Benedikt Schlecker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benedikt Schlecker has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jens Anders
University of Stuttgart
2 shared publications - Klaus Lips
Helmholtz-Zentrum Berlin für Materialien und Energie GmbH , Hahn-Meitner Platz 1
2 shared publications - Alexander Angerhofer
Department of Chemistry, University of Florida, Gainesville, Florida 32611, United States
1 shared publication Alexander Hoffmann
University of Ulm, Institute of Microelectronics, Ulm, Germany
1 shared publicationAnh Chu
University of Stuttgart, Institute of Smart Sensors, Stuttgart, Germany
1 shared publication- Anh Chu
Institute of Smart Sensors, Universität Stuttgart, 70569 Stuttgart, Germany
1 shared publication
Latest Publications
- Open Access
- 23 June 2021
- Published by Copernicus GmbH
- p. 1-19
Comment on mr-2021-42
In this paper, we present an in-depth analysis of a voltage-controlled oscillator (VCO) based sensing method for electron spin resonance (ESR) spectroscopy, which greatly simplifies the experimental setup compared to conventional detection schemes. In contrast to our previous oscillator-based ESR detectors, where the ESR signal was encoded in the oscillation frequency, in the amplitude-sensitive method, the ESR signal is sensed as a change of the oscillation amplitude of the VCO. Therefore, using a VCO architecture with a built-in amplitude demodulation scheme, the experimental setup reduces to a single permanent magnet in combination with a few inexpensive electronic components. We present a theoretical analysis of the achievable limit of detection, which uses a perturbation theory based VCO-modeling for the signal and applies a stochastic averaging approach to obtain a closed-form expression for the noise floor. Additionally, the paper also introduces a numerical model suitable for simulating oscillator-based ESR experiments in a conventional circuit simulator environment. This model can, e.g., be used to optimize sensor performance early on in the design phase. Finally, all presented models are verified against measured results from a prototype VCO operating at 14 GHz inside a 0.5 T magnetic field.
- 23 June 2021
- Published by Copernicus GmbH
- p. 1-19
Open AccessComment on mr-2021-42
In this paper, we present an in-depth analysis of a voltage-controlled oscillator (VCO) based sensing method for electron spin resonance (ESR) spectroscopy, which greatly simplifies the experimental setup compared to conventional detection schemes. In contrast to our previous oscillator-based ESR detectors, where the ESR signal was encoded in the oscillation frequency, in the amplitude-sensitive method, the ESR signal is sensed as a change of the oscillation amplitude of the VCO. Therefore, using a VCO architecture with a built-in amplitude demodulation scheme, the experimental setup reduces to a single permanent magnet in combination with a few inexpensive electronic components. We present a theoretical analysis of the achievable limit of detection, which uses a perturbation theory based VCO-modeling for the signal and applies a stochastic averaging approach to obtain a closed-form expression for the noise floor. Additionally, the paper also introduces a numerical model suitable for simulating oscillator-based ESR experiments in a conventional circuit simulator environment. This model can, e.g., be used to optimize sensor performance early on in the design phase. Finally, all presented models are verified against measured results from a prototype VCO operating at 14 GHz inside a 0.5 T magnetic field.
- 12 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (20) , 8995-9003
Towards Low-Cost, High-Sensitivity Point-of-Care Diagnostics Using VCO-Based ESR-on-a-Chip Detectors
In this paper, we present a new architecture for VCO-based ESR detection for a future use in portable, point-ofcare ESR spectrometers. The proposed architecture is centered around an ASIC containing a VCO-based ESR detector with two distinct tuning ports with largely different VCO gains to enable wide frequency sweeps and small-signal frequency modulations while keeping the requirements on the digital-to-analog converter driving the ports manageable. Additionally, the proposed ASIC features a second VCO for an on-chip frequency downconversion via mixing. To allow for a precise derivation of the operating frequency from an external reference as it is required for quantitative ESR experiments, the two on-chip VCOs are embedded into an offset phase-locked loop. The proposed architecture is verified with ESR experiments on commonly used ESR standard samples (DPPH and BDPA). In these experiments, a spin sensitivity of 1.7 × 109 spins=(G √Hz) has been achieved at B0 = 450mT, which is comparable to the state of the art, using a permanent magnet and low-cost signal processing on an FPGA. The presented proof-of-concept experiments clearly demonstrate the potential of the proposed VCO-based ESR detection system for future point-of-care applications.
- 12 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (20) , 8995-9003
Towards Low-Cost, High-Sensitivity Point-of-Care Diagnostics Using VCO-Based ESR-on-a-Chip Detectors
In this paper, we present a new architecture for VCO-based ESR detection for a future use in portable, point-ofcare ESR spectrometers. The proposed architecture is centered around an ASIC containing a VCO-based ESR detector with two distinct tuning ports with largely different VCO gains to enable wide frequency sweeps and small-signal frequency modulations while keeping the requirements on the digital-to-analog converter driving the ports manageable. Additionally, the proposed ASIC features a second VCO for an on-chip frequency downconversion via mixing. To allow for a precise derivation of the operating frequency from an external reference as it is required for quantitative ESR experiments, the two on-chip VCOs are embedded into an offset phase-locked loop. The proposed architecture is verified with ESR experiments on commonly used ESR standard samples (DPPH and BDPA). In these experiments, a spin sensitivity of 1.7 × 109 spins=(G √Hz) has been achieved at B0 = 450mT, which is comparable to the state of the art, using a permanent magnet and low-cost signal processing on an FPGA. The presented proof-of-concept experiments clearly demonstrate the potential of the proposed VCO-based ESR detection system for future point-of-care applications.