FRFabian Oswaldo Romero-Soto

Fabian Oswaldo Romero-Soto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabian Oswaldo Romero-Soto has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrothermally Engineered CdS/rGO Nanocomposite for Ultra-Trace Electrochemical sensing of Copper Ions

    by Muhammad Sajid Shafiq, Fabian O. Romero-Soto, Martín F. Jiménez-Moreno, Amritha Kadathamana, Masoud Madadelahi, Marc Madou, Josue Amilcar Aguilar Martinez, Rudra Kumar

    A highly sensitive and selective Cu2+ electrochemical sensor was fabricated by functionalizing a glassy carbon electrode (GCE) with a CdS/rGO nanocomposite. The structural integrity and surface morphology of the prepared materials were thoroughly characterized through XRD, FESEM, EDX, FTIR, Raman spectroscopy, and XPS, which verified the successful formation of the CdS/rGO nanocomposite through a hydrothermal synthesis approach. The electrochemical behaviour of the modified electrode was systematically evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse anodic stripping voltammetry (DPASV). The results demonstrated enhanced electrocatalytic activity, as indicated by pronounced anodic and cathodic peak currents that unveiled a linear behavior with scan rates ranging from 50 to 250 mV s-1. Under optimized experimental conditions, the sensor showed excellent analytical results across a concentration range of 10 -100 nM with a detection limit (LOD) as low as 3.19 nM for Cu2+ ions. Moreover, the developed sensor displayed strong resistance to interference ions, along with good reproducibility and long-term operational stability. Its practical applicability was further confirmed by the effective determination of Cu2+ ions in both water samples and more complex matrices, with acceptable recovery values, proving its reliability and cost-effectiveness in practical use.

  • (Digital Presentation) An Electrochemical Sensor in a Disc for Real-Time PCR Assisted with Thermal Convective Flow

    by Fabian Oswaldo Romero-Soto, Mohammad Mahdi Aeinehvand, Marc Madou, Sergio Omar Martinez-Chapa

    Nowadays, the polymerase chain reaction (PCR) has extensively adapted to microfluidic devices for several features such as the low consumption of reagents and sample, portability, high-throughput, and low fabrication costs [1]. The reduction of the amplification time has been a relevant parameter since the invention of the PCR, where rapid microfluidic PCR is especially preferred for the detection of infectious diseases [1,2]. The continuous-flow-based PCR is a type of microfluidic PCR that proposes the mobilization of the PCR mixture through a microchannel with different fixed temperature zones to achieve the required thermal-cycling [3]. This approach has smaller thermal inertia because only the PCR mixture needs to be heated and cooled instead of the entire microfluidic device. The continuous-flow approach allows rapid-thermal cycling with lower power consumption and, therefore, reduces the overall amplification time. The Lab-on-a-disc, or centrifugal microfluidic platform, has adapted the continuous-flow PCR by utilizing the flow generated by thermal convection in a ring-structured microchannel [4]. During spinning, embedded heaters in the bottom of the CD heat specific section of the microchannel (see Figure 1) at a fixed temperature and, subsequently, create a natural convection flow in the PCR mixture and move through the microchannel. The centrifugal-assisted thermal convection (CATC) technique not only enables the recirculation pathway for the continuous-flow PCR but overcomes the unidirectional nature of centrifugation force on the CD. Despite the advantage of rapid PCR on Lab-on-a-Disc, the CATC technique lacks the implementation of a detection method with high sensitivity and resolution, aiming for a fully integrated microfluidic platform. Electrochemical detection can provide fast responses with minimum power consumption for miniaturized devices. This work proposes the integration of an electrochemical sensor to the CATC technique in a circular microchannel for the real-time monitoring of DNA amplification. The electrochemical sensor consists of interdigitated gold electrodes located above the ring microchannel to quantify the amplicon concentration after each cycle mediated by the intercalation of Methylene Blue between the newly-generated DNA (see figure 1A). The characterization of the sensor is performed through voltammetric techniques such as cyclic voltammetry (CV) and linear sweep voltammetry (LSV), where the latter is utilized for amplicon quantification. To optimize the CATC technique combined with the electrochemical sensor, a COMSOL simulation is performed to improve the amplification ratio and amplification time in the CD by analyzing the microchannel geometry and flow rate (see figure 1B). Both the thermal control for the thermal-assisted microchannel and the electrochemical sensor are powered and controlled via the “electrified Lab-on-a-Disc” (eLoaD) board [5] (see figure 1C). [1] Y. Zhang, P. Ozdemir, Anal. Chim. Acta 638 (2009) 115–125. [2] X. Dong, L. Liu, Y. Tu, J. Zhang, G. Miao, L. Zhang, S. Ge, N. Xia, D. Yu, X. Qiu, TrAC - Trends Anal. Chem. 143 (2021) 116377. [3] M.B. Kulkarni, S. Goel, Eng. Res. Express 2 (2020). [4] M. Saito, K. Takahashi, Y. Kiriyama, W.V. Espulgar, H. Aso, T. Sekiya, Y. Tanaka, T. Sawazumi, S. Furui, E. Tamiya, Anal. Chem. 89 (2017) 12797–12804. [5] S.M. Torres Delgado, J.G. Korvink, D. Mager, Biosens. Bioelectron. 117 (2018) 464–473. Figure 1

  • (Digital Presentation) An Electrochemical Sensor in a Disc for Real-Time PCR Assisted with Thermal Convective Flow

    by Fabian Oswaldo Romero-Soto, Mohammad Mahdi Aeinehvand, Marc Madou, Sergio Omar Martinez-Chapa

    Multiple microfluidic devices incorporating real-time polymerase chain reaction (PCR) for the quantification of DNA targets have been reported. They show features such as fast analysis time, reduced reagent consumption, and portability. Integration of real-time PCR in a centrifugal microfluidic disc has been also proposed due to the ease of automation and parallelization of microfluidic operations. Previously, it has been demonstrated the implementation of thermal convective PCR (TC-PCR) in a CD using a ring-structured microchannel. In this case, the microchannel is supplied with the temperature necessary to perform the complete thermal cycle: Denaturation, annealing, and extension. The flow generated by thermal convection, in combination with the centrifugal force moves the sample through the entire microchannel due to the difference in densities. In this work, we present the implementation in a CD of an electrochemical sensor combined with TC-PCR to quantify the amplification yield in real-time. We present advances related to the calibration of the electrochemical sensor, and the implementation of the TC-PCR in a CD as well as a preliminary simulation in COMSOL.

  • Comparative Analysis of Alpha Power Spectral Density in Real and Virtual Environments

    by Fabian O. Romero-Soto, David I. Ibarra-Zárate, Luz Maria Alonso-Valerdi


  • Implementation of a Virtual Reality rendered in Portable Devices for Strabismus Treatment based on Conventional Visual Therapy

    by Luis K. Cepeda-Zapata, Fabian O. Romero-Soto, Victor A. Diaz de Leon, Jessica L. Roa-Huertas, Norberto E. Naal-Ruiz, David Ibarra-Zarate, Luz M. Alonso-Valerdi

    In order to propose alternative treatments for strabismus, conventional visual therapies implemented in VR, which could be rendered in portable devices for pediatric strabismus treatment is proposed in this paper. In comparison with other virtual environments for visual correction proposes, the proposed system is based on conventional visual therapies for amblyopia and strabismus treatment. Three fundamental visual therapeutic exercises were considered in the present proposal: (1) Brock cord, (2) approach technique, and (3) convergence and divergence. The first exercise, Brock Cord, has the purpose of improving the binocular fixation for exotropia and esotropia. The second exercise pursues to normalize the Cerebral Perfusion Pressure by an approach technique. The third exercise known as fusion of eccentric circles, aims vision training by converging and diverging objects at specific distances. Before a clinical application, it was paramount important to guarantee system simplicity and versatility for both clinicians and infant patients. Therefore, the user experience evaluation of a sample of 45 students between 17 and 28 years old was undertaken. The system proposed in this paper achieved a pragmatic quality above average (1.73), a parameter that reflects simplicity and versatility. In addition, the present VR system displayed attractiveness (2.03) and hedonic (1.90) qualities above average. Then, it is expected that end-users will follow the visual exercise program.


  • Electrolysis Pumping on Centrifugal Microfluidic Platforms for Automation of Bioanalytical Assays

    by Fabian Oswaldo Romero Soto, MohammadMahdi Aeinehvand, Martin Francisco Jimenez Moreno, Dario Mager, Marc J Madou, Sergio Omar Martínez-Chapa

    One of the advantages of Lab on a Disc (LoD), compared to Lab on a Chip (LoC), is the use of centrifugal forces to move liquids within the chambers and microchannels; eliminating the need of external mechanical pumps (e.g., syringe pump) and piping networks for the automatization of bioanalytical assays. However, the centrifugal force is unidirectional and therefore liquids can only be displaced from the center to the edge of the disc. This prevents the possibility of utilizing all the available space in the disc for the implementation of a complex microfluidic process. To overcome this limitation, we developed an electrolysis system to induce a pneumatic force to move liquids towards the center of a spinning disc or against the direction of centrifugal force. We developed a microfluidic disc that contains a series of electrolysis pumps and peptide microarrays to automate a multiplexed immunoassay for the detection of different antibodies e.g., Ha and anti-flag antibodies. The pumps on this centrifugal microfluidic platform are powered and controlled wirelessly using the electronics-LoD [1]. In general, the develop pumping system allows for the best use of the limited space of microfluidic disc and the automation of complex bioanalytical process for point of care applications. [1] S.M.T. Delgado, D.J. Kinahan, F.S. Sandoval, L.A.N. Julius, N.A. Kilcawley, J. Ducrée, D. Mager, Fully automated chemiluminescence detection using an electrified-Lab-on-a-Disc (eLoaD) platform, Lab Chip. 16 (2016) 4002–4011. doi:10.1039/C6LC00973E.