Daniel Tam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Tam has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Marie-Eve Aubin-Tam
Department of Bionanoscience, Kavli Institute of Nanoscience, Delft University of Technology, Delft, The Netherlands
8 shared publications A. E. Hosoi
Department of Mechanical Engineering, Massachusetts Institute of Technology, Massachusetts 02139, USA
4 shared publicationsAbel-John Buchner
Process & Energy, ME, TU Delft, Delft, The Netherlands
2 shared publications- Anette E. Hosoi
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
2 shared publications Da Wei
Department of Bionanoscience, Kavli Institute of Nanoscience, Delft University of Technology, Delft, The Netherlands
2 shared publications- Da Wei
Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences
2 shared publications
Latest Publications
- Open Access
- 28 March 2025
- Published by Springer Nature in Experiments in Fluids
- Vol. 66 (4) , 1-18
Three-dimensional tracking of microswimmer suspensions
Understanding the locomotion of microorganisms is essential for insights into microbial ecology, infection, and colonization processes. Although two-dimensional microscopy has been widely used to study microswimmer motility, it does not capture the full extent of their three-dimensional (3D) movement. Recent advances in defocused particle tracking, holographic tracking velocimetry, and stereo-microscopy face challenges in achieving high resolution at larger particle densities and tracking multiple microswimmers in suspension. In this work, we introduce a novel multi-camera microscopy system that significantly improves the accuracy of 3D microswimmer tracking. Our system uses four sCMOS cameras to image microorganisms within a 2.5 $$\times$$ 2.5 $$\times$$ 2 mm $$^3$$ . We assess the performance of our microscopy system by tracking a population of the unicellular motile algae Chlamydomonas reinhardtii. An in-house tracking algorithm based on the projective geometry framework enables tracking with reprojection errors below 0.3 body lengths. This system supports imaging and tracking particle source densities of 0.32, higher than other existing single camera 3D microscopy techniques. Analysis of C. reinhardtii trajectories in 3D reveals a predominance of left-handed chirality and helical swimming patterns. Moreover, our 3D tracking data provide translational and rotational diffusion coefficients that differ from those obtained using traditional two-dimensional methods.- 28 March 2025
- Published by Springer Nature in Experiments in Fluids
- Vol. 66 (4) , 1-18
Open AccessThree-dimensional tracking of microswimmer suspensions
Understanding the locomotion of microorganisms is essential for insights into microbial ecology, infection, and colonization processes. Although two-dimensional microscopy has been widely used to study microswimmer motility, it does not capture the full extent of their three-dimensional (3D) movement. Recent advances in defocused particle tracking, holographic tracking velocimetry, and stereo-microscopy face challenges in achieving high resolution at larger particle densities and tracking multiple microswimmers in suspension. In this work, we introduce a novel multi-camera microscopy system that significantly improves the accuracy of 3D microswimmer tracking. Our system uses four sCMOS cameras to image microorganisms within a 2.5 $$\times$$ 2.5 $$\times$$ 2 mm $$^3$$ . We assess the performance of our microscopy system by tracking a population of the unicellular motile algae Chlamydomonas reinhardtii. An in-house tracking algorithm based on the projective geometry framework enables tracking with reprojection errors below 0.3 body lengths. This system supports imaging and tracking particle source densities of 0.32, higher than other existing single camera 3D microscopy techniques. Analysis of C. reinhardtii trajectories in 3D reveals a predominance of left-handed chirality and helical swimming patterns. Moreover, our 3D tracking data provide translational and rotational diffusion coefficients that differ from those obtained using traditional two-dimensional methods. - Open Access
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Particle manipulation in Hele–Shaw flow with programmable hydrodynamics
This paper presents a microfluidic approach that dynamically controls the hydrodynamic flow and the streamlines to enable complex multi-particle manipulations within a single device. The approach combines the design of a flow-through microfluidic Hele–Shaw flow cell together with an optimization procedure to find a priori optimal particle pathlines, and an effective proportional–integral–derivative (PID) feedback controller to provide real-time control over the particle manipulations. In the device, particles are manipulated with hydrodynamic forces, by using a uniform flow through the flow cell and three inlets perpendicular to the flow cell. The streamlines within the device are manipulated by injecting or extracting fluid through the three inlets. The Hele–Shaw geometry allows a fast and accurate prediction of the particle trajectory, meaning only a simple PID controller is required to correct for particle deviations. The robustness of this approach is demonstrated by implementing multiple functions within the device, including particle trapping, particle sorting, particle separation, and assembly. The real-time control procedure affords accurate particle manipulation, with a maximum error on the order of the diameter of the particle.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Open AccessParticle manipulation in Hele–Shaw flow with programmable hydrodynamics
This paper presents a microfluidic approach that dynamically controls the hydrodynamic flow and the streamlines to enable complex multi-particle manipulations within a single device. The approach combines the design of a flow-through microfluidic Hele–Shaw flow cell together with an optimization procedure to find a priori optimal particle pathlines, and an effective proportional–integral–derivative (PID) feedback controller to provide real-time control over the particle manipulations. In the device, particles are manipulated with hydrodynamic forces, by using a uniform flow through the flow cell and three inlets perpendicular to the flow cell. The streamlines within the device are manipulated by injecting or extracting fluid through the three inlets. The Hele–Shaw geometry allows a fast and accurate prediction of the particle trajectory, meaning only a simple PID controller is required to correct for particle deviations. The robustness of this approach is demonstrated by implementing multiple functions within the device, including particle trapping, particle sorting, particle separation, and assembly. The real-time control procedure affords accurate particle manipulation, with a maximum error on the order of the diameter of the particle.
- Open Access
- 17 October 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (42) , 8524-8537
Mechanical characterization of freestanding lipid bilayers with temperature-controlled phase
Lipid membranes formed in a microfluidic device are studied with temperature-controlled optical tweezers, revealing how mechanical properties of ripple phase and gel-fluid phase-separated membranes change when heated above the transition temperature.
- 17 October 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (42) , 8524-8537
Open AccessMechanical characterization of freestanding lipid bilayers with temperature-controlled phase
Lipid membranes formed in a microfluidic device are studied with temperature-controlled optical tweezers, revealing how mechanical properties of ripple phase and gel-fluid phase-separated membranes change when heated above the transition temperature.
- Open Access
- 25 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (41) , 42278-42288
High-Speed Imaging of Giant Unilamellar Vesicle Formation in cDICE
Giant unilamellar vesicles (GUVs) are widely used as in vitro model membranes in biophysics and as cell-sized containers in synthetic biology. Despite their ubiquitous use, there is no one-size-fits-all method for their production. Numerous methods have been developed to meet the demanding requirements of reproducibility, reliability, and high yield while simultaneously achieving robust encapsulation. Emulsion-based methods are often praised for their apparent simplicity and good yields; hence, methods like continuous droplet interface crossing encapsulation (cDICE), which make use of this principle, have gained popularity. However, the underlying physical principles governing the formation of GUVs in cDICE and related methods remain poorly understood. To this end, we have developed a high-speed microscopy setup that allows us to visualize GUV formation in real time. Our experiments reveal a complex droplet formation process occurring at the capillary orifice, generating >30 μm-sized droplets and only in some cases GUV-sized (∼15 μm) satellite droplets. According to existing theoretical models, the oil-water interface should allow for the crossing of all droplets, but based on our observations and scaling arguments on the fluid dynamics within the system, we find a size-selective crossing of GUV-sized droplets only. The origin of these droplets remains partly unclear; we hypothesize that some small GUVs might be formed from large droplets sitting at the second interface. Finally, we demonstrate that proteins in the inner solution affect GUV formation by increasing the viscosity and altering the lipid adsorption kinetics. These results will not only contribute to a better understanding of GUV formation processes in cDICE but ultimately also aid in the development of more reliable and efficient methods for GUV production.
- 25 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (41) , 42278-42288
Open AccessHigh-Speed Imaging of Giant Unilamellar Vesicle Formation in cDICE
Giant unilamellar vesicles (GUVs) are widely used as in vitro model membranes in biophysics and as cell-sized containers in synthetic biology. Despite their ubiquitous use, there is no one-size-fits-all method for their production. Numerous methods have been developed to meet the demanding requirements of reproducibility, reliability, and high yield while simultaneously achieving robust encapsulation. Emulsion-based methods are often praised for their apparent simplicity and good yields; hence, methods like continuous droplet interface crossing encapsulation (cDICE), which make use of this principle, have gained popularity. However, the underlying physical principles governing the formation of GUVs in cDICE and related methods remain poorly understood. To this end, we have developed a high-speed microscopy setup that allows us to visualize GUV formation in real time. Our experiments reveal a complex droplet formation process occurring at the capillary orifice, generating >30 μm-sized droplets and only in some cases GUV-sized (∼15 μm) satellite droplets. According to existing theoretical models, the oil-water interface should allow for the crossing of all droplets, but based on our observations and scaling arguments on the fluid dynamics within the system, we find a size-selective crossing of GUV-sized droplets only. The origin of these droplets remains partly unclear; we hypothesize that some small GUVs might be formed from large droplets sitting at the second interface. Finally, we demonstrate that proteins in the inner solution affect GUV formation by increasing the viscosity and altering the lipid adsorption kinetics. These results will not only contribute to a better understanding of GUV formation processes in cDICE but ultimately also aid in the development of more reliable and efficient methods for GUV production.
- Open Access
- 16 May 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
The younger flagellum sets the beat for Chlamydomonas reinhardtii
Eukaryotes swim with coordinated flagellar (ciliary) beating and steer by fine-tuning the coordination. The model organism for studying flagellate motility, Chlamydomonas reinhardtii, employs synchronous, breaststroke-like flagellar beating to swim, and it modulates the beating amplitudes differentially to steer. This strategy hinges on both inherent flagellar asymmetries (e.g. different response to chemical messengers) and such asymmetries being effectively coordinated in the synchronous beating. In C. reinhardtii, the synchrony of beating is known to be supported by a mechanical connection between flagella; however, how flagellar asymmetries persist in the synchrony remains elusive. For example, it has been speculated for decades that one flagellum leads the beating, as its dynamic properties (i.e. frequency, waveform, etc.) appear to be copied by the other one. In this study, we combine experiments, computations, and modeling efforts to elucidate the roles played by each flagellum in synchronous beating. With a non-invasive technique to selectively load each flagellum, we show that the coordinated beating essentially only responds to load exerted on the cis flagellum; and that such asymmetry in response derives from a unilateral coupling between the two flagella. Our results highlight a distinct role for each flagellum in coordination and have implication for biflagellates’ tactic behaviors.
- 16 May 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Open AccessThe younger flagellum sets the beat for Chlamydomonas reinhardtii
Eukaryotes swim with coordinated flagellar (ciliary) beating and steer by fine-tuning the coordination. The model organism for studying flagellate motility, Chlamydomonas reinhardtii, employs synchronous, breaststroke-like flagellar beating to swim, and it modulates the beating amplitudes differentially to steer. This strategy hinges on both inherent flagellar asymmetries (e.g. different response to chemical messengers) and such asymmetries being effectively coordinated in the synchronous beating. In C. reinhardtii, the synchrony of beating is known to be supported by a mechanical connection between flagella; however, how flagellar asymmetries persist in the synchrony remains elusive. For example, it has been speculated for decades that one flagellum leads the beating, as its dynamic properties (i.e. frequency, waveform, etc.) appear to be copied by the other one. In this study, we combine experiments, computations, and modeling efforts to elucidate the roles played by each flagellum in synchronous beating. With a non-invasive technique to selectively load each flagellum, we show that the coordinated beating essentially only responds to load exerted on the cis flagellum; and that such asymmetry in response derives from a unilateral coupling between the two flagella. Our results highlight a distinct role for each flagellum in coordination and have implication for biflagellates’ tactic behaviors.
- Open Access
High-speed imaging of giant unilamellar vesicle formation in cDICE
Giant unilamellar vesicles (GUVs) are widely used as in vitro model membranes in biophysics and as cell-sized containers in synthetic biology. Despite their ubiquitous use, there is no one-size-fits-all method for their production. Numerous methods have been developed to meet the demanding requirements of reproducibility, reliability, and high yield, while simultaneously achieving robust encapsulation. Emulsion-based methods are often praised for their apparent simplicity and good yields; hence, methods like continuous droplet interface crossing encapsulation (cDICE) that make use of this principle, have gained popularity. However, the underlying physical principles governing the formation of GUVs in cDICE and related methods remain poorly understood. To this end, we have developed a high-speed microscopy setup that allows us to visualize GUV formation in real-time. Our experiments reveal a complex droplet formation process occurring at the capillary orifice, generating both larger droplets and, likely, GUV-sized satellite droplets. According to existing theoretical models, the oil-water interface should allow for crossing of all droplets, but based on our observations and theoretical modelling of the fluid dynamics within the system, we find a size-selective crossing of GUV-sized droplets only. Finally, we demonstrate that proteins in the inner solution affect GUV formation by increasing the viscosity and altering lipid adsorption kinetics. These results will not only contribute to a better understanding of GUV formation processes in cDICE, but ultimately also aid the development of more reliable and efficient methods for GUV production. Graphical We developed a high-speed microscopy setup to study giant unilamellar vesicle formation in cDICE, revealing a complex droplet formation process occurring at the capillary orifice and size-selectivity at the oil-water interface.
Open AccessHigh-speed imaging of giant unilamellar vesicle formation in cDICE
Giant unilamellar vesicles (GUVs) are widely used as in vitro model membranes in biophysics and as cell-sized containers in synthetic biology. Despite their ubiquitous use, there is no one-size-fits-all method for their production. Numerous methods have been developed to meet the demanding requirements of reproducibility, reliability, and high yield, while simultaneously achieving robust encapsulation. Emulsion-based methods are often praised for their apparent simplicity and good yields; hence, methods like continuous droplet interface crossing encapsulation (cDICE) that make use of this principle, have gained popularity. However, the underlying physical principles governing the formation of GUVs in cDICE and related methods remain poorly understood. To this end, we have developed a high-speed microscopy setup that allows us to visualize GUV formation in real-time. Our experiments reveal a complex droplet formation process occurring at the capillary orifice, generating both larger droplets and, likely, GUV-sized satellite droplets. According to existing theoretical models, the oil-water interface should allow for crossing of all droplets, but based on our observations and theoretical modelling of the fluid dynamics within the system, we find a size-selective crossing of GUV-sized droplets only. Finally, we demonstrate that proteins in the inner solution affect GUV formation by increasing the viscosity and altering lipid adsorption kinetics. These results will not only contribute to a better understanding of GUV formation processes in cDICE, but ultimately also aid the development of more reliable and efficient methods for GUV production. Graphical We developed a high-speed microscopy setup to study giant unilamellar vesicle formation in cDICE, revealing a complex droplet formation process occurring at the capillary orifice and size-selectivity at the oil-water interface.
- Open Access
- 21 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (21)
Hydrodynamic shear dissipation and transmission in lipid bilayers
Significance: Lipid bilayers constitute the matrix of cellular membranes and synthetic vesicles used in drug delivery. This self-assembled structure is only a few nanometers thick but provides an effective barrier between aqueous fluids. The response of lipid bilayers to shear stresses induced by surrounding fluid flows can trigger biophysical processes in cells and influence the efficacy of drug delivery by synthetic vesicles. Here, we use optical tweezers to apply and measure local hydrodynamic shear stresses on both sides of a freestanding lipid bilayer. With this method, we determine the rheological properties of bilayers and capture a previously unreported phenomenon when the intermonolayer friction is so low that the monolayers slip past each other and hydrodynamic shear is not transmitted through the bilayer.
- 21 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (21)
Open AccessHydrodynamic shear dissipation and transmission in lipid bilayers
Significance: Lipid bilayers constitute the matrix of cellular membranes and synthetic vesicles used in drug delivery. This self-assembled structure is only a few nanometers thick but provides an effective barrier between aqueous fluids. The response of lipid bilayers to shear stresses induced by surrounding fluid flows can trigger biophysical processes in cells and influence the efficacy of drug delivery by synthetic vesicles. Here, we use optical tweezers to apply and measure local hydrodynamic shear stresses on both sides of a freestanding lipid bilayer. With this method, we determine the rheological properties of bilayers and capture a previously unreported phenomenon when the intermonolayer friction is so low that the monolayers slip past each other and hydrodynamic shear is not transmitted through the bilayer.
- Open Access
- 12 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (20)
Hopping trajectories due to long-range interactions determine surface accumulation of microalgae
Significance: How motile cells accumulate on solid surfaces is of crucial importance to phenomena, such as surface colonization, biofilm formation, and biofouling, with biological, medical, ecological, and industrial implications. Cell accumulation and adhesion to a substrate are influenced by different mechanical and physical interactions, including hydrodynamic and steric interactions. Determining their relative contributions to the increase in cell density at solid surfaces is experimentally challenging. Here, a unique multicamera three-dimensional experimental measurement reveals the existence of long-range interactions between green algae Chlamydomonas reinhardtii cells and surfaces, which are directly responsible for the increase of cell density near surfaces. It is our hope that these results will contribute to the design of surfaces to modulate, promote, and inhibit surface adhesion.
- 12 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (20)
Open AccessHopping trajectories due to long-range interactions determine surface accumulation of microalgae
Significance: How motile cells accumulate on solid surfaces is of crucial importance to phenomena, such as surface colonization, biofilm formation, and biofouling, with biological, medical, ecological, and industrial implications. Cell accumulation and adhesion to a substrate are influenced by different mechanical and physical interactions, including hydrodynamic and steric interactions. Determining their relative contributions to the increase in cell density at solid surfaces is experimentally challenging. Here, a unique multicamera three-dimensional experimental measurement reveals the existence of long-range interactions between green algae Chlamydomonas reinhardtii cells and surfaces, which are directly responsible for the increase of cell density near surfaces. It is our hope that these results will contribute to the design of surfaces to modulate, promote, and inhibit surface adhesion.
- Open Access
- 17 March 2021
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 915
Measurements of the unsteady flow field around beating cilia
The swift deformations of flagella and cilia are crucial for locomotion and fluid transport on the micron scale. Most hydrodynamic models of flagellar and ciliary flows assume the zero Reynolds number limit and model the flow using Stokes equations. Recent work has demonstrated that this quasi-steady approximation breaks down at increasing distances from the cilia. Here, we use optical tweezer-based velocimetry to measure the flow velocity with high temporal accuracy, and to reconstruct the entire unsteady flow field around beating cilia. We report both the steady and the unsteady component of the ciliary flow and compare them with the solutions to both the Stokes and the Navier–Stokes equations. Our experimental measurements of the velocity and vorticity fields are in agreement with the numerical solution to the Navier–Stokes equations and show significant differences with the solution to the Stokes equations. We characterize the phase difference between the flow oscillations and the oscillations of the ciliary motion and evidence a significant anisotropic phase lag. We show that this phase lag presents the spatiotemporal characteristics of the unsteady Stokes equations and that the flow field around beating cilia is well represented by the fundamental solution to the unsteady Stokes equations: the oscillet.
- 17 March 2021
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 915
Open AccessMeasurements of the unsteady flow field around beating cilia
The swift deformations of flagella and cilia are crucial for locomotion and fluid transport on the micron scale. Most hydrodynamic models of flagellar and ciliary flows assume the zero Reynolds number limit and model the flow using Stokes equations. Recent work has demonstrated that this quasi-steady approximation breaks down at increasing distances from the cilia. Here, we use optical tweezer-based velocimetry to measure the flow velocity with high temporal accuracy, and to reconstruct the entire unsteady flow field around beating cilia. We report both the steady and the unsteady component of the ciliary flow and compare them with the solutions to both the Stokes and the Navier–Stokes equations. Our experimental measurements of the velocity and vorticity fields are in agreement with the numerical solution to the Navier–Stokes equations and show significant differences with the solution to the Stokes equations. We characterize the phase difference between the flow oscillations and the oscillations of the ciliary motion and evidence a significant anisotropic phase lag. We show that this phase lag presents the spatiotemporal characteristics of the unsteady Stokes equations and that the flow field around beating cilia is well represented by the fundamental solution to the unsteady Stokes equations: the oscillet.
- Open Access
- 28 August 2020
- Published by Springer Nature in Experiments in Fluids
- Vol. 61 (9) , 1-15
Optical tweezers-based velocimetry: a method to measure microscale unsteady flows
In the study of micro-scale biological flows, velocimetry methods based on passive tracers, such as micro-PIV and micro-PTV, are well established to characterize steady flows. However, these methods become inappropriate for measuring unsteady flows of small amplitude, because, on these scales, the motion of passive tracers cannot be distinguished from Brownian motion. In this study, we use optical tweezers (OTs) in combination with Kalman filtering, to measure unsteady microscopic flows with high temporal accuracy. This method is referred to as optical tweezers-based velocimetry (OTV). The OTV method measures the nanometric displacements of a trapped bead, and predicts the instantaneous velocity of the flow by employing a Kalman filter. We discuss the accuracy of OTV in measuring unsteady flows with 1.5–70 $$\upmu$$ m s $$^{-1}$$ amplitudes and 10–90 Hz frequencies. We quantify how the bead size and the laser power affect the velocimetry accuracy, and specify the optimal choices for the bead size and laser power to measure different unsteady flows. OTV accurately measures unsteady flows with amplitudes as small as 3–6 $$\upmu$$ m s $$^{-1}$$ . We compare the accuracy of OTV and micro-PTV, and characterize the flow regime for which OTV outperforms micro-PTV. We also demonstrate the robustness of OTV by measuring the unsteady flow created by the cilia of green alga Chlamydomonas reinhardtii, and comparing with numerical predictions based on Stokes equations. An open-source implementation of the OTV software in Matlab is available through the 4TU.Centre for Research Data. Graphic- 28 August 2020
- Published by Springer Nature in Experiments in Fluids
- Vol. 61 (9) , 1-15
Open AccessOptical tweezers-based velocimetry: a method to measure microscale unsteady flows
In the study of micro-scale biological flows, velocimetry methods based on passive tracers, such as micro-PIV and micro-PTV, are well established to characterize steady flows. However, these methods become inappropriate for measuring unsteady flows of small amplitude, because, on these scales, the motion of passive tracers cannot be distinguished from Brownian motion. In this study, we use optical tweezers (OTs) in combination with Kalman filtering, to measure unsteady microscopic flows with high temporal accuracy. This method is referred to as optical tweezers-based velocimetry (OTV). The OTV method measures the nanometric displacements of a trapped bead, and predicts the instantaneous velocity of the flow by employing a Kalman filter. We discuss the accuracy of OTV in measuring unsteady flows with 1.5–70 $$\upmu$$ m s $$^{-1}$$ amplitudes and 10–90 Hz frequencies. We quantify how the bead size and the laser power affect the velocimetry accuracy, and specify the optimal choices for the bead size and laser power to measure different unsteady flows. OTV accurately measures unsteady flows with amplitudes as small as 3–6 $$\upmu$$ m s $$^{-1}$$ . We compare the accuracy of OTV and micro-PTV, and characterize the flow regime for which OTV outperforms micro-PTV. We also demonstrate the robustness of OTV by measuring the unsteady flow created by the cilia of green alga Chlamydomonas reinhardtii, and comparing with numerical predictions based on Stokes equations. An open-source implementation of the OTV software in Matlab is available through the 4TU.Centre for Research Data. Graphic