Zhe Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhe Ma has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Zhi Cheng
School of Science, North University of China, Taiyuan 030051, China
3 shared publications - Xinrong Cheng
School of Science, North University of China, Taiyuan 030051, China
2 shared publications - Lan Liu
School of Science, North University of China, Taiyuan 030051, China
1 shared publication - Lan Liu
School of Environment and Safety Engineering, North University of China, Taiyuan 030051, China
1 shared publication - Lei He
Exploration and Development Research Institute, PetroChina Changqing Oilfield Company, Xi’an, Shaanxi, 710018, China
1 shared publication - Taidong Guo
School of Environment and Safety Engineering, North University of China, Taiyuan 030051, China
1 shared publication
Latest Publications
- Open Access
Analysis of Mesostructure Characteristics and Clogging Mechanism of Pervious Concrete Based on CT Scanning and Image Processing Techniques
This study utilized CT scanning and image processing techniques to extract and analyze the internal mesostructure and cement paste distribution of porous concrete. The effects of the mesostructure and cement paste distribution on the compressive strength and permeability were studied. Additionally, the research explored the blockage mechanisms and morphology in porous concrete, with CT scanning used to map the distribution of blockages within the material. The results indicate that the impact of the aggregate particle size on the compressive strength is much less significant than the effect of porosity. The images clearly show that the pore size is positively correlated with both porosity and aggregate size. Additionally, the distributions of pore size and cement paste thickness can be described using a lognormal distribution function and a two-parameter Weibull function, respectively. Blockage analysis revealed that the blockages were primarily concentrated within the top 0–30 mm of the porous concrete surface. As the pore size increases, the blockage depth increases, and blockages in the 10–30 mm range are challenging to remove with high-pressure water jets. A degradation model for the permeability performance of aggregate porous concrete, considering blockage consolidation, was established using parameters such as the blockage accumulation per unit area, aggregate particle size, and concrete porosity. This model provides theoretical and data-based references for evaluating the service life of porous concrete.
Open AccessAnalysis of Mesostructure Characteristics and Clogging Mechanism of Pervious Concrete Based on CT Scanning and Image Processing Techniques
This study utilized CT scanning and image processing techniques to extract and analyze the internal mesostructure and cement paste distribution of porous concrete. The effects of the mesostructure and cement paste distribution on the compressive strength and permeability were studied. Additionally, the research explored the blockage mechanisms and morphology in porous concrete, with CT scanning used to map the distribution of blockages within the material. The results indicate that the impact of the aggregate particle size on the compressive strength is much less significant than the effect of porosity. The images clearly show that the pore size is positively correlated with both porosity and aggregate size. Additionally, the distributions of pore size and cement paste thickness can be described using a lognormal distribution function and a two-parameter Weibull function, respectively. Blockage analysis revealed that the blockages were primarily concentrated within the top 0–30 mm of the porous concrete surface. As the pore size increases, the blockage depth increases, and blockages in the 10–30 mm range are challenging to remove with high-pressure water jets. A degradation model for the permeability performance of aggregate porous concrete, considering blockage consolidation, was established using parameters such as the blockage accumulation per unit area, aggregate particle size, and concrete porosity. This model provides theoretical and data-based references for evaluating the service life of porous concrete.
- Open Access
Strength Tests and Numerical Simulations of Loess Modified by Desulfurization Ash and Fly Ash
Desulfurization ash and fly ash are solid wastes discharged from boilers of power plants. Their utilization rate is low, especially desulfurization ash, most of which is stored. In order to realize their resource utilization, they are used to modify loess in this paper. Nine group compaction tests and 32 group direct shear tests are done in order to explore the influence law of desulfurization ash and fly ash on the strength of the loess. Meanwhile, FLAC3D software is used to numerically simulate the direct shear test, and the simulation results and the test results are compared and analyzed. The results show that, with the increase of desulfurization ash’s amount, the shear strength of the modified loess increases first and then decreases. The loess modified by the fly ash has the same law with that of the desulfurization ash. The best mass ratio of modified loess is 80:20. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 12.74% higher than that of the pure loess on average and the shear strength of loess modified by fly ash is 3.59% higher than that of the pure loess on average. The effect of the desulfurization ash on modifying the loess is better than that of the fly ash. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 9.15% higher than that of the fly ash on average. Comparing the results of the simulation calculation with the actual test results, the increase rate of the shear stress of the FLAC3D simulation is larger than that of the actual test, and the simulated shear strength is about 8.21% higher than the test shear strength.
Open AccessStrength Tests and Numerical Simulations of Loess Modified by Desulfurization Ash and Fly Ash
Desulfurization ash and fly ash are solid wastes discharged from boilers of power plants. Their utilization rate is low, especially desulfurization ash, most of which is stored. In order to realize their resource utilization, they are used to modify loess in this paper. Nine group compaction tests and 32 group direct shear tests are done in order to explore the influence law of desulfurization ash and fly ash on the strength of the loess. Meanwhile, FLAC3D software is used to numerically simulate the direct shear test, and the simulation results and the test results are compared and analyzed. The results show that, with the increase of desulfurization ash’s amount, the shear strength of the modified loess increases first and then decreases. The loess modified by the fly ash has the same law with that of the desulfurization ash. The best mass ratio of modified loess is 80:20. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 12.74% higher than that of the pure loess on average and the shear strength of loess modified by fly ash is 3.59% higher than that of the pure loess on average. The effect of the desulfurization ash on modifying the loess is better than that of the fly ash. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 9.15% higher than that of the fly ash on average. Comparing the results of the simulation calculation with the actual test results, the increase rate of the shear stress of the FLAC3D simulation is larger than that of the actual test, and the simulated shear strength is about 8.21% higher than the test shear strength.
- Open Access
Interface Bonding Behavior of Concrete-Filled Steel Tube Blended with Circulating Fluidized Bed Bottom Ash
The interface bonding behavior between the steel tube and the concrete of concrete-filled steel tube (CFST) blended with circulating fluidized bed bottom ash (CFB-BA) was investigated in this study. A total of 8 groups of CFSTs stub columns were prepared with different dosage of CFB-BA, water-binder ratio (W/B), and interface bonding length. A series of push-out tests were carried out to acquire the data representing the interface bonding behavior. The results show that the dosage of CFB-BA has a direct effect on interface bonding behavior of CFST. CFB-BA can improve the interface bonding behavior of CFST. The highest ultimate bonding load and strength are achieved when the dosage of CFB-BA is 30%. When the dosage of CFB-BA increases to 50%, its interface bonding behavior decreases, but is still better than that of CFST without CFB-BA. W/B has a negative correlation with the interface bonding behavior of CFST. While the W/B increases, the interface bonding load and strength of CFST decreases. The increase of the interface bonding length can improve the interface bonding load, but cannot improve the interface bonding strength.
Open AccessInterface Bonding Behavior of Concrete-Filled Steel Tube Blended with Circulating Fluidized Bed Bottom Ash
The interface bonding behavior between the steel tube and the concrete of concrete-filled steel tube (CFST) blended with circulating fluidized bed bottom ash (CFB-BA) was investigated in this study. A total of 8 groups of CFSTs stub columns were prepared with different dosage of CFB-BA, water-binder ratio (W/B), and interface bonding length. A series of push-out tests were carried out to acquire the data representing the interface bonding behavior. The results show that the dosage of CFB-BA has a direct effect on interface bonding behavior of CFST. CFB-BA can improve the interface bonding behavior of CFST. The highest ultimate bonding load and strength are achieved when the dosage of CFB-BA is 30%. When the dosage of CFB-BA increases to 50%, its interface bonding behavior decreases, but is still better than that of CFST without CFB-BA. W/B has a negative correlation with the interface bonding behavior of CFST. While the W/B increases, the interface bonding load and strength of CFST decreases. The increase of the interface bonding length can improve the interface bonding load, but cannot improve the interface bonding strength.