Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahmed Hamza Hossieny Ali has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of the Effects of Design and Operating Parameters on the Thermal Management System Performance of a Lithium-Ion Battery Pack for Sustainable Energy Storage

    by Ahmed Hamza H. Ali, Mohamed Hassan Soliman Mohamed, Ibrahim M. Ismail

    The aim of this study is to advance sustainable transportation, energy efficiency, environmental benefits, and the long-term performance of electric vehicles and to support the transition to sustainable transport while mitigating environmental impacts. Lithium-ion battery packs are widely used in electric vehicles and as energy storage systems because of their long lifespan and high energy density. This study experimentally and numerically investigated the effect of a hybrid sensible-cooling and phase-change material (PCM) approach to cooling a lithium-ion battery pack and its impact on battery thermal management system (BTMS) performance. The experimental approach involved designing, constructing, and operating the BTMS under both natural- and forced-air-convection cooling with and without PCM. A theoretical model was developed to investigate design and operating parameters, and its results were validated against experimental data. The main experimental findings show that under hybrid cooling, which combines either natural convection or forced-air cooling with PCM around the battery cells, the battery cell temperatures were 47.2 °C and 42.7 °C at the end of discharge, which are considered safe. The model results were validated against the corresponding measured values, and they agreed with them. The results indicate that the cells remain at safe temperatures across different PCM masses and that BTMS shows the best thermal performance with a PCM thickness of dPCM = 10 mm with a balanced configuration under the evaluated constraints. Also, the air–PCM hybrid systems offer a lighter, more cost-effective alternative with lower parasitic power that still meets standard safety and temperature limits (<60 °C) and requires simpler maintenance.

  • Design and performance of hybrid thermal energy storage integrated within a solar‐powered vapor absorption cooling system for milk chilling

    by Dinesh Kumar Sharma, Dilip Sharma, Manu Augustine, Vishnu Agrawal, Ahmed Hamza H. Ali

    Solar‐powered sorption cooling systems inevitably require optimized thermal energy storage to achieve consistent performance and economic viability, thereby ensuring sustainability. This study presents the design, performance, productivity, cost performance, and environmental impact of a 400 MJ hybrid sensible and latent thermal energy storage (comprising Xylitol as a phase change material and soft water as a heat transfer fluid) when integrated within a system that has a 17.5 kW single‐effect LiBr‐H 2 O vapor absorption driven by a hot water outlet from an 81 m 2 solar collector field used for cooling 1000 L of milk per day. The dynamic modeling of the entire system as a function of time is performed, along with the integration of a hybrid thermal energy storage system, using fundamental and empirical relations. Furthermore, a year‐round analysis is conducted to estimate the amount of cold energy produced and the overall system performance. The results clearly show that the system can produce up to 28,360 kWh of cold energy annually, thereby reducing annual CO 2 emissions by 2.98 tonnes in the Indian context. The economics of cooling produced with this system have been improved investigated with carbon credit‐linked incentives, which resulted in the simple and discounted payback periods of 8.9 and 12.23 years, respectively. The levelized cost of cooling of 0.103 $/kWhc has been achieved for the system, with an internal rate of return of 15.4%.

  • Open Access

    Transient behavior of thermally developing laminar flow within offset plates confined in a channel heated by radiation for integrated photovoltaic solar thermal collector applications

    by Ahmed Hamza H. Ali, Jillan Ahmed Hamza H. Ali

    Experimental and numerical investigations were conducted on the transient behavior, following power activation, of laminar flow forced-convection heat transfer for air traversing offset plates within a two-parallel-plate channel heated by radiation, which is pertinent to integrated photovoltaic/thermal air heater solar collector applications. In the numerical simulation, a two-dimensional transient model was used, and the temperature boundary conditions were determined at each time step. The experimental data showed a range of 990 to 4050 seconds for the time to reach equilibrium, depending on Re. It also revealed that the heat-transfer mechanism undergoes dynamic changes, characterized by a minimum in the convective heat-transfer coefficient, before stabilizing at a steady state, a critical factor in understanding the system's heat-transfer efficiency. Experimental and numerical findings indicated that offset plates attain steady-state temperatures that depend on plate location, ranging from 40°C to 100°C, with equilibrium times varying from 4050 seconds at Re=650 to 990 seconds at Re=2550. The transient Nusselt number initially peaks during the transition period, then stabilizes between 5 and 15 seconds, indicating that the heat-transfer mechanism undergoes dynamic changes that stabilize more quickly at higher Reynolds numbers. The model's velocity field and isothermal contour maps provide a physical explanation of the experimental results.

  • Open Access

    Solar Driven Refrigeration Systems in Food Supply Cold Chain: The State-of-the-Art, Challenges, and Environmental Impact

    by Ahmed Hamza H. Ali, Jillan Ahmed Hamza H. Ali

    A considerable proportion of perishable goods, including fruits and vegetables, deteriorate prior to reaching customers. Inadequate refrigeration infrastructure, particularly in developing nations with arid climates and markets distant from agricultural sources, accounts for most of these losses. A food cold chain has three primary phases: pre-cooling, cold storage, and refrigerated transportation. All phases of the cold chain rely fundamentally on refrigeration to preserve perishable products at designated temperatures, relative humidity, and CO2 concentrations, thus prolonging their shelf life. Solar-driven or aided refrigeration systems use solar energy to power cooling systems and preserve the food in the cold chain. These systems are especially beneficial in off-grid or developing areas for preserving perishable goods such as fruits, vegetables, and other food items, mitigating postharvest losses that can exceed 30–50% in areas with inconsistent energy supplies. Despite progress in efficiency and scalability, numerous research gaps remain across technological, economic, social, policy, and regional dimensions, including technical aspects, optimization, and integration. There is a need to enhance energy-efficient designs, particularly by managing solar intermittency to address non-uniform cooling, which leads to inconsistent ripening and spoilage, and by integrating sustainable refrigerants to mitigate environmental impact. Further development is necessary for micro-scale, transportable, or decentralized systems designed for small farms, while economic and financing obstacles include high upfront costs and limited financial accessibility. Substantial deficiencies exist in creating affordable models and funding channels for small-scale agriculturalists. Addressing these deficiencies could expedite adoption, thereby reducing global food loss and waste (accounting for 8–10% of GHG emissions) while improving food security. Future research must emphasize multidisciplinary methodologies that amalgamate engineering, economics, and social sciences to provide comprehensive solutions.


  • Performance Analysis of Small-Scale HAWTs with Stepped Airfoil Modifications

    by Mohamed A. Aziz, Ahmed M. Elsayed, Osama A. Gaheen, Ahmed Hamza H. Ali, Ahmed Farag, Mohamed B. Farghaly


  • Comparative Investigation of the Energy Efficiency of Mini-Split Air Conditioning with Variable Refrigerant Flow Systems for Office Buildings in Hot Climate.

    by Ahmed Hussien, Ahmed Hamza H. Ali, Ibrahim M. Ismail

    Egypt is confronted with a critical issue of increasing electricity consumption, mainly attributable to the extensive usage of air conditioning equipment, especially in areas with high temperatures and dry circumstances such as Aswan city. This study addresses a comparative analysis of the energy saving of two air conditioning systems: a Mini-Split unit and a variable refrigerant flow system (VRF)for office Buildings located in Aswan City. The main goal is to examine their energy efficiency and suitability for addressing issues related to power usage. The main conclusions are clear-cut. The VRF system constantly shows a noticeable advantage in terms of energy efficiency, especially in the summer when it's hot outside. Its consistent year-round balanced energy performance highlights its flexibility in changing environmental conditions. A significant annual energy savings of about 19,187.43 kWh can be achieved by switching to the VRF system. The VRF system's estimated energy efficiency ratio to the MSAV system is roughly 0.746. This ratio highlights how energy-efficient the VRF is—it uses about 74.6% less energy for comparable or even better HVAC performance. Study backs energy-efficient HVAC for sustainable buildings, offering crucial insights to decision-makers. There is no doubt about the potential benefits of converting to the VRF system, especially in areas with various climates. These results contribute to the conversation about green HVAC systems and provide building managers and policymakers with valuable information to improve energy efficiency and reduce environmental impact. This research is a priceless tool for deciding on energy-efficient and environmentally friendly HVAC systems.


  • Experimental Study on Performance of a Solar Thermal-Driven Vapor Absorption System Integrated With Hot Thermal Energy Storage for Milk Chilling

    by Dinesh Kumar Sharma, Dilip Sharma, Ahmed Hamza H. Ali

    Solar thermal-driven vapor absorption system has proven to be a feasible and viable cooling source. However, most reported installations for milk chilling applications are equipped with an auxiliary heater that consumes significant electricity/gas, making it economically unviable. In this study, the experimental investigation of the performance of a solar-powered vapor absorption chiller has been reported for milk chilling applications as per standard ISO 5708–2 II. It has been identified that the performance of the vapor absorption chiller is quite uncertain and underperforming while operated with the heat directly fed through the evacuated tube compound parabolic concentrator solar field due to diurnal and seasonal variations of solar radiation intensity. Therefore, hot thermal energy storage integration has been studied and analyzed in this study. The performance of the vapor absorption chiller has improved significantly with the use of hot thermal energy storage in the solar circuit as the coefficient of performance (COP) of the vapor absorption chiller improved up to 0.4, which was earlier around 0.25. Further, hot thermal energy storage provides better thermal management to increase the productivity and performance of the vapor absorption chiller, and the cooling time for the first milking is 2 h and 45 min. The performance of the vapor absorption chiller enhanced further up to 0.52 when supplied heat entirely with thermal energy storage. The energy efficiency ratio has a maximum value of 6.1, with an average of 4.3, whereas the thermal COP has an average of 0.35 and a maximum value of 0.52 when run with thermal energy storage alone.


  • Numerical Investigation on the Effect of the Azimuthal Deviation on Performance of Equal Speed Co-Rotating Double Rotor Small-Scale Horizontal-Axis Wind Turbine

    by Ahmed Abdelfattah Abdelwahed Morsi, Mohamed Fekry Farah El-Dosoky, Othman Hassan Othman, Mohamed Mahmoud Sayed Ahmed, Ahmed Hamza Hossieny Ali

    A double-rotor setup is a promising approach to increase wind turbine power extraction. One common double-rotor configuration is the co-rotating-equal-speed arrangement. The performance of this setup is affected by the azimuthal deviation between the two rotors, which remains constant during rotation. To identify the impact of azimuthal deviation, a numerical investigation was conducted using 10 m/s input wind speed and 0.9 m turbine diameter. The separation distance between the two rotors varied for two values of 0.14 and 0.25 rotor-diameter. The power coefficient of both rotors and the overall turbine were analyzed at different azimuthal deviations using Reynolds-averaged Navier–Stokes k-ω SST equations. The azimuthal deviation was positive when the front rotor preceded the rear and negative when the rear preceded the front. At 0.14 rotor-diameter separation, positive deviation increased the front rotor power coefficient but decreased the rear’s, while negative deviation had the opposite effect on both rotors. The maximum changes in the power coefficient of the front and rear rotors at tip speed ratio of 5 were ΔC_P=0.058 and ΔC_P=0.066, respectively. However, the net harvesting power by the double-rotor wind turbine exhibited slight marginal change of ΔC_P=0.008 at a tip speed ratio of 5. In contrast, at the greater separation, the power coefficients of both rotors and the overall turbine showed slight change with the variation of the azimuthal deviation with a marginal change of ΔC_P=0.012 at a tip speed ratio of 5. Moreover, the highest increase in the power coefficient was 15% compared to single rotor.