Zhi Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhi Cheng has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Lan Liu
6 shared publicationsZhijun Cheng
6 shared publications- Xinrong Cheng
School of Science, North University of China, Taiyuan 030051, China
4 shared publications - Lan Liu
School of Science, North University of China, Taiyuan 030051, China
3 shared publications - Zhe Ma
School of Science, North University of China, Taiyuan 030051, China
3 shared publications Hua Hou
Professor, School of Materials Science and Engineering, North Univ. of China, Taiyuan 030051, China
2 shared publications
Latest Publications
- Open Access
Analysis of Mesostructure Characteristics and Clogging Mechanism of Pervious Concrete Based on CT Scanning and Image Processing Techniques
This study utilized CT scanning and image processing techniques to extract and analyze the internal mesostructure and cement paste distribution of porous concrete. The effects of the mesostructure and cement paste distribution on the compressive strength and permeability were studied. Additionally, the research explored the blockage mechanisms and morphology in porous concrete, with CT scanning used to map the distribution of blockages within the material. The results indicate that the impact of the aggregate particle size on the compressive strength is much less significant than the effect of porosity. The images clearly show that the pore size is positively correlated with both porosity and aggregate size. Additionally, the distributions of pore size and cement paste thickness can be described using a lognormal distribution function and a two-parameter Weibull function, respectively. Blockage analysis revealed that the blockages were primarily concentrated within the top 0–30 mm of the porous concrete surface. As the pore size increases, the blockage depth increases, and blockages in the 10–30 mm range are challenging to remove with high-pressure water jets. A degradation model for the permeability performance of aggregate porous concrete, considering blockage consolidation, was established using parameters such as the blockage accumulation per unit area, aggregate particle size, and concrete porosity. This model provides theoretical and data-based references for evaluating the service life of porous concrete.
Open AccessAnalysis of Mesostructure Characteristics and Clogging Mechanism of Pervious Concrete Based on CT Scanning and Image Processing Techniques
This study utilized CT scanning and image processing techniques to extract and analyze the internal mesostructure and cement paste distribution of porous concrete. The effects of the mesostructure and cement paste distribution on the compressive strength and permeability were studied. Additionally, the research explored the blockage mechanisms and morphology in porous concrete, with CT scanning used to map the distribution of blockages within the material. The results indicate that the impact of the aggregate particle size on the compressive strength is much less significant than the effect of porosity. The images clearly show that the pore size is positively correlated with both porosity and aggregate size. Additionally, the distributions of pore size and cement paste thickness can be described using a lognormal distribution function and a two-parameter Weibull function, respectively. Blockage analysis revealed that the blockages were primarily concentrated within the top 0–30 mm of the porous concrete surface. As the pore size increases, the blockage depth increases, and blockages in the 10–30 mm range are challenging to remove with high-pressure water jets. A degradation model for the permeability performance of aggregate porous concrete, considering blockage consolidation, was established using parameters such as the blockage accumulation per unit area, aggregate particle size, and concrete porosity. This model provides theoretical and data-based references for evaluating the service life of porous concrete.
- 31 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Properties and hydration mechanism of slow-setting and expansive cement based on CFB ash and slag
- 31 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Properties and hydration mechanism of slow-setting and expansive cement based on CFB ash and slag
- 30 September 2022
- Published by Springer Nature in Silicon
- Vol. 15 (4) , 1835-1846
Mechanical, Structural and Microstructural Properties of CFB Desulfurization Slag and Silico-Manganese Slag Based-Geopolymer Pastes
- 30 September 2022
- Published by Springer Nature in Silicon
- Vol. 15 (4) , 1835-1846
Mechanical, Structural and Microstructural Properties of CFB Desulfurization Slag and Silico-Manganese Slag Based-Geopolymer Pastes
- Open Access
Axial Compressive Properties of Self-Compacting Concrete Filled Steel Tube Short Columns with Ground Desulfurization Slag
Desulfurization slag (DS) is the solid waste discharged from the bottom of the circulating fluidized bed (CFB) boiler. It has good pozzolanic activity, self-hardening property and large expansibility. In this paper, ground desulfurization slag (GDS) is used as mineral admixture to replace cement to prepare self-compacting concrete (SCC). In order to find out the influence laws of different factors on the axial compressive properties of the self-compacting concrete filled steel tube (CFST), seven types of SCC are prepared and nine groups of CFST short column are fabricated. Filling ability test, compressive strength test and axial compressive test are performed. The filling ability and the compressive strength of the SCCs are investigated, and the axial compressive properties of the CFSTs are researched. The results show that the amount of polycarboxylate superplasticizer (PS) increases with the amount of GDS, and the addition of GDS decreases the 3d, 7d and 28d compressive strength of the SCCs. The optimum amount of GDS for SCCs and CFSTs is 30%. When the amount of GDS is 30%, the ultimate bearing capacity of CFST short column (GP3) is the highest, which is 33.6% higher than that of GP1 without GDS. The influence law of the GDS’s amount on the CFSTs’ ultimate bearing capacity is quite different from that of the GDS’s amount on the SCCs’ compressive strength. The ultimate bearing capacity of CFSTs can be significantly improved by adding GDS. Sodium sulfate can improve both the compressive strength of the SCC and the bearing capacity of the CFST.
Open AccessAxial Compressive Properties of Self-Compacting Concrete Filled Steel Tube Short Columns with Ground Desulfurization Slag
Desulfurization slag (DS) is the solid waste discharged from the bottom of the circulating fluidized bed (CFB) boiler. It has good pozzolanic activity, self-hardening property and large expansibility. In this paper, ground desulfurization slag (GDS) is used as mineral admixture to replace cement to prepare self-compacting concrete (SCC). In order to find out the influence laws of different factors on the axial compressive properties of the self-compacting concrete filled steel tube (CFST), seven types of SCC are prepared and nine groups of CFST short column are fabricated. Filling ability test, compressive strength test and axial compressive test are performed. The filling ability and the compressive strength of the SCCs are investigated, and the axial compressive properties of the CFSTs are researched. The results show that the amount of polycarboxylate superplasticizer (PS) increases with the amount of GDS, and the addition of GDS decreases the 3d, 7d and 28d compressive strength of the SCCs. The optimum amount of GDS for SCCs and CFSTs is 30%. When the amount of GDS is 30%, the ultimate bearing capacity of CFST short column (GP3) is the highest, which is 33.6% higher than that of GP1 without GDS. The influence law of the GDS’s amount on the CFSTs’ ultimate bearing capacity is quite different from that of the GDS’s amount on the SCCs’ compressive strength. The ultimate bearing capacity of CFSTs can be significantly improved by adding GDS. Sodium sulfate can improve both the compressive strength of the SCC and the bearing capacity of the CFST.
- Open Access
Strength Tests and Numerical Simulations of Loess Modified by Desulfurization Ash and Fly Ash
Desulfurization ash and fly ash are solid wastes discharged from boilers of power plants. Their utilization rate is low, especially desulfurization ash, most of which is stored. In order to realize their resource utilization, they are used to modify loess in this paper. Nine group compaction tests and 32 group direct shear tests are done in order to explore the influence law of desulfurization ash and fly ash on the strength of the loess. Meanwhile, FLAC3D software is used to numerically simulate the direct shear test, and the simulation results and the test results are compared and analyzed. The results show that, with the increase of desulfurization ash’s amount, the shear strength of the modified loess increases first and then decreases. The loess modified by the fly ash has the same law with that of the desulfurization ash. The best mass ratio of modified loess is 80:20. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 12.74% higher than that of the pure loess on average and the shear strength of loess modified by fly ash is 3.59% higher than that of the pure loess on average. The effect of the desulfurization ash on modifying the loess is better than that of the fly ash. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 9.15% higher than that of the fly ash on average. Comparing the results of the simulation calculation with the actual test results, the increase rate of the shear stress of the FLAC3D simulation is larger than that of the actual test, and the simulated shear strength is about 8.21% higher than the test shear strength.
Open AccessStrength Tests and Numerical Simulations of Loess Modified by Desulfurization Ash and Fly Ash
Desulfurization ash and fly ash are solid wastes discharged from boilers of power plants. Their utilization rate is low, especially desulfurization ash, most of which is stored. In order to realize their resource utilization, they are used to modify loess in this paper. Nine group compaction tests and 32 group direct shear tests are done in order to explore the influence law of desulfurization ash and fly ash on the strength of the loess. Meanwhile, FLAC3D software is used to numerically simulate the direct shear test, and the simulation results and the test results are compared and analyzed. The results show that, with the increase of desulfurization ash’s amount, the shear strength of the modified loess increases first and then decreases. The loess modified by the fly ash has the same law with that of the desulfurization ash. The best mass ratio of modified loess is 80:20. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 12.74% higher than that of the pure loess on average and the shear strength of loess modified by fly ash is 3.59% higher than that of the pure loess on average. The effect of the desulfurization ash on modifying the loess is better than that of the fly ash. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 9.15% higher than that of the fly ash on average. Comparing the results of the simulation calculation with the actual test results, the increase rate of the shear stress of the FLAC3D simulation is larger than that of the actual test, and the simulated shear strength is about 8.21% higher than the test shear strength.
- Open Access
Interface Bonding Behavior of Concrete-Filled Steel Tube Blended with Circulating Fluidized Bed Bottom Ash
The interface bonding behavior between the steel tube and the concrete of concrete-filled steel tube (CFST) blended with circulating fluidized bed bottom ash (CFB-BA) was investigated in this study. A total of 8 groups of CFSTs stub columns were prepared with different dosage of CFB-BA, water-binder ratio (W/B), and interface bonding length. A series of push-out tests were carried out to acquire the data representing the interface bonding behavior. The results show that the dosage of CFB-BA has a direct effect on interface bonding behavior of CFST. CFB-BA can improve the interface bonding behavior of CFST. The highest ultimate bonding load and strength are achieved when the dosage of CFB-BA is 30%. When the dosage of CFB-BA increases to 50%, its interface bonding behavior decreases, but is still better than that of CFST without CFB-BA. W/B has a negative correlation with the interface bonding behavior of CFST. While the W/B increases, the interface bonding load and strength of CFST decreases. The increase of the interface bonding length can improve the interface bonding load, but cannot improve the interface bonding strength.
Open AccessInterface Bonding Behavior of Concrete-Filled Steel Tube Blended with Circulating Fluidized Bed Bottom Ash
The interface bonding behavior between the steel tube and the concrete of concrete-filled steel tube (CFST) blended with circulating fluidized bed bottom ash (CFB-BA) was investigated in this study. A total of 8 groups of CFSTs stub columns were prepared with different dosage of CFB-BA, water-binder ratio (W/B), and interface bonding length. A series of push-out tests were carried out to acquire the data representing the interface bonding behavior. The results show that the dosage of CFB-BA has a direct effect on interface bonding behavior of CFST. CFB-BA can improve the interface bonding behavior of CFST. The highest ultimate bonding load and strength are achieved when the dosage of CFB-BA is 30%. When the dosage of CFB-BA increases to 50%, its interface bonding behavior decreases, but is still better than that of CFST without CFB-BA. W/B has a negative correlation with the interface bonding behavior of CFST. While the W/B increases, the interface bonding load and strength of CFST decreases. The increase of the interface bonding length can improve the interface bonding load, but cannot improve the interface bonding strength.
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Mechanical Properties and Durability of High‐Performance Concretes Blended with Circulating Fluidized Bed Combustion Ash and Slag as Replacement for Ordinary Portland Cement
This study investigates the mechanical properties and durability of three families of high‐performance concrete (HPC), in which the first was blended with fly ash, the second with circulating fluidized bed combustion (CFBC) ash, and the third with CFBC slag. In addition to each of the three mineral additives, silica fume and a superplasticizer were also incorporated into the HPC. Hence, three families of HPC, containing 10%, 20%, and 30% mineral admixtures and 9% silica fume of the binder mass, respectively, were produced. The microstructure and hydration products of the HPC families were examined by scanning electron microscopy (SEM) and X‐ray diffraction (XRD) to explore the influence of fly ash, CFBC ash, and CFBC slag on the compressive strength and frost resistance of HPC. The experimental results show that the compressive strength of HPC could reach 60 MPa at 28 d age. When the fly ash content was 30%, the compressive strength of HPC was 70.2 MPa at 28 d age; after the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.63% and 8.9%, respectively. When the CFBC ash content was 20%, the compressive strength of HPC was 75 MPa at 28 d age. After the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.17% and 0.81%, respectively.
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Open AccessMechanical Properties and Durability of High‐Performance Concretes Blended with Circulating Fluidized Bed Combustion Ash and Slag as Replacement for Ordinary Portland Cement
This study investigates the mechanical properties and durability of three families of high‐performance concrete (HPC), in which the first was blended with fly ash, the second with circulating fluidized bed combustion (CFBC) ash, and the third with CFBC slag. In addition to each of the three mineral additives, silica fume and a superplasticizer were also incorporated into the HPC. Hence, three families of HPC, containing 10%, 20%, and 30% mineral admixtures and 9% silica fume of the binder mass, respectively, were produced. The microstructure and hydration products of the HPC families were examined by scanning electron microscopy (SEM) and X‐ray diffraction (XRD) to explore the influence of fly ash, CFBC ash, and CFBC slag on the compressive strength and frost resistance of HPC. The experimental results show that the compressive strength of HPC could reach 60 MPa at 28 d age. When the fly ash content was 30%, the compressive strength of HPC was 70.2 MPa at 28 d age; after the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.63% and 8.9%, respectively. When the CFBC ash content was 20%, the compressive strength of HPC was 75 MPa at 28 d age. After the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.17% and 0.81%, respectively.