Yiping Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yiping Liu has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Licheng Zhou
School of Civil Engineering and Transportation, South China University of Technology, No. 381, Wushan Road, Guangzhou 510641, China
29 shared publications - Liqun Tang
South China University of Technology
28 shared publications - Zhenyu Jiang
Department of Engineering Mechanics, School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
26 shared publications - Bao Yang
Department of Engineering Mechanics, School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
22 shared publications - Zejia Liu
School of Civil Engineering and Transportation, South China University of Technology, No. 381, Wushan Road, Guangzhou 510641, China
20 shared publications Zejia Liu
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
14 shared publications
Latest Publications
- Open Access
High-Performance Riveted Complementary-Structure Rotating Triboelectric Nanogenerator for Energy Harvesting from Slow-Speed Water Flows
Triboelectric nanogenerators (TENGs) are promising for harvesting low-frequency mechanical energy, but rotating TENGs (R-TENGs) driven by low-speed water flow remain constrained by limited driving torque, sliding-contact losses, and rotating-system stability. Here, a three-dimensional (3D) riveted complementary-structure rotating triboelectric nanogenerator (RCSR-TENG) is proposed for low-speed water-flow energy harvesting. A semi-analytical formulation incorporating a force-dependent real-contact fraction is developed to describe the coupled relationships among output voltage, transferred charge, rotation angle, and contact force. Because the contact parameters were not independently calibrated, the formulation is used for sensitivity and trend analysis rather than as a quantitatively validated predictive model. For the single prototype tested for each configuration, at 1000 rpm under the fixed effective measurement load of 9 MΩ, the RCSR-TENG produced a peak output power of 544 μW, compared with 304 μW for the flat R-TENG, representing an increase of approximately 79%. The same RCSR-TENG prototype maintained a stable voltage amplitude of over 150,000 rotation cycles. When coupled to a fully passive flapping-foil collector in a 0.55 m s−1 water flow, the system generated periodic electrical output with a peak area-normalized power exceeding 5000 μW m−2. These results demonstrate the structural-performance advantage of the riveted complementary design and its proof-of-concept applicability to low-speed water-flow energy harvesting.
Open AccessHigh-Performance Riveted Complementary-Structure Rotating Triboelectric Nanogenerator for Energy Harvesting from Slow-Speed Water Flows
Triboelectric nanogenerators (TENGs) are promising for harvesting low-frequency mechanical energy, but rotating TENGs (R-TENGs) driven by low-speed water flow remain constrained by limited driving torque, sliding-contact losses, and rotating-system stability. Here, a three-dimensional (3D) riveted complementary-structure rotating triboelectric nanogenerator (RCSR-TENG) is proposed for low-speed water-flow energy harvesting. A semi-analytical formulation incorporating a force-dependent real-contact fraction is developed to describe the coupled relationships among output voltage, transferred charge, rotation angle, and contact force. Because the contact parameters were not independently calibrated, the formulation is used for sensitivity and trend analysis rather than as a quantitatively validated predictive model. For the single prototype tested for each configuration, at 1000 rpm under the fixed effective measurement load of 9 MΩ, the RCSR-TENG produced a peak output power of 544 μW, compared with 304 μW for the flat R-TENG, representing an increase of approximately 79%. The same RCSR-TENG prototype maintained a stable voltage amplitude of over 150,000 rotation cycles. When coupled to a fully passive flapping-foil collector in a 0.55 m s−1 water flow, the system generated periodic electrical output with a peak area-normalized power exceeding 5000 μW m−2. These results demonstrate the structural-performance advantage of the riveted complementary design and its proof-of-concept applicability to low-speed water-flow energy harvesting.
- 1 May 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (5) , 055010
High performance flow-restricted plate sensor with bidirectional sensing ability for smart wearable respiratory monitoring
Respiratory diseases have become one of the most prevalent health conditions worldwide. Respiration contains rich physiological and pathological information and smart respiratory monitoring holds numerous promising applications in the fields of medical healthcare, sports, and general wellness. However, existing respiratory monitoring systems are still limited by insufficient accuracy, bulky configurations, and poor wearing comfort. In this study, we developed a novel miniature flow-restricted plate respiratory sensor with bidirectional sensing ability and high sensitivity for quantitative respiratory monitoring. Theoretical models and numerical simulations were developed and utilized to guide the structural design. After structural optimization, the sensor achieves a favorable balance between pressure sensitivity and respiratory resistance. A calibration system was also developed based on multiple piston devices, stepper motors, a camera, and digital image correlation for displacement monitoring. This calibration system can generate both constant and variable airflow to simulate human respiration. Average accuracies of the sensor in terms of ventilation and airflow velocity reach up to 97% under controlled calibration conditions in laboratory settings. A design framework for integrating the proposed sensor into a lightweight and wearable respiratory monitoring platform is established. Multiple scenarios including resting postures, running, and cycling demonstrate the feasibility of this lightweight and wearable respiratory monitoring approach.
- 1 May 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (5) , 055010
High performance flow-restricted plate sensor with bidirectional sensing ability for smart wearable respiratory monitoring
Respiratory diseases have become one of the most prevalent health conditions worldwide. Respiration contains rich physiological and pathological information and smart respiratory monitoring holds numerous promising applications in the fields of medical healthcare, sports, and general wellness. However, existing respiratory monitoring systems are still limited by insufficient accuracy, bulky configurations, and poor wearing comfort. In this study, we developed a novel miniature flow-restricted plate respiratory sensor with bidirectional sensing ability and high sensitivity for quantitative respiratory monitoring. Theoretical models and numerical simulations were developed and utilized to guide the structural design. After structural optimization, the sensor achieves a favorable balance between pressure sensitivity and respiratory resistance. A calibration system was also developed based on multiple piston devices, stepper motors, a camera, and digital image correlation for displacement monitoring. This calibration system can generate both constant and variable airflow to simulate human respiration. Average accuracies of the sensor in terms of ventilation and airflow velocity reach up to 97% under controlled calibration conditions in laboratory settings. A design framework for integrating the proposed sensor into a lightweight and wearable respiratory monitoring platform is established. Multiple scenarios including resting postures, running, and cycling demonstrate the feasibility of this lightweight and wearable respiratory monitoring approach.
- 5 November 2025
- Published by Elsevier in Engineering Structures
- Vol. 346
An interactive multi-task learning model for multi-channel strain data reconstruction in SHM
- 5 November 2025
- Published by Elsevier in Engineering Structures
- Vol. 346
An interactive multi-task learning model for multi-channel strain data reconstruction in SHM
- Open Access
- 23 October 2025
- Published by MDPI AG in Electronic Materials
- Vol. 6 (4) , 16
Recent Advances in Triboelectric Materials for Active Health Applications
Triboelectric materials can convert irregular mechanical stimuli from human motion or environmental sources into high surface charge densities and instantaneous electrical outputs. Their intrinsic properties, such as flexibility, stretchability, chemical tunability, and compatibility with diverse substrates, play a critical role in determining the efficiency and reliability of triboelectric devices. In the context of active health, triboelectric materials not only serve as the core functional layers for self-powered sensing but also enable real-time physiological monitoring, motion tracking, and human–machine interaction by directly transducing biomechanical signals into electrical information. Soft triboelectric sensors exhibit high sensitivity, wide operational ranges, excellent biocompatibility, and wearability, making them highly promising for active health monitoring applications. Despite these advantages, challenges remain in enhancing surface charge density, achieving effective signal multiplexing, and ensuring long-term stability. This review provides a comprehensive overview of triboelectric mechanisms, working modes, influencing factors, performance enhancement strategies, and wearable health applications. Finally, it systematically summarizes the key improvement approaches and future development directions of triboelectric materials for active health, offering valuable guidance for advancing wearable self-powered biosensors.
- 23 October 2025
- Published by MDPI AG in Electronic Materials
- Vol. 6 (4) , 16
Open AccessRecent Advances in Triboelectric Materials for Active Health Applications
Triboelectric materials can convert irregular mechanical stimuli from human motion or environmental sources into high surface charge densities and instantaneous electrical outputs. Their intrinsic properties, such as flexibility, stretchability, chemical tunability, and compatibility with diverse substrates, play a critical role in determining the efficiency and reliability of triboelectric devices. In the context of active health, triboelectric materials not only serve as the core functional layers for self-powered sensing but also enable real-time physiological monitoring, motion tracking, and human–machine interaction by directly transducing biomechanical signals into electrical information. Soft triboelectric sensors exhibit high sensitivity, wide operational ranges, excellent biocompatibility, and wearability, making them highly promising for active health monitoring applications. Despite these advantages, challenges remain in enhancing surface charge density, achieving effective signal multiplexing, and ensuring long-term stability. This review provides a comprehensive overview of triboelectric mechanisms, working modes, influencing factors, performance enhancement strategies, and wearable health applications. Finally, it systematically summarizes the key improvement approaches and future development directions of triboelectric materials for active health, offering valuable guidance for advancing wearable self-powered biosensors.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 184-195
An Efficient FoG-M3 Method for Self-Adaptive Labeling and Predicting Freezing of Gait
Freezing of gait (FoG) is a common motor impairment that occurs as Parkinson's disease patients enter the moderate stage or higher, leading to a high risk of falls. Although previous methods have accurately identified FoG, significant challenges remain in predicting it. These challenges include difficulties in labeling Pre-FoG due to its personalization, sudden onset, and variability; the imbalance between the amount of FoG and normal gait data; and inadequate feature representation by the model. To address these challenges, we introduce a deep learning-based method for FoG prediction, named FoG-M3 (Mixup, MoCo, and MU-Net). This method employs a non-fixed length for Pre-FoG rather than a fixed length, allowing for more accurate labeling. To address the long-tail issue in the dataset, we integrated FoG-Mix with U-Net and the Mamba module. Additionally, the FoG-MoCo contrastive learning strategy was applied to enhance the model's representational capacity. The overall prediction accuracy reaches 95% on the Daphnet dataset and 93% on the BHXC dataset. Pre-FoG prediction accuracy also achieves approximately 90% on both datasets, surpassing the performance of FoG-Net, ResNeXt, and contrastive learning-based ResNet. Using the proposed method, we can predict FoG occurrences with enough time for posture adjustments, approximately 6 seconds before onset, which is more than typically available to Parkinson's disease patients. Therefore, the FoG-M3 method can predict Pre-FoG with high accuracy and efficiency, demonstrating substantial potential for use in Parkinson's disease rehabilitation.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 184-195
An Efficient FoG-M3 Method for Self-Adaptive Labeling and Predicting Freezing of Gait
Freezing of gait (FoG) is a common motor impairment that occurs as Parkinson's disease patients enter the moderate stage or higher, leading to a high risk of falls. Although previous methods have accurately identified FoG, significant challenges remain in predicting it. These challenges include difficulties in labeling Pre-FoG due to its personalization, sudden onset, and variability; the imbalance between the amount of FoG and normal gait data; and inadequate feature representation by the model. To address these challenges, we introduce a deep learning-based method for FoG prediction, named FoG-M3 (Mixup, MoCo, and MU-Net). This method employs a non-fixed length for Pre-FoG rather than a fixed length, allowing for more accurate labeling. To address the long-tail issue in the dataset, we integrated FoG-Mix with U-Net and the Mamba module. Additionally, the FoG-MoCo contrastive learning strategy was applied to enhance the model's representational capacity. The overall prediction accuracy reaches 95% on the Daphnet dataset and 93% on the BHXC dataset. Pre-FoG prediction accuracy also achieves approximately 90% on both datasets, surpassing the performance of FoG-Net, ResNeXt, and contrastive learning-based ResNet. Using the proposed method, we can predict FoG occurrences with enough time for posture adjustments, approximately 6 seconds before onset, which is more than typically available to Parkinson's disease patients. Therefore, the FoG-M3 method can predict Pre-FoG with high accuracy and efficiency, demonstrating substantial potential for use in Parkinson's disease rehabilitation.
- Top Cited PapersOpen Access
- 3 July 2025
- Published by BON VIEW PUBLISHING PTE in Smart Wearable Technology
- Vol. 1, A7
Synchronized Measurement of Electromechanical Responses of Fabric Strain Sensors Under Large Deformation
Fabric-based strain sensors hold significant potential across various applications, including sports, healthcare, rehabilitation, etc. Nonetheless, their complex performance under large deformation and varying loading rates, arising from material viscoelasticity and textile structure intricacies, remains inadequately understood. The primary constraint in evaluating their performance lies in the absence of electromechanically coupled instrumentation. This paper endeavors to overcome the limitation by developing a synchronized measurement system, which integrates mechanically controlled loading, voltage divider circuits, and visual measurement technologies. This system enables synchronized acquisition of mechanical and electrical signals spanning from 0.01 mm/min to 6 m/s, by employing material testing machines for low-speed loading and split Hopkinson pressure bars for medium-to-high-speed loading, and combining electrical performance measurements with displacement and strain field analyses. Experiments revealed that sensor sensitivity increased linearly with the logarithm of loading rates, while deformation patterns evolved with loading speed, thereby offering valuable insights into design and calibration of fabric-based strain sensors under dynamic conditions. Received: 27 April 2025 | Revised: 11 June 2025 | Accepted: 26 June 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data are available on request from the corresponding author upon reasonable request. Author Contribution Statement Bao Yang: Conceptualization, Methodology, Formal analysis, Resources, Writing – original draft, Writing – review & editing, Supervision, Project administration, Funding acquisition. Xianyu Zhu: Software, Formal analysis, Data curation, Writing – original draft. Chang Peng: Software, Validation, Formal analysis, Investigation, Data curation, Visualization. Licheng Zhou: Conceptualization, Methodology, Resources, Writing – review & editing, Supervision, Funding acquisition. Fei Wang: Conceptualization, Methodology, Resources, Writing – original draft, Writing – review & editing, Supervision, Funding acquisition. Zejia Liu: Conceptualization, Methodology, Resources, Supervision, Project administration, Funding acquisition. Liqun Tang: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Zhenyu Jiang: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Yiping Liu: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Senxin Chen: Software, Validation, Investigation.
- 3 July 2025
- Published by BON VIEW PUBLISHING PTE in Smart Wearable Technology
- Vol. 1, A7
Top Cited PapersOpen AccessSynchronized Measurement of Electromechanical Responses of Fabric Strain Sensors Under Large Deformation
Fabric-based strain sensors hold significant potential across various applications, including sports, healthcare, rehabilitation, etc. Nonetheless, their complex performance under large deformation and varying loading rates, arising from material viscoelasticity and textile structure intricacies, remains inadequately understood. The primary constraint in evaluating their performance lies in the absence of electromechanically coupled instrumentation. This paper endeavors to overcome the limitation by developing a synchronized measurement system, which integrates mechanically controlled loading, voltage divider circuits, and visual measurement technologies. This system enables synchronized acquisition of mechanical and electrical signals spanning from 0.01 mm/min to 6 m/s, by employing material testing machines for low-speed loading and split Hopkinson pressure bars for medium-to-high-speed loading, and combining electrical performance measurements with displacement and strain field analyses. Experiments revealed that sensor sensitivity increased linearly with the logarithm of loading rates, while deformation patterns evolved with loading speed, thereby offering valuable insights into design and calibration of fabric-based strain sensors under dynamic conditions. Received: 27 April 2025 | Revised: 11 June 2025 | Accepted: 26 June 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data are available on request from the corresponding author upon reasonable request. Author Contribution Statement Bao Yang: Conceptualization, Methodology, Formal analysis, Resources, Writing – original draft, Writing – review & editing, Supervision, Project administration, Funding acquisition. Xianyu Zhu: Software, Formal analysis, Data curation, Writing – original draft. Chang Peng: Software, Validation, Formal analysis, Investigation, Data curation, Visualization. Licheng Zhou: Conceptualization, Methodology, Resources, Writing – review & editing, Supervision, Funding acquisition. Fei Wang: Conceptualization, Methodology, Resources, Writing – original draft, Writing – review & editing, Supervision, Funding acquisition. Zejia Liu: Conceptualization, Methodology, Resources, Supervision, Project administration, Funding acquisition. Liqun Tang: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Zhenyu Jiang: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Yiping Liu: Conceptualization, Methodology, Resources, Supervision, Funding acquisition. Senxin Chen: Software, Validation, Investigation.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 24 (9) , 2739-2743
Design Method of Dual-Band High-Temperature Streamlined Radomes Accelerated by Artificial Intelligence
Streamlined radomes of hypersonic vehicles require electromagnetic (EM) transparency, as well as thermomechanical resistance. Current design methods for high-temperature streamlined radomes are limited to single-frequency designs. This letter presents a design approach for streamlined radomes that achieve dual-band EM transparency within the 4–40GHz range, along with thermomechanical resistance. The design employs a nine-layer silicon nitride ceramic graded dielectric multilayered wall. The realistic non-uniform temperature boundary plays a crucial role, which provides a sufficiently large design space for optimizing EM performance. The designed radomes possess an average insertion loss (IL) of less than 1.00 dB along with a low boresight error (BSE). It is worth noting that the artificial intelligence algorithm accelerates the optimization process by 13 times, making the design more efficient.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 24 (9) , 2739-2743
Design Method of Dual-Band High-Temperature Streamlined Radomes Accelerated by Artificial Intelligence
Streamlined radomes of hypersonic vehicles require electromagnetic (EM) transparency, as well as thermomechanical resistance. Current design methods for high-temperature streamlined radomes are limited to single-frequency designs. This letter presents a design approach for streamlined radomes that achieve dual-band EM transparency within the 4–40GHz range, along with thermomechanical resistance. The design employs a nine-layer silicon nitride ceramic graded dielectric multilayered wall. The realistic non-uniform temperature boundary plays a crucial role, which provides a sufficiently large design space for optimizing EM performance. The designed radomes possess an average insertion loss (IL) of less than 1.00 dB along with a low boresight error (BSE). It is worth noting that the artificial intelligence algorithm accelerates the optimization process by 13 times, making the design more efficient.
- 28 March 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Computational Materials Science and Engineering
- Vol. 15 (04)
Effect of subway speed and track irregularities on the fatigue life of e-type fastening clip under vehicle–track coupling dynamics
Vehicle–track coupling vibrations, primarily induced by track irregularities and vehicle speed, have a profound influence on the service life of fastening systems. However, the failure mechanism and damage evolution of elastic fasteners under such vibration coupling have remained elusive. In this research, tensile tests on 60Si2Mn steel and quasi-static as well as fatigue tests on e-type clips were conducted. A finite element model of the fastening system and a vehicle–track coupling dynamics model for a metro vehicle were developed to conduct a comprehensive analysis of the fatigue life of the e-type clip, considering the combined effects of track irregularity, vehicle speed and initial clamping force. Additionally, a modified mean stress correction model was employed to predict the clip’s fatigue life, and a novel two-parameter nonlinear fatigue cumulative damage model was proposed to describe the clip’s damage evolution. These innovative approaches and models provide valuable insights for guiding the installation and maintenance of track infrastructure.
- 28 March 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Computational Materials Science and Engineering
- Vol. 15 (04)
Effect of subway speed and track irregularities on the fatigue life of e-type fastening clip under vehicle–track coupling dynamics
Vehicle–track coupling vibrations, primarily induced by track irregularities and vehicle speed, have a profound influence on the service life of fastening systems. However, the failure mechanism and damage evolution of elastic fasteners under such vibration coupling have remained elusive. In this research, tensile tests on 60Si2Mn steel and quasi-static as well as fatigue tests on e-type clips were conducted. A finite element model of the fastening system and a vehicle–track coupling dynamics model for a metro vehicle were developed to conduct a comprehensive analysis of the fatigue life of the e-type clip, considering the combined effects of track irregularity, vehicle speed and initial clamping force. Additionally, a modified mean stress correction model was employed to predict the clip’s fatigue life, and a novel two-parameter nonlinear fatigue cumulative damage model was proposed to describe the clip’s damage evolution. These innovative approaches and models provide valuable insights for guiding the installation and maintenance of track infrastructure.