LTLiqun Tang

Liqun Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Liqun Tang has a total of 141 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A statistical damage model for coupled mechano-electrophysiological axonal injury

    by Zexuan Chen, Liqun Tang, Bao Yang, Yiping Liu, Zhenyu Jiang, Licheng Zhou, Zejia Liu

    Deformation-induced injury of white matter nerve bundles is prevalent in central nervous system injuries, leading to a series of neurological dysfunctions. To describe the effect of deformation injury on the physiological electrical signals of neurons, several axonal electrophysiological damage models based on the Hodgkin-Huxley equations have been proposed. However, none of these models can fully characterize the results of white matter nerve stretching experiments under different rates and amplitudes. Building on previous work by peers, we propose a novel axonal deformation damage model that comprehensively considers the coupled effects of sodium and potassium channel damage on gating variable rate constants, as well as the differences in mechanical properties and injury among individual axons during deformation—with these differences continuously modeled by a statistical distribution. The proposed model can not only reasonably describe the sodium left-shift phenomenon (a key post-injury feature) but also accurately reproduce the neuro-electrophysiological responses of nerve fascicles under various stretching conditions. This new neuro-electrophysiological model for nerve fascicle injury exhibits good universality and provides a mechanical mechanism-based reference for future clinical treatment strategies of nerve injury.

  • Open Access

    Impact testing system for an anthropomorphic craniocerebral model with enhanced mechanical fidelity

    by Jingyu Wang, Yuting Zhang, Rui Li, Kai He, Zexuan Chen, Haoqiang Ren, Zuyue Lei, Licheng Zhou, Zejia Liu, Yiping Liu, et al.

  • Open Access

    High-Performance Riveted Complementary-Structure Rotating Triboelectric Nanogenerator for Energy Harvesting from Slow-Speed Water Flows

    by Bao Yang, Chang Peng, Zihao Wang, Fuwang Zhao, Licheng Zhou, Zhenyu Jiang, Yiping Liu, Liqun Tang, Zejia Liu, Jinli Piao

    Triboelectric nanogenerators (TENGs) are promising for harvesting low-frequency mechanical energy, but rotating TENGs (R-TENGs) driven by low-speed water flow remain constrained by limited driving torque, sliding-contact losses, and rotating-system stability. Here, a three-dimensional (3D) riveted complementary-structure rotating triboelectric nanogenerator (RCSR-TENG) is proposed for low-speed water-flow energy harvesting. A semi-analytical formulation incorporating a force-dependent real-contact fraction is developed to describe the coupled relationships among output voltage, transferred charge, rotation angle, and contact force. Because the contact parameters were not independently calibrated, the formulation is used for sensitivity and trend analysis rather than as a quantitatively validated predictive model. For the single prototype tested for each configuration, at 1000 rpm under the fixed effective measurement load of 9 MΩ, the RCSR-TENG produced a peak output power of 544 μW, compared with 304 μW for the flat R-TENG, representing an increase of approximately 79%. The same RCSR-TENG prototype maintained a stable voltage amplitude of over 150,000 rotation cycles. When coupled to a fully passive flapping-foil collector in a 0.55 m s−1 water flow, the system generated periodic electrical output with a peak area-normalized power exceeding 5000 μW m−2. These results demonstrate the structural-performance advantage of the riveted complementary design and its proof-of-concept applicability to low-speed water-flow energy harvesting.

  • Open Access

    OpenCorr GUI: A free software for accurate and robust deformation measurement of digital image correlation and digital volume correlation

    by Rui Li, Kai He, Haoqiang Ren, Hongli Wang, Yajing Zhang, Chang Peng, Yifei Zhou, Taolin Sun, Liqun Tang, Zhenyu Jiang

    Open-source and free software for digital image correlation (DIC) and digital volume correlation (DVC) have experienced rapid growth in recent years. However, the function, availability, and measurement capability of existing DIC/DVC freeware remain insufficient to well support scientific research and engineering applications. This paper demonstrates OpenCorr GUI (version 3), a standalone software developed based on OpenCorr library, which provides full functions for deformation measurements using 2D-DIC, Stereo-DIC, and DVC, as well as friendly graphical user interface (GUI) for parameter configuration and result visualization. Furthermore, a regional fitting strategy is proposed and integrated into the software to significantly improve the ability of DIC/DVC in measurement of complex large deformation. The software provides a specific approach of strain calculation for Stereo-DIC, which is not included or correctly implemented in most of existing DIC freeware. The functions of OpenCorr GUI are demonstrated through simulated and real experimental cases, including large tensile deformation in 2D-DIC, inhomogeneous compressive deformation in DVC, reconstruction of complex surface topography and strain measurement on the curved surface of an inflated balloon in Stereo-DIC. The results show that the software delivers accurate and robust measurements, while offering comprehensive features and good user experience.

  • Performance assessment for bridge structures based on structural health monitoring data and exponential patch model

    by Qingkai Xiao, Ruilan Tian, Licheng Zhou, Yiping Liu, Xiaolong Zhang, Qiang Xue, Liqun Tang

  • High performance flow-restricted plate sensor with bidirectional sensing ability for smart wearable respiratory monitoring

    by Jianhui Chen, Chang Peng, Bao Yang, Licheng Zhou, Zhenyu Jiang, Zejia Liu, Yiping Liu, Liqun Tang

    Respiratory diseases have become one of the most prevalent health conditions worldwide. Respiration contains rich physiological and pathological information and smart respiratory monitoring holds numerous promising applications in the fields of medical healthcare, sports, and general wellness. However, existing respiratory monitoring systems are still limited by insufficient accuracy, bulky configurations, and poor wearing comfort. In this study, we developed a novel miniature flow-restricted plate respiratory sensor with bidirectional sensing ability and high sensitivity for quantitative respiratory monitoring. Theoretical models and numerical simulations were developed and utilized to guide the structural design. After structural optimization, the sensor achieves a favorable balance between pressure sensitivity and respiratory resistance. A calibration system was also developed based on multiple piston devices, stepper motors, a camera, and digital image correlation for displacement monitoring. This calibration system can generate both constant and variable airflow to simulate human respiration. Average accuracies of the sensor in terms of ventilation and airflow velocity reach up to 97% under controlled calibration conditions in laboratory settings. A design framework for integrating the proposed sensor into a lightweight and wearable respiratory monitoring platform is established. Multiple scenarios including resting postures, running, and cycling demonstrate the feasibility of this lightweight and wearable respiratory monitoring approach.

  • A General Kinematic Brain Injury Criterion Combining Translational and Rotational Effects

    by Yuting Zhang, Da Teng, Zexuan Chen, Bao Yang, Zhenyu Jiang, Yiping Liu, Zejia Liu, Licheng Zhou, Liqun Tang

    Purpose The human brain typically experiences both translational and rotational motions during impact. Existing kinematic brain injury criteria often consider only one of these effects, or lack a reasonable combination of both, which may lead to significant misjudgments. This study proposes a general injury criterion (GIC) that uses the widely accepted injury criterion of maximum principal strain (MPS) as an intermediary variable and comprehensively accounts for both translational and rotational effects. Methods A total of 178 head impact cases were established, considering different impact types, locations, directions, and velocities. Corresponding finite element models were constructed based on the THUMS model. The translational and rotational effects were quantitatively analyzed. Using MPS as an intermediate variable, the GIC was carefully developed and compared with existing injury criteria. On this basis, an application demonstration was performed by combining simulation results with clinical outcomes from existing literature. Results The quantitative analysis results of translational and rotational effects show that their contributions to the MPS are often comparable, and their effects on brain injury need to be considered simultaneously. GIC, combining the translational and rotational effects, has the highest linear correlation with MPS. It shows a 17% higher linear correlation than the second-best criterion. In addition, for 24 clinically diagnosed TBI cases, the classification accuracy of GIC reaches 58 and 92% when the MPS injury thresholds are set at 0.2 and 0.35, respectively. Conclusion The proposed GIC achieves the highest goodness of fit with MPS among the kinematic criteria evaluated in this study and demonstrates the feasibility of predicting traumatic brain injury with case studies of impacts. It provides a practical tool for rapid kinematics–based brain injury assessment in bioengineering and safety engineering.

  • An interactive multi-task learning model for multi-channel strain data reconstruction in SHM

    by Xuhao Huang, Zejia Liu, Yonghui Lu, Bao Yang, Licheng Zhou, Zhenyu Jiang, Yiping Liu, Liqun Tang


  • Open Access

    Recent Advances in Triboelectric Materials for Active Health Applications

    by Chang Peng, Yuetong Lin, Zhenyu Jiang, Yiping Liu, Licheng Zhou, Zejia Liu, Liqun Tang, Bao Yang

    Triboelectric materials can convert irregular mechanical stimuli from human motion or environmental sources into high surface charge densities and instantaneous electrical outputs. Their intrinsic properties, such as flexibility, stretchability, chemical tunability, and compatibility with diverse substrates, play a critical role in determining the efficiency and reliability of triboelectric devices. In the context of active health, triboelectric materials not only serve as the core functional layers for self-powered sensing but also enable real-time physiological monitoring, motion tracking, and human–machine interaction by directly transducing biomechanical signals into electrical information. Soft triboelectric sensors exhibit high sensitivity, wide operational ranges, excellent biocompatibility, and wearability, making them highly promising for active health monitoring applications. Despite these advantages, challenges remain in enhancing surface charge density, achieving effective signal multiplexing, and ensuring long-term stability. This review provides a comprehensive overview of triboelectric mechanisms, working modes, influencing factors, performance enhancement strategies, and wearable health applications. Finally, it systematically summarizes the key improvement approaches and future development directions of triboelectric materials for active health, offering valuable guidance for advancing wearable self-powered biosensors.


  • A 3D-Voronoi-based hydrogel polymer network model and its application in verifying the effectiveness of hyperelastic models

    by Xinyuan Wang, Min Yang, Ping Ni, Liqun Tang, Yiping Liu, Zejia Liu, Zhenyu Jiang, Licheng Zhou, Bao Yang