AMAndoni Moral

Andoni Moral

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Research Subjects


Andoni Moral has a total of 263 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Progress in Resource Evaluation Using a Handheld Raman Instrument Developed for Astronaut Missions

    by J. G. T. Armstrong, M. McHugh, J. Parnell, H. N. Lerman, A. Moral, I. B. Hutchinson

    Raman spectroscopy is being developed for resource evaluation on planetary surfaces, especially on the Moon. Analogue studies were undertaken to collect data that would indicate the presence of water and help develop the technology to search for valuable trace elements. Analysis of a gabbro‐anorthosite suite by Raman spectroscopy distinguished pyroxene, olivine and feldspar in samples whose mineralogy had been cross‐checked by electron microscopy. Examination of the olivine by electron microscopy showed a complex distribution of hydrated alteration products referable as serpentine or iddingsite. The altered olivine is thus a proxy for water. Raman spectroscopy of similar olivine produced a map of alteration products, which is a first depiction of a map of hydration. A targeted set of trace elements was more abundant in the feldspar. Raman spectroscopy of feldspar in cross‐cutting pegmatite veins detected a range of minerals containing trace elements, including anomalous amounts of the critical elements lithium and caesium. Measurement of Li and Cs in hot spring deposits which lie on the gabbro‐anorthosite suite shows much higher enrichment in shale sediments, which Raman spectroscopy identified as muscovite. This conclusion is consistent with the concentration of some trace elements (including Li) in detrital minerals and other trace elements (including Cs) in fluid precipitates.


  • Determine the Elemental Composition of Minerals From Complex Solid‐Solution Series by Raman Spectroscopy: Implications for Mars Exploration Missions

    by Sofia Julve‐Gonzalez, Jose Antonio Manrique, Marco Veneranda, Pilar Renedo, Paula Xiaozhen Vega, Iván Reyes‐Rodríguez, María Mayoral, Sergio Jiménez, Lidia Asenjo, Aurelio Sanz‐Arranz, et al.

    Garnets are minerals offering valuable insights into geological and planetary processes, in both terrestrial and extraterrestrial contexts. Their presence in metamorphic rocks, as well as in meteorites, makes them key indicators of the conditions under which they formed, such as pressure, temperature, and chemical environment. This information is valuable for understanding the history and evolution of planetary bodies, including Earth and Mars. Developing automatic classification models for garnets using Raman spectroscopy has a potential application for planetary exploration, particularly for the Raman Laser Spectrometer (RLS) on the Rosalind Franklin rover of the upcoming ExoMars mission. In this work, we used a dataset combining spectra from ADAMM and RRUFF databases, ensuring a well‐distributed representation of the two main garnet groups: pyralspites and ugrandites. The spectra from ADAMM were obtained using the RLS SIM, a laboratory version of RLS, while RRUFF data helped increase the number of samples in the dataset. After standardizing all data, we designed a two‐step classification model: a top‐level model to classify into the two main groups and two specific models to classify the garnet type within each group. We tested multiple machine learning algorithms, including support vector machine (SVM), k‐nearest neighbors (KNN), artificial neural networks (ANN), decision tree, and naive Bayes. The top‐level classification reached 100% accuracy in testing, while the final combined model achieved 80.42% accuracy. These results demonstrate that machine learning and Raman spectroscopy can effectively classify garnets, providing a valuable tool for planetary missions and mineralogical studies.


  • Open Access

    The Reference Setup for the RAX Raman Spectrometer on the MMX IDEFIX Rover for Phobos in-situ analysis

    by Nicolai Krybus, Fabian Seel, Susanne Schröder, Maximilian Buder, Yuri Bunduki, Till Hagelschuer, Henri Eisenmenger, Jan Binger, Enrico Dietz, Emanuel Kopp, et al.

    Introduction: In late 2026, JAXA will launch the Martian Moons eXploration mission (MMX) towards the Mars system to gain insights into the origin of the two Martian moons, Phobos and Deimos. After a travel time of about a year and another year of observations from orbit, the spacecraft will approach Phobos where it deploys the rover IDEFIX to the moon’s surface to take in-situ measurements. Moreover, the main spacecraft will gather samples (

  • Open Access

    Developing Continuous-Wave Laser Systems for Raman Spectroscopy: Overcoming Significant Challenges

    by Marina Benito-Parejo, Pablo Rodríguez Pérez, Guillermo Lopez Comazzi, Andoni Moral Inza, Tomás Belenguer Dávila

    In 2018, the flight model of the Raman Laser Spectrometer (RLS) instrument for the ExoMars mission was delivered [1]. Among the critical parts of the RLS instrument was its laser unit, an INTA-led development and one of the most demanding units to comply with the technical and scientific performances required by the mission [2]. To ensure stable and robust operation in the Mars environment, the laser unit had to meet strict optical, thermal and mechanical criteria. This required an extremely precise alignment and integration process with very tight tolerances [3],[4].The achievement of this milestone and the experience gained at RLS led to INTA's collaboration in JAXA's Martian Moons eXploration (MMX) project. DLR, INTA/University of Valladolid and the University of Tokyo collaborated to create the RAX instrument (Raman Spectrometer for MMX), which is part of this mission. The MMX rover, tasked with investigating the Martian moon Phobos, will carry the RAX instrument. The laser flight model created specifically for RAX was delivered and successfully completed all qualification phases required for its space deployment in 2022 [5].These consecutive advancements in two consecutive planetary missions provided INTA with a solid technological foundation and an unmatched practical understanding of the capabilities and limitations of space-qualified laser systems. During the development of these projects, the difficulties of using solid-state lasers (DPSS) with second-harmonic generators (SHG) to achieve continuous green beam became evident. Although these systems offer very high beam quality and spectral efficiency, they present significant drawbacks in terms of mechanical integration and optical alignment, particularly when it comes to minimizing dimensions and mass while maintaining stable optical performance in space environments.INTA launched ProtoRaman, a strategic research initiative that includes a line to investigate and validate alternative laser architectures, both continuous and pulsed, for space applications. Focusing on continuous emission lasers, and in order to overcome the drawbacks encountered in RLS and RAX, we are designing and evaluating the feasibility of working with a new generation of green lasers for proximity Raman spectroscopy that are reliable, compact and easy to integrate. The development of continuous wave (CW) green lasers based on visible emission gallium nitride (GaN) diode lasers [6], together with external cavity structures, is one of the main objectives of this INTA-funded project, which covers multiple research areas. By using visible-emitting diodes instead of nonlinear frequency-conversion elements, the chosen configuration aims to significantly simplify the laser head. However, this strategy entails the creation of external cavity feedback mechanisms that enable spectral narrowing, wavelength stabilization, and moderate power enhancement [7] to meet the demanding specifications of planetary proximity Raman spectroscopy, which include narrow linewidths, low optical noise, and spectral stability.Finding enough optical power in the 515–525 nm range while preserving the beam characteristics necessary for efficient Raman excitation is one of the major challenges facing this strategy. Furthermore, since edge-emitting GaN diodes lack intrinsic mode selection, not only appropriate cavity geometries and optical coatings are needed, but also highly precise optical alignment and thermal control are required to maintain spectral purity and linewidth control. Furthermore, the overall system must be designed to withstand environmental stresses such as vibration, thermal cycling, and extended operation in low-pressure or vacuum environments. This work focuses on proof-of-concept implementations following theoretical modeling and basic design phases. These have revealed significant limitations related to the alignment sensitivity of the external cavity design, as well as the effects of mechanical tolerances and thermal drift on spectral linewidth and power stability. An extensive testing campaign is currently underway to evaluate the limitation ranges and the margins achieved by optical performance. These impacts will then be assessed in representative environments. Keywords: Laser, Raman Spectroscopy, RLS, MMX, Planetary Exploration References [1] Rull, F. et al., “The Raman Laser Spectrometer for the ExoMars Rover Mission to Mars”., Astrobiology, 17 (6-7): 627-654. (2017)[2] Rull, F. et al., "The Raman Laser Spectrometer for the ExoMars Mission: Overview and Expected Performance," Spectrochimica Acta Part A, 2020.[3] Ribes-Pleguezuelo, P. et al. “Assembly processes comparison for a miniaturized laser used for the Exomaras European Space Agency mission” Optical Engineering 55 (11), 116107 (2016)[4] Pérez-Canora, C. et al., "Development and Integration of the RLS Laser Unit for ExoMars," Proceedings of the European Planetary Science Congress, 2018.[5] Bibring, J.-P. et al., “The RAX Raman Spectrometer for MMX: Scientific Goals and System Design,” International Journal of Astrobiology, 2022.[6] Nakamura, S. et al., "Visible-Light Emitting GaN Laser Diodes: Recent Developments and Future Perspectives," Nature Photonics (2013)[7] M. Chi et al. “Green high-power tunable external-cavity GaN diode laser at 515nm”. Optics Letters 41 (18), 4154-4157 (2016)

  • Enhancing Operational Efficiency of the Raman Laser Spectrometer (RLS) in the ExoMars Rosalind Franklin Mission: A Comprehensive Qualitative Analysis of Key Parameters in the Sample Acquisition and Measurement Strategies

    by C. P. Canora, Andoni G. Moral Inza, Laura Seoane Purriños, Jesús Zafra Iglesias, Pablo Rodríguez Pérez, Marina Benito‐Parejo, J. A. Rodríguez, Rosario Canchal, Pilar Santamaría, Iván López, et al.

    The Raman Laser Spectrometer (RLS), part of the Pasteur analytical suite onboard the ExoMars 2028 Rosalind Franklin rover, is designed to perform structural and compositional analyses of powdered subsurface samples on Mars. Its fully autonomous operation within the constraints of the Pasteur Analytical Laboratory‐limited by time, energy, and sample availability‐requires an efficient balance between scientific performance and operational viability. This study presents a qualitative analysis of RLS operations under mission‐representative conditions using the Flight Spare (FS) model, focusing on the impact of key parameters‐number of accumulations, autofocus frequency, and analyzed spots per sample‐on the system's detection capabilities. Experimental campaigns were conducted using ESA‐selected analog samples representative of Oxia Planum geology. Performance was evaluated using both the RLS FS and the ExoMars Simulator. Results show high consistency (90‐95%) in mineral detection between systems, confirming the robustness of the RLS FS under representative scenarios. The instrument demonstrated its ability to identify key phases, including oxides, silicates, carbonates, hydrated sulfates, and amorphous carbon, highlighting its relevance to geological and astrobiological investigations. Operational tests confirmed that reducing the number of accumulations or autofocus activations‐under appropriate sample conditions‐does not compromise spectral quality. These findings support a flexible strategy that adapts operational parameters to the scientific context, optimizing resource use and preserving long‐term instrument reliability. The results will contribute to the refinement of nominal activity plans for ExoMars and reinforce the use of the RLS FS as a critical asset for validating future configurations of the flight model.


  • Novel Performances of a Combined Raman‐LIBS Instrument for Future Lunar Astronaut Exploration Program: The PHOENIX for PANGAEA Project

    by Andoni G. Moral, Carlos Pérez, Laura Seoane, Pablo Rodríguez‐Pérez, Iván López, Emma Losantos Guillén, Olga Prieto‐Ballesteros, Marina Benito Parejo, Jesús Zafra, J. A. Rodríguez, et al.

    Over the last decade, Raman spectroscopy has established itself as a fundamental technique for planetary exploration and the geological characterization of bodies in our Solar System. ESA has been evaluating combinations of analytical methods combined in a portable, handheld analytical tool for planetary surface exploration missions, with the potential use‐case being human missions to the surface of the Moon (e.g., in the frame of the NASA‐led Artemis program). Based on the Raman technique, we report on a development that seeks to complement Raman with other techniques for determining chemical composition, such as LIBS or XRF, and also provided with a close‐up imager integrated into the instruments to obtain context images of the analyzed samples, to determine their texture and help select the point of analysis. For this design, portability and ergonomic considerations are also being taken into account, since they must be operated by future astronauts quickly and efficiently. Breadboard instruments developed in the frame of an ESA contract are designed to interface wirelessly with an electronic field book and are usable not just in a laboratory environment but also as training equipment on Earth during the analogue field campaigns of its astronauts within the PANGAEA program. This work shows the performance obtained by one of the two Portable Handheld cOmbinEd RamaN‐LIBS‐XRF (PHOENIX) instruments developed within the framework of this ESA contract.


  • Open Access

    The Raman Spectrometer RAX on the MMX IDEFIX Rover for in-situ Mineralogical Analysis on Phobos

    by Susanne Schröder, Ute Böttger, Yuichiro Cho, Heinz-Wilhelm Hübers, Olga Prieto-Ballesteros, Fernando Rull, Maximilan Buder, Yuri Bunduki, Enrico Dietz, Till Hagelschuer, et al.

    A compact Raman spectrometer [1] was developed for in-situ science on Phobos with the IDEFIX rover [2], which will be launched as part of JAXA’s Martian Moon eXploration (MMX) mission in 2026. The MMX mission is dedicated to study the two Martian moons, Phobos and Deimos, with the aim of better understanding their origin and evolution [3, 4]. Orbital observations with the main MMX spacecraft and in-situ science on Phobos with the IDEFIX rover will be complemented by returning samples (>10 g) from the surface of Phobos back to Earth. The rover is expected to land between late 2028 and early 2029, in conjunction with the rehearsal for the first landing of the main spacecraft.Figure 1. left: RAX flight model (FM) during thermal vacuum testing at DLR. Right: RAX development model (DM) combined locomotion test with MMX demonstration rover in DLR testbed during a Raman measurement.The RAman spectrometer for MMX (RAX) contributes directly to the high level mission objectives by characterizing the mineral composition of the Phobos surface in-situ, providing ground truth. While different mineral phases can be associated with different formation scenarios (e.g. captured asteroid or major impact) and surface alteration processes on Phobos, the mineralogical information obtained with RAX can also help inform decisions about sampling with the main spacecraft and be compared with data obtained from the returned samples and in-situ data from the surface of Mars. The rover's mobility allows measurements to be taken from multiple positions along the rover's traverse, allowing local variations in composition to be studied. RAX measures down to the ground below the rover. RAX is extremely compact, with a mass of only 1.5 kg and a volume of about 1 dm³. The optical design of RAX was driven by 1) the tight volume and mass constraints available of the small MMX rover and 2) optimizing the collection and detection capabilities of the Raman signal from a sample at several centimeters distance below the rover’s body. Raman excitation (λ = 532 nm, typical optical power on sample 20 mW) is provided by a separate laser module based on the Raman Laser Spectrometer (RLS) laser developed for the Rosalind Franklin rover of the ExoMars mission [5]. The laser emission is transmitted to the RAX Spectrometer Module via a multimode optical fiber with a core diameter of 50 µm. To focus the laser on the Phobos surface below the rover, the spectrometer is equipped with an opto-mechanical autofocus subsystem. It allows fine-tuning of the focus position at a working distance of about 8 cm, within a range of 13 mm and an accuracy of 50 µm. The RAX instrument covers a spectral range of 535 to 680 nm, corresponding to a Raman shift of approximately 90 to 4000 cm−1 and therefore enabling the identification of water-bearing minerals. The spectral resolution across the entire spectral range is about 10 cm−1. To demonstrate the functionality of the RAX instrument after launch and to monitor its performance, a Verification Target (VT) is part of the payload. The VT is a 13 mm diameter pellet made of deuterated polyethylene terephthalate (PET) and was developed and space-qualified specifically for this mission [6]. The VT is placed in the field of view of the RAX instrument and can be measured during the cruise until the rover separates from the MMX spacecraft for landing on Phobos.For a Raman measurement on Phobos, the rover’s locomotion system is needed for the main height adjustment: the rover will gradually lower its body height until the RAX instrument is within its working range. After autofocusing, RAX will measure what is exposed beneath the rover from a footprint of 50 µm. Visual context is provided by the rover’s cameras. To improved data acquisition, Raman data will be collected during Phobos nights.Representing a collaborative effort, RAX is a joint contribution from the German Aerospace Center (DLR), Instituto Nacional de Técnica Aerospacial (INTA), and JAXA. Delivered to the MMX Phobos Rover in August 2022, the RAX flight model was successfully integrated into the IDEFIX rover in October 2022. The flight model of the rover has been delivered to JAXA/MELCO where it is currently being integrated into the main spacecraft for further qualification and functional testing. Operational sequences, e.g. defining the interaction between locomotion and science instruments, are currently being prepared. RAX scientific measurements are being prepared with laboratory studies using the RAX development model. AcknowledgementsMMX is a JAXA mission with contributions from NASA, CNES and DLR. The MMX IDEFIX rover is provided by CNES and DLR. The RAX instrument is a joint development from DLR-OS, INTA/UVa, and JAXA/UTo. The authors thank their respective national funding frameworks including DLR’s Programmatik Raumfahrt and PID2022-142490OB-C31 funded by MCIN/AEI/10.13039/501100011033 and are grateful to the MMX, IDEFIX rover and RAX instrument teams who made this work possible.References[1] T. Hagelschuer, U. Böttger, M. Buder et al., Internat. Astronautical Congress (IAC): 18-22 September, 2022, Proceed. 2022, IAC-22-A3.4A.8. [2] S. Ulamec, P. Michel, M. Grott et al., Acta Astronaut. 2023, 210, 95.[3] T. Usui, K. Bajo, W. Fujiya et al., Space Sci. Rev. 2020, 216, 49.[4] Y. Kawakatsu, K. Kuramoto, T. Usui et al., Acta Astronaut. 2023, 202, 715.[5] F. Rull, S. Maurice, I. Hutchinson et al., Astrobiology 2017, 17, 627.[6] A. G. Moral, J. Mora, O. Prieto-Ballesteros et al., J. Raman Spectrosc. 2023, 54, 1268.


  • Open Access

    The Raman Spectrometer for the ExoMars-ESA 2022 Mission to Mars

    by Fernando Rull, Andoni Moral, Guillermo Lopez-Reyes, Carlos Perez, Jose Antonio Rodriguez, Pablo Rodriguez, Marco Veneranda, Jose Antonio Manrique, Jesus Saiz, Aurelio Sanz, et al.

    IntroductionThe Raman Laser Spectrometer (RLS) [1] is part of the analytical instrumental suite (Pasteur Payload) located inside the Analytical Laboratory Drawer (ALD) of the Rosalind Franklin rover for the ExoMars 2022 mission to Mars. RLS is based on the inelastic scattering of the matter when illuminated by a monochromatic light. This emitting radiation contains physicochemical information of the observed material through the vibrations of its atomic components. It this way RLS will contribute to the ExoMars scientific mission objectives identifying minerals and organic compounds at the mineral grain scale. And with this information supporting the key astrobiological questions the mission will address analyzing samples on the Martian surface and subsurface.The instrument consists in four main units which are depicted in Figure 1 and its development and delivered models are described in references [1–5].In this work interest is mainly devoted to the analysis of the scientific performances of the flight model (FM) currently integrated in the Rosalind Franklin rover, comparing it with the performances of the flight spare (FS) located at INTA in Madrid. This comparison is part of the general plan to characterize both instruments to better understand the FM behavior in support to the future operation in Mars. This plan also includes the correlation of the FS scientific outcome and the RLS ExoMars Simulator, a laboratory setup located in Valladolid University [6] emulating the RLS acquisition algorithms [7], as well as the sample preparation and distribution system (SPDS) positioning of the samples. Figure 1. RLS instrument units. a) The SPU is the Spectrometer Unit, with a theoretical spectral resolution of 6-8 cm-1 [5]. b) The internal Optical Head (iOH) features an autofocus system, with 50 microns collection and excitation fibers [2,8]. c) The ICEU is the control electronics unit, also integrating the redundant 532 nm excitation laser [9]. d) The Calibration Targets will allow the calibration of the instrument, as well as the spatial correlation of the field-of-views of the different instruments of the Rosalind Franklin Analytical Laboratory Drawer [3].ExperimentalThe instrument performances were evaluated after an appropriate calibration procedure that included observation of Ne and Ar-Hg emission lines to obtain the correlation function between pixels and correct wavelengths and the Raman observation of standard samples and the PET calibration target to obtain the right wavenumber positions.After that a campaign with selected samples of very different Raman molar efficiency was undertaken. In the FM case this campaign comprised the pre-delivery experiments with a limited set of samples, given the extremely tight delivery schedule for the flight instrument to ESA. Once after integration, only the Calibration Target material (PET) can be used for health or any other checks, as no samples will be introduced into the sealed ultra-clean zone of the analytical laboratory drawer (ALD) of the rover until arrival to Mars. However, the development of the RLS FS (identical in every sense to the FM), has provided a unique opportunity to perform thorough scientific analysis that will be used to properly characterize and parameterize the flight instrument. These experiments will be correlated with heavy duty analysis performed by the RLS ExoMars Simulator, which is designed to work in a laboratory environment, thus allowing the analysis of samples without the operational constraints of the RLS FS. Several samples relevant to Mars have been analyzed at the present. These samples are collected from the ADAMM database, a collection of materials representative of different Martian locations and specifically the landing sites of ExoMars 2022 (Oxia Planum) and Mars 2020 (Jezero Crater) missions, which is presented in this conference. In addition, synthetic mixtures of materials used to perform calibration curves for the quantification of mineral abundances from RLS data (publication in press), or other representative materials to optimize the acquisition parameters of the instrument are analyzed (a dedicated presentation is presented in this conference).Results and discussion In this conference we will present and discuss the evolution of Raman spectra of the CT acquired with the RLS FM instrument, to verify the evolution of the instrument throughout all the steps from the pre-delivery stage, including the spectra obtained in relevant environments during the Assembly, Integration and Test (AIT) phases of the ALD and rover integration process. And also, the results regarding the correlation of the FS instrument and the RLS ExoMars Simulator data to the RLS FM instrument. These results will be key for defining the instrument capabilities and expected scientific performance of the instrument once on Mars. AcknowledgementsMINECO grants ESP2014-56138-C3-1-R, ESP2014-56138-C3-2-R, ESP2107-87690-C3-1-R, ESP2107-87690-C3-3-R.References[1] F. Rull et al., et al. Astrobiology. 17 (2017) 627–654. https://doi.org/10.1089/ast.2016.1567.[2] A. Santiago et al. Proc. SPIE - Int. Soc. Opt. Eng., 2018. https://doi.org/10.1117/12.2313462.[3] G. Lopez‐Reyes et al. J. Raman Spectrosc. (2020) jrs.5832. https://doi.org/10.1002/jrs.5832.[4] A.G. Moral et al. J. Raman Spectrosc. (2019) jrs.5711. https://doi.org/10.1002/jrs.5711.[5] J.F. Cabrero et al. In: Proc. SPIE 11180 (2019) 115. https://doi.org/10.1117/12.2536035. [6] G. Lopez-Reyes et al. Eur. J. Mineral. 25 (2013) 721–733. https://doi.org/10.1127/0935-1221/2013/0025-2317.[7] G. Lopez-Reyes, F. Rull Pérez, J. Raman Spectrosc. 48 (2017) 1654–1664. https://doi.org/10.1002/jrs.5185.[8] G. Ramos et al. In: Proc. SPIE - Int. Soc. Opt. Eng., (2017). https://doi.org/10.1117/12.2277003.[9] P. Ribes-Pleguezuelo et al. Proc SPIE - Opt. Eng. 55(11), 116107 (2016), https://doi: 10.1117/1.OE.55.11.116107

  • Open Access

    The high-resolution map of Oxia Planum, Mars; the landing site of the ExoMars Rosalind Franklin rover mission

    by Peter Fawdon, Csilla Orgel, Solmaz Adeli, Matt Balme, Fred J. Calef, Joel M. Davis, Alessandro Frigeri, Peter Grindrod, Ernst Hauber, Laetitia Le Deit, et al.


  • Deuterated PET: The new verification target of the Raman spectrometer for the MMX mission to explore Phobos

    by Andoni G. Moral, Julio Mora, Olga Prieto‐Ballesteros, Oscar Ercilla, Guillermo Lopez‐Reyes, Carlos P. Canora, Laura J. Bonales, Maite Fernandez‐Sampedro, J.A. Sanz‐Arranz, Alejandro Herrera, et al.