Paul Julius Ritter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Julius Ritter has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Hampel
National Institute of Standards and Technology 1 , Boulder, Colorado 80305
13 shared publications - Meinhard Schilling
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
13 shared publications - Max Pröpper
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
9 shared publications - Marius Neumann
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
7 shared publications - Marc-André Tucholke
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
6 shared publications - Dominik Hanisch
Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany
5 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (5) , 528-532
A Cross-Voltage-Domain Instrumentation-Amplifier ESP Unit for Ion Shuttling at 5 K
This work presents a cross-voltage domain instrumentation amplifier (INA) based electrode signal processing (ESP) unit for providing full-scale (FS) voltage ranges in excess of 10V at the electrodes of a trapped-ion quantum computer (TIQC) at cryogenic temperatures (CT). It carries out a systematic comparison between a reference design and the proposed INA approach. While both designs achieve their targeted specifications at room temperature (RT), the reference ESP unit’s linearity and noise performance deteriorates at CT. In contrast, the proposed INA-based ESP unit maintains its linearity and noise performance down to 5 K. Both designs are fabricated in a 130nm BCD technology and are evaluated under identical measurement conditions. Measurement results demonstrate that the proposed INA-based ESP unit greatly improves upon the reference design. At 5K its integrated RMS noise improves from 10.2 mVrms to 0.9 mVrms, while its SFDR improves by 25 dB to 49.9 dB and its power is reduced by about 11mW down to 19.5mW.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (5) , 528-532
Open AccessA Cross-Voltage-Domain Instrumentation-Amplifier ESP Unit for Ion Shuttling at 5 K
This work presents a cross-voltage domain instrumentation amplifier (INA) based electrode signal processing (ESP) unit for providing full-scale (FS) voltage ranges in excess of 10V at the electrodes of a trapped-ion quantum computer (TIQC) at cryogenic temperatures (CT). It carries out a systematic comparison between a reference design and the proposed INA approach. While both designs achieve their targeted specifications at room temperature (RT), the reference ESP unit’s linearity and noise performance deteriorates at CT. In contrast, the proposed INA-based ESP unit maintains its linearity and noise performance down to 5 K. Both designs are fabricated in a 130nm BCD technology and are evaluated under identical measurement conditions. Measurement results demonstrate that the proposed INA-based ESP unit greatly improves upon the reference design. At 5K its integrated RMS noise improves from 10.2 mVrms to 0.9 mVrms, while its SFDR improves by 25 dB to 49.9 dB and its power is reduced by about 11mW down to 19.5mW.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Investigation of YBCO Thin-Film Surface Impedance for THz Microscopy Using Josephson Junctions
Josephson junctions based on high-temperature su-perconductors enable the detection of terahertz (THz) radiation at frequencies up to 5 THz. Their current-voltage characteristics provide information on the incident intensity and frequency of gigahertz and terahertz radiation, with coupling eficiency enhanced through the use of integrated antennas. This detector, called a Josephson cantilever, is employed in our THz scanning microscope to map three-dimensional far-field patterns. The cantilevers are fabricated on lanthanum aluminate-strontium aluminum tantalate (LSAT) or magnesium (MgO) substrates with epitaxially grown yttrium barium copper oxide (YBCO) thin films. Focused-helium ion beam direct writing is used to write Josephson junctions in the antenna feed points. These narrowband u-shaped antennas are designed for specific resonant frequencies, requiring the determination of the YBCO's surface impedance. The temperature-dependent surface impedance of YBCO was determined using terahertz spectroscopy (300 GHz to 2 THz, 10 K to 300 K) and validated against measured antenna resonances that were compared to finite integration simulations in CST Studio Suite 2023. Finally, spatially resolved measurements at 1.4 THz demonstrate the imaging capabilities with symmetric Gaussian beam profiles.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Investigation of YBCO Thin-Film Surface Impedance for THz Microscopy Using Josephson Junctions
Josephson junctions based on high-temperature su-perconductors enable the detection of terahertz (THz) radiation at frequencies up to 5 THz. Their current-voltage characteristics provide information on the incident intensity and frequency of gigahertz and terahertz radiation, with coupling eficiency enhanced through the use of integrated antennas. This detector, called a Josephson cantilever, is employed in our THz scanning microscope to map three-dimensional far-field patterns. The cantilevers are fabricated on lanthanum aluminate-strontium aluminum tantalate (LSAT) or magnesium (MgO) substrates with epitaxially grown yttrium barium copper oxide (YBCO) thin films. Focused-helium ion beam direct writing is used to write Josephson junctions in the antenna feed points. These narrowband u-shaped antennas are designed for specific resonant frequencies, requiring the determination of the YBCO's surface impedance. The temperature-dependent surface impedance of YBCO was determined using terahertz spectroscopy (300 GHz to 2 THz, 10 K to 300 K) and validated against measured antenna resonances that were compared to finite integration simulations in CST Studio Suite 2023. Finally, spatially resolved measurements at 1.4 THz demonstrate the imaging capabilities with symmetric Gaussian beam profiles.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Toward a Voltage Standard Using YBa 2 Cu 3 O 7-x Josephson Junction Arrays Fabricated by He-FIB
Recent results with shunted YBa2Cu3O7-x Josephson junctions (JJs) fabricated using direct-writing by helium-focused ion beam (He-FIB) demonstrate that this technology is useful to achieve a YBa2Cu3O7-x voltage standard. By adding a shunt resistor via a subsequent lift-off step, the $\rm{{\mathit{R}}}_\rm{n}$ value and thereby the spread of the JJs can be reduced. These results were achieved with one large shunt across multiple JJs. This study presents different designs of shunt resistors, which allow measuring the JJs individually. The different shunt resistor designs are described and evaluated by comparing measurement results without and with the shunt resistor. These show the desired effect of controlling $\rm{{\mathit{R}}}_\rm{n}$, but also a change in $\rm{{\mathit{I}}}_\rm{c}$ is visible. The spread in parameters is investigated both without and with shunt resistors. Shapiro steps at gigahertz frequencies are presented for single JJs. The study concludes with a comparative measurement between a YBa2Cu3O7-x He-FIB JJ and a Josephson Arbitrary Waveform Synthesizer from PTB Braunschweig, showing a deviation of 0.05% and thus demonstrating its potential applicability.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Toward a Voltage Standard Using YBa 2 Cu 3 O 7-x Josephson Junction Arrays Fabricated by He-FIB
Recent results with shunted YBa2Cu3O7-x Josephson junctions (JJs) fabricated using direct-writing by helium-focused ion beam (He-FIB) demonstrate that this technology is useful to achieve a YBa2Cu3O7-x voltage standard. By adding a shunt resistor via a subsequent lift-off step, the $\rm{{\mathit{R}}}_\rm{n}$ value and thereby the spread of the JJs can be reduced. These results were achieved with one large shunt across multiple JJs. This study presents different designs of shunt resistors, which allow measuring the JJs individually. The different shunt resistor designs are described and evaluated by comparing measurement results without and with the shunt resistor. These show the desired effect of controlling $\rm{{\mathit{R}}}_\rm{n}$, but also a change in $\rm{{\mathit{I}}}_\rm{c}$ is visible. The spread in parameters is investigated both without and with shunt resistors. Shapiro steps at gigahertz frequencies are presented for single JJs. The study concludes with a comparative measurement between a YBa2Cu3O7-x He-FIB JJ and a Josephson Arbitrary Waveform Synthesizer from PTB Braunschweig, showing a deviation of 0.05% and thus demonstrating its potential applicability.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
THz Microscopy of Quantum Cascade Laser Radiation Using Josephson Junctions
Josephson junctions (JJs) embedded into the feed point of a thin film antenna made from yttrium barium copper oxide (YBCO) are well suited as a miniature sensor for GHzand THz-frequency fields. A spatially and frequency-resolved image of electromagnetic field intensity is obtained by scanning the region of interest. The sensor is read out by measuring the dc current-voltage (IV) characteristic of the JJ. Discrete frequencies together with their corresponding intensities can be extracted from measurements by evaluating the Shapiro steps in the IV domain. To extract a continuous spectrum from the IV characteristic, the numerical method of Hilbert transform spectroscopy is used and its applicability to our JJs is evaluated. As a benchmark of the setup's capabilities, radiation from a quantum cascade laser (QCL) THz source is characterized both spectrally and spatially. A frequency comb spectrum consistent with the QCL's cavity is revealed by Hilbert transform spectroscopy. The far field radiation patterns of two strong QCL modes are resolved individually and show different characteristics. Optical QCL feedback is observed when the sensor is brought in close proximity.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
THz Microscopy of Quantum Cascade Laser Radiation Using Josephson Junctions
Josephson junctions (JJs) embedded into the feed point of a thin film antenna made from yttrium barium copper oxide (YBCO) are well suited as a miniature sensor for GHzand THz-frequency fields. A spatially and frequency-resolved image of electromagnetic field intensity is obtained by scanning the region of interest. The sensor is read out by measuring the dc current-voltage (IV) characteristic of the JJ. Discrete frequencies together with their corresponding intensities can be extracted from measurements by evaluating the Shapiro steps in the IV domain. To extract a continuous spectrum from the IV characteristic, the numerical method of Hilbert transform spectroscopy is used and its applicability to our JJs is evaluated. As a benchmark of the setup's capabilities, radiation from a quantum cascade laser (QCL) THz source is characterized both spectrally and spatially. A frequency comb spectrum consistent with the QCL's cavity is revealed by Hilbert transform spectroscopy. The far field radiation patterns of two strong QCL modes are resolved individually and show different characteristics. Optical QCL feedback is observed when the sensor is brought in close proximity.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-6
Shunting YBa 2 Cu 3 O 7-x Josephson Junctions and Arrays Fabricated by He-FIB
Fabrication of YBa2Cu3O7-x Josephson junctions (JJs) using a direct-write helium-focused helium ion beam (He-FIB) technique has great potential for various applications due to tunable JJ parameters and arbitrary positioning. This technique allows placing multiple JJs in series to create JJ arrays. They could be used as a voltage standard that is operated at higher temperatures and driving frequencies than the currently used niobium-based JJ arrays. Small YBa2Cu3O7-x He-FIB JJ arrays with superposed Shapiro steps for up to three JJs have already been demonstrated. The number of JJs in the array was limited by the parameter spread of the individual JJs. This study presents WRspice simulations of JJ arrays, which indicate that the normal state resistance $R$n is the most crucial parameter to achieve flat Shapiro steps in JJ arrays. The idea of adding a shunt resistor to the JJ array to deal with the spread in $R$n values is investigated. A new design for GHz frequencies is presented, and the fabrication process is described. The properties of the shunt resistor are evaluated by van der Pauw measurements. Comparison of measurements with and without shunt resistor shows the desired effect of changing the total resistance of the JJ array while maintaining the critical current value. Finally, measurements of JJ arrays demonstrating superposed Shapiro steps at 20 k at GHz frequencies are presented.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-6
Shunting YBa 2 Cu 3 O 7-x Josephson Junctions and Arrays Fabricated by He-FIB
Fabrication of YBa2Cu3O7-x Josephson junctions (JJs) using a direct-write helium-focused helium ion beam (He-FIB) technique has great potential for various applications due to tunable JJ parameters and arbitrary positioning. This technique allows placing multiple JJs in series to create JJ arrays. They could be used as a voltage standard that is operated at higher temperatures and driving frequencies than the currently used niobium-based JJ arrays. Small YBa2Cu3O7-x He-FIB JJ arrays with superposed Shapiro steps for up to three JJs have already been demonstrated. The number of JJs in the array was limited by the parameter spread of the individual JJs. This study presents WRspice simulations of JJ arrays, which indicate that the normal state resistance $R$n is the most crucial parameter to achieve flat Shapiro steps in JJ arrays. The idea of adding a shunt resistor to the JJ array to deal with the spread in $R$n values is investigated. A new design for GHz frequencies is presented, and the fabrication process is described. The properties of the shunt resistor are evaluated by van der Pauw measurements. Comparison of measurements with and without shunt resistor shows the desired effect of changing the total resistance of the JJ array while maintaining the critical current value. Finally, measurements of JJ arrays demonstrating superposed Shapiro steps at 20 k at GHz frequencies are presented.
- Open Access
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Cryogenic Evaluation of a Digital-to-Analog Converter for a Trapped-Ion Quantum Computer
This paper presents a Digital-to-Analog Converter (DAC) for shuttling operations in a trapped-ion quantum computer (TIQC) measured at 4.6 K.We provide an extensive analysis and comparison of measured characteristics at room temperature (RT) versus those at cryogenic temperature (CT), particularly focusing on the DAC’s static and dynamic behavior, as well as its noise performance. By making well-conceived analytical design choices, we show that the DAC’s performance at CT can match its performance at RT. This is achieved through sufficient design margins, the selection of suitable components, and the adjustment of biasing voltages. The investigated chip features a 12 bit, resistive R-2R ladder-based DAC, which also comprises an input buffer for the DAC’s reference voltage and a simplistic SPI to read the digital control words. Implemented in Infineon’s 130nm Bipolar-CMOS-DMOS (BCD) technology, the DAC consumes 1.1mW from a 1.5V power supply at RT. Its power consumption increases to around 1.5mW at CT due to necessary biasing adjustments. The DAC’s linearity, characterized by its Differential-Non-Linearity (DNL) and Integral-Non-Linearity (INL) remains almost unchanged across temperatures, aligning with its Spurious-Free Dynamic Range (SFDR). The slew-rate (SR) decreases toward CT compared to RT. While the thermal noise floor also decreases, the low-frequency noise increases at CT. Overall, this leads to a slight decrease in the DAC’s noise performance at 4.6K.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Open AccessCryogenic Evaluation of a Digital-to-Analog Converter for a Trapped-Ion Quantum Computer
This paper presents a Digital-to-Analog Converter (DAC) for shuttling operations in a trapped-ion quantum computer (TIQC) measured at 4.6 K.We provide an extensive analysis and comparison of measured characteristics at room temperature (RT) versus those at cryogenic temperature (CT), particularly focusing on the DAC’s static and dynamic behavior, as well as its noise performance. By making well-conceived analytical design choices, we show that the DAC’s performance at CT can match its performance at RT. This is achieved through sufficient design margins, the selection of suitable components, and the adjustment of biasing voltages. The investigated chip features a 12 bit, resistive R-2R ladder-based DAC, which also comprises an input buffer for the DAC’s reference voltage and a simplistic SPI to read the digital control words. Implemented in Infineon’s 130nm Bipolar-CMOS-DMOS (BCD) technology, the DAC consumes 1.1mW from a 1.5V power supply at RT. Its power consumption increases to around 1.5mW at CT due to necessary biasing adjustments. The DAC’s linearity, characterized by its Differential-Non-Linearity (DNL) and Integral-Non-Linearity (INL) remains almost unchanged across temperatures, aligning with its Spurious-Free Dynamic Range (SFDR). The slew-rate (SR) decreases toward CT compared to RT. While the thermal noise floor also decreases, the low-frequency noise increases at CT. Overall, this leads to a slight decrease in the DAC’s noise performance at 4.6K.
- Open Access
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance–voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system’s measurement capability for quantum computing and other applications.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Open AccessMeasurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance–voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system’s measurement capability for quantum computing and other applications.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
High-$T_{\mathrm{c}}$ Josephson Junction Arrays Fabricated by He-FIB
The development of a fabrication process for Josephson junctions (JJs) using a direct-write helium-focused ion beam (He-FIB) technique provides the opportunity to control parameters such as the critical current $I_{\mathrm{c}}$ and normal-state resistance $R_{\mathrm{n}}$ of individual JJs in YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJ arrays. Such arrays could be used as a voltage calibration standard that is operated at higher temperatures and higher driving frequencies than the currently used niobium JJ arrays. This study presents the fabrication process of 79 YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJs in a meander array design using a direct writing He-FIB process with the same irradiation dose for all JJs. In this design, each of the JJs can be measured individually, and adjacent JJs that exhibit similar and suitable parameters for a voltage standard array can be measured in series. The scattering of the JJ parameters was investigated at 5 K and resulted in a spread in $I_{\mathrm{c}}$ of about 60% and in $R_{\mathrm{n}}$ of 25%. However, a couple of subarrays with a spread lower than 10% could be found. In addition, these JJ subarrays were irradiated with high-frequency radiation in the GHz and THz range at a temperature of 20 K and synchronization of up to three JJs was observed in both frequency ranges.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
High-$T_{\mathrm{c}}$ Josephson Junction Arrays Fabricated by He-FIB
The development of a fabrication process for Josephson junctions (JJs) using a direct-write helium-focused ion beam (He-FIB) technique provides the opportunity to control parameters such as the critical current $I_{\mathrm{c}}$ and normal-state resistance $R_{\mathrm{n}}$ of individual JJs in YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJ arrays. Such arrays could be used as a voltage calibration standard that is operated at higher temperatures and higher driving frequencies than the currently used niobium JJ arrays. This study presents the fabrication process of 79 YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJs in a meander array design using a direct writing He-FIB process with the same irradiation dose for all JJs. In this design, each of the JJs can be measured individually, and adjacent JJs that exhibit similar and suitable parameters for a voltage standard array can be measured in series. The scattering of the JJ parameters was investigated at 5 K and resulted in a spread in $I_{\mathrm{c}}$ of about 60% and in $R_{\mathrm{n}}$ of 25%. However, a couple of subarrays with a spread lower than 10% could be found. In addition, these JJ subarrays were irradiated with high-frequency radiation in the GHz and THz range at a temperature of 20 K and synchronization of up to three JJs was observed in both frequency ranges.
- 12 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
THz Properties of He-FIB YBa2Cu3O7-x Josephson Junctions
Josephson junctions with customizable parameters, including critical current $I$ c and normal state resistance $R$ n , hold great promise across a wide range of applications. Notably, high-temperature superconductors like YBa 2 Cu 3 O 7-x have been interesting since their discovery due to their simplified cooling requirements. YBa 2 Cu 3 O 7-x Josephson junctions can operate within the terahertz (THz) frequency range, rendering them highly suitable for various applications. To maximize their suitability at these high frequencies, it is imperative to precisely determine their THz parameters. Helium focused ion beam (He-FIB) technology is a very promising fabrication method for customizable Josephson junctions. It allows precise control of the He-FIB dose during the fabrication of Josephson junctions and facilitates the fine-tuning of I c and R n . This study presents the fabrication process of YBa 2 Cu 3 O 7-x Josephson junctions using He-FIB irradiation and explores the variations of parameters with dose, evaluating their suitability within the THz range. Also, the scattering of parameters of He-FIB Josephson junctions fabricated with the same He-FIB dose is investigated. Additionally, we examine the high-frequency properties of such junctions and scrutinize the associated Shapiro steps within the THz frequency spectrum. We observe an exponential relationship between I c and the He-FIB dose. Moreover, Shapiro steps emerge under the influence of radiation spanning from 40 GHz to as high as 1.4 THz.
- 12 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
THz Properties of He-FIB YBa2Cu3O7-x Josephson Junctions
Josephson junctions with customizable parameters, including critical current $I$ c and normal state resistance $R$ n , hold great promise across a wide range of applications. Notably, high-temperature superconductors like YBa 2 Cu 3 O 7-x have been interesting since their discovery due to their simplified cooling requirements. YBa 2 Cu 3 O 7-x Josephson junctions can operate within the terahertz (THz) frequency range, rendering them highly suitable for various applications. To maximize their suitability at these high frequencies, it is imperative to precisely determine their THz parameters. Helium focused ion beam (He-FIB) technology is a very promising fabrication method for customizable Josephson junctions. It allows precise control of the He-FIB dose during the fabrication of Josephson junctions and facilitates the fine-tuning of I c and R n . This study presents the fabrication process of YBa 2 Cu 3 O 7-x Josephson junctions using He-FIB irradiation and explores the variations of parameters with dose, evaluating their suitability within the THz range. Also, the scattering of parameters of He-FIB Josephson junctions fabricated with the same He-FIB dose is investigated. Additionally, we examine the high-frequency properties of such junctions and scrutinize the associated Shapiro steps within the THz frequency spectrum. We observe an exponential relationship between I c and the He-FIB dose. Moreover, Shapiro steps emerge under the influence of radiation spanning from 40 GHz to as high as 1.4 THz.
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
THz Microscopy With Josephson Cantilevers for Characterization of Additive Manufactured Spiral Phase Plates
Josephson cantilevers from high-temperature superconductors are versatile sensors to measure frequency and power of microwave and terahertz radiation in the range of 1 GHz to about 5 THz. They consist of at least one Josephson junction, which is fabricated from the high-temperature superconductor yttrium barium copper oxide (YBCO). The Josephson cantilever is mounted on a positioning system inside a vacuum chamber to perform three-dimensional scanning measurements in the THz microscope. The frequency and the power of external radiation can be determined from the recorded data by evaluating the occurring Shapiro steps. In this work, spiral phase plates (SPPs) optimized for the terahertz regime were additively manufactured with a fused filament fabrication 3D printer. Multiple SPPs were investigated and the results of two of them are shown, each made of a different thermoplastic. The SPPs are designed to transform Gaussian light beams into twisted light beams with an orbital angular momentum. An optically pumped molecular gas far-infrared laser system with difluoromethane as lasing medium can be employed as radiation source to generate frequencies between 1 THz and 1.6 THz with powers up to 125 mW. The beam is coupled into the THz microscope via quasi-optical windows and an evacuated optical path. The SPP is placed near the far-infrared laser to measure the far-field distribution. In this work, measurement results based on superconducting Josephson cantilevers are obtained with our unique THz microscope setup to characterize SPPs. The results present an important contribution for the evaluation of the design and the fabrication process of SPPs and showcase one of the multiple measurement modes of the THz microscope.
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
THz Microscopy With Josephson Cantilevers for Characterization of Additive Manufactured Spiral Phase Plates
Josephson cantilevers from high-temperature superconductors are versatile sensors to measure frequency and power of microwave and terahertz radiation in the range of 1 GHz to about 5 THz. They consist of at least one Josephson junction, which is fabricated from the high-temperature superconductor yttrium barium copper oxide (YBCO). The Josephson cantilever is mounted on a positioning system inside a vacuum chamber to perform three-dimensional scanning measurements in the THz microscope. The frequency and the power of external radiation can be determined from the recorded data by evaluating the occurring Shapiro steps. In this work, spiral phase plates (SPPs) optimized for the terahertz regime were additively manufactured with a fused filament fabrication 3D printer. Multiple SPPs were investigated and the results of two of them are shown, each made of a different thermoplastic. The SPPs are designed to transform Gaussian light beams into twisted light beams with an orbital angular momentum. An optically pumped molecular gas far-infrared laser system with difluoromethane as lasing medium can be employed as radiation source to generate frequencies between 1 THz and 1.6 THz with powers up to 125 mW. The beam is coupled into the THz microscope via quasi-optical windows and an evacuated optical path. The SPP is placed near the far-infrared laser to measure the far-field distribution. In this work, measurement results based on superconducting Josephson cantilevers are obtained with our unique THz microscope setup to characterize SPPs. The results present an important contribution for the evaluation of the design and the fabrication process of SPPs and showcase one of the multiple measurement modes of the THz microscope.