Meinhard Schilling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Meinhard Schilling has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Hampel
National Institute of Standards and Technology 1 , Boulder, Colorado 80305
17 shared publications - Paul Julius Ritter
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
13 shared publications - Max Pröpper
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
11 shared publications - Marius Neumann
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
7 shared publications - Dominik Hanisch
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
6 shared publications - Frank Ludwig
Institut für Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig, Germany
6 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Yotta Counter for wide-range electrical current measurement
Measuring electrical current across a wide dynamic range without switching ranges remains a significant instrumentation challenge. Existing instruments based on conventional approaches, such as resistive current-to-voltage conversion, require range switching, which introduces heterogeneous measurement uncertainty and calibration dependencies. Here, we present a scalable, flexible, portable, and room-temperature instrument based on parallel current-to-frequency conversion and digital pulse counting, in which the measurement is inherently traceable to the SI unit of time. By distributing the input signal across 1080 independent, homogeneous counting channels, the architecture supports a total counting bandwidth from 5 μHz to beyond 216 GHz. The dynamic range spanning ∼4×1016 in frequency is further extendable by deploying additional parallel channels or increasing the clock frequency. By integrating the multichannel digital frequency counter with a current-to-frequency converter, the device demonstrates current measurements over a dynamic range on the order of 108, from 68 pA to 4 mA without range switching. The parallel-channel architecture ensures linearity across this wide dynamic range by additively summing homogeneous channel outputs, without introducing range-dependent discontinuities or heterogeneous uncertainty. Performance is validated using a low-noise macroscopic current source. The architecture is conceptually aligned with the 2019 SI (International System of Units) redefinition of the ampere and is designed to be compatible with future advances in electrical current metrology in terms of scalability.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessYotta Counter for wide-range electrical current measurement
Measuring electrical current across a wide dynamic range without switching ranges remains a significant instrumentation challenge. Existing instruments based on conventional approaches, such as resistive current-to-voltage conversion, require range switching, which introduces heterogeneous measurement uncertainty and calibration dependencies. Here, we present a scalable, flexible, portable, and room-temperature instrument based on parallel current-to-frequency conversion and digital pulse counting, in which the measurement is inherently traceable to the SI unit of time. By distributing the input signal across 1080 independent, homogeneous counting channels, the architecture supports a total counting bandwidth from 5 μHz to beyond 216 GHz. The dynamic range spanning ∼4×1016 in frequency is further extendable by deploying additional parallel channels or increasing the clock frequency. By integrating the multichannel digital frequency counter with a current-to-frequency converter, the device demonstrates current measurements over a dynamic range on the order of 108, from 68 pA to 4 mA without range switching. The parallel-channel architecture ensures linearity across this wide dynamic range by additively summing homogeneous channel outputs, without introducing range-dependent discontinuities or heterogeneous uncertainty. Performance is validated using a low-noise macroscopic current source. The architecture is conceptually aligned with the 2019 SI (International System of Units) redefinition of the ampere and is designed to be compatible with future advances in electrical current metrology in terms of scalability.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (7) , 1500910
Design and Performance of a 10-GHz HTS He-FIB JJ Mixer on LSAT Substrate
This paper presents a compact, single-ended high-temperature superconducting (HTS) helium-focused ion beam (He-FIB) Josephson junction (JJ) mixer. The planar circuit is fabricated from a thin film layer of YBa2Cu3O7-x deposited on a 10 mm × 10 mm Lanthanum Strontium Aluminium Tantalate (LSAT) substrate. A comprehensive six-step microstrip design methodology is outlined, detailing the JJ's physical geometries, high frequency and DC grounding, impedance matching, and filtering networks. The complete microstrip topology is designed to achieve an approximate radio frequency (RF) input passband between 9.9 GHz to 10.6 GHz with high out-of-band isolation, a single local oscillator (LO) resonance at 11.54 GHz and an intermediate frequency (IF) lowpass cut-off at 2.3 GHz. The proposed RF impedance matching network is uniquely designed to mitigate the significant performance limitation associated with normal resistances ($\rm{R}_\rm{n}$) scatter observed in HTS JJs. By implementing the proposed design methodology, a stable percentage bandwidth and $\rm{S}_{11}$ $\leq$ -10 dB is maintained between ${\mathit{R}}_\rm{n} =$ 5 $\Omega$ to 10 $\Omega$, which coincides with the fabrication variance for He-FIB JJs. The HTS mixer is manufactured and its DC and high frequency behaviours are characterised at 6 K, 10 K, 20 K, 30 K, and 40 K. The measured ${\mathit{R}}_\rm{n}$ is 9.77 $\Omega$, which significantly deviated from the predicted value of 5 $\Omega$, emphasising the importance of the adaptability and versatility of the implemented impedance matching network. Exposed to the lowest measured temperature, the HTS mixer exhibited a maximum conversion gain of -4.93 dB which demonstrates the potential capabilities in He-FIB induced barrier JJs on LSAT substrates as frequency mixers.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (7) , 1500910
Design and Performance of a 10-GHz HTS He-FIB JJ Mixer on LSAT Substrate
This paper presents a compact, single-ended high-temperature superconducting (HTS) helium-focused ion beam (He-FIB) Josephson junction (JJ) mixer. The planar circuit is fabricated from a thin film layer of YBa2Cu3O7-x deposited on a 10 mm × 10 mm Lanthanum Strontium Aluminium Tantalate (LSAT) substrate. A comprehensive six-step microstrip design methodology is outlined, detailing the JJ's physical geometries, high frequency and DC grounding, impedance matching, and filtering networks. The complete microstrip topology is designed to achieve an approximate radio frequency (RF) input passband between 9.9 GHz to 10.6 GHz with high out-of-band isolation, a single local oscillator (LO) resonance at 11.54 GHz and an intermediate frequency (IF) lowpass cut-off at 2.3 GHz. The proposed RF impedance matching network is uniquely designed to mitigate the significant performance limitation associated with normal resistances ($\rm{R}_\rm{n}$) scatter observed in HTS JJs. By implementing the proposed design methodology, a stable percentage bandwidth and $\rm{S}_{11}$ $\leq$ -10 dB is maintained between ${\mathit{R}}_\rm{n} =$ 5 $\Omega$ to 10 $\Omega$, which coincides with the fabrication variance for He-FIB JJs. The HTS mixer is manufactured and its DC and high frequency behaviours are characterised at 6 K, 10 K, 20 K, 30 K, and 40 K. The measured ${\mathit{R}}_\rm{n}$ is 9.77 $\Omega$, which significantly deviated from the predicted value of 5 $\Omega$, emphasising the importance of the adaptability and versatility of the implemented impedance matching network. Exposed to the lowest measured temperature, the HTS mixer exhibited a maximum conversion gain of -4.93 dB which demonstrates the potential capabilities in He-FIB induced barrier JJs on LSAT substrates as frequency mixers.
- Open Access
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (5) , 528-532
A Cross-Voltage-Domain Instrumentation-Amplifier ESP Unit for Ion Shuttling at 5 K
This work presents a cross-voltage domain instrumentation amplifier (INA) based electrode signal processing (ESP) unit for providing full-scale (FS) voltage ranges in excess of 10V at the electrodes of a trapped-ion quantum computer (TIQC) at cryogenic temperatures (CT). It carries out a systematic comparison between a reference design and the proposed INA approach. While both designs achieve their targeted specifications at room temperature (RT), the reference ESP unit’s linearity and noise performance deteriorates at CT. In contrast, the proposed INA-based ESP unit maintains its linearity and noise performance down to 5 K. Both designs are fabricated in a 130nm BCD technology and are evaluated under identical measurement conditions. Measurement results demonstrate that the proposed INA-based ESP unit greatly improves upon the reference design. At 5K its integrated RMS noise improves from 10.2 mVrms to 0.9 mVrms, while its SFDR improves by 25 dB to 49.9 dB and its power is reduced by about 11mW down to 19.5mW.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (5) , 528-532
Open AccessA Cross-Voltage-Domain Instrumentation-Amplifier ESP Unit for Ion Shuttling at 5 K
This work presents a cross-voltage domain instrumentation amplifier (INA) based electrode signal processing (ESP) unit for providing full-scale (FS) voltage ranges in excess of 10V at the electrodes of a trapped-ion quantum computer (TIQC) at cryogenic temperatures (CT). It carries out a systematic comparison between a reference design and the proposed INA approach. While both designs achieve their targeted specifications at room temperature (RT), the reference ESP unit’s linearity and noise performance deteriorates at CT. In contrast, the proposed INA-based ESP unit maintains its linearity and noise performance down to 5 K. Both designs are fabricated in a 130nm BCD technology and are evaluated under identical measurement conditions. Measurement results demonstrate that the proposed INA-based ESP unit greatly improves upon the reference design. At 5K its integrated RMS noise improves from 10.2 mVrms to 0.9 mVrms, while its SFDR improves by 25 dB to 49.9 dB and its power is reduced by about 11mW down to 19.5mW.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Narrowband Magnetic Particle Imaging Based on Multiharmonic System Matrix
Magnetic particle imaging (MPI) is an emerging medical imaging technique for quantitatively visualizing the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs), which has shown great potential in biomedicine. In this study, we propose an approach of narrowband MPI based on a multiharmonic system matrix. A high-frequency ( $f_{{0}} =101$ kHz) AC magnetic field in the $x$ -direction is used to excite SPIONs to generate spectra, while a low-frequency ( $f_{\text {y}} =33$ Hz) AC magnetic field in the $y$ -direction is used to scan the field-free point (FFP). The model for the forward problem is deduced based on a multiharmonic system matrix. Afterward, the sideband harmonics of the third harmonic $3f_{{0}}$ are measured for imaging. With 24 sideband harmonics for MPI, the bandwidth is about $24\times 33$ Hz = 792 Hz. An MPI scanner with a main gradient of 1.12 Tm ${}^{-{1}} \mu _{{0}}^{-{1}}$ is built for experiments. Phantom experiments are performed to evaluate the spatial resolution and limit of detection (LOD). The experimental results demonstrate that the proposed narrowband MPI approach based on a multiharmonic system matrix allows a spatial resolution of 1.5 and 1 mm for a gradient field of 0.56 and 1.12 Tm ${}^{-{1}} \mu _{{0}}^{-{1}}$ in $x$ - and $y$ -directions, respectively. The MPI scanner achieves an LOD of 45 ng Fe ( $5~\mu $ g (Fe)/mL) using synomag-D SPIONs at 8 mT.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Narrowband Magnetic Particle Imaging Based on Multiharmonic System Matrix
Magnetic particle imaging (MPI) is an emerging medical imaging technique for quantitatively visualizing the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs), which has shown great potential in biomedicine. In this study, we propose an approach of narrowband MPI based on a multiharmonic system matrix. A high-frequency ( $f_{{0}} =101$ kHz) AC magnetic field in the $x$ -direction is used to excite SPIONs to generate spectra, while a low-frequency ( $f_{\text {y}} =33$ Hz) AC magnetic field in the $y$ -direction is used to scan the field-free point (FFP). The model for the forward problem is deduced based on a multiharmonic system matrix. Afterward, the sideband harmonics of the third harmonic $3f_{{0}}$ are measured for imaging. With 24 sideband harmonics for MPI, the bandwidth is about $24\times 33$ Hz = 792 Hz. An MPI scanner with a main gradient of 1.12 Tm ${}^{-{1}} \mu _{{0}}^{-{1}}$ is built for experiments. Phantom experiments are performed to evaluate the spatial resolution and limit of detection (LOD). The experimental results demonstrate that the proposed narrowband MPI approach based on a multiharmonic system matrix allows a spatial resolution of 1.5 and 1 mm for a gradient field of 0.56 and 1.12 Tm ${}^{-{1}} \mu _{{0}}^{-{1}}$ in $x$ - and $y$ -directions, respectively. The MPI scanner achieves an LOD of 45 ng Fe ( $5~\mu $ g (Fe)/mL) using synomag-D SPIONs at 8 mT.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Investigation of YBCO Thin-Film Surface Impedance for THz Microscopy Using Josephson Junctions
Josephson junctions based on high-temperature su-perconductors enable the detection of terahertz (THz) radiation at frequencies up to 5 THz. Their current-voltage characteristics provide information on the incident intensity and frequency of gigahertz and terahertz radiation, with coupling eficiency enhanced through the use of integrated antennas. This detector, called a Josephson cantilever, is employed in our THz scanning microscope to map three-dimensional far-field patterns. The cantilevers are fabricated on lanthanum aluminate-strontium aluminum tantalate (LSAT) or magnesium (MgO) substrates with epitaxially grown yttrium barium copper oxide (YBCO) thin films. Focused-helium ion beam direct writing is used to write Josephson junctions in the antenna feed points. These narrowband u-shaped antennas are designed for specific resonant frequencies, requiring the determination of the YBCO's surface impedance. The temperature-dependent surface impedance of YBCO was determined using terahertz spectroscopy (300 GHz to 2 THz, 10 K to 300 K) and validated against measured antenna resonances that were compared to finite integration simulations in CST Studio Suite 2023. Finally, spatially resolved measurements at 1.4 THz demonstrate the imaging capabilities with symmetric Gaussian beam profiles.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Investigation of YBCO Thin-Film Surface Impedance for THz Microscopy Using Josephson Junctions
Josephson junctions based on high-temperature su-perconductors enable the detection of terahertz (THz) radiation at frequencies up to 5 THz. Their current-voltage characteristics provide information on the incident intensity and frequency of gigahertz and terahertz radiation, with coupling eficiency enhanced through the use of integrated antennas. This detector, called a Josephson cantilever, is employed in our THz scanning microscope to map three-dimensional far-field patterns. The cantilevers are fabricated on lanthanum aluminate-strontium aluminum tantalate (LSAT) or magnesium (MgO) substrates with epitaxially grown yttrium barium copper oxide (YBCO) thin films. Focused-helium ion beam direct writing is used to write Josephson junctions in the antenna feed points. These narrowband u-shaped antennas are designed for specific resonant frequencies, requiring the determination of the YBCO's surface impedance. The temperature-dependent surface impedance of YBCO was determined using terahertz spectroscopy (300 GHz to 2 THz, 10 K to 300 K) and validated against measured antenna resonances that were compared to finite integration simulations in CST Studio Suite 2023. Finally, spatially resolved measurements at 1.4 THz demonstrate the imaging capabilities with symmetric Gaussian beam profiles.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Toward a Voltage Standard Using YBa 2 Cu 3 O 7-x Josephson Junction Arrays Fabricated by He-FIB
Recent results with shunted YBa2Cu3O7-x Josephson junctions (JJs) fabricated using direct-writing by helium-focused ion beam (He-FIB) demonstrate that this technology is useful to achieve a YBa2Cu3O7-x voltage standard. By adding a shunt resistor via a subsequent lift-off step, the $\rm{{\mathit{R}}}_\rm{n}$ value and thereby the spread of the JJs can be reduced. These results were achieved with one large shunt across multiple JJs. This study presents different designs of shunt resistors, which allow measuring the JJs individually. The different shunt resistor designs are described and evaluated by comparing measurement results without and with the shunt resistor. These show the desired effect of controlling $\rm{{\mathit{R}}}_\rm{n}$, but also a change in $\rm{{\mathit{I}}}_\rm{c}$ is visible. The spread in parameters is investigated both without and with shunt resistors. Shapiro steps at gigahertz frequencies are presented for single JJs. The study concludes with a comparative measurement between a YBa2Cu3O7-x He-FIB JJ and a Josephson Arbitrary Waveform Synthesizer from PTB Braunschweig, showing a deviation of 0.05% and thus demonstrating its potential applicability.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Toward a Voltage Standard Using YBa 2 Cu 3 O 7-x Josephson Junction Arrays Fabricated by He-FIB
Recent results with shunted YBa2Cu3O7-x Josephson junctions (JJs) fabricated using direct-writing by helium-focused ion beam (He-FIB) demonstrate that this technology is useful to achieve a YBa2Cu3O7-x voltage standard. By adding a shunt resistor via a subsequent lift-off step, the $\rm{{\mathit{R}}}_\rm{n}$ value and thereby the spread of the JJs can be reduced. These results were achieved with one large shunt across multiple JJs. This study presents different designs of shunt resistors, which allow measuring the JJs individually. The different shunt resistor designs are described and evaluated by comparing measurement results without and with the shunt resistor. These show the desired effect of controlling $\rm{{\mathit{R}}}_\rm{n}$, but also a change in $\rm{{\mathit{I}}}_\rm{c}$ is visible. The spread in parameters is investigated both without and with shunt resistors. Shapiro steps at gigahertz frequencies are presented for single JJs. The study concludes with a comparative measurement between a YBa2Cu3O7-x He-FIB JJ and a Josephson Arbitrary Waveform Synthesizer from PTB Braunschweig, showing a deviation of 0.05% and thus demonstrating its potential applicability.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
THz Microscopy of Quantum Cascade Laser Radiation Using Josephson Junctions
Josephson junctions (JJs) embedded into the feed point of a thin film antenna made from yttrium barium copper oxide (YBCO) are well suited as a miniature sensor for GHzand THz-frequency fields. A spatially and frequency-resolved image of electromagnetic field intensity is obtained by scanning the region of interest. The sensor is read out by measuring the dc current-voltage (IV) characteristic of the JJ. Discrete frequencies together with their corresponding intensities can be extracted from measurements by evaluating the Shapiro steps in the IV domain. To extract a continuous spectrum from the IV characteristic, the numerical method of Hilbert transform spectroscopy is used and its applicability to our JJs is evaluated. As a benchmark of the setup's capabilities, radiation from a quantum cascade laser (QCL) THz source is characterized both spectrally and spatially. A frequency comb spectrum consistent with the QCL's cavity is revealed by Hilbert transform spectroscopy. The far field radiation patterns of two strong QCL modes are resolved individually and show different characteristics. Optical QCL feedback is observed when the sensor is brought in close proximity.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
THz Microscopy of Quantum Cascade Laser Radiation Using Josephson Junctions
Josephson junctions (JJs) embedded into the feed point of a thin film antenna made from yttrium barium copper oxide (YBCO) are well suited as a miniature sensor for GHzand THz-frequency fields. A spatially and frequency-resolved image of electromagnetic field intensity is obtained by scanning the region of interest. The sensor is read out by measuring the dc current-voltage (IV) characteristic of the JJ. Discrete frequencies together with their corresponding intensities can be extracted from measurements by evaluating the Shapiro steps in the IV domain. To extract a continuous spectrum from the IV characteristic, the numerical method of Hilbert transform spectroscopy is used and its applicability to our JJs is evaluated. As a benchmark of the setup's capabilities, radiation from a quantum cascade laser (QCL) THz source is characterized both spectrally and spatially. A frequency comb spectrum consistent with the QCL's cavity is revealed by Hilbert transform spectroscopy. The far field radiation patterns of two strong QCL modes are resolved individually and show different characteristics. Optical QCL feedback is observed when the sensor is brought in close proximity.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-6
Shunting YBa 2 Cu 3 O 7-x Josephson Junctions and Arrays Fabricated by He-FIB
Fabrication of YBa2Cu3O7-x Josephson junctions (JJs) using a direct-write helium-focused helium ion beam (He-FIB) technique has great potential for various applications due to tunable JJ parameters and arbitrary positioning. This technique allows placing multiple JJs in series to create JJ arrays. They could be used as a voltage standard that is operated at higher temperatures and driving frequencies than the currently used niobium-based JJ arrays. Small YBa2Cu3O7-x He-FIB JJ arrays with superposed Shapiro steps for up to three JJs have already been demonstrated. The number of JJs in the array was limited by the parameter spread of the individual JJs. This study presents WRspice simulations of JJ arrays, which indicate that the normal state resistance $R$n is the most crucial parameter to achieve flat Shapiro steps in JJ arrays. The idea of adding a shunt resistor to the JJ array to deal with the spread in $R$n values is investigated. A new design for GHz frequencies is presented, and the fabrication process is described. The properties of the shunt resistor are evaluated by van der Pauw measurements. Comparison of measurements with and without shunt resistor shows the desired effect of changing the total resistance of the JJ array while maintaining the critical current value. Finally, measurements of JJ arrays demonstrating superposed Shapiro steps at 20 k at GHz frequencies are presented.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-6
Shunting YBa 2 Cu 3 O 7-x Josephson Junctions and Arrays Fabricated by He-FIB
Fabrication of YBa2Cu3O7-x Josephson junctions (JJs) using a direct-write helium-focused helium ion beam (He-FIB) technique has great potential for various applications due to tunable JJ parameters and arbitrary positioning. This technique allows placing multiple JJs in series to create JJ arrays. They could be used as a voltage standard that is operated at higher temperatures and driving frequencies than the currently used niobium-based JJ arrays. Small YBa2Cu3O7-x He-FIB JJ arrays with superposed Shapiro steps for up to three JJs have already been demonstrated. The number of JJs in the array was limited by the parameter spread of the individual JJs. This study presents WRspice simulations of JJ arrays, which indicate that the normal state resistance $R$n is the most crucial parameter to achieve flat Shapiro steps in JJ arrays. The idea of adding a shunt resistor to the JJ array to deal with the spread in $R$n values is investigated. A new design for GHz frequencies is presented, and the fabrication process is described. The properties of the shunt resistor are evaluated by van der Pauw measurements. Comparison of measurements with and without shunt resistor shows the desired effect of changing the total resistance of the JJ array while maintaining the critical current value. Finally, measurements of JJ arrays demonstrating superposed Shapiro steps at 20 k at GHz frequencies are presented.
- Open Access
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Cryogenic Evaluation of a Digital-to-Analog Converter for a Trapped-Ion Quantum Computer
This paper presents a Digital-to-Analog Converter (DAC) for shuttling operations in a trapped-ion quantum computer (TIQC) measured at 4.6 K.We provide an extensive analysis and comparison of measured characteristics at room temperature (RT) versus those at cryogenic temperature (CT), particularly focusing on the DAC’s static and dynamic behavior, as well as its noise performance. By making well-conceived analytical design choices, we show that the DAC’s performance at CT can match its performance at RT. This is achieved through sufficient design margins, the selection of suitable components, and the adjustment of biasing voltages. The investigated chip features a 12 bit, resistive R-2R ladder-based DAC, which also comprises an input buffer for the DAC’s reference voltage and a simplistic SPI to read the digital control words. Implemented in Infineon’s 130nm Bipolar-CMOS-DMOS (BCD) technology, the DAC consumes 1.1mW from a 1.5V power supply at RT. Its power consumption increases to around 1.5mW at CT due to necessary biasing adjustments. The DAC’s linearity, characterized by its Differential-Non-Linearity (DNL) and Integral-Non-Linearity (INL) remains almost unchanged across temperatures, aligning with its Spurious-Free Dynamic Range (SFDR). The slew-rate (SR) decreases toward CT compared to RT. While the thermal noise floor also decreases, the low-frequency noise increases at CT. Overall, this leads to a slight decrease in the DAC’s noise performance at 4.6K.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Open AccessCryogenic Evaluation of a Digital-to-Analog Converter for a Trapped-Ion Quantum Computer
This paper presents a Digital-to-Analog Converter (DAC) for shuttling operations in a trapped-ion quantum computer (TIQC) measured at 4.6 K.We provide an extensive analysis and comparison of measured characteristics at room temperature (RT) versus those at cryogenic temperature (CT), particularly focusing on the DAC’s static and dynamic behavior, as well as its noise performance. By making well-conceived analytical design choices, we show that the DAC’s performance at CT can match its performance at RT. This is achieved through sufficient design margins, the selection of suitable components, and the adjustment of biasing voltages. The investigated chip features a 12 bit, resistive R-2R ladder-based DAC, which also comprises an input buffer for the DAC’s reference voltage and a simplistic SPI to read the digital control words. Implemented in Infineon’s 130nm Bipolar-CMOS-DMOS (BCD) technology, the DAC consumes 1.1mW from a 1.5V power supply at RT. Its power consumption increases to around 1.5mW at CT due to necessary biasing adjustments. The DAC’s linearity, characterized by its Differential-Non-Linearity (DNL) and Integral-Non-Linearity (INL) remains almost unchanged across temperatures, aligning with its Spurious-Free Dynamic Range (SFDR). The slew-rate (SR) decreases toward CT compared to RT. While the thermal noise floor also decreases, the low-frequency noise increases at CT. Overall, this leads to a slight decrease in the DAC’s noise performance at 4.6K.
- Open Access
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance–voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system’s measurement capability for quantum computing and other applications.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Open AccessMeasurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance–voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system’s measurement capability for quantum computing and other applications.