Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Keren Zhu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling

    by Evgenii Kim, Mohammad Daneshzand, Keren Zhu, Danyal Fareed Bhutto, Teresa Jacobson Kimberley, Dylan Edwards, Netri Pajankar, Parker Kotlarz, Tommi Raij, Sergey N. Makaroff, et al.

    Quantitative measures for Transcranial Magnetic Stimulation (TMS) intensity are needed to ensure safe and consistent application in therapeutic and research settings. However, resting motor thresholds (rMTs), commonly used to determine stimulation intensity, depend on the coil used. Unless motor mapping and treatment coils are identical, re‐thresholding is necessary, increasing patient discomfort and potentially introducing variability across studies. These considerations raise an unresolved fundamental question: does individual rMT reflect a consistent cortical electric field (E‐field) magnitude independent of coil geometry? We tested the hypothesis that rMT corresponds to a coil‐invariant cortical E‐field magnitude and evaluated a computational method for predicting stimulator output across different coils using a reference rMT. Thirteen healthy, right‐handed participants were recruited; ten were included in the primary analysis. Participants underwent TMS with two figure‐of‐eight coils of different sizes. E‐field distributions were simulated using a fast multipole boundary element method, in free space and within personalized MRI‐based head models. rMT prediction accuracy was compared between a detailed five‐layer and a simplified three‐layer head model, and both were evaluated against direct rMT scaling using the reference coil. The personalized E‐field‐based approach significantly improved rMT prediction accuracy over direct scaling ( p < 0.001). The root‐mean‐square error (RMSE) was 1.26% and 1.32% of maximum stimulator output (MSO) for detailed and simplified models, versus 6.1% MSO for direct scaling. Individual rMT corresponds to a constant cortical E‐field magnitude ratio across coil types. E‐field‐based prediction offers a more accurate, coil‐independent method for standardizing TMS intensity, reducing the need for repeated thresholding.


  • Open Access

    Real-Time Magnetocardiography with Passive Miniaturized Coil Array in Earth Ambient Field

    by Keren Zhu, Asimina Kiourti

    We demonstrate a magnetocardiography (MCG) sensor that operates in non-shielded environments, in real-time, and without the need for an accompanying device to identify the cardiac cycles for averaging. We further validate the sensor’s performance on human subjects. Our approach integrates seven (7) coils, previously optimized for maximum sensitivity, into a coil array. Based on Faraday’s law, magnetic flux from the heart is translated into voltage across the coils. By leveraging digital signal processing (DSP), namely, bandpass filtering and averaging across coils, MCG can be retrieved in real-time. Our coil array can monitor real-time human MCG with clear QRS complexes in non-shielded environments. Intra- and inter-subject variability tests confirm repeatability and accuracy comparable to gold-standard electrocardiography (ECG), viz., a cardiac cycle detection accuracy of >99.13% and averaged R-R interval accuracy of <5.8 ms. Our results confirm the feasibility of real-time R-peak detection using the MCG sensor, as well as the ability to retrieve the full MCG spectrum as based upon the averaging of cycles identified via the MCG sensor itself. This work provides new insights into the development of accessible, miniaturized, safe, and low-cost MCG tools.


  • Open Access

    Quantifying Cognitive Workload Using a Non-Contact Magnetocardiography (MCG) Wearable Sensor

    by Zitong Wang, Keren Zhu, Archana Kaur, Robyn Recker, Jingzhen Yang, Asimina Kiourti

    Quantifying cognitive workload, i.e., the level of mental effort put forth by an individual in response to a cognitive task, is relevant for healthcare, training and gaming applications. However, there is currently no technology available that can readily and reliably quantify the cognitive workload of an individual in a real-world environment at a seamless way and affordable price. In this work, we overcome these limitations and demonstrate the feasibility of a magnetocardiography (MCG) sensor to reliably classify high vs. low cognitive workload while being non-contact, fully passive and low-cost, with the potential to have a wearable form factor. The operating principle relies on measuring the naturally emanated magnetic fields from the heart and subsequently analyzing the heart rate variability (HRV) matrix in three time-domain parameters: standard deviation of RR intervals (SDRR); root mean square of successive differences between heartbeats (RMSSD); and mean values of adjacent R-peaks in the cardiac signals (MeanRR). A total of 13 participants were recruited, two of whom were excluded due to low signal quality. The results show that SDRR and RMSSD achieve a 100% success rate in classifying high vs. low cognitive workload, while MeanRR achieves a 91% success rate. Tests for the same individual yield an intra-subject classification accuracy of 100% for all three HRV parameters. Future studies should leverage machine learning and advanced digital signal processing to achieve automated classification of cognitive workload and reliable operation in a natural environment.


  • Detection of Extremely Weak and Wideband Bio-Magnetic Signals in Non-Shielded Environments Using Passive Coil Sensors

    by Keren Zhu, Asimina Kiourti

    We report a coil-based passive sensing system and associated Digital Signal Processing (DSP) capable of detecting extremely weak and wideband bio-magnetic signals without the need for shielding. Our previous work showed potential in this direction but was limited to detecting magnetocardiography (MCG) signals that are the strongest emanated by the human body as well as narrowband. In a major step forward, we advance our DSP with notch and Empirical Mode Decomposition filters, in addition to bandpass filtering and averaging utilized in the past and refine our coil design. We characterize the system's noise performance, analyze effectiveness of the DSP methods, and validate performance in vitro . The proposed system considerably outperforms our previous design: noise levels at 10 Hz and 100 Hz are reduced by ∼46% and ∼92%, respectively, while detection sensitivity is improved by ∼94% across a ∼3333% wider signal bandwidth. That is, signals as low as magnetomyography (MMG) and evoked Compound Action Potentials (eCAP) and of frequency range comparable to magnetoneurography (MNG) can now be retrieved passively, in non-shielded environments. As a proof-of-concept, we utilize a single sensor and 24 minutes of recording; however, these parameters are scalable, as is the strength and frequency range of detectable bio-magnetic signals. To this end, we include discussions on how the hardware and DSP components can be parameterized and adjusted to fit diverse clinical needs. The proposed system can empower seamless detection of MCG, MMG, eCAP, and MNG, among others, opening unexplored opportunities for the future of medical diagnostics, monitoring, and treatment.


  • Open Access

    A Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses

    by Keren Zhu, Asimina Kiourti

    It has long been common practice to capture the electric fields emanated by the human body as a means of detecting and/or monitoring diverse health conditions. However, these electric fields are strongly impacted by the complex permittivity of biological tissues which deteriorates their waveforms and limits their diagnostic capabilities. As an alternative, recent progress has been made in the measurement of bio-magnetic fields occur from the natural currents flowing through the body. The advantage in this case is, since tissues are non-magnetic, magnetic fields propagate in an uninterrupted manner towards the skin surface where they are eventually collected. This unveils game-changing opportunities for future medical diagnostics. Nevertheless, a major challenge associated with sensing these naturally emanated magnetic fields is that they are extremely weak, and in fact orders of magnitude smaller than those generated by the Earth. To this end, extensive efforts have been pursued to realize sensing technology that is sensitive enough to collect bio-magnetic fields. Example fields of use include magnetomyography (MMG), magnetocardiography (MCG), magnetoencephalography (MEG), and Magnetoneurography (MNG) (including magnetospinography (MSG)). This review will provide an overview of technologies used to sense bio-magnetic fields, list their merits and limits in a critical manner, and discuss clinical applications.


  • Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments

    by Keren Zhu, Adhvait M. Shah, Jan Berkow, Asimina Kiourti

    Existing practices for monitoring heart activity rely heavily on electrocardiography (ECG) approaches, which suffer from low accuracy (as electric fields get impacted by biological tissues); extensive diagnostic times; and lack of comfort (as electrodes are in direct contact with the human body). Though magnetocardiography (MCG) provides more accurate and localized signals while also being non-contact, state-of-the-art equipment for capturing such weak magnetic fields (i.e., SQUIDs) requires extensive shielding and is very expensive. MCG sensing devices that do not require shielding have been reported, but they are bulky, heavy, and cumbersome to use. In this work, we take a major step forward and propose a novel, miniature, and low-cost MCG sensor for operation in non-shielded environments that breaks the state-of-the-art boundaries in terms of size and weight. Our sensor relies on novel coil design principles and Digital Signal Processing (DSP) algorithms to achieve: (a) 4.67 times smaller diameter, (b) 4.5 times smaller height, and (c) at least 216 times lighter weight than previous passive implementations. In vitro measurements demonstrate that a 4-coil sensor array with 15 minutes of recording time is sufficient to capture human MCG signals. Discussions indicate that higher number of coils and longer recording times can be employed to improve the signal clarity and fit diverse clinical needs. The proposed coil sensor array provides a convenient method to diagnose several cardiac conditions, such as myocardial ischemia, arrhythmia, right atrial hypertrophy, right ventricular hypertrophy, and the Brugada syndrome