a retrospective comparative analysis of the clinical results of implantation of monofocal and EDOF IOLs in patients with a history of refractive surgery. Material and methods. The final study protocol included data from 101 patients (133 eyes). After phacoemulsification, various IOL models were implanted. Patients were divided into 2 groups: Group 1, patients with implanted monofocal IOLs, Group 2, with implanted EDOF IOLs. The work included a comparative analysis of uncorrected and corrected distance visual acuity (UCVA and CDVA), refraction data before phacoemulsification and 1 month after cataract surgery. In patients of Group 2, UCVA and CDVA at near (30 cm) and medium (45 cm) distances were also assessed in the postoperative period. Results. 1 month after surgery: in Group 1, the uncorrected visual acuity at a distance after surgery increased to 0.60 (0.40; 0.90), and the visual acuity was 0.80 (0.60; 1.00), in Group 2, the uncorrected visual acuity after surgery was 0.60 (0.50; 0.90), and the visual acuity was 0.80 (0.70; 1.00). At the near distance (30 cm), the uncorrected visual acuity and visual acuity in patients in Group 2 were 0.54 ± 0.18 and 0.50 ± 0.17, respectively. At the medium distance (45 cm), these values were 0.42 ± 0.17 and 0.50 ± 0.17 (45 cm), respectively. Conclusions. EDOF IOL implantation provides high refractive results at the distance, comparable to the results of monofocal IOL implantation in patients with a history of keratorefractive surgeries. EDOF IOLs provide acceptable visual acuity at near and intermediate distances. At the same time, near uncorrected visual acuity at 30 cm has higher values than at 45 cm, due to the summation of the pseudoaccommodative effect of the EDOF IOL and the optically altered cornea.
- Open Access
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 61-72
Microshunt PRESERFLO™ for microinvasive glaucoma surgery
The current gold standard of glaucoma surgery is trabeculectomy, which allows sustained reduction of intraocular pressure (IOP). However, trabeculectomy is relatively traumatic and is associated with a risk of specific complications. As a result, a number of devices for microinvasive glaucoma surgery have been developed, designed to create a hypotensive effect comparable to trabeculectomy, coupled with minimal surgical trauma.Microshunt PRESERFLO™ (Santen) is a polymer microshunt that facilitats the outflow of aqueous humor into the subconjunctival space with the formation of a filtering bleb. It is implanted through a subconjunctival approach, typical for trabeculectomy, however, due to the controlled aqueous outflow it minimizes the risk of complications typical for glaucoma interventions.Long-term (up to 5 years) efficacy and safety of PRESERFLO™ microshunt implantation have been demonstrated in a number of studies, including those comparing PRESERFLO™ with other surgeries. Meta-analyses comparing PRESERFLO™ and trabeculectomy show comparable efficacy of the interventions with a lower risk of complications in PRESERFLO™. Studies comparing PRESERFLO™ with similarly designed microshunt XEN (Allergan, Plc, Ireland) show that PRESERFLO™ is either equally or more effective.
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 61-72
Open AccessMicroshunt PRESERFLO™ for microinvasive glaucoma surgery
The current gold standard of glaucoma surgery is trabeculectomy, which allows sustained reduction of intraocular pressure (IOP). However, trabeculectomy is relatively traumatic and is associated with a risk of specific complications. As a result, a number of devices for microinvasive glaucoma surgery have been developed, designed to create a hypotensive effect comparable to trabeculectomy, coupled with minimal surgical trauma.Microshunt PRESERFLO™ (Santen) is a polymer microshunt that facilitats the outflow of aqueous humor into the subconjunctival space with the formation of a filtering bleb. It is implanted through a subconjunctival approach, typical for trabeculectomy, however, due to the controlled aqueous outflow it minimizes the risk of complications typical for glaucoma interventions.Long-term (up to 5 years) efficacy and safety of PRESERFLO™ microshunt implantation have been demonstrated in a number of studies, including those comparing PRESERFLO™ with other surgeries. Meta-analyses comparing PRESERFLO™ and trabeculectomy show comparable efficacy of the interventions with a lower risk of complications in PRESERFLO™. Studies comparing PRESERFLO™ with similarly designed microshunt XEN (Allergan, Plc, Ireland) show that PRESERFLO™ is either equally or more effective.
- Open Access
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 29-39
Anterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma
PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma.METHODS. The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed.RESULTS. In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP).The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP.The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length.CONCLUSION. The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 29-39
Open AccessAnterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma
PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma.METHODS. The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed.RESULTS. In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP).The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP.The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length.CONCLUSION. The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.
- Open Access
- 13 April 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (1) , 45-52
Comparative analysis of the results of IOL implantation of full and extended partial range of vision in patients with a history of keratorefractive surgeries
Aim – to conduct a comparative retrospective analysis of the clinical outcomes of implantation of multifocal intraocular lenses (MIOLs) and intraocular lenses with extended depth of focus (EDOF) in patients with a history of refractive surgery. To evaluate the impact of the ocular surface condition on the quality of vision and patient satisfaction in the long term after phacoemulsification (PEC). Material and methods. In a multicenter retrospective cohort study, data from 72 patients (101 eyes) aged 25 to 76 years were analyzed. After phacoemulsification, various models of intraocular lenses (IOLs) were implanted. The patients were divided into 2 groups: Group 1, patients with implanted full-range of vision IOLs - MIOLs (18 people, 26 eyes); Group 2, patients with implanted extended partial range of vision IOLs - EDOF (54 people, 75 eyes). All patients underwent a standard comprehensive ophthalmological examination. The work included a comparative analysis of uncorrected and corrected distance visual acuity (UCVA and CDVA), refraction data before phacoemulsification and 1 month after cataract surgery. In the late postoperative period, UCVA and CDVA were assessed at near (30 cm) and intermediate (45 cm) distances in both observation groups. The functional consequences of premium IOL implantation and subjective patient satisfaction were assessed using the individual Visual Function-14 (VF-14) quality of life questionnaire. Remote risk factors for the development and progression of dry eye syndrome (DES) were also recorded using the Schirmer 1 Test and the Norn test. Additionally, all subjects completed the Ocular Surface Disease Index (OSDI) questionnaire. Results. The conducted analysis showed statistically significant change in visual acuity (VA) 1 month after surgery (p 0.001) in both observation groups. In Group 1, UCVA at distance after surgery was 0.70 (0.55–1.00), and CCVA was 0.80 (0.70–1.00). In Group 2, UCVA after surgery increased to 0.60 (0.45–0.85), CCVA 0.80 (0.70–1.00). At near distance (30 cm), UCVA and CCVA in patients with implanted full-range IOLs were 0.73±0.17 and 0.73±0.17, at intermediate distance, 0.40±0.17 and 0.47±0.17, respectively. In the second observation group, with implantation of the extended partial range of vision IOL, the UCVA and UCVA at near distance (30 cm) were 0.54±0.21 and 0.50±0.20, at medium distance (45 cm), 0.42±0.17 and 0.50±0.17, respectively. In both observation groups, a significant decrease in tear production and tear film stability (TS) was noted. The average values of the international OSDI questionnaire in all groups ranged from 21.53 to 22.38 points, which corresponds to normal values. According to the results of the VF-14 questionnaire, high subjective patient satisfaction was revealed, amounting to from 88.50 to 95.50 points. Conclusions. The results of implantation of full-range IOLs and extended partial range IOLs showed comparable high clinical results of distance VA one month after FEC. However, at near distance, multifocal IOLs provided higher visual acuity, and at intermediate distance, on the contrary, extended partial range of vision. These types of premium high-tech pseudo-accommodating IOLs can provide high subjective satisfaction of patients with a history of keratorefractive surgeries, taking into account their individual needs in everyday life. This work confirms the need for an individual approach to each patient after previous keratorefractive surgery.
- 13 April 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (1) , 45-52
Open AccessComparative analysis of the results of IOL implantation of full and extended partial range of vision in patients with a history of keratorefractive surgeries
Aim – to conduct a comparative retrospective analysis of the clinical outcomes of implantation of multifocal intraocular lenses (MIOLs) and intraocular lenses with extended depth of focus (EDOF) in patients with a history of refractive surgery. To evaluate the impact of the ocular surface condition on the quality of vision and patient satisfaction in the long term after phacoemulsification (PEC). Material and methods. In a multicenter retrospective cohort study, data from 72 patients (101 eyes) aged 25 to 76 years were analyzed. After phacoemulsification, various models of intraocular lenses (IOLs) were implanted. The patients were divided into 2 groups: Group 1, patients with implanted full-range of vision IOLs - MIOLs (18 people, 26 eyes); Group 2, patients with implanted extended partial range of vision IOLs - EDOF (54 people, 75 eyes). All patients underwent a standard comprehensive ophthalmological examination. The work included a comparative analysis of uncorrected and corrected distance visual acuity (UCVA and CDVA), refraction data before phacoemulsification and 1 month after cataract surgery. In the late postoperative period, UCVA and CDVA were assessed at near (30 cm) and intermediate (45 cm) distances in both observation groups. The functional consequences of premium IOL implantation and subjective patient satisfaction were assessed using the individual Visual Function-14 (VF-14) quality of life questionnaire. Remote risk factors for the development and progression of dry eye syndrome (DES) were also recorded using the Schirmer 1 Test and the Norn test. Additionally, all subjects completed the Ocular Surface Disease Index (OSDI) questionnaire. Results. The conducted analysis showed statistically significant change in visual acuity (VA) 1 month after surgery (p 0.001) in both observation groups. In Group 1, UCVA at distance after surgery was 0.70 (0.55–1.00), and CCVA was 0.80 (0.70–1.00). In Group 2, UCVA after surgery increased to 0.60 (0.45–0.85), CCVA 0.80 (0.70–1.00). At near distance (30 cm), UCVA and CCVA in patients with implanted full-range IOLs were 0.73±0.17 and 0.73±0.17, at intermediate distance, 0.40±0.17 and 0.47±0.17, respectively. In the second observation group, with implantation of the extended partial range of vision IOL, the UCVA and UCVA at near distance (30 cm) were 0.54±0.21 and 0.50±0.20, at medium distance (45 cm), 0.42±0.17 and 0.50±0.17, respectively. In both observation groups, a significant decrease in tear production and tear film stability (TS) was noted. The average values of the international OSDI questionnaire in all groups ranged from 21.53 to 22.38 points, which corresponds to normal values. According to the results of the VF-14 questionnaire, high subjective patient satisfaction was revealed, amounting to from 88.50 to 95.50 points. Conclusions. The results of implantation of full-range IOLs and extended partial range IOLs showed comparable high clinical results of distance VA one month after FEC. However, at near distance, multifocal IOLs provided higher visual acuity, and at intermediate distance, on the contrary, extended partial range of vision. These types of premium high-tech pseudo-accommodating IOLs can provide high subjective satisfaction of patients with a history of keratorefractive surgeries, taking into account their individual needs in everyday life. This work confirms the need for an individual approach to each patient after previous keratorefractive surgery.
- Open Access
- 26 March 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (1) , 24-31
Preliminary outcomes of PreserFlo® microshunt implantation in patients with primary open-angle glaucoma
PURPOSE. To evaluate preliminary outcomes of PreserFlo® drainage system implantation for glaucoma treatment in terms of safety and efficacy.METHODS. In this open prospective study, 9 patients (9 eyes), including 7 men and 2 women, diagnosed with primary open-angle glaucoma were examined and underwent surgery. All patients underwent implantation of the PreserFlo® drainage system. The average age of the patients was 74.1±11.3 (59–89) years. Standard ophthalmological examinations were performed preoperatively and at 1 day, 7 days, 1 month, and up to 5 months postoperatively. The maximum follow-up period was 5 months.RESULTS. No intraoperative complications were observed in the early or late postoperative periods. One patient underwent needling of the filtration bleb postoperatively.A pronounced hypotensive effect was noted in all patients one week after surgery, which persisted in seven out of nine patients for up to two months. Two patients experienced a gradual increase in intraocular pressure (IOP) to 20–23 mm Hg, necessitating additional topical hypotensive therapy. All patients exhibited an improvement in both corrected and uncorrected visual acuity at the longest follow-up. Given the severity of the patients' conditions (multiple previous surgeries and maximal medical therapy), surgical outcomes were categorized as "complete success" and "relative success."CONCLUSION. This study presents the first short-term (up to 5 months) analysis of the outcomes of PreserFlo® drainage device implantation in patients with primary open-angle glaucoma in the Russian Federation. Preliminary findings indicate that the device is both effective and safe. Further studies with a larger patient cohort are required to assess long-term outcomes.
- 26 March 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (1) , 24-31
Open AccessPreliminary outcomes of PreserFlo® microshunt implantation in patients with primary open-angle glaucoma
PURPOSE. To evaluate preliminary outcomes of PreserFlo® drainage system implantation for glaucoma treatment in terms of safety and efficacy.METHODS. In this open prospective study, 9 patients (9 eyes), including 7 men and 2 women, diagnosed with primary open-angle glaucoma were examined and underwent surgery. All patients underwent implantation of the PreserFlo® drainage system. The average age of the patients was 74.1±11.3 (59–89) years. Standard ophthalmological examinations were performed preoperatively and at 1 day, 7 days, 1 month, and up to 5 months postoperatively. The maximum follow-up period was 5 months.RESULTS. No intraoperative complications were observed in the early or late postoperative periods. One patient underwent needling of the filtration bleb postoperatively.A pronounced hypotensive effect was noted in all patients one week after surgery, which persisted in seven out of nine patients for up to two months. Two patients experienced a gradual increase in intraocular pressure (IOP) to 20–23 mm Hg, necessitating additional topical hypotensive therapy. All patients exhibited an improvement in both corrected and uncorrected visual acuity at the longest follow-up. Given the severity of the patients' conditions (multiple previous surgeries and maximal medical therapy), surgical outcomes were categorized as "complete success" and "relative success."CONCLUSION. This study presents the first short-term (up to 5 months) analysis of the outcomes of PreserFlo® drainage device implantation in patients with primary open-angle glaucoma in the Russian Federation. Preliminary findings indicate that the device is both effective and safe. Further studies with a larger patient cohort are required to assess long-term outcomes.
- 25 June 2024
- Published by Mediprint in Reflection
- No. 1
Implantation of a hydrophobic acrylic monofocal intraocular lens in a preloaded injector
Aim. To evaluate clinical and functional results of implantation of a new hydrophobic acrylic monofocal IOL in a preloaded injector. Methods. The prospective study included 60 patients (66 eyes) after Hoya iSert® 250/251 IOL implantation (31 patients, 35 eyes, group 1) and a new Hoya Vivinex Multisert® XY1-SP IOL (29 patients, 31 eyes, group 2). IOL viscoimplantation was performed in 100 % of cases in group 1; in group 2 viscoimplantation was done in 45.1 % of cases and hydroimplantation in 54.9 %. Intraoperatively, corneal incision size was measured with a ruler before and after IOL implantation. Results In both groups, there was a statistically significant (p<0.05) increase of UCDVA from 0.28±0.09 in the preoperative period to 0.7±0.17 3 months after surgery in group 1 and from 0.24±0.10 in the preoperative period to 0.84±0.18 3 months after surgery in group 2. Slightly lower values of UCDVA in group 1 may be associated with a higher level of surgically induced astigmatism (SIA) in this group. Similar dynamics was shown for BCDVA (from 0.52±0.21 before surgery to 0.95±0.19 after 3 months of follow-up in group 1 and from 0.55±0.20 before surgery to 0.98±0.21 after 3 months of follow-up in group 2). No difference was found between the studied groups. After IOL implantation, there was an increase in incision size to 2.4±0.12 mm in group 1 and 2.1±0.08 mm in group 2 (p=0.04). Mean SIA after 3 months of observation was 1.1±0.16 D in group 1 and 0.48±0.07 D in group 2 (p=0.0007). Conclusion. This study presents a comparative analysis of implantation results with monofocal hydrophobic acrylic Hoya Vivinex IOL in a Multisert® preloaded injector and monofocal Hoya 250/251 IOLs in an Isert® injector. The advantage of the new IOL implantation in reducing the incidence of surgically induced astigmatism was shown. Key words: cataract; monofocal IOLs; Vivinex; Hoya 250; Hoya 251; surgically induced astigmatism.
- 25 June 2024
- Published by Mediprint in Reflection
- No. 1
Implantation of a hydrophobic acrylic monofocal intraocular lens in a preloaded injector
Aim. To evaluate clinical and functional results of implantation of a new hydrophobic acrylic monofocal IOL in a preloaded injector. Methods. The prospective study included 60 patients (66 eyes) after Hoya iSert® 250/251 IOL implantation (31 patients, 35 eyes, group 1) and a new Hoya Vivinex Multisert® XY1-SP IOL (29 patients, 31 eyes, group 2). IOL viscoimplantation was performed in 100 % of cases in group 1; in group 2 viscoimplantation was done in 45.1 % of cases and hydroimplantation in 54.9 %. Intraoperatively, corneal incision size was measured with a ruler before and after IOL implantation. Results In both groups, there was a statistically significant (p<0.05) increase of UCDVA from 0.28±0.09 in the preoperative period to 0.7±0.17 3 months after surgery in group 1 and from 0.24±0.10 in the preoperative period to 0.84±0.18 3 months after surgery in group 2. Slightly lower values of UCDVA in group 1 may be associated with a higher level of surgically induced astigmatism (SIA) in this group. Similar dynamics was shown for BCDVA (from 0.52±0.21 before surgery to 0.95±0.19 after 3 months of follow-up in group 1 and from 0.55±0.20 before surgery to 0.98±0.21 after 3 months of follow-up in group 2). No difference was found between the studied groups. After IOL implantation, there was an increase in incision size to 2.4±0.12 mm in group 1 and 2.1±0.08 mm in group 2 (p=0.04). Mean SIA after 3 months of observation was 1.1±0.16 D in group 1 and 0.48±0.07 D in group 2 (p=0.0007). Conclusion. This study presents a comparative analysis of implantation results with monofocal hydrophobic acrylic Hoya Vivinex IOL in a Multisert® preloaded injector and monofocal Hoya 250/251 IOLs in an Isert® injector. The advantage of the new IOL implantation in reducing the incidence of surgically induced astigmatism was shown. Key words: cataract; monofocal IOLs; Vivinex; Hoya 250; Hoya 251; surgically induced astigmatism.
- 6 May 2024
- Published by Mediprint in POINT OF VIEW. EAST – WEST
- No. 1
Non-diffractive intraocular lens with extended depth of focus optical power calculation
Purpose. Retrospective analysis of the accuracy of 7 formulas for calculating the optical power of a non-diffractive intraocular lens (IOL) with extended depth of focus. Material and methods. The retrospective study included 48 patients (81 eyes) with AcrySof IQ Vivity EDOF IOL implantation. The IOL optical power range was +15.0 to +30.0 D, and the target refraction was –0.25 to 0.25 D. The mean age of the patients was 59.1±7.7 (40–84) years.The SRK/T, Barrett Universal II, Haigis, Hoffer Q, Holladay 2, Olsen, and Kane formulas were retrospectively analyzed for effectiveness using appropriate constants. Each formula was optimized for the study group of patients to achieve an average refractive error as close to zero as possible. For each formula, the mean error (ME), mean absolute error (MAE), standard deviation (SD), median absolute error (MedAE), maximum absolute error (MaxAE), and percentage of eyes within the error range of 0.25, 0.5, 1.0, and 2.0 D were calculated. Results. The optimized constants were LF = 2.18, a0 = 1.39, a1 = 0.41, a2 = 0.13, personalized ACD = 5.74, ACD (Hoffer Q/Holladay 2) = 5.64/5.50, A-constant (SRK/T/Kane) = 119.2/119.3. The lowest MAE is determined for Kane, Barrett Universal II, and SRK/T formulas (p<0.05). The use of Haigis and Olsen formulas was characterized by a lower MAE compared to Holladay 2 and Hoffer Q formulas (p<0.05). With the exception of the Haigis and Hoffer Q formulas, all other formulas are shown to fall within the target refraction of ±2.00 D. With the Kane, Barrett Universal II and SRK/T formulas, 100% target refraction of ±1.00 D, 98‒99% target refraction of ±0.50 D, and greater than 80% target refraction of ±0.20 D were determined. Conclusion. In this study, we retrospectively evaluated the performance of seven formulas for calculating the optical power of the Acrysof IQ Vivity EDOF non-diffractive intraocular lens. The best results were shown for the Kane, Barrett Universal II and SRK/T formulas. Key words:cataract, phacoemulsification, EDOF, Symfony, IOL optical power calculation, constant optimization
- 6 May 2024
- Published by Mediprint in POINT OF VIEW. EAST – WEST
- No. 1
Non-diffractive intraocular lens with extended depth of focus optical power calculation
Purpose. Retrospective analysis of the accuracy of 7 formulas for calculating the optical power of a non-diffractive intraocular lens (IOL) with extended depth of focus. Material and methods. The retrospective study included 48 patients (81 eyes) with AcrySof IQ Vivity EDOF IOL implantation. The IOL optical power range was +15.0 to +30.0 D, and the target refraction was –0.25 to 0.25 D. The mean age of the patients was 59.1±7.7 (40–84) years.The SRK/T, Barrett Universal II, Haigis, Hoffer Q, Holladay 2, Olsen, and Kane formulas were retrospectively analyzed for effectiveness using appropriate constants. Each formula was optimized for the study group of patients to achieve an average refractive error as close to zero as possible. For each formula, the mean error (ME), mean absolute error (MAE), standard deviation (SD), median absolute error (MedAE), maximum absolute error (MaxAE), and percentage of eyes within the error range of 0.25, 0.5, 1.0, and 2.0 D were calculated. Results. The optimized constants were LF = 2.18, a0 = 1.39, a1 = 0.41, a2 = 0.13, personalized ACD = 5.74, ACD (Hoffer Q/Holladay 2) = 5.64/5.50, A-constant (SRK/T/Kane) = 119.2/119.3. The lowest MAE is determined for Kane, Barrett Universal II, and SRK/T formulas (p<0.05). The use of Haigis and Olsen formulas was characterized by a lower MAE compared to Holladay 2 and Hoffer Q formulas (p<0.05). With the exception of the Haigis and Hoffer Q formulas, all other formulas are shown to fall within the target refraction of ±2.00 D. With the Kane, Barrett Universal II and SRK/T formulas, 100% target refraction of ±1.00 D, 98‒99% target refraction of ±0.50 D, and greater than 80% target refraction of ±0.20 D were determined. Conclusion. In this study, we retrospectively evaluated the performance of seven formulas for calculating the optical power of the Acrysof IQ Vivity EDOF non-diffractive intraocular lens. The best results were shown for the Kane, Barrett Universal II and SRK/T formulas. Key words:cataract, phacoemulsification, EDOF, Symfony, IOL optical power calculation, constant optimization
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (2) , 40-46
Outcomes of extended depth of focus intraocular lenses implantation
Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS All groups showed a significant (p0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (2) , 40-46
Outcomes of extended depth of focus intraocular lenses implantation
Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS All groups showed a significant (p0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.