Rui Marukuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rui Marukuchi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Hideyuki Takeuchi
Department of surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan
6 shared publications - Hironori Ohdaira
International University of Health and Welfare Hospital 3 Department of Surgery Tochigi, Japan
6 shared publications - Masashi Yoshida
Department of Surgery
6 shared publications - Norihiko Suzuki
Department of Surgery, International University of Health and Welfare Hospital, Nasushiobara City, Japan
6 shared publications - Satoshi Narihiro
Department of Surgery, The Jikei University Kashiwa Hospital, Kashiwa, Japan
6 shared publications - Teppei Kamada
Department of Surgery The Jikei University School of Medicine Tokyo Japan
6 shared publications
Latest Publications
- 1 March 2022
- Published by Elsevier in Surgical Oncology
- Vol. 40, 101672
Fluorescence ureteral navigation during laparoscopic surgery for clinically suspected stage T4 colorectal cancer: A cohort study
- 1 March 2022
- Published by Elsevier in Surgical Oncology
- Vol. 40, 101672
Fluorescence ureteral navigation during laparoscopic surgery for clinically suspected stage T4 colorectal cancer: A cohort study
- Open Access
- 9 July 2020
- Published by Springer Nature in Surgical Case Reports
- Vol. 6 (1) , 1-6
Magnetic compression anastomosis for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction: a case report
Background: Postoperative non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction is a rare complication. If endoscopic balloon dilation proves ineffective, patients need re-operation under general anesthesia and experience a high rate of postoperative complications. Magnetic compression anastomosis is a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. We report a case in which magnetic compression anastomosis was successfully performed to avoid re-operation for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction. Case presentation: A 70-year-old woman was admitted to our hospital for treatment of non-anastomotic stenosis of the proximal jejunum. Open total gastrectomy and Roux-en-Y reconstruction were performed 2 years previously for advanced gastric cancer at another hospital. She complained of anorexia and obstructed passage of food. No recurrence of gastric cancer was identified. Esophagogastroduodenoscopy showed circumferential membranous stenosis of the jejunum 3 cm distal to the esophago-jejunal anastomosis. Endoscopic balloon dilation was performed three times, but proved ineffective. Magnetic compression anastomosis was planned because the stenosis existed near the esophago-jejunal anastomosis and re-operation was a highly invasive procedure requiring intrathoracic anastomosis. Endoscopic balloon dilation preceded placement of the parent magnet on the anal side of the stenosis. Confirming the improvement of stenosis, the parent magnet was placed on the anal side of the stenosis during esophagogastroduodenoscopy. The parent magnet attached to nylon thread was fixed to the cheek to prevent magnet migration. A week after placing the parent magnet, restenosis was confirmed and the daughter magnet was placed via nylon thread on the oral side of the stenosis. The two magnets were adsorbed in the end-to-end direction across the stenosis. Magnets adsorbed in the end-to-end direction moved to the anal side 11 days after placement. Wide anastomosis was confirmed by esophagogastroduodenoscopy. Endoscopic balloon dilation was regularly performed to prevent restenosis after magnetic compression anastomosis. No complications were observed postoperatively. The patient was able to eat normally and successfully reintegrated into society. Conclusions: Magnetic compression anastomosis could be a feasible procedure to avoid surgery for non-anastomotic stenosis of the proximal jejunum after gastrectomy with Roux-en-Y reconstruction.
- 9 July 2020
- Published by Springer Nature in Surgical Case Reports
- Vol. 6 (1) , 1-6
Open AccessMagnetic compression anastomosis for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction: a case report
Background: Postoperative non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction is a rare complication. If endoscopic balloon dilation proves ineffective, patients need re-operation under general anesthesia and experience a high rate of postoperative complications. Magnetic compression anastomosis is a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. We report a case in which magnetic compression anastomosis was successfully performed to avoid re-operation for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction. Case presentation: A 70-year-old woman was admitted to our hospital for treatment of non-anastomotic stenosis of the proximal jejunum. Open total gastrectomy and Roux-en-Y reconstruction were performed 2 years previously for advanced gastric cancer at another hospital. She complained of anorexia and obstructed passage of food. No recurrence of gastric cancer was identified. Esophagogastroduodenoscopy showed circumferential membranous stenosis of the jejunum 3 cm distal to the esophago-jejunal anastomosis. Endoscopic balloon dilation was performed three times, but proved ineffective. Magnetic compression anastomosis was planned because the stenosis existed near the esophago-jejunal anastomosis and re-operation was a highly invasive procedure requiring intrathoracic anastomosis. Endoscopic balloon dilation preceded placement of the parent magnet on the anal side of the stenosis. Confirming the improvement of stenosis, the parent magnet was placed on the anal side of the stenosis during esophagogastroduodenoscopy. The parent magnet attached to nylon thread was fixed to the cheek to prevent magnet migration. A week after placing the parent magnet, restenosis was confirmed and the daughter magnet was placed via nylon thread on the oral side of the stenosis. The two magnets were adsorbed in the end-to-end direction across the stenosis. Magnets adsorbed in the end-to-end direction moved to the anal side 11 days after placement. Wide anastomosis was confirmed by esophagogastroduodenoscopy. Endoscopic balloon dilation was regularly performed to prevent restenosis after magnetic compression anastomosis. No complications were observed postoperatively. The patient was able to eat normally and successfully reintegrated into society. Conclusions: Magnetic compression anastomosis could be a feasible procedure to avoid surgery for non-anastomotic stenosis of the proximal jejunum after gastrectomy with Roux-en-Y reconstruction.
- Open Access
- 11 May 2020
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 55, 49-52
Near-infrared fluorescent clip guided gastrectomy: Report of 2 cases (Case reports)
Introduction: This is the first report on near-infrared fluorescent (NIRF) clip-guided gastrectomy. The NIRF clip, ZEOCLIP FS, emits NIRF signals when excited. We hypothesized that preoperative placement of the ZEOCLIP FS near a gastric lesion would allow fluorescence laparoscopic localization of the clip, and hence, the lesion, during surgery. We report this technique in two cases. Case presentation: Case 1: An 81-year-old female was diagnosed with early gastric cancer and a pedunculated 4 cm large hyperplastic polyp that had prolapsed into the duodenum, and was scheduled for laparoscopy-assisted distal gastrectomy, due to the potential risk of dissection of the polyp with the duodenal wall. On the day before surgery, ZEOCLIP FS clips were endoscopically placed at the cancer site and the polyp. The locations of the fluorescent clips were confirmed intraoperatively using a full-color fluorescence laparoscope. Case 2: An 81-year-old male was scheduled for laparoscopy-assisted total gastrectomy for gastric cancer under fluorescent clip-guidance. Clip locations could not be confirmed during initial intraoperative observation. However, when the stomach wall was raised using forceps during a second observation attempt, the fluorescent clip locations were confirmed. Discussion: In case 1, it was easy to confirm clip location, facilitating complete resection of early gastric cancer without dissecting the polyp. In case 2, the fluorescent clip was located by raising the stomach and adjusting the angle between the stomach wall and the fluorescence laparoscope. Conclusion: The positive results of these two cases warrant conducting feasibility studies for use of this method.
- 11 May 2020
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 55, 49-52
Open AccessNear-infrared fluorescent clip guided gastrectomy: Report of 2 cases (Case reports)
Introduction: This is the first report on near-infrared fluorescent (NIRF) clip-guided gastrectomy. The NIRF clip, ZEOCLIP FS, emits NIRF signals when excited. We hypothesized that preoperative placement of the ZEOCLIP FS near a gastric lesion would allow fluorescence laparoscopic localization of the clip, and hence, the lesion, during surgery. We report this technique in two cases. Case presentation: Case 1: An 81-year-old female was diagnosed with early gastric cancer and a pedunculated 4 cm large hyperplastic polyp that had prolapsed into the duodenum, and was scheduled for laparoscopy-assisted distal gastrectomy, due to the potential risk of dissection of the polyp with the duodenal wall. On the day before surgery, ZEOCLIP FS clips were endoscopically placed at the cancer site and the polyp. The locations of the fluorescent clips were confirmed intraoperatively using a full-color fluorescence laparoscope. Case 2: An 81-year-old male was scheduled for laparoscopy-assisted total gastrectomy for gastric cancer under fluorescent clip-guidance. Clip locations could not be confirmed during initial intraoperative observation. However, when the stomach wall was raised using forceps during a second observation attempt, the fluorescent clip locations were confirmed. Discussion: In case 1, it was easy to confirm clip location, facilitating complete resection of early gastric cancer without dissecting the polyp. In case 2, the fluorescent clip was located by raising the stomach and adjusting the angle between the stomach wall and the fluorescence laparoscope. Conclusion: The positive results of these two cases warrant conducting feasibility studies for use of this method.
- Open Access
- 30 March 2020
- Published by Springer Nature in Surgical Case Reports
- Vol. 6 (1) , 1-5
Magnetic compression anastomosis with atypical anastomosis for anastomotic stenosis of the sigmoid colon: a case report
Background: Magnetic compression anastomosis (MCA) is mainly applied in the gastrointestinal and biliary tracts through a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. Magnets usually adsorb in the end-to-end direction (end-to-end anastomosis), exert a strong magnetic force and create an anastomosis according to the size of the magnets. Regular endoscopic dilation is required to prevent restenosis when the anastomotic size is small. We report a case in which MCA was successfully used to treat anastomotic stenosis of the sigmoid colon; the magnets adsorbed in the side-to-side direction rather than the end-to-end direction and generated a wide anastomosis in a short time that did not require endoscopic dilation. Case presentation: An 81-year-old woman was admitted to our hospital to treat anastomotic stenosis of the sigmoid colon for closure of transverse colostomy. Two years prior, the Hartmann operation and drainage were performed at other hospitals due to perforated diverticulitis of the sigmoid colon. Obstruction of the sigmoid colostomy occurred, and a transverse colostomy was performed. One year after the first surgery, high anterior resection was performed, but anastomotic stenosis occurred, causing obstruction. MCA was planned because the patient had a history of multiple operations and was expected to have strong adhesions postoperatively. MCA was safely performed, but two magnets were accidently adsorbed in the side-to-side direction. The magnet position could not be changed. The two magnets were expected to move and adsorb in an end-to-end direction naturally due to bowel movements. The magnets that adsorbed in the side-to-side direction dropped from the anus 5 days after treatment, and the anastomosis was observed by colonoscopy. Three ileus tubes were placed from the transverse colostomy beyond the anastomosis to prevent restenosis. Colonoscopy showed that the anastomosis diameter was wider than expected at 14 days after treatment, and endoscopic dilation was not necessary. No complications were observed in this patient’s postoperative course. Finally, closure of the patient’s colostomy was successfully performed. Conclusions: MCA with side-to-side anastomosis generated a wide anastomosis in a short time.
- 30 March 2020
- Published by Springer Nature in Surgical Case Reports
- Vol. 6 (1) , 1-5
Open AccessMagnetic compression anastomosis with atypical anastomosis for anastomotic stenosis of the sigmoid colon: a case report
Background: Magnetic compression anastomosis (MCA) is mainly applied in the gastrointestinal and biliary tracts through a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. Magnets usually adsorb in the end-to-end direction (end-to-end anastomosis), exert a strong magnetic force and create an anastomosis according to the size of the magnets. Regular endoscopic dilation is required to prevent restenosis when the anastomotic size is small. We report a case in which MCA was successfully used to treat anastomotic stenosis of the sigmoid colon; the magnets adsorbed in the side-to-side direction rather than the end-to-end direction and generated a wide anastomosis in a short time that did not require endoscopic dilation. Case presentation: An 81-year-old woman was admitted to our hospital to treat anastomotic stenosis of the sigmoid colon for closure of transverse colostomy. Two years prior, the Hartmann operation and drainage were performed at other hospitals due to perforated diverticulitis of the sigmoid colon. Obstruction of the sigmoid colostomy occurred, and a transverse colostomy was performed. One year after the first surgery, high anterior resection was performed, but anastomotic stenosis occurred, causing obstruction. MCA was planned because the patient had a history of multiple operations and was expected to have strong adhesions postoperatively. MCA was safely performed, but two magnets were accidently adsorbed in the side-to-side direction. The magnet position could not be changed. The two magnets were expected to move and adsorb in an end-to-end direction naturally due to bowel movements. The magnets that adsorbed in the side-to-side direction dropped from the anus 5 days after treatment, and the anastomosis was observed by colonoscopy. Three ileus tubes were placed from the transverse colostomy beyond the anastomosis to prevent restenosis. Colonoscopy showed that the anastomosis diameter was wider than expected at 14 days after treatment, and endoscopic dilation was not necessary. No complications were observed in this patient’s postoperative course. Finally, closure of the patient’s colostomy was successfully performed. Conclusions: MCA with side-to-side anastomosis generated a wide anastomosis in a short time.
- Open Access
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 75 (C) , 418-421
Introduction of VISIONSENSE® for indocyanine green fluorescence-guided parathyroidectomy
Introduction: VISIONSENSE® is a new near-infrared (NIR) fluorescence laparoscope and has an NIR overlay threshold function that allows us to set a floor for the NIR signal to be included in the overlay. We report the case of a patient who underwent indocyanine green (ICG) fluorescence-guided parathyroidectomy for primary hyperparathyroidism due to parathyroid adenoma using the threshold-adjustment function of VISIONSENSE®. Presentation of case: A 40-year-old man was referred to our department for examination and treatment of hypercalcemia. ICG fluorescence-guided parathyroidectomy using VISIONSENSE® was planned on diagnosis of primary hyperparathyroidism due to parathyroid tumor. In the operation, we were unable to readily recognize the parathyroid gland (PG). After intravenous injection of ICG, fluorescence from ICG appeared from the left thyroid lobe to the PG, but PG contours remained unclear. We therefore used the threshold-adjustment function of VISIONSENSE® to discard NIR signal values <50%. Clear contours of the PG were subsequently obtained, allowing recognition of the gland and successful ICG-guided parathyroidectomy. No postoperative complications were encountered and the pathological diagnosis was parathyroid adenoma. Discussion: In our case, both PG and thyroid showed ICG fluorescence, but the intensity of thyroid fluorescence was slightly little lower than that of PG fluorescence. To differentiate between fluorescence from PG and thyroid, the threshold-adjustment function of VISIONSENSE® may prove useful. Conclusion: This case suggests that the threshold-adjustment function of VISIONSENSE® may be useful to readily identify the PG in parathyroid surgery. Highlights:
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 75 (C) , 418-421
Open AccessIntroduction of VISIONSENSE® for indocyanine green fluorescence-guided parathyroidectomy
Introduction: VISIONSENSE® is a new near-infrared (NIR) fluorescence laparoscope and has an NIR overlay threshold function that allows us to set a floor for the NIR signal to be included in the overlay. We report the case of a patient who underwent indocyanine green (ICG) fluorescence-guided parathyroidectomy for primary hyperparathyroidism due to parathyroid adenoma using the threshold-adjustment function of VISIONSENSE®. Presentation of case: A 40-year-old man was referred to our department for examination and treatment of hypercalcemia. ICG fluorescence-guided parathyroidectomy using VISIONSENSE® was planned on diagnosis of primary hyperparathyroidism due to parathyroid tumor. In the operation, we were unable to readily recognize the parathyroid gland (PG). After intravenous injection of ICG, fluorescence from ICG appeared from the left thyroid lobe to the PG, but PG contours remained unclear. We therefore used the threshold-adjustment function of VISIONSENSE® to discard NIR signal values <50%. Clear contours of the PG were subsequently obtained, allowing recognition of the gland and successful ICG-guided parathyroidectomy. No postoperative complications were encountered and the pathological diagnosis was parathyroid adenoma. Discussion: In our case, both PG and thyroid showed ICG fluorescence, but the intensity of thyroid fluorescence was slightly little lower than that of PG fluorescence. To differentiate between fluorescence from PG and thyroid, the threshold-adjustment function of VISIONSENSE® may prove useful. Conclusion: This case suggests that the threshold-adjustment function of VISIONSENSE® may be useful to readily identify the PG in parathyroid surgery. Highlights:
- Open Access
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 69 (C) , 5-9
PINPOINT® can be used for photodynamic diagnosis based on 5-aminolevulinic acid-induced protoporphyrinIX in gastric cancer surgery
Introduction: Photodynamic diagnosis (PDD) using 5-aminolevulinic acid (5-ALA) has been used as a diagnostic procedure for malignant diseases. Dedicated laparoscopes (e.g., an IMAGE1 Camera System®) are used for this procedure. We report a case treated with laparoscopic total gastrectomy with 5-ALA-PDD using the PINPOINT® system. Presentation of case: A patient in his 80 s with diffuse-type gastric cancer with pyloric stenosis and ascites was admitted to our hospital. Double percutaneous transesophageal gastrotubing (dPTEG) for both gastric decompression and enteral nutrition and two cycles of preoperative chemotherapy with S-1 plus oxaliplatin were performed preoperatively. Additionally, we preoperatively performed an ex vivo experiment that confirmed that the PINPOINT® system can be used to observed protoporphyrin IX (PpIX) fluorescence. Three hours before surgery, 5-ALA hydrochloride was administered through dPTEG. Observation was performed by PINPOINT®, and Aladuck® was used as an excitation light source. Peritoneal nodules and sampled lymph nodes with red fluorescence were observed by 5-ALA-PDD. Accordingly, we gave up a radical operation and laparoscopic total gastrectomy without systematic lymphadenectomy to improve anemia and release pyloric stenosis was performed. The patient’s postoperative course was uneventful. Discussion: It is possible that the connection with each of the scopes and an exclusive light source (Aladuck®) enable the easy use of 5-ALA-PDD without dedicated laparoscopy. It is expected that 5-ALA-PDD would show the further spread of gastrointestinal cancer if it could be performed with many types of laparoscopes. Conclusion: We found that 5-ALA-PDD-guided surgery can be easily performed in a short time using the PINPOINT® system. Highlights:
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 69 (C) , 5-9
Open AccessPINPOINT® can be used for photodynamic diagnosis based on 5-aminolevulinic acid-induced protoporphyrinIX in gastric cancer surgery
Introduction: Photodynamic diagnosis (PDD) using 5-aminolevulinic acid (5-ALA) has been used as a diagnostic procedure for malignant diseases. Dedicated laparoscopes (e.g., an IMAGE1 Camera System®) are used for this procedure. We report a case treated with laparoscopic total gastrectomy with 5-ALA-PDD using the PINPOINT® system. Presentation of case: A patient in his 80 s with diffuse-type gastric cancer with pyloric stenosis and ascites was admitted to our hospital. Double percutaneous transesophageal gastrotubing (dPTEG) for both gastric decompression and enteral nutrition and two cycles of preoperative chemotherapy with S-1 plus oxaliplatin were performed preoperatively. Additionally, we preoperatively performed an ex vivo experiment that confirmed that the PINPOINT® system can be used to observed protoporphyrin IX (PpIX) fluorescence. Three hours before surgery, 5-ALA hydrochloride was administered through dPTEG. Observation was performed by PINPOINT®, and Aladuck® was used as an excitation light source. Peritoneal nodules and sampled lymph nodes with red fluorescence were observed by 5-ALA-PDD. Accordingly, we gave up a radical operation and laparoscopic total gastrectomy without systematic lymphadenectomy to improve anemia and release pyloric stenosis was performed. The patient’s postoperative course was uneventful. Discussion: It is possible that the connection with each of the scopes and an exclusive light source (Aladuck®) enable the easy use of 5-ALA-PDD without dedicated laparoscopy. It is expected that 5-ALA-PDD would show the further spread of gastrointestinal cancer if it could be performed with many types of laparoscopes. Conclusion: We found that 5-ALA-PDD-guided surgery can be easily performed in a short time using the PINPOINT® system. Highlights:
- 30 September 2019
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 39 (10) , 5755-5760
Risk Factors for Deterioration of Remnant Liver Function After Hepatic Resection for Hepatocellular Carcinoma
Background/Aim: After primary resection of hepatocellular carcinoma (HCC), the impact of patient's characteristics at the initial hepatectomy, on long-term remnant liver function has not been reported. The aim of this study was to identify factors associated with the deterioration of remnant liver function among patients who developed recurrent HCC. Patients and Methods: A total of 51 patients with intrahepatic recurrence after initial hepatic resection for HCC were included. We retrospectively investigated the relation between patient characteristics and the degree of deterioration of remnant liver function upon recurrence. Results: In univariate analysis, significant predictors of deterioration of remnant liver function consisted of preoperative gastro-esophageal varices (p=0.0101), preoperative transcatheter arterial chemoembolization (p=0.0230) and hepatectomy beyond Makuuchi's criteria (p=0.0101). In multivariate analysis, the only significant independent predictor of deterioration of remnant liver function was hepatectomy beyond Makuuchi's criteria (p=0.0498). Conclusion: Hepatectomy beyond Makuuchi's criteria at the initial hepatectomy may predict deterioration of remnant liver function upon recurrence of HCC.
- 30 September 2019
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 39 (10) , 5755-5760
Risk Factors for Deterioration of Remnant Liver Function After Hepatic Resection for Hepatocellular Carcinoma
Background/Aim: After primary resection of hepatocellular carcinoma (HCC), the impact of patient's characteristics at the initial hepatectomy, on long-term remnant liver function has not been reported. The aim of this study was to identify factors associated with the deterioration of remnant liver function among patients who developed recurrent HCC. Patients and Methods: A total of 51 patients with intrahepatic recurrence after initial hepatic resection for HCC were included. We retrospectively investigated the relation between patient characteristics and the degree of deterioration of remnant liver function upon recurrence. Results: In univariate analysis, significant predictors of deterioration of remnant liver function consisted of preoperative gastro-esophageal varices (p=0.0101), preoperative transcatheter arterial chemoembolization (p=0.0230) and hepatectomy beyond Makuuchi's criteria (p=0.0101). In multivariate analysis, the only significant independent predictor of deterioration of remnant liver function was hepatectomy beyond Makuuchi's criteria (p=0.0498). Conclusion: Hepatectomy beyond Makuuchi's criteria at the initial hepatectomy may predict deterioration of remnant liver function upon recurrence of HCC.
- Open Access
- 1 January 2019
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 64 (C) , 170-173
A novel fluorescent marking clip for laparoscopic surgery of colorectal cancer
Introduction: In laparoscopic surgery, marking of tumor location has been gaining importance. Tattoo marking has been often used but the technique carries the risk of accidental peritoneal scattering or other organ injury. We have been involved in the development of a novel fluorescent clip for marking tumor sites and supposed that its usage would reduce risks related to other marking methods. Case presentation: A 52-year-old man was diagnosed with sigmoid colon cancer and polyp, and was scheduled for laparoscopic sigmoidectomy. On the day before operation, fluorescent clips (ZEOCLIP FS: Zeon Medical co, Ltd, Tokyo) were endoscopically placed around the tumor and polyp sites, 4 clips for each lesion attached every 90 degrees within the colonic lumen, respectively. During the operation, locations of the fluorescent clips were easily confirmed using a full-color fluorescent laparoscope, VISION SENSE (Medtronic Co., U.S.). Curative operation was performed accordingly with the preoperative pathological and radiological findings. The postoperative course was uneventful. Discussion: Locations of intraluminally placed fluorescent clips were clearly and easily recognized through the serosal layer of the intestinal wall using a fluorescent laparoscope. Complications related to dye scattering or intestinal wall/other organ perforation were not observed suggesting that future incorporation of this tumor site marking technique into laparoscopic surgery might be beneficial. Conclusion: The fluorescent marking clips were easily placed and recognized with a fluorescent laparoscope. This method is expected to be safe and risks of accidental puncture related to tattoo marking method can be reduced or almost eliminated. Highlights:
- 1 January 2019
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 64 (C) , 170-173
Open AccessA novel fluorescent marking clip for laparoscopic surgery of colorectal cancer
Introduction: In laparoscopic surgery, marking of tumor location has been gaining importance. Tattoo marking has been often used but the technique carries the risk of accidental peritoneal scattering or other organ injury. We have been involved in the development of a novel fluorescent clip for marking tumor sites and supposed that its usage would reduce risks related to other marking methods. Case presentation: A 52-year-old man was diagnosed with sigmoid colon cancer and polyp, and was scheduled for laparoscopic sigmoidectomy. On the day before operation, fluorescent clips (ZEOCLIP FS: Zeon Medical co, Ltd, Tokyo) were endoscopically placed around the tumor and polyp sites, 4 clips for each lesion attached every 90 degrees within the colonic lumen, respectively. During the operation, locations of the fluorescent clips were easily confirmed using a full-color fluorescent laparoscope, VISION SENSE (Medtronic Co., U.S.). Curative operation was performed accordingly with the preoperative pathological and radiological findings. The postoperative course was uneventful. Discussion: Locations of intraluminally placed fluorescent clips were clearly and easily recognized through the serosal layer of the intestinal wall using a fluorescent laparoscope. Complications related to dye scattering or intestinal wall/other organ perforation were not observed suggesting that future incorporation of this tumor site marking technique into laparoscopic surgery might be beneficial. Conclusion: The fluorescent marking clips were easily placed and recognized with a fluorescent laparoscope. This method is expected to be safe and risks of accidental puncture related to tattoo marking method can be reduced or almost eliminated. Highlights: