Jillian R. Tate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jillian R. Tate has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Mauro Panteghini
Department of Laboratory Medicine , Nicolaus Copernicus University, Collegium Medicum , Bydgoszcz , Poland
2 shared publications Peter Mollee
Haematology Department, Princess Alexandra Hospital, Brisbane, QLD, Australia
2 shared publications- Peter Mollee
Princess Alexandra Hospital and University of Queensland
2 shared publications Tina Yen
Department of Chemical Pathology, The Royal Children's Hospital, Parkville, VIC, Australia
2 shared publicationsAlexey Katrukha
Research Department, HyTest Ltd, Turku, Finland
1 shared publicationCarmel Hawley
Department of Renal Medicine, Princess Alexandra Hospital, Brisbane, QLD, Australia
1 shared publication
Latest Publications
- 30 November 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (2) , e3-e4
Response to Letter to the Editor about immunochemical measurement of urine free light chains
Article Response to Letter to the Editor about immunochemical measurement of urine free light chains was published on February 1, 2019 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 57, issue 2).
- 30 November 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (2) , e3-e4
Response to Letter to the Editor about immunochemical measurement of urine free light chains
Article Response to Letter to the Editor about immunochemical measurement of urine free light chains was published on February 1, 2019 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 57, issue 2).
- 29 September 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (2) , e1-e2
Response to article by Caponi et al. about serum free light chains
Article Response to article by Caponi et al. about serum free light chains was published on February 1, 2019 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 57, issue 2).
- 29 September 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (2) , e1-e2
Response to article by Caponi et al. about serum free light chains
Article Response to article by Caponi et al. about serum free light chains was published on February 1, 2019 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 57, issue 2).
- 1 January 2018
- Published by Elsevier in Clinical Biochemistry
- Vol. 51, 4-9
A global call to arms for clinical laboratories – Harmonised quantification and reporting of monoclonal proteins
- 1 January 2018
- Published by Elsevier in Clinical Biochemistry
- Vol. 51, 4-9
A global call to arms for clinical laboratories – Harmonised quantification and reporting of monoclonal proteins
- 1 January 2016
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 54 (8) , 1277-1279
Measurement uncertainty – a revised understanding of its calculation and use
Article Measurement uncertainty – a revised understanding of its calculation and use was published on August 1, 2016 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 54, issue 8).
- 1 January 2016
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 54 (8) , 1277-1279
Measurement uncertainty – a revised understanding of its calculation and use
Article Measurement uncertainty – a revised understanding of its calculation and use was published on August 1, 2016 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 54, issue 8).
- 1 January 2016
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 54 (6) , 899-905
Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
Article Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies was published on June 1, 2016 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 54, issue 6).
- 1 January 2016
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 54 (6) , 899-905
Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
Article Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies was published on June 1, 2016 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 54, issue 6).
- 1 August 2015
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 61 (8) , 1012-1015
Transference and Validation of Reference Intervals
- 1 August 2015
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 61 (8) , 1012-1015
Transference and Validation of Reference Intervals
- 1 January 2015
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 53 (5) , 677-690
Evaluation of standardization capability of current cardiac troponin I assays by a correlation study: results of an IFCC pilot project
Background: As a part of an International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) project to prepare a commutable reference material for cardiac troponin I (cTnI), a pilot study evaluated current cTnI assays for measurement equivalence and their standardization capability. Methods: cTnI-positive samples collected from 90 patients with suspected acute myocardial infarction were assessed for method comparison by 16 cTnI commercial assays according to predefined testing protocols. Seven serum pools prepared from these samples were also assessed. Results: Each assay was assessed against median cTnI concentrations measured by 16 cTnI assays using Passing-Bablok regression analysis of 79 patient samples with values above each assay’s declared detection limit. We observed a 10-fold difference in cTnI concentrations for lowest to highest measurement results. After mathematical recalibration of assays, the between-assay variation for patient samples reduced on average from 40% to 22% at low cTnI concentration, 37%–20% at medium concentration, and 29%–14% at high concentration. The average reduction for pools was larger at 16%, 13% and 7% for low, medium and high cTnI concentrations, respectively. Overall, assays demonstrated negligible bias after recalibration (y-intercept: –1.4 to 0.3 ng/L); however, a few samples showed substantial positive and/or negative differences for individual cTnI assays. Conclusions: All of the 16 commercial cTnI assays evaluated in the study demonstrated a significantly higher degree of measurement equivalence after mathematical recalibration, indicating that measurement harmonization or standardization would be effective at reducing inter-assay bias. Pooled sera behaved similarly to individual samples in most assays.
- 1 January 2015
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 53 (5) , 677-690
Evaluation of standardization capability of current cardiac troponin I assays by a correlation study: results of an IFCC pilot project
Background: As a part of an International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) project to prepare a commutable reference material for cardiac troponin I (cTnI), a pilot study evaluated current cTnI assays for measurement equivalence and their standardization capability. Methods: cTnI-positive samples collected from 90 patients with suspected acute myocardial infarction were assessed for method comparison by 16 cTnI commercial assays according to predefined testing protocols. Seven serum pools prepared from these samples were also assessed. Results: Each assay was assessed against median cTnI concentrations measured by 16 cTnI assays using Passing-Bablok regression analysis of 79 patient samples with values above each assay’s declared detection limit. We observed a 10-fold difference in cTnI concentrations for lowest to highest measurement results. After mathematical recalibration of assays, the between-assay variation for patient samples reduced on average from 40% to 22% at low cTnI concentration, 37%–20% at medium concentration, and 29%–14% at high concentration. The average reduction for pools was larger at 16%, 13% and 7% for low, medium and high cTnI concentrations, respectively. Overall, assays demonstrated negligible bias after recalibration (y-intercept: –1.4 to 0.3 ng/L); however, a few samples showed substantial positive and/or negative differences for individual cTnI assays. Conclusions: All of the 16 commercial cTnI assays evaluated in the study demonstrated a significantly higher degree of measurement equivalence after mathematical recalibration, indicating that measurement harmonization or standardization would be effective at reducing inter-assay bias. Pooled sera behaved similarly to individual samples in most assays.
- 1 November 2014
- Vol. 35 (4) , 213-35
Harmonising adult and paediatric reference intervals in australia and new zealand: an evidence-based approach for establishing a first panel of chemistry analytes.
Scientific evidence supports the use of common reference intervals (RIs) for many general chemistry analytes, in particular those with sound calibration and traceability in place. Already the Nordic countries and United Kingdom have largely achieved harmonised RIs. Following a series of workshops organised by the Australasian Association of Clinical Biochemists (AACB) between 2012 and 2014 at which an evidence-based approach for determination of common intervals was developed, pathology organisations in Australia and New Zealand have reached a scientific consensus on what adult and paediatric intervals we should use across Australasia. The aim of this report is to describe the processes that the AACB and the Royal College of Pathologists of Australasia have taken towards recommending the implementation of a first panel of common RIs for use in Australasia.
- 1 November 2014
- Vol. 35 (4) , 213-35
Harmonising adult and paediatric reference intervals in australia and new zealand: an evidence-based approach for establishing a first panel of chemistry analytes.
Scientific evidence supports the use of common reference intervals (RIs) for many general chemistry analytes, in particular those with sound calibration and traceability in place. Already the Nordic countries and United Kingdom have largely achieved harmonised RIs. Following a series of workshops organised by the Australasian Association of Clinical Biochemists (AACB) between 2012 and 2014 at which an evidence-based approach for determination of common intervals was developed, pathology organisations in Australia and New Zealand have reached a scientific consensus on what adult and paediatric intervals we should use across Australasia. The aim of this report is to describe the processes that the AACB and the Royal College of Pathologists of Australasia have taken towards recommending the implementation of a first panel of common RIs for use in Australasia.
- 1 May 2014
- Published by Elsevier in Clinica Chimica Acta
- Vol. 432, 1-3
“Harmonization of laboratory testing — A global activity”
- 1 May 2014
- Published by Elsevier in Clinica Chimica Acta
- Vol. 432, 1-3
“Harmonization of laboratory testing — A global activity”