A. A. Panov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. A. Panov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr Yu. Tsygankov
Helmholtz National Medical Research Center of Eye Diseases; Russian University of Medicine
3 shared publications - Kirill B. Pershin
“Eximer” eye center; Academy of postgraduate education of the Federal Medical-Biological Agency
3 shared publications - Nadezhda F. Pashinova
“Eximer” eye center; Academy of postgraduate education of the Federal Medical-Biological Agency
3 shared publications - Alyona A. Petukhova
S. Fyodorov Eye Microsurgery Federal State Institution
1 shared publication - Boris Dmitrievich Tsygankov
FSBEI HE Russian University of Medicine of the Ministry of Health of the Russian Federation
1 shared publication - Marina Kazanfarova
SKOLKOVO School of Management, Odintsovo, Russian Federation
1 shared publication
Latest Publications
- Open Access
- 28 December 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (4) , 853-865
Comparison of Biometric Parameters in Standard and Segmental Optical Biometry
Optical biometry is widely used in ophthalmology for different purposes. The Argos (Alcon, USA) device, which recently entered the Russian market, uses different refractive indices for different eye structures. This feature fundamentally distinguishes it from other models. The issue of its comparability with other biometers in the Russian population has not been researched sufficiently. Purpose. To compare keratometry in the flat (K1) and steep (K2) meridians, mean keratometry (Km), axial length (AL), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the frequency of relevant AL measurement between the Argos and IOLMaster 700 devices. Patients and methods . Two hundred fifty-one patients (368 eyes) were included in the study regardless of the presence of cataract: 244 females (66.3 %) and 124 males (33.7 %). The mean age was 68.18 ± 13.36 years (24–92 years). The exclusion criteria were: unstable visual fixation, pseudophakia, aphakia, history of vitrectomy, the difference between the dates of biometry on the Argos and IOLMaster 700 more than 1 month. Clinical significance of the differences was assessed using Bland-Altman plots and 95 % limits of agreement (95 % LoA). Results. The frequency of relevant AL measurements was 100 % on the Argos, and 99.2 % on the IOLMaster 700 (p = 0.25). The K1, K2, Km, ACD, LT and WTW measurements were significantly higher on the Argos compared to the IOLMaster 700. AL did not differ significantly only in the range of 22.0–23.0 mm. At AL < 22.0 mm this parameter was significantly higher on the Argos, at AL > 23.0 mm — on the IOLMaster 700. The more was the AL deviation from the range of 22.0–23.0 mm, the greater was the difference in AL between the two biometers. The difference in ACD was inversely proportional to the magnitude of ACD. Strong correlations were found for all studied parameters on the two biometers, however, 95 % LoA were wide. Conclusion. The differences in keratometry, AL, ACD, LT and WTW between the Argos and IOLMaster 700 are clinically significant and therefore this biometers cannot be considered interchangeable in all clinical situations.
- 28 December 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (4) , 853-865
Open AccessComparison of Biometric Parameters in Standard and Segmental Optical Biometry
Optical biometry is widely used in ophthalmology for different purposes. The Argos (Alcon, USA) device, which recently entered the Russian market, uses different refractive indices for different eye structures. This feature fundamentally distinguishes it from other models. The issue of its comparability with other biometers in the Russian population has not been researched sufficiently. Purpose. To compare keratometry in the flat (K1) and steep (K2) meridians, mean keratometry (Km), axial length (AL), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the frequency of relevant AL measurement between the Argos and IOLMaster 700 devices. Patients and methods . Two hundred fifty-one patients (368 eyes) were included in the study regardless of the presence of cataract: 244 females (66.3 %) and 124 males (33.7 %). The mean age was 68.18 ± 13.36 years (24–92 years). The exclusion criteria were: unstable visual fixation, pseudophakia, aphakia, history of vitrectomy, the difference between the dates of biometry on the Argos and IOLMaster 700 more than 1 month. Clinical significance of the differences was assessed using Bland-Altman plots and 95 % limits of agreement (95 % LoA). Results. The frequency of relevant AL measurements was 100 % on the Argos, and 99.2 % on the IOLMaster 700 (p = 0.25). The K1, K2, Km, ACD, LT and WTW measurements were significantly higher on the Argos compared to the IOLMaster 700. AL did not differ significantly only in the range of 22.0–23.0 mm. At AL < 22.0 mm this parameter was significantly higher on the Argos, at AL > 23.0 mm — on the IOLMaster 700. The more was the AL deviation from the range of 22.0–23.0 mm, the greater was the difference in AL between the two biometers. The difference in ACD was inversely proportional to the magnitude of ACD. Strong correlations were found for all studied parameters on the two biometers, however, 95 % LoA were wide. Conclusion. The differences in keratometry, AL, ACD, LT and WTW between the Argos and IOLMaster 700 are clinically significant and therefore this biometers cannot be considered interchangeable in all clinical situations.
- Open Access
- 1 October 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (3) , 582-588
First Experience of Using Segmental Optical Biometry for IOL Power Calculation in the Russian Federation
Purpose. To evaluate the results of segmented optical biometry for IOL power calculation in a short-term follow-up period. Patients and methods. 68 patients (90 eyes) after implantation of various IOL models were included in the study. The mean age was 70.43 ± 9.55 years (44–89 years). Women predominated in the sample (n = 49; 72 %). Optical biometry was performed with the Argos device (Alcon, USA) and IOLMaster 700 (Zeiss, Germany). IOL calculation was performed based on Argos data using the formulas: Barrett Universal II, Cooke K6, EVO, Hill-RBF, Hoffer QST, Kane, Pearl DGS. Phacoemulsification with IOL implantation was performed using the standard technique. The observation period was 1 month. Results. One month after the operation there was a significant increase in the distance UCVA (from 0.1 (0.04; 0.20) before the operation to 0.7 (0.188; 1.00)), distance BCVA (from 0.5 (0.3; 0.8) to 1.0 (0.9; 1.0)), and a decrease in IOP from 15 (13; 16.25) to 13 (11; 15) mmHg. The absolute error was significantly lower for the Cooke K6 formula compared with Kane (0.230 (0.130; 0.389) and 0.268 (0.143; 0.405) D, respectively, p = 0.0005) and for the Hill-RBF formula compared with Hoffer QST (0.190 (0.086; 0.399) and 0.248 (0.133; 0.478) D, respectively, p = 0.0007). The share of eyes with refraction within ±0.25 D of the predicted value was significantly higher for the Hill-RBF formula compared with Kane (62.22% and 45.56%, respectively, p = 0.002). The proportion of eyes with refraction within ±0.5, ±1.0, and ±1.5 D of the predicted value did not differ significantly between the formulas. Axial length (AL) measured with Argos, was significantly longer in “short” eyes (AL≤ 22.0 mm) and shorter in “average” and “long” eyes (AL≥ 26.0 mm) compared to IOLMaster 700. Conclusion. This work presents an analysis of the first experience of using segmented optical biometry for calculation of various types of IOLs in the Russian Federation. A favorable clinical and functional effect and a high frequency of achieving target refraction values were noted. The Hill-RBF formula demonstrates some advantage over the Kane and Hoffer QST formulas, and the Cooke K6 formula over Kane.
- 1 October 2025
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 22 (3) , 582-588
Open AccessFirst Experience of Using Segmental Optical Biometry for IOL Power Calculation in the Russian Federation
Purpose. To evaluate the results of segmented optical biometry for IOL power calculation in a short-term follow-up period. Patients and methods. 68 patients (90 eyes) after implantation of various IOL models were included in the study. The mean age was 70.43 ± 9.55 years (44–89 years). Women predominated in the sample (n = 49; 72 %). Optical biometry was performed with the Argos device (Alcon, USA) and IOLMaster 700 (Zeiss, Germany). IOL calculation was performed based on Argos data using the formulas: Barrett Universal II, Cooke K6, EVO, Hill-RBF, Hoffer QST, Kane, Pearl DGS. Phacoemulsification with IOL implantation was performed using the standard technique. The observation period was 1 month. Results. One month after the operation there was a significant increase in the distance UCVA (from 0.1 (0.04; 0.20) before the operation to 0.7 (0.188; 1.00)), distance BCVA (from 0.5 (0.3; 0.8) to 1.0 (0.9; 1.0)), and a decrease in IOP from 15 (13; 16.25) to 13 (11; 15) mmHg. The absolute error was significantly lower for the Cooke K6 formula compared with Kane (0.230 (0.130; 0.389) and 0.268 (0.143; 0.405) D, respectively, p = 0.0005) and for the Hill-RBF formula compared with Hoffer QST (0.190 (0.086; 0.399) and 0.248 (0.133; 0.478) D, respectively, p = 0.0007). The share of eyes with refraction within ±0.25 D of the predicted value was significantly higher for the Hill-RBF formula compared with Kane (62.22% and 45.56%, respectively, p = 0.002). The proportion of eyes with refraction within ±0.5, ±1.0, and ±1.5 D of the predicted value did not differ significantly between the formulas. Axial length (AL) measured with Argos, was significantly longer in “short” eyes (AL≤ 22.0 mm) and shorter in “average” and “long” eyes (AL≥ 26.0 mm) compared to IOLMaster 700. Conclusion. This work presents an analysis of the first experience of using segmented optical biometry for calculation of various types of IOLs in the Russian Federation. A favorable clinical and functional effect and a high frequency of achieving target refraction values were noted. The Hill-RBF formula demonstrates some advantage over the Kane and Hoffer QST formulas, and the Cooke K6 formula over Kane.
- Open Access
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 29-39
Anterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma
PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma.METHODS. The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed.RESULTS. In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP).The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP.The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length.CONCLUSION. The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.
- 27 May 2025
- Published by Research Institute of Eye Diseases in National Journal glaucoma
- Vol. 24 (2) , 29-39
Open AccessAnterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma
PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma.METHODS. The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed.RESULTS. In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP).The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP.The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length.CONCLUSION. The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.
- Open Access
- 4 January 2022
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 14 (4) , 172-178
Adverse ocular effects of neuroleptic therapy: semiotics, pathogenesis and treatment
Antipsychotics are widely used in psychiatric practice for treating schizophrenia, bipolar disorder, and other diseases, including those treated off-label. They manifest many adverse effects, including ophthalmic ones. Some of these effects, such as persistent mydriasis, cycloplegia, extraocular muscle dystonia, and visual hypersensitivity attacks are reversible, since they disappear after dose reduction or drug withdrawal. Yet other side effects, such as cataracts, corneal edema, acute angle closure glaucoma and retinopathy are threatening for sight and may lead to permanent visual acuity decline and even blindness. The review provides data on the incidence of ocular side effects (both typical and atypical) of multiple antipsychotics, their clinical manifestations, pathogenesis and treatment. Eye examination is recommended for patients taking antipsychotics in the early periods of treatment and then twice a year. The psychiatrists need to know about the adverse effects of individual drugs whilst the ophthalmologists should be aware of their semiotics, pathogenesis and treatment, since timely diagnosis and treatment of pathological changes, together with antipsychotic therapy modification, prevent the development of severe and irreversible visual impairment in the majority of cases.
- 4 January 2022
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 14 (4) , 172-178
Open AccessAdverse ocular effects of neuroleptic therapy: semiotics, pathogenesis and treatment
Antipsychotics are widely used in psychiatric practice for treating schizophrenia, bipolar disorder, and other diseases, including those treated off-label. They manifest many adverse effects, including ophthalmic ones. Some of these effects, such as persistent mydriasis, cycloplegia, extraocular muscle dystonia, and visual hypersensitivity attacks are reversible, since they disappear after dose reduction or drug withdrawal. Yet other side effects, such as cataracts, corneal edema, acute angle closure glaucoma and retinopathy are threatening for sight and may lead to permanent visual acuity decline and even blindness. The review provides data on the incidence of ocular side effects (both typical and atypical) of multiple antipsychotics, their clinical manifestations, pathogenesis and treatment. Eye examination is recommended for patients taking antipsychotics in the early periods of treatment and then twice a year. The psychiatrists need to know about the adverse effects of individual drugs whilst the ophthalmologists should be aware of their semiotics, pathogenesis and treatment, since timely diagnosis and treatment of pathological changes, together with antipsychotic therapy modification, prevent the development of severe and irreversible visual impairment in the majority of cases.
- Open Access
- 12 December 2021
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 23 (4) , 23-30
Pathogenesis of Increased Intraocular Pressure in Primary Open‑Angle Glaucoma: Literature Review
Introduction. Despite the high socio-economic significance of primary open-angle glaucoma (POAG), the etiotropic and pathogenetic treatment of this disorder has not yet been implemented, since the mechanisms of the development of this disease are not fully known and understood. One of the topical issues is the pathogenesis of ophthalmic hypertension in POAG.Purpose. To summarize the currently known mechanisms of ophthalmic hypertension in POAG to search for potential molecular targets for pathogenetic pharmacotherapy.Materials and methods. Analysis of publications on PubMed, Medline and eLibrary.Results. Ophthalmic hypertension in POAG emerges due to increased resistance to aqueous humor (AH) outflow. It is caused by increased stiffness of Schlemm’s canal endothelium and trabecular meshwork as a result of changes in the structure and biomechanical properties of its cells and extracellular matrix. These changes are determined by the interaction of signaling molecules in the form of a pathological circle, the main links of which are TGF-β2 and its receptor, Smad 2/3/4, YAP/TAZ, sFRP-1 and CTGF.Conclusion. The cause of ophthalmic hypertension in POAG is fibrosis of the trabecular meshwork. This pathological process is based on the interaction of proteins, the main of which are TGF-β2 and its receptor, Smad 2/3/4, YAP/TAZ, sFRP-1 and CTGF. These molecules can become promising targets for the pathogenetic pharmacological therapy of POAG.
- 12 December 2021
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 23 (4) , 23-30
Open AccessPathogenesis of Increased Intraocular Pressure in Primary Open‑Angle Glaucoma: Literature Review
Introduction. Despite the high socio-economic significance of primary open-angle glaucoma (POAG), the etiotropic and pathogenetic treatment of this disorder has not yet been implemented, since the mechanisms of the development of this disease are not fully known and understood. One of the topical issues is the pathogenesis of ophthalmic hypertension in POAG.Purpose. To summarize the currently known mechanisms of ophthalmic hypertension in POAG to search for potential molecular targets for pathogenetic pharmacotherapy.Materials and methods. Analysis of publications on PubMed, Medline and eLibrary.Results. Ophthalmic hypertension in POAG emerges due to increased resistance to aqueous humor (AH) outflow. It is caused by increased stiffness of Schlemm’s canal endothelium and trabecular meshwork as a result of changes in the structure and biomechanical properties of its cells and extracellular matrix. These changes are determined by the interaction of signaling molecules in the form of a pathological circle, the main links of which are TGF-β2 and its receptor, Smad 2/3/4, YAP/TAZ, sFRP-1 and CTGF.Conclusion. The cause of ophthalmic hypertension in POAG is fibrosis of the trabecular meshwork. This pathological process is based on the interaction of proteins, the main of which are TGF-β2 and its receptor, Smad 2/3/4, YAP/TAZ, sFRP-1 and CTGF. These molecules can become promising targets for the pathogenetic pharmacological therapy of POAG.
- 1 January 2013
- Published by Akademizdatcenter Nauka
- Vol. 2013 (5) , 574-582
Гистологическое строение трехчастных грибовидных тел жужелиц (Insecta, Coleoptera: Carabidae)
- 1 January 2013
- Published by Akademizdatcenter Nauka
- Vol. 2013 (5) , 574-582
Гистологическое строение трехчастных грибовидных тел жужелиц (Insecta, Coleoptera: Carabidae)