Zhi Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhi Su has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Biao Wei
Aeronautical Engineering College, Air Force Engineering University, Xi’an 710038, China
1 shared publication - Bingliang Tang
Science and Technology on Plasma Dynamics Laboratory, Air Force Engineering University, Xi’an 710038, China
1 shared publication - Hua Liang
Air Force Engineering University, Science and Technology on Plasma Dynamics Laboratory, Xi'an, 710038, CHINA
1 shared publication - Like Xie
Science and Technology on Plasma Dynamics Laboratory, Air Force Engineering University, Xi'an 710038, China
1 shared publication - Menghu Han
Air Force Harbin Flight Academy, Harbin 150000, China
1 shared publication - Zhong-Guo Niu
Science and Technology on Plasma Dynamics Laboratory, Air Force Engineering University 1 , Xi’an 710038, China
1 shared publication
Latest Publications
- Open Access
Experimental Study on Plasma Flow Control of Symmetric Flying Wing Based on Two Kinds of Scaling Models
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.
Open AccessExperimental Study on Plasma Flow Control of Symmetric Flying Wing Based on Two Kinds of Scaling Models
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.