MÊMarco Túlio Alves Êvo

Marco Túlio Alves Êvo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marco Túlio Alves Êvo has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Tool for the Assessment of the Savings in the Cable Acquisition When Employing DC Transmission in Long Distance AC Drives

    by André Mendonça Alzamora, Caio Eduardo Silva, Marco Tulio Alves Êvo, Hélder de Paula

    Throughout different stages of the mining processes, alternating current (AC) motors powered by pulse width modulation (PWM) converters are employed, typically connected by extensive cable lengths. While these drives bring forth significant advantages, they also give rise to challenges associated with high-frequency problems, which, in turn, reduce the operational lifespan of the system components. Off-the-shelf solutions, involving the incorporation of passive filters, tend to adversely affect both the cost and efficiency of the system, justifying research for new alternatives. A recent proposal suggests a distinctive approach, wherein the frequency converter is divided into its rectifier and inverter units. The former is situated in its original location, while the latter is positioned close to the load. Consequently, the drive system operates with direct current (DC) for electric power transmission. This innovative topology not only eliminates the high-frequency problems but also substantially enhances efficiency while reducing costs of the transmission. Prior research has demonstrated the potential of this alternative drive topology, particularly through case studies in low- and medium-voltage systems within mining plants. In this paper, the economic and energy efficiency potentials of such DC transmission drives regarding the power transmission are examined using reference graphs that offer insights beyond conventional case studies. These graphs represent decision-making tools, allowing for a quick and accessible assessment of the economic viability of the alternative topology for a wide range of powers and drive distances. The main aspects related to the methodology, along with relevant technical discussions, are addressed.


  • Open Access

    Early Fault Detection in FOC Driven Induction Motors: A Case Study

    by Isabela O. Zaparoli, Arismar M. G. Júnior, Marco Túlio A. Êvo, Diogo S. C. Souza, Hélder de Paula

    Across various productive sectors, failures in electric motors can lead to financial losses, poor production quality, and accidents. Even though motors in high-performance/precision applications are controlled in a closed loop, this category of drive is the least explored in the literature when the subject falls on the detection of inter-turn stator insulation faults, despite closed loop being the most complex among such systems. This complexity arises as the closed-loop control structure drastically modifies or even conceals fault signatures, thus making identification extremely difficult. In this context, among the methodologies currently developed, while considering the existing literature, one specific methodology has shown promising results, making it attractive for practical applications – Gama index. The work presented by those authors significantly contributed to the area of fault detection by proposing the fault index called Gama. However, this study did not address important issues related to the problem that are crucial for validating the fault index presented in that work. Therefore, the present article adds value to the area of fault detection by developing a complementary case study to characterize the performance and accuracy of the Gama index under different situations. These situations include the application of a different control structure for motor drive, the consideration of mechanical faults occurring in the motor simultaneously with the inter-turn short-circuit, along with the application of the technique to a motor with a higher power rating, and, finally, the operation of the machine at different speeds.


  • Design for Reliability of DC-Link Capacitors for Multilevel Inverter Topologies Operating in Hostile Environments

    by Caio Eduardo Silva, André M. Alzamora, Marco T. A. Êvo, Hélder de Paula

    Especially in the mining industry, Pulse Width Modulated Voltage Source Converters (PWM-VSC) are commonly used to drive induction motors at long distances from the inverter. However, this can cause unwanted high-frequency phenomena due to the long cables used for the converter-to-motor connection. A new configuration has been proposed to address this issue, keeping the rectifier in its original location while installing the inverter bridge close to the motor terminals. However, this new configuration can compromise the inverter's lifetime in hostile environments. This paper presents a study on the reliability of DC-Link capacitors for Three Level Neutral Point Clamped (3L-NPC), Three Level Active Neutral Point Clamped (3L-ANPC), and Five Level H-Bridge Neutral Point Clamped (5L-HNPC) inverter topologies in these environments, using methodologies based on Physics of Failure (PoF) and Design for Reliability (DfR).


  • Handling Stray Flux Signals for Stator Turn Insulation Degradation Monitoring

    by Paulo C. M. Lamim Filho, Fabiano B. Batista, Marco T. A. Êvo, Juscelino H. B. Silva, Lane M. Rabelo

    Considering that induction motors serve as prevalent drivers for industrial loads and recognizing that the deterioration of insulating material between stator turns can culminate in catastrophic failures, the periodic assessment of motor insulation emerges as an imperative task. Such vigilant oversight is indispensable for averting irreparable damage to the machinery and mitigating potential production losses. This study presents a sensor and methodology for practical deployment, detecting turn insulation deterioration. A noteworthy attribute of this method resides in its utilization of low-direct voltages to the machine winding as an alternative to the well-known offline Surge Test, thereby guaranteeing the preservation of insulation integrity. The development and fine-tuning of both the sensor and the diagnostic technique were underpinned by the application of Finite Element Analysis (FEA). Subsequently, the accuracy and reliability of the simulated results were compared to experimental tests. The method exhibits characteristics that render it suitable for industrial applications, including facile sensor positioning, the application of alternating voltage below nominal levels, a low signal acquisition rate, and the diagnostic standard being the Root Mean Square (RMS) value of the flux.


  • Electrostatic Shield to Mitigate the High Frequency Circulating Bearing Current–A Study for Design Guidelines

    by Marco Túlio Alves Êvo, Caio Eduardo Silva, Isabela O. Zaparolli, Hélder de Paula

    In a previous work, the authors addressed electrostatic shielding to reduce the bearing discharge currents (Electrostatic discharge machining currents - EDM). In order to expand the application of such a shielding device, this paper presents an analysis of its use to reduce the inverter-induced circulating bearing currents on induction machines. Employing finite element analysis (FEA), 2D and 3D models were developed to clarify the tradeoff between the shield effectiveness and the associated additional heat losses and motor efficiency reduction, considering different geometric arrangements and materials for the shielding device construction. The results provide very good guidelines for the shield design, contributing to its practical application viability. It is shown that it is possible to design a shielding configuration that achieves a high mitigating level with a negligible impact on the motor efficiency and developed torque. Furthermore, comparing calculation models of different complexities, the paper also shows the importance of representing all capacitive couplings inside the motor and the non-uniform current distribution in the shield to determine its effectiveness. Since a large fraction of the motor failures are caused by bearing currents, this paper can provide benefits to key topics for industry, such as equipment reliability and availability.


  • Electrostatic Shielding for Bearing Current Mitigation–An Analysis of its Thermal Impact on the Motor

    by Marco Túlio Alves Êvo, Arismar M. G. Júnior, Caio Eduardo Silva, Hélder de Paula

    This work presents a study on the use of electrostatic shields to reduce bearing currents (both Electrostatic discharge machining and circulating currents), focusing on its thermal impact on the motor operation. 2-D finite element models are utilized to analyze the temperature distribution inside the coil winding slot of motors both with and without shielding. The results show that the shielding device can be used with a negligible influence on the temperature rise inside the slot. In addition, it is demonstrated that for some shield configurations, the stator winding eddy current loss can be attenuated. In such cases, the shield presence can also lead to a temperature reduction in the stator conductors. Furthermore, the developed models can be expanded to be used in the analysis of any other motor equipped with this type of solution, aiding the design and implementation of the shielding device. Keeping in mind that the majority of the motor failures are due to bearing problems, this article contributes to the industry by addressing issues closely related to the reliability topic, such as solutions to increase the motor availability, which is the very case of the shielding device.


  • Inverter-Induced Bearing Currents: A Thorough Study of the Cause-and-Effect Chains

    by Marco T.A. Êvo, André M. Alzamora, Isabela O. Zaparoli, Hélder de Paula

    In the last three decades, the study of inverter-induced bearing currents has become a very important line of research, and hundreds of works related to this theme can be found in the literature. Thus, several contributions concerning these currents were made, such as in the areas of modeling and simulation techniques, selection of appropriate mitigation method, developments of new mitigation devices, and damage monitoring within the bearings, among others. In this context, much information related to bearing currents cause-and-effect chains is available. However, many contributions that have been developed in recent years for describing the mechanisms behind the bearing currents occurrence can only be found in a fragmented way. Thus, great efforts must be employed to provide a clear comprehension of each bearing current type and all the corresponding issues. To overcome this problem, this article provides a broad overview of the physical principles related to the inverter-induced bearing current, by means of a detailed and didactic approach. A huge volume of information was compiled, describing the expected currents maximum amplitudes, their probability of occurrence, and the motor size which they are more expected to occur, among other relevant issues.


  • Open Access

    Electrostatic shielding for bearings discharge currents attenuation: analysis of its effectiveness, losses and impact on the motor performance – a study for design guidelines

    by Marco Túlio Alves Êvo, Hélder de Paula

    The authors deal with the use of electrostatic shielding to mitigate the electric discharge machining (EDM) currents on the induction machine bearings. Employing 2D and 3D models, several finite element analysis (FEA) simulations were thoroughly made addressing the shielding effectiveness to attenuate the shaft‐to‐frame voltage and the associated eddy current losses for different shield widths, thicknesses and materials. The obtained results provide very good guidelines for the practical design of the shielding device. In addition, comparisons between frequency‐ and time‐domain models highlight the importance of considering factors such as the saturation of the iron core, the rotor movement and non‐sinusoidal sources to compute the eddy current losses in the shield. Besides, the authors present a comprehensive theoretical review of the EDM currents, where the main influencing factors and action mechanisms are compiled in a clear and didactic approach, for the purpose of broad comprehension.


  • Experimental Investigation of Magnetic Field Shielding Techniques and Resulting Current Derating of Underground Power Cables

    by Diogo S. C. Souza, Carlos E. F. Caetano, Helder de Paula, Ivan J. S. Lopes, Wallace Do C. Boaventura, Jose Osvaldo S. Paulino, Marco Tulio A. Evo

    The paper presents an experimental investiga-tion on the efficiency of different underground transmis-sion/distribution line magnetic shielding techniques. Measure-ment results of magnetic field and temperature rise around the cable conductors are shown. An analysis of the thermal effects of each shielding technique on the line power capacity is pre-sented. The experiments were performed on a test site where a real 138 kV underground cable section was built. The results provide useful information that can guide the designer when choosing the most suitable shielding technique according to the required shielding factor taking into account its impact on the line rated power.


  • Study of the Influence of Underground Power Line Shielding Techniques on Its Power Capability

    by Marco Túlio A. Êvo, Hélder de Paula, Ivan José S. Lopes, Renato C. Mesquita, Diogo S. C. Souza