Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling
Open Access
- 30 May 2026
- journal article
- Published by Wiley in Human Brain Mapping
- Vol. 47 (8) , e70550
Abstract
Quantitative measures for Transcranial Magnetic Stimulation (TMS) intensity are needed to ensure safe and consistent application in therapeutic and research settings. However, resting motor thresholds (rMTs), commonly used to determine stimulation intensity, depend on the coil used. Unless motor mapping and treatment coils are identical, re‐thresholding is necessary, increasing patient discomfort and potentially introducing variability across studies. These considerations raise an unresolved fundamental question: does individual rMT reflect a consistent cortical electric field (E‐field) magnitude independent of coil geometry? We tested the hypothesis that rMT corresponds to a coil‐invariant cortical E‐field magnitude and evaluated a computational method for predicting stimulator output across different coils using a reference rMT. Thirteen healthy, right‐handed participants were recruited; ten were included in the primary analysis. Participants underwent TMS with two figure‐of‐eight coils of different sizes. E‐field distributions were simulated using a fast multipole boundary element method, in free space and within personalized MRI‐based head models. rMT prediction accuracy was compared between a detailed five‐layer and a simplified three‐layer head model, and both were evaluated against direct rMT scaling using the reference coil. The personalized E‐field‐based approach significantly improved rMT prediction accuracy over direct scaling ( p < 0.001). The root‐mean‐square error (RMSE) was 1.26% and 1.32% of maximum stimulator output (MSO) for detailed and simplified models, versus 6.1% MSO for direct scaling. Individual rMT corresponds to a constant cortical E‐field magnitude ratio across coil types. E‐field‐based prediction offers a more accurate, coil‐independent method for standardizing TMS intensity, reducing the need for repeated thresholding.Keywords
Funding Information
- National Institutes of Health (R01MH128421)
- National Institutes of Health (R01DC020891)
- National Institutes of Health (P41EB030006)
- National Institutes of Health (S10OD028668)
- National Institutes of Health (K01MH138823)
- National Institutes of Health (R01MH130490)
- National Institutes of Health (R01EB035484)
- National Institutes of Health (K24DC018603)
- National Institutes of Health (R01NS126337)
This publication has 50 references indexed in Scilit:
- Electric Field Modeling in Personalizing Transcranial Magnetic Stimulation InterventionsBiological Psychiatry, 2023
- Transcranial Magnetic Stimulation Treatment for Smoking Cessation: An Introduction for Primary Care CliniciansThe American Journal of Medicine, 2021
- Conditions for numerically accurate TMS electric field simulationBrain Stimulation, 2020
- SimNIBS 2.1: A Comprehensive Pipeline for Individualized Electric Field Modelling for Transcranial Brain Stimulation2019
- The effect of stimulation type, head modeling, and combined EEG and MEG on the source reconstruction of the somatosensory P20/N20 componentHuman Brain Mapping, 2019
- Effects of pulse width, waveform and current direction in the cortex: A combined cTMS-EEG studyBrain Stimulation, 2018
- Where and what TMS activates: Experiments and modelingBrain Stimulation, 2018
- Electric field depth–focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designsBrain Stimulation, 2013
- Role of cortical cell type and morphology in subthreshold and suprathreshold uniform electric field stimulation in vitroBrain Stimulation, 2009
- Finding the depth of magnetic brain stimulation: a re-evaluationElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1994