Wei Cao
Wei Cao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Bin Du
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
3 shared publications - Dong Chen
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Feng Huang
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, P. R. China
1 shared publication - Jianjie Xu
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Jianjie Xu
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Lei Guo
State Key Laboratory of NBC Protection for Civilian Research, Beijing 102205, China
1 shared publication
Latest Publications
- Open Access
- 14 February 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (2) , 137
Investigation of the Colorimetric Characteristics of VX in Squaraine-Based Solutions
Colorimetry is an important on-site detection method for organophosphorus compounds. O-Ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) is recognized as one of the deadliest organophosphorus chemical agents, and the rapid on-site detection of VX is of great significance to public safety. In this paper, a squaraine derivative was synthesized as probe molecules, and the sensing characteristics of VX in a colorimetric solution system containing tetrabutylammonium fluoride (TABF) were studied with UV−Vis spectroscopy, nuclear magnetic resonance (1H NMR), and mass spectrometry. The results showed that the binding of the thiol moiety of VX to the quaternary ring of the squaraine probe changed the molecular conjugation system, and that the rapid colorimetric detection of micro-trace VX was achieved based on color change before and after interaction with squaraine, enabling the detection limit of VX to be as low as 0.4 μg/mL. Moreover, the colorimetry method also possessed satisfactory sensitivity and could detect VX from other organophosphorus pesticides (e.g., parathion and dichlorvos), phosphorus-containing reagents (e.g., diethyl chlorophosphate and dimethyl methylphosphonate), a benzene series (e.g., toluene), and acid and base agents (e.g., acetic acid and triethylamine, respectively), which demonstrated that squaraine-based colorimetry could provide fast, on-site measurement results for VX detection. The strategy of this research could be extended as a common approach for the detection of other organophosphorus nerve agents or organophosphorus pesticides.
- 14 February 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (2) , 137
Open AccessInvestigation of the Colorimetric Characteristics of VX in Squaraine-Based Solutions
Colorimetry is an important on-site detection method for organophosphorus compounds. O-Ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) is recognized as one of the deadliest organophosphorus chemical agents, and the rapid on-site detection of VX is of great significance to public safety. In this paper, a squaraine derivative was synthesized as probe molecules, and the sensing characteristics of VX in a colorimetric solution system containing tetrabutylammonium fluoride (TABF) were studied with UV−Vis spectroscopy, nuclear magnetic resonance (1H NMR), and mass spectrometry. The results showed that the binding of the thiol moiety of VX to the quaternary ring of the squaraine probe changed the molecular conjugation system, and that the rapid colorimetric detection of micro-trace VX was achieved based on color change before and after interaction with squaraine, enabling the detection limit of VX to be as low as 0.4 μg/mL. Moreover, the colorimetry method also possessed satisfactory sensitivity and could detect VX from other organophosphorus pesticides (e.g., parathion and dichlorvos), phosphorus-containing reagents (e.g., diethyl chlorophosphate and dimethyl methylphosphonate), a benzene series (e.g., toluene), and acid and base agents (e.g., acetic acid and triethylamine, respectively), which demonstrated that squaraine-based colorimetry could provide fast, on-site measurement results for VX detection. The strategy of this research could be extended as a common approach for the detection of other organophosphorus nerve agents or organophosphorus pesticides.
- Open Access
Hydrothermal Synthesis and Microwave Absorption Properties of Nickel Ferrite/Multiwalled Carbon Nanotubes Composites
It is well accepted that the microwave absorption performance of ferrite can be enhanced via the hybridization. However, it is still very challenging to design the hierarchical nanostructure of ferrite hybrids to fabricate wave absorbing composites with both the high efficiency and lightweight. Herein, we successfully realize the in-situ synthesis of nickel ferrite/multiwalled carbon nanotubes (NiFe2O4/MWCNTs) hybrids with a large-scale production by the hydrothermal method. The structural characteristics, morphology, electromagnetic and microwave absorption properties were analyzed by X-ray diffraction, scanning electron microscope and vector network analyzer. The morphological study shows that NiFe2O4 nanoparticles with a small size (tens of nanometers) are coated on the MWCNTs, leading to a three-dimensional hierarchical nanostructure. The NiFe2O4/MWCNTs hybrids show satisfied microwave absorption properties. Typically, the optimized sample shows the minimum reflection loss of −19 dB at 11.3 GHz, and the bandwidth of the reflectivity below −10 dB is 2.5 GHz with a thin thickness of 1.5 mm. This result shall be due to the improved dielectric losses or interface polarization etc. Our results demonstrate a facile approach for the design of ferrite-based microwave absorber to meet the requirements of lightweight, thin-thickness and high efficiency.
Open AccessHydrothermal Synthesis and Microwave Absorption Properties of Nickel Ferrite/Multiwalled Carbon Nanotubes Composites
It is well accepted that the microwave absorption performance of ferrite can be enhanced via the hybridization. However, it is still very challenging to design the hierarchical nanostructure of ferrite hybrids to fabricate wave absorbing composites with both the high efficiency and lightweight. Herein, we successfully realize the in-situ synthesis of nickel ferrite/multiwalled carbon nanotubes (NiFe2O4/MWCNTs) hybrids with a large-scale production by the hydrothermal method. The structural characteristics, morphology, electromagnetic and microwave absorption properties were analyzed by X-ray diffraction, scanning electron microscope and vector network analyzer. The morphological study shows that NiFe2O4 nanoparticles with a small size (tens of nanometers) are coated on the MWCNTs, leading to a three-dimensional hierarchical nanostructure. The NiFe2O4/MWCNTs hybrids show satisfied microwave absorption properties. Typically, the optimized sample shows the minimum reflection loss of −19 dB at 11.3 GHz, and the bandwidth of the reflectivity below −10 dB is 2.5 GHz with a thin thickness of 1.5 mm. This result shall be due to the improved dielectric losses or interface polarization etc. Our results demonstrate a facile approach for the design of ferrite-based microwave absorber to meet the requirements of lightweight, thin-thickness and high efficiency.
- Open Access
A Potassium Ion-Exchanged Glass Optical Waveguide Sensor Locally Coated with a Crystal Violet-SiO2 Gel Film for Real-Time Detection of Organophosphorus Pesticides Simulant
An optical waveguide (OWG) sensor was developed for real-time detection of diethyl chlorophosphate (DCP) vapor, which is a typical simulant for organophosphorus pesticides and chemical weapon agents. Silica gel, crystal violet (CV), and potassium ion-exchange (PIE) OWG were used to fabricate the sensor’s device. In the real-time detection of the DCP vapor, the volume fraction of DCP vapor was recorded to be as low as 1.68 × 10−9. Moreover, the detection mechanism of CV-SiO2 gel film coated the PIE OWG sensor for DCP, which was evaluated by absorption spectra. These results demonstrated that the change of output light intensity of the OWG sensor significantly increased with the augment of the DCP concentration. Repeatability as well as selectivity of the sensors were tested using 0.042 × 10−6 and 26.32 × 10−6 volume fraction of the DCP vapor. No clear interference with the DCP detection was observed in the presence of other common solvents (e.g., acetone, methanol, dichloromethane, dimethylsulfoxide, and tetrahydrofuran), benzene series (e.g., benzene, toluene, chlorobenzene, and aniline), phosphorus-containing reagents (e.g., dimethyl methylphosphonate and trimethyl phosphate), acid, and basic gas (e.g., acetic acid and 25% ammonium hydroxide), which demonstrates that the OWG sensor could provide real-time, fast, and accurate measurement results for the detection of DCP.
Open AccessA Potassium Ion-Exchanged Glass Optical Waveguide Sensor Locally Coated with a Crystal Violet-SiO2 Gel Film for Real-Time Detection of Organophosphorus Pesticides Simulant
An optical waveguide (OWG) sensor was developed for real-time detection of diethyl chlorophosphate (DCP) vapor, which is a typical simulant for organophosphorus pesticides and chemical weapon agents. Silica gel, crystal violet (CV), and potassium ion-exchange (PIE) OWG were used to fabricate the sensor’s device. In the real-time detection of the DCP vapor, the volume fraction of DCP vapor was recorded to be as low as 1.68 × 10−9. Moreover, the detection mechanism of CV-SiO2 gel film coated the PIE OWG sensor for DCP, which was evaluated by absorption spectra. These results demonstrated that the change of output light intensity of the OWG sensor significantly increased with the augment of the DCP concentration. Repeatability as well as selectivity of the sensors were tested using 0.042 × 10−6 and 26.32 × 10−6 volume fraction of the DCP vapor. No clear interference with the DCP detection was observed in the presence of other common solvents (e.g., acetone, methanol, dichloromethane, dimethylsulfoxide, and tetrahydrofuran), benzene series (e.g., benzene, toluene, chlorobenzene, and aniline), phosphorus-containing reagents (e.g., dimethyl methylphosphonate and trimethyl phosphate), acid, and basic gas (e.g., acetic acid and 25% ammonium hydroxide), which demonstrates that the OWG sensor could provide real-time, fast, and accurate measurement results for the detection of DCP.